期刊文献+
共找到2,122篇文章
< 1 2 107 >
每页显示 20 50 100
Determination of Chromium and Zinc in Soil by Microwave Digestion and Flame Atomic Absorption Spectrometry 被引量:4
1
作者 王天顺 牙禹 +4 位作者 何洁 莫磊兴 林波 李松 朱俊杰 《Agricultural Science & Technology》 CAS 2015年第9期1962-1964,共3页
[Objective] The aim was to develop a rapid, simple method for determination of chromium and zinc in soil samples by flame atomic absorption spectrometry.[Method] The method for determination of Cr and Zn in soil by co... [Objective] The aim was to develop a rapid, simple method for determination of chromium and zinc in soil samples by flame atomic absorption spectrometry.[Method] The method for determination of Cr and Zn in soil by combined flame atomic absorption spectrometry and microwave digestion was used. [Result] The concentration curve was linear within the range of 0-0.8 mg/L for Cr and 0-0.8 mg/L for Zn, the detection limits of Cr and Zn was 0.0025 mg/L and 0.002 3 mg/L, respectively. Recoveries of 102.4%-103.2% for Cr and 97.7%-98.3% for Zn were obtained for there soil samples. [Conclusion] The proposed method has the advantages of simple operation, high sensitivity, and high efficiency; it was successfully used for determination of Cr and Zn in soil samples. 展开更多
关键词 Microwave digestion flame atomic absorption spectrometry CHROMIUM ZINC SOIL
下载PDF
Determination of Trace Elements in Potatoes by Flame Atomic Absorption Spectrometry
2
作者 王宁芳 《Agricultural Science & Technology》 CAS 2014年第5期716-717,723,共3页
[Objective] This study aimed to analyze the contents of trace elements in potatoes from different production areas in Qinghai Province. [Method] By flame atomic absorption spectrometry (FAAS), the contents of variou... [Objective] This study aimed to analyze the contents of trace elements in potatoes from different production areas in Qinghai Province. [Method] By flame atomic absorption spectrometry (FAAS), the contents of various trace elements in potatoes were determined. [Result] Potatoes contain abundant trace elements such as Cu, Zn, Fe, Mn, Ca, K and Mg. To be specific, the contents of Ca, K and Mg were relatively high. [Conclusion] By using FAAS, the relative standard deviation was 1.17%-2.75% and the recovery rate was 97%-99.5%, indicating accurate and reli-able results with high precision. 展开更多
关键词 POTATO flame atomic absorption spectrometry Trace elements Relative deviation PRECISION
下载PDF
Application of multiwalled carbon nanotubes treated by potassium permanganate for determination of trace cadmium prior to flame atomic absorption spectrometry 被引量:3
3
作者 XIAO Jun-ping ZHOU Qing-xiang BAI Hua-hua 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2007年第10期1266-1271,共6页
