期刊文献+
共找到1篇文章
< 1 >
每页显示 20 50 100
On-line Preconcentration and Determination of Trace Metals in Water Samples by Flow Injection Combined with Flame Atomic Absorption Spectrometry via Calix[4]arene Carboxylic Acid Packed Micro-column 被引量:1
1
作者 GUO Da-wang, ZHAO Xiao-wei, JIA Qiong and ZHOU Wei-hong College of Chemistry, Jilin University, Changchun 130012, P. R. China 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2012年第1期26-30,共5页
An adsorbent calix[4]arene carboxylic acid was employed as the adsorption material for on-line flow in jection(FI) micro-column preconcentration coupled with flame atomic absorption spectrometry(FAAS) determinatio... An adsorbent calix[4]arene carboxylic acid was employed as the adsorption material for on-line flow in jection(FI) micro-column preconcentration coupled with flame atomic absorption spectrometry(FAAS) determination of trace heavy metals(Cu, Pb, Co, Ni and Cd). Parameters such as the pH, loading time and flow rate of sample, and the concentration, volume and flow rate of eluent were optimized. The enrichment factors are 50.0, 56.5, 11.6, 12.1 and 19.1 for Cu, Pb, Co, Ni, and Cd, respectively, and a sample throughput of 20 h–1 was obtained. The limits of de tection for Cu, Pb, Co, Ni, and Cd were in a range of 1.56―3.91 μg/L, and the relative standard deviations(RSDs) were less than 2.76%(n=7). Furthermore, the proposed method was successfully applied to the determination of Cu, Pb, Co, Ni, and Cd in certified reference materials and various water samples. 展开更多
关键词 arene carboxylic acid PRECONCENTRATION Flow injection Metal ion flame atomic absorptionspectrometry(FAAS)
下载PDF
上一页 1 下一页 到第