An adsorbent calix[4]arene carboxylic acid was employed as the adsorption material for on-line flow in jection(FI) micro-column preconcentration coupled with flame atomic absorption spectrometry(FAAS) determinatio...An adsorbent calix[4]arene carboxylic acid was employed as the adsorption material for on-line flow in jection(FI) micro-column preconcentration coupled with flame atomic absorption spectrometry(FAAS) determination of trace heavy metals(Cu, Pb, Co, Ni and Cd). Parameters such as the pH, loading time and flow rate of sample, and the concentration, volume and flow rate of eluent were optimized. The enrichment factors are 50.0, 56.5, 11.6, 12.1 and 19.1 for Cu, Pb, Co, Ni, and Cd, respectively, and a sample throughput of 20 h–1 was obtained. The limits of de tection for Cu, Pb, Co, Ni, and Cd were in a range of 1.56―3.91 μg/L, and the relative standard deviations(RSDs) were less than 2.76%(n=7). Furthermore, the proposed method was successfully applied to the determination of Cu, Pb, Co, Ni, and Cd in certified reference materials and various water samples.展开更多
基金Supported by the Fund of State Key Laboratory of Rare Earth Resource Utilization, Changchun Institute of Applied Chemi-stry, Chinese Academy of Sciences(No.RERU2011006)
文摘An adsorbent calix[4]arene carboxylic acid was employed as the adsorption material for on-line flow in jection(FI) micro-column preconcentration coupled with flame atomic absorption spectrometry(FAAS) determination of trace heavy metals(Cu, Pb, Co, Ni and Cd). Parameters such as the pH, loading time and flow rate of sample, and the concentration, volume and flow rate of eluent were optimized. The enrichment factors are 50.0, 56.5, 11.6, 12.1 and 19.1 for Cu, Pb, Co, Ni, and Cd, respectively, and a sample throughput of 20 h–1 was obtained. The limits of de tection for Cu, Pb, Co, Ni, and Cd were in a range of 1.56―3.91 μg/L, and the relative standard deviations(RSDs) were less than 2.76%(n=7). Furthermore, the proposed method was successfully applied to the determination of Cu, Pb, Co, Ni, and Cd in certified reference materials and various water samples.