In this study we investigated the enrichment ability of oxidized multiwalled carbon nanotubes (MWCNTs) and established a new method for the determination of trace cadmium in environment with flame atomic absorption ... In this study we investigated the enrichment ability of oxidized multiwalled carbon nanotubes (MWCNTs) and established a new method for the determination of trace cadmium in environment with flame atomic absorption spectrometry. The MWCNTs were oxidized by potassium permanganate under appropriate conditions before use as preconcentration packing. Parameters influencing the recoveries of target analytes were optimized. Under optimal conditions, the target analyte exhibited a good linearity (R^2=0.9992) over the concentration range 0.5-50 ng/ml. The detection limit and precision of the proposed method were 0.15 ng/ml and 2.06%, respectively. The proposed method was applied to the determination of cadmium in real-world environmental samples and the recoveries were in the range of 91.3%-108.0%. All these experimental results indicated that this new procedure could be applied to the determination of trace cadmium in environmental waters. 展开更多
关键词 multiwalled carbon nanombes (MWCNTs) solid-phase extraction flame atomic absorption spectrometry
下载PDF
Preconcentration of copper with multi-walled carbon nanotubes pretreated by potassium permanganate cartridge for solid phase extraction prior to flame atomic absorption spectrometry 被引量:2
4
作者 Jun Ping Xiao Qing Xiang Zhou Hua Hua Bai 《Chinese Chemical Letters》 SCIE CAS CSCD 2007年第6期714-717,共4页
A procedure for the preconcentration of copper was described in this paper using multi-walled carbon nanotubes (MWCNTs) oxidized by potassium permanganate as the adsorbent for the enrichment of trace copper in water s... A procedure for the preconcentration of copper was described in this paper using multi-walled carbon nanotubes (MWCNTs) oxidized by potassium permanganate as the adsorbent for the enrichment of trace copper in water samples. Important parameters, such as the sample pH, the concentration and volume of eluent, sample flow rate and volume, and interference of coexisting ions, were investigated. The obtained results indicated that proposed method possessed an excellent analytical performance. The linear range, the detection limit, and precison (RSD) were 1–100 ng/mL (R(2) = 0.9993), 0.32 ng/mL and 2.88%, respectively. The results showed that copper could be adsorbed quantitatively on the pretreated MWCNTs with potassium permanganate, and proposed method was very useful in the monitoring of copper in the environment. 展开更多
关键词 Multi-walled carbon nanotubes Solid phase extraction (SPE) flame atomic absorption spectrometry
下载PDF
Determination of Iron in Layered Crystal Sodium Disilicate and Sodium Silicate by Flame Atomic Absorption Spectrometry with Boric Acid as a Matrix Modifier 被引量:1
5
作者 Zhi Hua WANG Min CAI Shu Jun WANG 《Chinese Chemical Letters》 SCIE CAS CSCD 2006年第6期809-812,共4页
The effects of matrix silicate and experimental conditions on the determination of iron in flame atomic absorption spectrometry (FAAS) were investigated. It was found that boric acid as a matrix modifier obviously e... The effects of matrix silicate and experimental conditions on the determination of iron in flame atomic absorption spectrometry (FAAS) were investigated. It was found that boric acid as a matrix modifier obviously eliminated silicate interference. Under the optimum operating conditions, the