期刊文献+
共找到3,079篇文章
< 1 2 154 >
每页显示 20 50 100
Determination of Lead in Lime-preserved Egg by Microwave Digestion and Flame Atomic Absorption Spectroscopy
1
作者 Mimi ZHANG 《Asian Agricultural Research》 2023年第7期51-53,共3页
[Objectives] To establish a method for determining the lead content in lime-preserved eggs, to provide a theoretical basis for the quality control of production enterprises and the sampling and testing of supervision ... [Objectives] To establish a method for determining the lead content in lime-preserved eggs, to provide a theoretical basis for the quality control of production enterprises and the sampling and testing of supervision departments. [Methods] The lead content in lime-preserved eggs was measured by the microwave digestion and flame atomic absorption spectroscopy. [Results] The method had a correlation coefficient of r2=0.998 in the injection concentration range of 0-4 mg/L. The detection limit of the method was 0.008 2 mg/kg. In the range of 0.2 to 1.0 mg/kg addition concentration, the recovery rate of the method was 92.5%-108.0%, and the relative standard deviation(RSD) was <5%. [Conclusions] This method is accurate and reliable, simple and efficient, and is suitable for the detection of lead in lime-preserved eggs. 展开更多
关键词 Microwave Digestion flame atomic absorption spectroscopy Lime-preserved eggs LEAD
下载PDF
Determination of Chromium and Zinc in Soil by Microwave Digestion and Flame Atomic Absorption Spectrometry 被引量:4
2
作者 王天顺 牙禹 +4 位作者 何洁 莫磊兴 林波 李松 朱俊杰 《Agricultural Science & Technology》 CAS 2015年第9期1962-1964,共3页
[Objective] The aim was to develop a rapid, simple method for determination of chromium and zinc in soil samples by flame atomic absorption spectrometry.[Method] The method for determination of Cr and Zn in soil by co... [Objective] The aim was to develop a rapid, simple method for determination of chromium and zinc in soil samples by flame atomic absorption spectrometry.[Method] The method for determination of Cr and Zn in soil by combined flame atomic absorption spectrometry and microwave digestion was used. [Result] The concentration curve was linear within the range of 0-0.8 mg/L for Cr and 0-0.8 mg/L for Zn, the detection limits of Cr and Zn was 0.0025 mg/L and 0.002 3 mg/L, respectively. Recoveries of 102.4%-103.2% for Cr and 97.7%-98.3% for Zn were obtained for there soil samples. [Conclusion] The proposed method has the advantages of simple operation, high sensitivity, and high efficiency; it was successfully used for determination of Cr and Zn in soil samples. 展开更多
关键词 Microwave digestion flame atomic absorption spectrometry CHROMIUM ZINC SOIL
下载PDF
Rapid Determination of Cd in Squilla by Mixed Acid Leaching-flame Atomic Absorption Method
3
作者 刘琴 钟志 +1 位作者 祝银 王范盛 《Agricultural Science & Technology》 CAS 2016年第12期2732-2733,共2页
[Objective] This study was conducted to find a method for rapid determi-nation of Cd in squil a. [Method] Cd in squil a was determined by mixed acid leach-ing-flame atomic absorption method by digesting samples with H... [Objective] This study was conducted to find a method for rapid determi-nation of Cd in squil a. [Method] Cd in squil a was determined by mixed acid leach-ing-flame atomic absorption method by digesting samples with HNO3-HSO4 (5:1) and determining Cd in the samples by a flame atomic absorption spectrophotometer. [Results] The Cd contents in squil a were 1.0-2.0 mg/kg, and the recoveries of Cd were 86%-109%, and the relative standard deviations were 0-6%. [Conclusion] The method is simple and rapid with strong operability, good reproducibility and high ac-curacy. 展开更多
关键词 SQUILLA flame atomic absorption Mixed acid leaching CD
下载PDF
Determination of Five Metallic Elements in Guoshangye from Guizhou by Microwave Digestion-flame Atomic Absorption Spectrometry
4
作者 马四补 王绍辉 +2 位作者 刘同祥 李开斌 陈维 《Agricultural Science & Technology》 CAS 2016年第2期262-264,共3页
