期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Removing paint from a metal substrate using a flattened top laser 被引量:2
1
作者 施曙东 李伟 +6 位作者 杜鹏 王萌 宋峰 刘淑静 陈念江 赵鸿 杨文是 《Chinese Physics B》 SCIE EI CAS CSCD 2012年第10期295-301,共7页
In this paper,we investigate laser cleaning using a flattened top laser to remove paint coating from a metal substrate.Under the irradiation of a flattened top laser,the coating paint of the metal substrate can be rem... In this paper,we investigate laser cleaning using a flattened top laser to remove paint coating from a metal substrate.Under the irradiation of a flattened top laser,the coating paint of the metal substrate can be removed efficiently by laser induced ablation,stress,and displacement force.The temperature distribution,stress,and displacement are calculated in the coating layer and substrate using finite element analysis.The effects of a Gaussian laser and a flattened top laser and the results of different diameters of laser spot are compared.The investigation shows that the flattened top laser can reduce the substrate damage and enhance the cleaning efficiency.This method meets the need of large area industrial cleaning applications by optimizing the flattened top laser parameters. 展开更多
关键词 laser cleaning laser ablation finite element method flattened top laser beam
下载PDF
A Sensitivity Dosimetry Study of the Setup Uncertainties during Machine Commissioning and Annual QA 被引量:1
2
作者 Vi Nhan Nguyen Brian Wang Chengyu Shi 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2016年第4期329-347,共19页
This study is to investigate three common potential setup uncertainties during Linac commissioning and annual QA and to evaluate how these uncertainties propagate into the quality of beam profiles and patient dosimetr... This study is to investigate three common potential setup uncertainties during Linac commissioning and annual QA and to evaluate how these uncertainties propagate into the quality of beam profiles and patient dosimetry using gamma analysis. Three uncertainty scenarios were purposely introduced for gantry position tilted from 0&ring;- 3&ring;(scenario 1), isocenter position misaligned from 0 - 6 mm (scenario 2) and SAD changed from 99.5 - 103 cm (scenario 3). A 60 × 60 × 60 cm<sup>3</sup> water phantom cube was created to replicate a 3D water tank in VarianEclipse (V.11) treatment planning system (Varian Medical Systems, Palo Alto, CA). For each scenario, beam data profiles (crossline and diagonal) and PDD curves were calculated at different field sizes and depths for three energies: 6 MV, 6 MV-FFF and 10 MV-FFF. Gamma analysis method was used to compare a total of 263 profiles to baseline using a 1%/1mm parameter with 90% gamma passing rate criteria. For scenario 1, a ≥90% gamma passing rate and ≤1% dose difference were seen on both crossline and diagonal profiles, and PDD curves for gantry tilted up to 2&ring;. For 3&ring;degree tilt, the gamma passing rate decreased to ≤90% at depth of ≥20 cm for 6MV/6MV-FFF and depth of ≥12 cm for 10MV-FFF. For scenario 2, a ≤90% gamma passing rate and ≥1% dose difference were seen at depths from d<sub>max</sub> to 20 cm for all energies. For depths ≥20 cm, mostly ≥90% gamma passing rate and ≤1% dose difference were seen. For scenario 3, a ≥90% gamma passing rate and ≤1% dose difference were seen on ≤4 mm isocenter misalignments for all energies. In summary, gamma analysis of the beam profiles is a very sensitive test for SAD deviation scenarios and can reveal issues of sub millimeter setup uncertainty. However, it is not as sensitive for isocenter misalignment scenarios. The test is also more sensitive for FFF beams than flattening filter beams. 展开更多
关键词 Linac Commissioning Annual QA Gamma Analysis TG 142 Flattening Filter and Flattening Filter Free beams
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部