determination results of iron in layered crystal sodium disilicate and sodium silicate samples by FAAS were satisfactory. The linear range of calibration curve is 0-10.5 μg.mL^-1, the relative standard deviation of method is 1.2%-2.2%, the recovery of added iron is 96.0%- 101%, the sensitivity is 0.19 μg.mL^-l and the detection limit is 77 ng.mL^-1. The effect of the determination of iron of the standard curve method, standard addition calibration and colorimetry method was the same, but the first has the merits of rapid sample preparation, reduced contamination risks and fast analysis. 展开更多
关键词 Layered crystal sodium disilicate sodium silicate flame atomic absorption spectrometry determination of iron boric acid.
下载PDF
Speciation of Dissolved Trace Nickel in Environmental Waters by On-Line Sonodigestion-Flow Injection Solid Phase Extraction Coupled to Flame Atomic Absorption Spectrometry 被引量:1
6
作者 M. C. Yebra-Biurrun J. M. Castro-Romero 《American Journal of Analytical Chemistry》 2011年第2期116-125,共10页
A simple on-line sonodigestion system was successfully used for breakdown organic nickel complexes in environmental waters acidified with diluted nitric acid prior to flow injection total dissolved nickel preconcentra... A simple on-line sonodigestion system was successfully used for breakdown organic nickel complexes in environmental waters acidified with diluted nitric acid prior to flow injection total dissolved nickel preconcentration in a microcolumn containing a chelating resin (Chelite Che with iminodiacetic acid groups) and determination by flame atomic absorption spectrometry. For the determination of the dissolved labile nickel fraction, microcolumns packed with the chelating resin were loaded in-situ with the sample without sample pH modification, and once in the laboratory were inserted in the flow injection device where nickel elution-detection was carried out. The performance of the chelating resin was investigated in order to elucidate its behavior in the presence of dissolved nickel species. The results obtained reveal that the resin, at the experimental employed conditions, retained only dissolved free nickel ions and nickel bound to weak complexes (labile fraction). The figures of merit for determinations in both nickel fractions are given and the obtained values are discussed. The speciation scheme is applied to the analysis of nickel in river and seawater samples collected in Galicia (Northwest, Spain). The results of fractionation showed that Ni are mainly in the dissolved labile fraction in river water, while in seawater samples analyzed was mainly present in the organic fraction. 展开更多
关键词 Sonodigestion PRECONCENTRATION Flow Injection Nickel SPECIATION flame atomic absorption spectrometry Environmental Water
下载PDF
Determination of Copper and Lead Contents in Soil of the Yellow River Wetland in Shaanxi Province by Flame Atomic Absorption Spectrometry
7
作者 Xiaoxiang QIU Fengfeng ZHANG Haizhen WU 《Agricultural Biotechnology》 CAS 2019年第2期146-148,共3页