In the study, the contents of 5 trace elements including Fe, Cu, Mg, Mn and Ca were directly analyzed by flame atomic absorption spectroscopy in Gu- oshangye. The sample was subjected to microwave digestion with HNO3 ... In the study, the contents of 5 trace elements including Fe, Cu, Mg, Mn and Ca were directly analyzed by flame atomic absorption spectroscopy in Gu- oshangye. The sample was subjected to microwave digestion with HNO3 and H2O2, and detected by the standard curve method. The results showed that Guoshangye contained abundant trace elements which rates of these trace elements were in the curacy and satisfactory. were necessary for human. The recovery range of 96%-103%. The method is ac- 展开更多
关键词 Trace elements Guoshangye flame atomic absorption spectroscopy
下载PDF
Determination of Trace Elements in Potatoes by Flame Atomic Absorption Spectrometry
5
作者 王宁芳 《Agricultural Science & Technology》 CAS 2014年第5期716-717,723,共3页
[Objective] This study aimed to analyze the contents of trace elements in potatoes from different production areas in Qinghai Province. [Method] By flame atomic absorption spectrometry (FAAS), the contents of variou... [Objective] This study aimed to analyze the contents of trace elements in potatoes from different production areas in Qinghai Province. [Method] By flame atomic absorption spectrometry (FAAS), the contents of various trace elements in potatoes were determined. [Result] Potatoes contain abundant trace elements such as Cu, Zn, Fe, Mn, Ca, K and Mg. To be specific, the contents of Ca, K and Mg were relatively high. [Conclusion] By using FAAS, the relative standard deviation was 1.17%-2.75% and the recovery rate was 97%-99.5%, indicating accurate and reli-able results with high precision. 展开更多
关键词 POTATO flame atomic absorption spectrometry Trace elements Relative deviation PRECISION
下载PDF
Application of multiwalled carbon nanotubes treated by potassium permanganate for determination of trace cadmium prior to flame atomic absorption spectrometry 被引量:3
6
作者 XIAO Jun-ping ZHOU Qing-xiang BAI Hua-hua 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2007年第10期1266-1271,共6页
In this study we investigated the enrichment ability of oxidized multiwalled carbon nanotubes (MWCNTs) and established a new method for the determination of trace cadmium in environment with flame atomic absorption ... In this study we investigated the enrichment ability of oxidized multiwalled carbon nanotubes (MWCNTs) and established a new method for the determination of trace cadmium in environment with flame atomic absorption spectrometry. The MWCNTs were oxidized by potassium permanganate under appropriate conditions before use as preconcentration packing. Parameters influencing the recoveries of target analytes were optimized. Under optimal conditions, the target analyte exhibited a good linearity (R^2=0.9992) over the concentration range 0.5-50 ng/ml. The detection limit and precision of the proposed method were 0.15 ng/ml and 2.06%, respectively. The proposed method was applied to the determination of cadmium in real-world environmental samples and the recoveries were in the range of 91.3%-108.0%. All these experimental results indicated that this new procedure could be applied to the determination of trace cadmium in environmental waters. 展开更多
关键词 multiwalled carbon nanombes (MWCNTs) solid-phase extraction flame atomic absorption spectrometry
下载PDF
Preconcentration of copper with multi-walled carbon nanotubes pretreated by potassium permanganate cartridge for solid phase extraction prior to flame atomic absorption spectrometry 被引量:2
7
作者 Jun Ping Xiao Qing Xiang Zhou Hua Hua Bai 《Chinese Chemical Letters》 SCIE CAS CSCD 2007年第6期714-717,共4页
