期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Active injection protection scheme for flexible HVDC grids based on amplitude of input impedance 被引量:11
1
作者 Jinghan He Keao Chen +2 位作者 Meng Li Yong Tang Ming Nie 《Global Energy Interconnection》 EI CAS CSCD 2021年第6期531-542,共12页
High-voltage direct current(HVDC)grids require fast and reliable protection of the DC lines.The performance of traditional protection schemes is easily impaired by the limitations of the boundary condition and nonline... High-voltage direct current(HVDC)grids require fast and reliable protection of the DC lines.The performance of traditional protection schemes is easily impaired by the limitations of the boundary condition and nonlinearity from the control of converters.One of the key technologies for flexible HVDC grids is the half-bridge modular multilevel converter(HB-MMC).Considering the high controllability of HB-MMC,this study proposes an active injection protection scheme to improve the reliability and sensitivity of the HVDC grid protection.The HB-MMC is used to inject a sinusoidal characteristic signal,at the specified frequency,into the DC lines.Then,the voltage and current at the specified frequency are extracted using the Prony algorithm to calculate the input impedance,which is used for the identification of internal and external faults.The active injection protection scheme was simulated for various cases in the simulation software Power Systems Computer Aided Design.The simulation results indicate that the proposed protection scheme is highly reliable and can overcome transition resistance. 展开更多
关键词 HB-MMC flexible hvdc grids Active injection Characteristic signal Input impedance
下载PDF
DC faults ride-through capability analysis of Full-Bridge MMC-MTDC System 被引量:38
2
作者 ZHAO ChengYong XU JianZhong LI Tan 《Science China(Technological Sciences)》 SCIE EI CAS 2013年第1期253-261,共9页
Full-Bridge Modular Multilevel Converter(FBMMC) has strong ability to ride through serious DC faults,thus it is very suitable for multi-terminal flexible HVDC applications.However,no references have reported the locat... Full-Bridge Modular Multilevel Converter(FBMMC) has strong ability to ride through serious DC faults,thus it is very suitable for multi-terminal flexible HVDC applications.However,no references have reported the locating and isolating of DC faults and corresponding DC faults ride-through capability evaluation index.This paper introduces the topology mechanism of FBMMC and its loss reduction operation mode,theoretically certifies that the universal decoupled control strategy of Voltage Source Converter(VSC) and the similar modulation strategies of Half-Bridge MMC(HBMMC) can be applied to FBMMC for constructing complete closed-loop control system.On the basis of the existing DC faults locating and isolating schemes of 2-level VSC based Multi-Terminal HVDC(VSC-MTDC) system and the particularity of FBMMC,this paper proposes the DC faults wire selection "handshaking" method of the FBMMC-MTDC system,and proposes the DC Fault Ride-Through Capability Index(DFRTI) for evaluating the DC faults suppressing capability of the VSC-MTDC systems,including FBMMC-MTDC.Simulations of FBMMC-MTDC in PSCAD/EMTDC validate the correctness and effectiveness of the proposed control strategy and evaluation index. 展开更多
关键词 FULL-BRIDGE modular multilevel converter multi-terminal flexible hvdc handshaking method DC fault ride-through capability index(DFRTI)
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部