[Objectives] The contents of copper and lead in the soil of the Yellow River Wetland were determined by flame atomic absorption spectrometry, which provides a theoretical basis for the treatment of soil pollution. [Me... [Objectives] The contents of copper and lead in the soil of the Yellow River Wetland were determined by flame atomic absorption spectrometry, which provides a theoretical basis for the treatment of soil pollution. [Methods] The soil was digested with a concentrated nitric acid-hydrofluoric acid-perchloric acid system, and the contents of heavy metals such as copper and lead in the Yellow River Wetland of Shaanxi Province were determined by flame atomic absorption spectrometry. [Results] The correlation coefficients reached 0.999 5 in the range of 0.00-1.00 mg/L, indicating good linearity. [Conclusions] The method is simple in operation, good in reproducibility, high in sensitivity to most elements, and can be widely used. 展开更多
关键词 flame atomic absorption spectrometry WETLAND SOIL COPPER Lead
下载PDF
Preconcentration of Lead in Sugar Samples by Solid Phase Extraction and Its Determination by Flame Atomic Absorption Spectrometry
8
作者 Saied Saeed Hosseiny Davarani Neda Sheijooni-Fumani +2 位作者 Amin Morteza Najarian Mohammad-Ali Tabatabaei Siavash Vahidi 《American Journal of Analytical Chemistry》 2011年第5期626-631,共6页
A simple and sensitive solid phase extraction utilizing C18 filled cartridges incorporated with dithizone for preconcentration of lead and its subsequent determination by flame atomic absorption spectrometry (FAAS) wa... A simple and sensitive solid phase extraction utilizing C18 filled cartridges incorporated with dithizone for preconcentration of lead and its subsequent determination by flame atomic absorption spectrometry (FAAS) was developed. Several parameters such as type, concentration and volume of eluent, pH of the sample solution, flow rate of extraction and volume of the sample were evaluated. The effect of a variety of ions on preconcentration and recovery was also investigated. At pH = 7.4 and 1.0 mol?L–1 HCl eluting them, lead ions were recovered quantitatively. The limit of detection (LOD) defined as 3Sbl was determined to be 8.1 μg L–1 for 500 mL of sample solution and eluted with 5 mL of 1.0 mol?L–1 HCl under optimum conditions. The accuracy and precision (RSD %) of the method were >90% and <10%, respectively. In the end, the proposed method was applied to a number of real sugar samples and the amount of lead was determined by spiking a known concentration of lead into the solution. 展开更多
关键词 Solid Phase Extraction LEAD DITHIZONE flame atomic absorption Spectroscopy (faas) C18 Modified Cartridges
下载PDF
Determination of Manganese in Tri Calcium Phosphate (TCP) by Atomic Absorption Spectrometry 被引量:1
9
作者 Y. Yildiz R. Karadag +1 位作者 M. Cordera B. Gensinger 《American Journal of Analytical Chemistry》 2020年第8期301-308,共8页