A procedure for the preconcentration of copper was described in this paper using multi-walled carbon nanotubes (MWCNTs) oxidized by potassium permanganate as the adsorbent for the enrichment of trace copper in water s... A procedure for the preconcentration of copper was described in this paper using multi-walled carbon nanotubes (MWCNTs) oxidized by potassium permanganate as the adsorbent for the enrichment of trace copper in water samples. Important parameters, such as the sample pH, the concentration and volume of eluent, sample flow rate and volume, and interference of coexisting ions, were investigated. The obtained results indicated that proposed method possessed an excellent analytical performance. The linear range, the detection limit, and precison (RSD) were 1–100 ng/mL (R(2) = 0.9993), 0.32 ng/mL and 2.88%, respectively. The results showed that copper could be adsorbed quantitatively on the pretreated MWCNTs with potassium permanganate, and proposed method was very useful in the monitoring of copper in the environment. 展开更多
关键词 Multi-walled carbon nanotubes Solid phase extraction (SPE) flame atomic absorption spectrometry
下载PDF
Determination of Trace Amounts of Zinc, Iron and Copper by Flame Atomic Absorption after Their Preconcentration Using Sodium Dodecyl Sulfate (SDS) Coated Alumina Nanoparticles Modified with 3-Mercapto-D-Valin from Environmental Samples 被引量:3
8
作者 Mohammad Reza Baezzat Hojjat Maleki +1 位作者 Ehsan Moghadamhosseyni Mahboobeh Tabandeh 《American Journal of Analytical Chemistry》 2014年第17期1228-1238,共11页
A sensitive and simple solid phase extraction method for the simultaneous determination of trace and toxic metals in environmental samples has been reported. The method is based on the adsorption of Zinc, Iron and Cop... A sensitive and simple solid phase extraction method for the simultaneous determination of trace and toxic metals in environmental samples has been reported. The method is based on the adsorption of Zinc, Iron and Copper on SDS-coated alumina nanoparticles, which is also modified with 3-mercapto-D-valine. The retained analyte ions on modified solid phase were eluted using 5 mL of 4 mol·L﹣1 HNO3. The analyte determination was carried out by flame atomic absorption spectrometry. The influences of some metal ion and anions on the recoveries of understudy analyte ion were investigated. The influences of the analytical parameters including pH, ligand and SDS amount, eluting solution (type and concentrations) and sample volume on metal ions recoveries were investigated. The extraction efficiency was > 98% with relative standard deviation lower than 3% the method has been successfully applied for the extraction and determination of these ions content in some real samples. Prepared adsorbent was characterized by SEM and FT-IR measurements. 展开更多
关键词 Sodium Dodecyl SULFATE (SDS) COATED ALUMINA Nanoparticles 3-Mercapto-D-Valin flame atomic absorption Solid Phase Extraction
下载PDF
Determination of Iron in Layered Crystal Sodium Disilicate and Sodium Silicate by Flame Atomic Absorption Spectrometry with Boric Acid as a Matrix Modifier 被引量:1
9
作者 Zhi Hua WANG Min CAI Shu Jun WANG 《Chinese Chemical Letters》 SCIE CAS CSCD 2006年第6期809-812,共4页
The effects of matrix silicate and experimental conditions on the determination of iron in flame atomic absorption spectrometry (FAAS) were investigated. It was found that boric acid as a matrix modifier obviously e... The effects of matrix silicate and experimental conditions on the determination of iron in flame atomic absorption spectrometry (FAAS) were investigated. It was found that boric acid as a matrix modifier obviously eliminated silicate interference. Under the optimum operating conditions, the determination results of iron in layered crystal sodium disilicate and sodium silicate samples by FAAS were satisfactory. The linear range of calibration curve is 0-10.5 μg.mL^-1, the relative standard deviation of method is 1.2%-2.2%, the recovery of added iron is 96.0%- 101%, the sensitivity is 0.19 μg.mL^-l and the detection limit is 77 ng.mL^-1. The effect of the determination of iron of the standard curve method, standard addition calibration and colorimetry method was the same, but the first has the merits of rapid sample preparation, reduced contamination risks and fast analysis. 展开更多
关键词 Layered crystal sodium disilicate sodium silicate flame atomic absorption spectrometry determination of iron boric acid.
下载PDF
The Use of Multiwalled Carbon Nanotubes Mini Column for Preconcentration of Trace Metal Ions in Tap Water of Khartoum City and Their Determination by Flame Atomic Absorption Spectrometry (FAAS) 被引量:2
10
作者 Leena Omer Hassan Ahmed 《Journal of Environmental Science and Engineering(A)》 2012年第2期169-174,共6页
The adsorption behavior of multiwalled carbon nanotubes (MWNTs) toward heavy elements has been investigated systemically, and a new method has been developed for the determination of trace elements in water samples ... The adsorption behavior of multiwalled carbon nanotubes (MWNTs) toward heavy elements has been investigated systemically, and a new method has been developed for the determination of trace elements in water samples based on preconcentration with mini-column packed with MWNTs prior to its determination by flame atomic absorption spectrometry (FAAS) The recommended parameters of proposed method influencing the preconcentration of the analytes, such as pH of the sample, sample flow rate and volume, elute solution and interfering ions, have been used. Under the optimized conditions, the calibration graphs were linear with the correlation coefficient range 0.9981-0.9995. According to the results, the metals were found 0.019-0.051, 0.011-0.031, 0.00-0.081, 0.00-0.0002, 0.007-0.0925, 0.00-0.0104 μg/L in water samples for Pb, Mn, Zn, Cd, Fe, Cu respectively. The percentage relative standard deviation (%RSD) for five replicate samples were 〈 5% in all cases. The method has been successfully applied to the determination of trace elements in some environmental samples with satisfactory results. 展开更多
关键词 Multiwalled carbon nanotubes solid phase extraction mini-column heavy metals flame atomic absorption spectroscopy.
下载PDF
Speciation of Dissolved Trace Nickel in Environmental Waters by On-Line Sonodigestion-Flow Injection Solid Phase Extraction Coupled to Flame Atomic Absorption Spectrometry 被引量:1
11
作者 M. C. Yebra-Biurrun J. M. Castro-Romero 《American Journal of Analytical Chemistry》 2011年第2期116-125,共10页
A simple on-line sonodigestion system was successfully used for breakdown organic nickel complexes in environmental waters acidified with diluted nitric acid prior to flow injection total dissolved nickel preconcentra... A simple on-line sonodigestion system was successfully used for breakdown organic nickel complexes in environmental waters acidified with diluted nitric acid prior to flow injection total dissolved nickel preconcentration in a microcolumn containing a chelating resin (Chelite Che with iminodiacetic acid groups) and determination by flame atomic absorption spectrometry. For the determination of the dissolved labile nickel fraction, microcolumns packed with the chelating resin were loaded in-situ with the sample without sample pH modification, and once in the laboratory were inserted in the flow injection device where nickel elution-detection was carried out. The performance of the chelating resin was investigated in order to elucidate its behavior in the presence of dissolved nickel species. The results obtained reveal that the resin, at the experimental employed conditions, retained only dissolved free nickel ions and nickel bound to weak complexes (labile fraction). The figures of merit for determinations in both nickel fractions are given and the obtained values are discussed. The speciation scheme is applied to the analysis of nickel in river and seawater samples collected in Galicia (Northwest, Spain). The results of fractionation showed that Ni are mainly in the dissolved labile fraction in river water, while in seawater samples analyzed was mainly present in the organic fraction. 展开更多
关键词 Sonodigestion PRECONCENTRATION Flow Injection Nickel SPECIATION flame atomic absorption SPECTROMETRY Environmental Water