Tricalcium phosphate Anhydrous Powder typically contains less than 10 ppm (mg/Kg) (w/w) manganese. This level can be determined utilizing Flame Atomic Absorption Spectrometer (AAS) and standard based on known standard... Tricalcium phosphate Anhydrous Powder typically contains less than 10 ppm (mg/Kg) (w/w) manganese. This level can be determined utilizing Flame Atomic Absorption Spectrometer (AAS) and standard based on known standards. A number of analytical methods are presently used for the analysis of metals in the biochemical. The instrumental techniques available are Inductively Coupled Plasma (ICP/MS), X-Ray Fluorescence, UV-VIS Spectrophotometry, and Atomic Absorption Spectrometry. Flame AA has gained widespread acceptance as an analytical technique and is used for many applications. In this study, we have determined the amount of manganese metal present in Tricalcium Phosphate (TCP) using Flame Atomic Absorption Spectrophotometer. The method has high precision and accuracy. The percent recovery was found to be 99.8% for spiked sample. The results meet the requirement. 展开更多
关键词 Manganese Determination Tri Calcium Phosphate flame atomic absorption spectrometry
下载PDF
FLAME ATOMIC ABSORPTION DETERMINATION OF COPPER IN CEREALS FOOD SAMPLES WITH THE PRECONCENTRATION OF POTASSIUM TETRATITANATE WHISKER 被引量:1
10
作者 XU Wanzhen ZHANG Xinghua +2 位作者 YAN Yongsheng LIU Aiqin JING Junjie 《Chinese Journal of Reactive Polymers》 2007年第1期22-30,共9页
A simple and reliable method has been developed for separation and preconcentration of trace amounts of copper ions in cereals food for subsequent measurement by flame atomic absorption spectrometry (FAAS). The Cu^2... A simple and reliable method has been developed for separation and preconcentration of trace amounts of copper ions in cereals food for subsequent measurement by flame atomic absorption spectrometry (FAAS). The Cu^2+ ions are adsorbed selectively and quantitatively during the passage. The retained copper ions were desorbed from the potassium tetratitanate whisker with 10.0mL of 2mol/L sulphuric acid solutions as eluent and were determined by FAAS. The linear range was 0.05μg/mL-0.20μg/mL in the original solution with a correlation coefficient of 0.9998. The detection limit of the proposed method is 2. lng/mL in the original solution (3σ, n=9). Determination of copper in standard ions showed that the proposed method has good accuracy (recovery was more than 95%). The method was successfully applied for recovery and determination of copper in cereals food samples 展开更多
关键词 flame atomic absorption spectrometry COPPER Cereals food Potassium tetratitanate whisker.
下载PDF
Flow-Injection Flame Atomic Absorption Determination of Hexavalent Chromium with On-Line Preconcentration on an Anion Imprinted Polymer 被引量:1
11
作者 María Carmen Yebra-Biurrun Jesús Manuel Castro-Romero Nieves Carro-Marino 《American Journal of Analytical Chemistry》 2012年第11期755-760,共6页