下载PDF
Separation/Enrichment of Copper and Silver Using Titanium Dioxide Nanoparticles Coated with Poly-Thiophene and Their Analysis by Flame Atomic Absorption Spectrophotometry 被引量:1
12
作者 Mohammad Behbahani Meysam Babapour +4 位作者 Mostafa M. Amini Omid Sadeghi Akbar Bagheri Mani Salarian Banafsheh Rafiee 《American Journal of Analytical Chemistry》 2013年第2期90-98,共9页
We report on the use of titanium dioxide nanoparticles (NPs) coated with poly-thiophene for the preconcentration of copper and silverions. The NPs were prepared by first modifying the surface of TiO2 NPs with vinyl gr... We report on the use of titanium dioxide nanoparticles (NPs) coated with poly-thiophene for the preconcentration of copper and silverions. The NPs were prepared by first modifying the surface of TiO2 NPs with vinyl groups and then copolymerizing them with vinyl thiophen. The resulting TiO2-polythiophene core-shell NPs were characterized by thermogravimetry, differential thermal analysis, scanning electron microscopy, Fourier transform infrared spectrometry and X-ray diffraction. The experimental conditions such as pH value, adsorption and desorption time, type, concentration and volume of the eluent, break through volume, and effect of potentially interfering ions were optimized. The ions were then desorbed with hydrochloric acid and determined by FAAS. The limits of detection are 0.4 and 1.2 μg·L_1 for Cu(II) and Ag(I), respectively, and recoveries and precisions are >98.0% 展开更多
关键词 Novel Poly-Thiophene-TiO2 Nanoparticles COPPER SILVER flame atomic absorption SPECTROPHOTOMETRY
下载PDF
Use of Flame Atomic Absorption Spectroscopy and Multivariate Analysis for the Determination of Trace Elements in Human Scalp 被引量:1
13
作者 Sayo O. Fakayode Sri Lanka Owen +1 位作者 David A. Pollard Mamudu Yakubu 《American Journal of Analytical Chemistry》 2013年第7期348-359,共12页
The analysis of trace elements in human hair for use as biomarkers continues to generate considerable interest in environmental and bioanalytical studies, medical diagnostics, and forensic science. This study investig... The analysis of trace elements in human hair for use as biomarkers continues to generate considerable interest in environmental and bioanalytical studies, medical diagnostics, and forensic science. This study investigated the concentrations of essential and toxic elements (Fe, Mg, Ca, Cu, Zn, Cr, Cd, and Pb) using flame atomic absorption spectroscopy (FAAS) in human scalp hair obtained from subjects living in Forsyth County, North Carolina, USA. The influence of age, sex, race, and smoking habits on the levels of trace elements in the hair samples were also investigated. Additionally, analyses were subjected to a statistical, regression, and principal component analysis to evaluate inter-elemental association and possible pattern recognition in hair samples. Furthermore, Ca/Mg and Zn/Cu ratios, which are often used to evaluate the degree of Ca and Cu utilization in humans and as markers for various health related issues including, atherosclerosis, hypertension, insulin sensitivity, and pancreatic cancer, were calculated. The overall mean concentrations of Fe (25 μg/g), Ca (710 μg/g), Mg (120 μg/g), Zn (190 μg/g), Cu (12 μg/g), and Cr (0.20 μg/g) were found in hair samples. The trace element concentrations varied widely in hair samples as demonstrated by large range of concentrations obtained for each element. However, levels of Cd and Pb elements of <0.030 μg/g were detected in hair sample. In general, the levels of the trace elements in hair samples were poorly correlated. However, significant correlations were found between Ca and Mg (r = 0.840, p = 0.05). The levels of Fe, Ca, Mg, Zn, Cu, and Cr in hair samples and the calculated Ca/Mg and Zn/Cu ratios were found to be largely correlated with age, race, sex, and smoking habits. 展开更多