A flow injection preconcentration system for the flame atomic absorption spectrometric determination of hexavalent chromium has been developed. The method employs on-line preconcentration of Cr(VI) on a minicolumn pac... A flow injection preconcentration system for the flame atomic absorption spectrometric determination of hexavalent chromium has been developed. The method employs on-line preconcentration of Cr(VI) on a minicolumn packed with Cr(VI)-imprinted poly(4-vinyl pyridineco-2-hydroxyethyl methacrylate) placed into a flow injection system. Hexava-lent chromium was eluted with a small volume of diluted hydrochloric acid into the nebulizer-burner system of a flame atomic absorption spectrometer. An enrichment factor of 550 and a 3σ detection limit of 0.04 μg·L-1 along a sampling frequency of 4 h-1 at a sample flow rate of 3.5 mL·min-1. The relative standard deviation is 2.9% for 1 μg·L-1 Cr(VI) (n = 11). The flow injection system proposed has the advantage of being simpler because the use of expensive and sophisticated instruments is avoided. Ease of use, continuous process and selectivity make this method suitable for Cr(VI) determination in different environmental samples such as sea and river waters, soils and sediments. 展开更多
关键词 Hexavalent Chromium flame atomic absorption spectrometry PRECONCENTRATION Flow Injection Environmental Samples
下载PDF
不同消解方式对FAAS法测定建盏胎体Fe_(2)O_(3)含量的影响
12
作者 王楠 《福建分析测试》 CAS 2024年第1期29-32,37,共5页
建盏是宋代茶盏的典型代表,因其胎体中含有大量的铁元素,故有“铁胎”之称。对于建盏而言,富含铁元素,既是其重要特色,亦是其硬性指标。现代新烧的盏若不是铁胎,自然就不能称作建盏。准确定量建盏胎体Fe_(2)O_(3)含量是检测工作的重头戏... 建盏是宋代茶盏的典型代表,因其胎体中含有大量的铁元素,故有“铁胎”之称。对于建盏而言,富含铁元素,既是其重要特色,亦是其硬性指标。现代新烧的盏若不是铁胎,自然就不能称作建盏。准确定量建盏胎体Fe_(2)O_(3)含量是检测工作的重头戏,而正确有效的消解方式是其基本前提和关键步骤。本文以火焰原子吸收光谱法(FAAS)作为测试方法,对市售建盏样品进行3种不同的消解前处理后上机测试,并对比了测试结果。结果显示:标准曲线的相关系数R^(2)为0.9998;电热板湿法消解、熔融分解法和微波消解法的检出限分别为0.030mg/kg、0.021mg/kg和0.039mg/kg,三种方法都有着较高的精密度和准确度,均能达到日常生产检测的要求。 展开更多
关键词 黑釉瓷 建盏 火焰原子吸收光谱法(faas) 微波消解
下载PDF
活性炭动态富集-火焰原子吸收光谱法测定金矿石中金的影响因素探讨 被引量:2
13
作者 何涛 王鹏 +4 位作者 门倩妮 甘黎明 张晓星 宋永涛 程毅 《中国无机分析化学》 CAS 北大核心 2024年第4期429-435,共7页
金在新一轮找矿突破战略行动矿产分析中占有重要的地位,采用活性炭动态富集-火焰原子吸收光谱法测定岩石矿物样品中金的分析方法已被广泛应用。然而其分析条件的影响因素较多,在测定过程中活性炭的用量、灰分的大小、吸附层的设计以及... 金在新一轮找矿突破战略行动矿产分析中占有重要的地位,采用活性炭动态富集-火焰原子吸收光谱法测定岩石矿物样品中金的分析方法已被广泛应用。然而其分析条件的影响因素较多,在测定过程中活性炭的用量、灰分的大小、吸附层的设计以及洗涤液溶液温度等因素对测定结果的准确性具有重要影响。分别以活性炭用量、不同灰分值、吸附层数以及洗涤溶液的温度为变量,对金分析标准物质GBW(E)070013b、GBW07297a、GBW07299a、GBW07810进行实验对比分析。结果表明,金的回收率随着活性炭用量的增加而不断提升,在0.5 g后趋于稳定;活性炭灰分值越大,金元素损失越多,当灰分值小于0.05%时,回收率趋于稳定,接近99%;活性炭吸附层设计为双层和三层时,测定值的平均值与认定值的相对偏差(RE)和相对标准偏差(RSD,n=6)分别为0.14%~3.2%和0.040%~3.7%,优于混合层和单层,满足岩石矿物质控标准规范中正确度和精密度的要求;抽滤洗涤热溶液(70~80℃)时,金矿石标准物质金元素的平行样的准确度和相对标准标准偏差最小,均小于2.1%,通过方法验证,测定金的正确度精密度(RSD,n=6)分别小于0.76%和3.8%,满足DZ/T 0130.3—2006《地质矿产实验室测试质量管理规范》中岩石矿物样品化学成分分析的质量要求。优化了活性炭吸附测金的实验条件,方法的正确度和精密度均满足要求,能满足金矿石中金的准确测定。 展开更多
关键词 活性炭富集 火焰原子吸收光谱法 活性炭用量 洗涤温度
下载PDF
火焰原子吸收光谱法测定水性食品油墨中铜与铅的溶出量 被引量:2
14
作者 曹瑜 钟泽辉 +1 位作者 林锐斌 唐聪 《包装学报》 2024年第2期1-7,共7页
为探究水性油墨和印刷纸杯中可溶性铅和铜的溶出量,有效控制重金属迁移的安全风险,提出基于火焰原子吸收光谱法测定铜与铅元素的溶出量方法。先配制两种水性食品油墨即深红油墨和深绿油墨,并分析其性能,然后采用火焰原子吸收光谱法测定... 为探究水性油墨和印刷纸杯中可溶性铅和铜的溶出量,有效控制重金属迁移的安全风险,提出基于火焰原子吸收光谱法测定铜与铅元素的溶出量方法。先配制两种水性食品油墨即深红油墨和深绿油墨,并分析其性能,然后采用火焰原子吸收光谱法测定两种油墨和印刷纸杯中铜和铅的溶出量。实验结果表明:两种油墨的物理状态较为稳定,铜与铅元素在检测中质量浓度与光谱强度线性关系良好,其相对标准偏差分别为1.64%与2.24%,回收率分别在94.0%~101.0%和91.0%~94.8%之间;时间和温度对重金属溶出有较大影响,100℃条件下2 h的铅与铜溶出量分别是25℃条件下24 h铅与铜的8.3与2.36倍;深红墨的安全性高于深绿墨,所配制油墨及纸杯中铅与铜元素的溶出量在高温或长时间使用下存在超标的风险,因而需要严格控制材料制品与食物接触的时间和温度。所建立的方法快速简单、经济环保,可满足企业日常检验的要求。 展开更多
关键词 火焰原子吸收光谱法 食品接触材料 水性油墨 印刷纸杯 重金属 溶出量
下载PDF
邻二氮菲荧光分光光度法测定粉状食品中铁的含量
15