关键词 HUMAN SCALP HAIR BIOMONITORING Trace ELEMENT Concentration flame atomic absorption SPECTROSCOPY Regression and Principal Component Analysis Inter-Element Association
下载PDF
FLAME ATOMIC ABSORPTION DETERMINATION OF COPPER IN CEREALS FOOD SAMPLES WITH THE PRECONCENTRATION OF POTASSIUM TETRATITANATE WHISKER 被引量:1
14
作者 XU Wanzhen ZHANG Xinghua +2 位作者 YAN Yongsheng LIU Aiqin JING Junjie 《Chinese Journal of Reactive Polymers》 2007年第1期22-30,共9页
A simple and reliable method has been developed for separation and preconcentration of trace amounts of copper ions in cereals food for subsequent measurement by flame atomic absorption spectrometry (FAAS). The Cu^2... A simple and reliable method has been developed for separation and preconcentration of trace amounts of copper ions in cereals food for subsequent measurement by flame atomic absorption spectrometry (FAAS). The Cu^2+ ions are adsorbed selectively and quantitatively during the passage. The retained copper ions were desorbed from the potassium tetratitanate whisker with 10.0mL of 2mol/L sulphuric acid solutions as eluent and were determined by FAAS. The linear range was 0.05μg/mL-0.20μg/mL in the original solution with a correlation coefficient of 0.9998. The detection limit of the proposed method is 2. lng/mL in the original solution (3σ, n=9). Determination of copper in standard ions showed that the proposed method has good accuracy (recovery was more than 95%). The method was successfully applied for recovery and determination of copper in cereals food samples 展开更多
关键词 flame atomic absorption spectrometry COPPER Cereals food Potassium tetratitanate whisker.
下载PDF
Flow-Injection Flame Atomic Absorption Determination of Hexavalent Chromium with On-Line Preconcentration on an Anion Imprinted Polymer 被引量:1
15
作者 María Carmen Yebra-Biurrun Jesús Manuel Castro-Romero Nieves Carro-Marino 《American Journal of Analytical Chemistry》 2012年第11期755-760,共6页
A flow injection preconcentration system for the flame atomic absorption spectrometric determination of hexavalent chromium has been developed. The method employs on-line preconcentration of Cr(VI) on a minicolumn pac... A flow injection preconcentration system for the flame atomic absorption spectrometric determination of hexavalent chromium has been developed. The method employs on-line preconcentration of Cr(VI) on a minicolumn packed with Cr(VI)-imprinted poly(4-vinyl pyridineco-2-hydroxyethyl methacrylate) placed into a flow injection system. Hexava-lent chromium was eluted with a small volume of diluted hydrochloric acid into the nebulizer-burner system of a flame atomic absorption spectrometer. An enrichment factor of 550 and a 3σ detection limit of 0.04 μg·L-1 along a sampling frequency of 4 h-1 at a sample flow rate of 3.5 mL·min-1. The relative standard deviation is 2.9% for 1 μg·L-1 Cr(VI) (n = 11). The flow injection system proposed has the advantage of being simpler because the use of expensive and sophisticated instruments is avoided. Ease of use, continuous process and selectivity make this method suitable for Cr(VI) determination in different environmental samples such as sea and river waters, soils and sediments. 展开更多
关键词 Hexavalent Chromium flame atomic absorption Spectrometry PRECONCENTRATION Flow Injection Environmental Samples
下载PDF
Determination of Copper and Lead Contents in Soil of the Yellow River Wetland in Shaanxi Province by Flame Atomic Absorption Spectrometry
16
作者 Xiaoxiang QIU Fengfeng ZHANG Haizhen WU 《Agricultural Biotechnology》 CAS 2019年第2期146-148,共3页
[Objectives] The contents of copper and lead in the soil of the Yellow River Wetland were determined by flame atomic absorption spectrometry, which provides a theoretical basis for the treatment of soil pollution. [Me... [Objectives] The contents of copper and lead in the soil of the Yellow River Wetland were determined by flame atomic absorption spectrometry, which provides a theoretical basis for the treatment of soil pollution. [Methods] The soil was digested with a concentrated nitric acid-hydrofluoric acid-perchloric acid system, and the contents of heavy metals such as copper and lead in the Yellow River Wetland of Shaanxi Province were determined by flame atomic absorption spectrometry. [Results] The correlation coefficients reached 0.999 5 in the range of 0.00-1.00 mg/L, indicating good linearity. [Conclusions] The method is simple in operation, good in reproducibility, high in sensitivity to most elements, and can be widely used. 展开更多
关键词 flame atomic absorption SPECTROMETRY WETLAND SOIL COPPER Lead
下载PDF
Preconcentration of Lead in Sugar Samples by Solid Phase Extraction and Its Determination by Flame Atomic Absorption Spectrometry
17
作者 Saied Saeed Hosseiny Davarani Neda Sheijooni-Fumani +2 位作者 Amin Morteza Najarian Mohammad-Ali Tabatabaei Siavash Vahidi 《American Journal of Analytical Chemistry》 2011年第5期626-631,共6页
A simple and sensitive solid phase extraction utilizing C18 filled cartridges incorporated with dithizone for preconcentration of lead and its subsequent determination by flame atomic absorption spectrometry (FAAS) wa... A simple and sensitive solid phase extraction utilizing C18 filled cartridges incorporated with dithizone for preconcentration of lead and its subsequent determination by flame atomic absorption spectrometry (FAAS) was developed. Several parameters such as type, concentration and volume of eluent, pH of the sample solution, flow rate of extraction and volume of the sample were evaluated. The effect of a variety of ions on preconcentration and recovery was also investigated. At pH = 7.4 and 1.0 mol?L–1 HCl eluting them, lead ions were recovered quantitatively. The limit of detection (LOD) defined as 3Sbl was determined to be 8.1 μg L–1 for 500 mL of sample solution and eluted with 5 mL of 1.0 mol?L–1 HCl under optimum conditions. The accuracy and precision (RSD %) of the method were >90% and <10%, respectively. In the end, the proposed method was applied to a number of real sugar samples and the amount of lead was determined by spiking a known concentration of lead into the solution. 展开更多
关键词 Solid Phase Extraction LEAD DITHIZONE flame atomic absorption Spectroscopy (FAAS) C18 Modified Cartridges
下载PDF
Chemical Analysis of Magnesia and Magnesia-Alumina Refractory Materials——Flame atomic absorption spectrometric method for determination of calcium oxide content
18
作者 ZHANG Xiaohui 《China's Refractories》 CAS 2006年第4期41-43,共3页
1 Scope This standard specifics the determination of calcium oxide coutent by flame atomic absorption spectrometric method.
关键词 Chemical Analysis of Magnesia and Magnesia-Alumina Refractory Materials flame atomic absorption spectrometric method for determination of calcium oxide content
下载PDF
Determination of Manganese in Tri Calcium Phosphate (TCP) by Atomic Absorption Spectrometry 被引量:1
19
作者 Y. Yildiz R. Karadag +1 位作者 M. Cordera B. Gensinger 《American Journal of Analytical Chemistry》 2020年第8期301-308,共8页