作者 张文 向清祥 +3 位作者 杨孝容 庾童海 陈婷婷 宋成 《理化检验(化学分册)》 CAS CSCD 北大核心 2024年第7期697-702,共6页
基于在三羟甲基氨基甲烷溶液中,邻二氮菲与Fe^(2+)形成的络合物使邻二氮菲荧光强度减弱的原理,提出了题示方法。取1.0000 g样品,加入8.00 mL硝酸和5.00 mL 30%(质量分数)过氧化氢溶液,静置过夜后加热至近干,加入5.00 mL硝酸和5.00 mL高... 基于在三羟甲基氨基甲烷溶液中,邻二氮菲与Fe^(2+)形成的络合物使邻二氮菲荧光强度减弱的原理,提出了题示方法。取1.0000 g样品,加入8.00 mL硝酸和5.00 mL 30%(质量分数)过氧化氢溶液,静置过夜后加热至近干,加入5.00 mL硝酸和5.00 mL高氯酸,继续加热至近干,加入2.50 mL 1.0 mol·L^(−1)硝酸溶液溶解,用水定容至25 mL。取一定体积上述溶液(蛋白质粉固态饮料样品取1.00 mL、婴儿配方奶粉样品取1.50 mL和面粉样品取2.00 mL),加入1.00 mL 50.0 g·L^(−1)盐酸羟胺溶液,静置2 min,加入4.00 mL 5.00×10^(-4)mol·L^(−1)邻二氮菲工作溶液,混匀后加入2.50 mL1.0 mol·L^(−1)三羟甲基氨基甲烷溶液(pH 8.5),用水定容至25 mL,静置10 min后在激发波长323 nm下,测量体系在363 nm处的荧光强度。结果表明:Fe^(3+)质量浓度在1.3440 mg·L^(−1)以内与邻二氮菲的荧光强度下降值呈线性关系,检出限(3s/k)为0.009 mg·L^(−1)。方法用于粉状食品中铁含量的测定,本底值的相对标准偏差(RSD,n=5)为1.7%~7.6%;按标准加入法进行回收试验,回收率为94.6%~99.9%,测定值的RSD(n=5)为1.5%~4.1%。经F检验和t检验分析,本方法与紫外-可见分光光度法、火焰原子吸收光谱法测定结果无显著性差异,但本方法的灵敏度更高。 展开更多
关键词 邻二氮菲 荧光分光光度法 紫外-可见分光光度法 火焰原子吸收光谱法
下载PDF
薯类中营养元素锌、钾的FAAS测定研究 被引量:15
16
作者 刘文涵 陆国权 +1 位作者 吴君华 金美梅 《光谱实验室》 CAS CSCD 2001年第2期159-162,共4页
研究了用火焰原子吸收分光光度法测定甘薯中的微量元素锌、钾的方法 ,采用高温灰化法对样品进行处理 ,并对 4 0多种不同品种和不同种植地区的甘薯进行了实样测定和含量差异比较。测定回收率在91.9%— 10 8.0 %之间。取得了令人满意的结果。
关键词 火焰原子吸收法 甘薯 测定 薯类食品 测定
下载PDF
澳洲坚果果仁中4种关键微量元素的FAAS法测定 被引量:8
17
作者 柳觐 倪书邦 +2 位作者 贺熙勇 牛迎凤 李开雄 《中国农学通报》 CSCD 2014年第1期153-156,共4页
为探明澳洲坚果果仁中Fe、Mn、Cu、Zn 4种关键微量元素的含量及其测定方法,运用火焰原子吸收分光光度法(FAAS),采用干灰化、混酸消解、微波消解3种不同样品消解方式,对4个澳洲坚果品种果仁中Fe、Mn、Cu、Zn的含量进行了测定。结果表明:F... 为探明澳洲坚果果仁中Fe、Mn、Cu、Zn 4种关键微量元素的含量及其测定方法,运用火焰原子吸收分光光度法(FAAS),采用干灰化、混酸消解、微波消解3种不同样品消解方式,对4个澳洲坚果品种果仁中Fe、Mn、Cu、Zn的含量进行了测定。结果表明:Fe、Cu经3种不同消化方式处理后的含量测定结果无显著差异;而Mn、Zn经微波消解处理后的测定值虽然略高于干灰化和混酸消解2种方式,但未达到显著水平;澳洲坚果果仁中4种微量元素的含量为Mn>Fe>Zn>Cu,其中Mn元素含量在品种间的变异较大;在4个供试品种中,‘云澳51号’的Fe含量为最高,而‘云澳58号’的Mn、Cu、Zn 3种微量元素含量均为最高。3种样品消解方式均可用于澳洲坚果果仁微量元素含量的FAAS法测定。 展开更多
关键词 澳洲坚果 火焰原子吸收分光光度法 微量元素
下载PDF
微波消解-FAAS法测定大鼠肝脏中的微量元素 被引量:10
18
作者 赵爱东 翟学良 刘敬泽 《光谱学与光谱分析》 SCIE EI CAS CSCD 北大核心 2005年第11期1893-1894,共2页
研究了采用微波消解样品,利用火焰原子吸收分光光度法(FAAS)测定了大鼠肝脏中的钙、锌、铜、镁、铁.考察了微波消解条件对分析结果的影响,同时选择了火焰原子吸收分光光度法测定的最佳条件.实验结果表明,与传统的湿法消解样品相比,该方... 研究了采用微波消解样品,利用火焰原子吸收分光光度法(FAAS)测定了大鼠肝脏中的钙、锌、铜、镁、铁.考察了微波消解条件对分析结果的影响,同时选择了火焰原子吸收分光光度法测定的最佳条件.实验结果表明,与传统的湿法消解样品相比,该方法操作简便、快速、样品消解完全,空白值低,选择性好,准确度和精确度都能满足分析要求.利用该法对大鼠肝脏中的微量元素进行了分析,测定结果令人满意.方法回收率在96%~103%,相对标准偏差为1.0%~2.6%. 展开更多
关键词 微波消解 测定 微量元素 火焰原子吸收法
下载PDF
FAAS直接法测定环境和生物试样中Zn、Pb和Cd 被引量:4
19
作者 彭荣飞 唐宝英 +2 位作者 曾尊祥 杨秀环 张展霞 《光谱学与光谱分析》 SCIE EI CAS CSCD 北大核心 2001年第1期77-80,共4页
本文系统研究了海水、土壤、沉积物和生物中Cd、Pb和Zn用火焰原子吸收直接法测定时的干扰与背景校正。由于这些物质基体中含有大量Al、Na、K、Ca、Mg、Fe等元素 ,在火焰中形成MX、MO和MOH分子光谱与分析元素线重叠 ,经背景校正后可获得... 本文系统研究了海水、土壤、沉积物和生物中Cd、Pb和Zn用火焰原子吸收直接法测定时的干扰与背景校正。由于这些物质基体中含有大量Al、Na、K、Ca、Mg、Fe等元素 ,在火焰中形成MX、MO和MOH分子光谱与分析元素线重叠 ,经背景校正后可获得更准确的结果和更好的回收率 。 展开更多
关键词 faas 火焰原子吸收法 环境试样 生物试样 测定
下载PDF
FAAS法测定原生态硒米中的微量元素铁和镍 被引量:9
20
作者 蒋天智 唐文华 +2 位作者 张文华 周昊 杨红芸 《安徽农业科学》 CAS 北大核心 2010年第6期2770-2771,共2页
[目的]测定黔东南苗族侗族自治州原生态丹寨精硒米中微量元素铁和镍的含量。[方法]采用正交试验优化仪器最佳工作条件,湿法消解硒米样品,火焰原子吸收光谱法(FAAS)测定微量元素铁和镍。[结果]原生态丹寨精硒米中微量元素铁和镍的含量分... [目的]测定黔东南苗族侗族自治州原生态丹寨精硒米中微量元素铁和镍的含量。[方法]采用正交试验优化仪器最佳工作条件,湿法消解硒米样品,火焰原子吸收光谱法(FAAS)测定微量元素铁和镍。[结果]原生态丹寨精硒米中微量元素铁和镍的含量分别为8.00和0.50 mg/kg。[结论]该研究方法操作简便,灵敏度高,检出限低。 展开更多
关键词 硒米 原生态 原子吸收光谱法 微量元素
下载PDF
上一页 1 2 107 下一页 到第
使用帮助 返回顶部