Tricalcium phosphate Anhydrous Powder typically contains less than 10 ppm (mg/Kg) (w/w) manganese. This level can be determined utilizing Flame Atomic Absorption Spectrometer (AAS) and standard based on known standard... Tricalcium phosphate Anhydrous Powder typically contains less than 10 ppm (mg/Kg) (w/w) manganese. This level can be determined utilizing Flame Atomic Absorption Spectrometer (AAS) and standard based on known standards. A number of analytical methods are presently used for the analysis of metals in the biochemical. The instrumental techniques available are Inductively Coupled Plasma (ICP/MS), X-Ray Fluorescence, UV-VIS Spectrophotometry, and Atomic Absorption Spectrometry. Flame AA has gained widespread acceptance as an analytical technique and is used for many applications. In this study, we have determined the amount of manganese metal present in Tricalcium Phosphate (TCP) using Flame Atomic Absorption Spectrophotometer. The method has high precision and accuracy. The percent recovery was found to be 99.8% for spiked sample. The results meet the requirement. 展开更多
关键词 Manganese Determination Tri Calcium Phosphate flame atomic absorption Spectrometry
下载PDF
Dental Erosion by Beverages and Determination of Trace Elements in Teeth by Atomic Absorption Spectrometry
20
作者 Safaa Sabri Najim Maiada Abdulla Adnan 《American Journal of Analytical Chemistry》 2016年第7期548-555,共9页
The analysis of trace elements in human tooth for use as biomarkers continues to generate considerable interest in environmental and bioanalytical studies, medical diagnostic and forensic science. This study investiga... The analysis of trace elements in human tooth for use as biomarkers continues to generate considerable interest in environmental and bioanalytical studies, medical diagnostic and forensic science. This study investigated concentrations of essential and toxic elements (Zn, Cu, Pb, Ni, Co and Cd) using flame atomic absorption spectroscopy (FAAS) and (Na and K) flame atomic emission spectroscopy (FAES) in human tooth obtained from Misan province, Iraq. The influence of smoking habits and born children on the levels of trace elements in additional to dental erosion by some beverages in the tooth samples were investigated. The overall of mean concentrations of (Zn 185.2 ppm, Cu 36.11 ppm, Pb 18.63 ppm, Ni 13.44 ppm, Co 3.45 ppm, and Cd 0.58 ppm, Na 11.683 ppm and K 115.27 ppm), (Zn 178.243 ppm, Cu 35.877 ppm, Pb 15.64 ppm, Ni 12.89 ppm, Co 3.421 ppm, Cd 0.455 ppm, Na 11,558.04 ppm and K 114.04 ppm) in smokers and non-smokers tooth groups respectively, (Zn 81.12 ppm, Cu 24.37 ppm, Pb 11.18 ppm, Ni 13.68 ppm, Co 3.32 ppm, Cd 0.44 ppm, Na 8227 ppm and K 76.42 ppm), (Zn 80.58 ppm, Cu 24.30 ppm, Pb 10.86 ppm, Ni 12.74 ppm, Co 2.71 ppm, Cd 0.23 ppm, Na 8165 ppm and K 72.80 ppm) in mothers and wives tooth groups respectively. However the w/w% loss of tooth immersed in following order of beverages (green tea, black tea, cinnamon, hibiscus, vinegar and citrus aurantifolia (9.09, 9.68, 12.36, 15.01, 16.77 and 17.38), (8.19, 8.25, 9.76, 13.37, 14.02 and 15.33) in smokers and non-smokers groups respectively, (11.25, 11.47, 13.30, 15.75, 19.58, and 20.91), (8.31, 7.96, 11.39, 13.49, 17.40, and 17.67) in mothers and wives groups respectively. However, there is a statistically significant variance found Zn (t<sub>cal</sub> 5.029, t<sub>tab</sub> 2.131), Pb (t<sub>cal</sub> 4.8538, t<sub>tab</sub> 2.131), Ni (t<sub>ca</sub><sub>l</sub> 5.243, t<sub>tab</sub> 2.131), Cd (t<sub>cal</sub> 3.9062, t<sub>tab</sub> 2.131) and Na (t<sub>cal</sub> 3.0832, t<sub>tab</sub> 2.131) between smokers and non-smokers tooth groups. However, the Co (t<sub>cal</sub> 2.7403, t<sub>tab</sub> 2.131) also shows statistically significant variance between mothers and wives groups. There is no statistically significant variance in w/w% loss after immersed the tooth in some beverages but in general it was higher in smokers than non-smokers and in mothers higher than wives. 展开更多
关键词 flame atomic absorption Spectroscopy flame atomic Emission Spectroscopy Trace Element Concentrations BIOMARKER
下载PDF
上一页 1 2 154 下一页 到第
使用帮助 返回顶部