To address the low accuracy and stability when applying classical control theory in distribution networks with distributed generation,a control method involving flexible multistate switches(FMSs)is proposed in this st...To address the low accuracy and stability when applying classical control theory in distribution networks with distributed generation,a control method involving flexible multistate switches(FMSs)is proposed in this study.This approach is based on an improved double-loop recursive fuzzy neural network(DRFNN)sliding mode,which is intended to stably achieve multiterminal power interaction and adaptive arc suppression for single-phase ground faults.First,an improved DRFNN sliding mode control(SMC)method is proposed to overcome the chattering and transient overshoot inherent in the classical SMC and reduce the reliance on a precise mathematical model of the control system.To improve the robustness of the system,an adaptive parameter-adjustment strategy for the DRFNN is designed,where its dynamic mapping capabilities are leveraged to improve the transient compensation control.Additionally,a quasi-continuous second-order sliding mode controller with a calculus-driven sliding mode surface is developed to improve the current monitoring accuracy and enhance the system stability.The stability of the proposed method and the convergence of the network parameters are verified using the Lyapunov theorem.A simulation model of the three-port FMS with its control system is constructed in MATLAB/Simulink.The simulation result confirms the feasibility and effectiveness of the proposed control strategy based on a comparative analysis.展开更多
This paper develops a flexible power regulation and limitation strategy of voltage source inverters(VSIs)under unbalanced grid faults.When the classical power theory is used under unbalanced grid faults,the power osci...This paper develops a flexible power regulation and limitation strategy of voltage source inverters(VSIs)under unbalanced grid faults.When the classical power theory is used under unbalanced grid faults,the power oscillations and current distortions are inevitable.In the proposed strategy,the extended power theory is introduced to compute the power feedbacks together with the classical power theory.Based on the combination of the classical and extended power theory,the proposed strategy can achieve the sinusoidal current provision and the flexible regulation between three common targets,i.e.,constant active power,balanced current,and constant reactive power.Meanwhile,the proposed strategy is associated with a power limiter,which is capable to keep the currents under the pre-defined threshold and to compute the maximum apparent power for better utilization of the inverter capacity.With this power limiter,the rated inverter capacity is fully used for both the active and reactive power provisions under unbalanced grid faults.Using the proposed power regulation and limitation,the VSI can avoid overcurrent tripping and flexibly regulate its power under unbalanced grid faults.All the conclusions are verified by the real-time hardware-in-loop tests.展开更多
Smart grid(SG)brings convenience to users while facing great chal-lenges in protecting personal private data.Data aggregation plays a key role in protecting personal privacy by aggregating all personal data into a sin...Smart grid(SG)brings convenience to users while facing great chal-lenges in protecting personal private data.Data aggregation plays a key role in protecting personal privacy by aggregating all personal data into a single value,preventing the leakage of personal data while ensuring its availability.Recently,a flexible subset data aggregation(FSDA)scheme based on the Pail-lier homomorphic encryption was first proposed by Zhang et al.Their scheme can dynamically adjust the size of each subset and obtain the aggregated data in the corresponding subset.In this paper,firstly,an efficient attack with both theorems proving and experimentative verification is launched.We find that in a specific scenario where the encrypted data constructed by a smart meter(SM)exceeds the size of one Paillier ciphertext,the malicious fog node(FN)may use the received ciphertext to obtain the reading of the SM.Secondly,to avoid the possibility of privacy disclosure under certain circumstances,additional hash functions are added to the individual encryption process.In addition,fault tolerance is very important to aggregation schemes in practical scenarios.In most of the current schemes,once some SMs failed,then they will not work.As far as we know,there is no multi-subset aggregation scheme both supports flexible subset data aggregation and fault tolerance.Finally,we construct the first secure flexible subset data aggregation(SFSDA)scheme with fault tolerance by combining the fault tolerance method with the flexible multi-subset aggregation,where FN enables the control server(CS)to finally decrypt the aggregated ciphertext by recovering equivalent ciphertexts when some SMs fail to submit their ciphertexts.Experiments show that our SFSDA scheme keeps the efficiency in implementing a flexible multi-subset aggregation function,and only has a small delay in implementing fault-tolerant data aggregation.展开更多
Based on the system of electric power supply for flexible manufacturing systems (FMS), a study has been carried out on the intelligent safety examination, monitoring and maintenance of its running environment. On the ...Based on the system of electric power supply for flexible manufacturing systems (FMS), a study has been carried out on the intelligent safety examination, monitoring and maintenance of its running environment. On the basis of the specific feature of the power supply network of an FMS, real time monitoring system of the power supply network and the fault diagnostic expert system for the power equipment have been designed. This system can diagnose not only definite fault phenomena, but also fuzzy, uncertain fault phenomena as well. Fault diagnostic knowledge base for the power equipment has been founded hierarchy architecture model and the method of fault tree analysis. Feasibility of this system has been proved by computer simulation.展开更多
Voltage sags in power system may lead to serious problems such as the off-grid of distributed generation and electrical equipment failures.As a novel type of power electronic equipment,a flexible multi-state switch(FM...Voltage sags in power system may lead to serious problems such as the off-grid of distributed generation and electrical equipment failures.As a novel type of power electronic equipment,a flexible multi-state switch(FMSS)is capable to support the voltage during the grid faults.In this paper,a voltage control strategy to support the voltage in a distribution network is proposed by introducing three-port FMSS.The positive-negative-sequence compensation(PNSC)scheme is adopted to control the active and reactive current.This control scheme eliminates active power oscillations at the port of voltage sags and reduces coupling oscillations of other ports.Based on the characteristics of the voltage support under PNSC scheme,two voltage support strategies are proposed.A proportional-integral controller is introduced to provide the reactive power references,which eliminates the errors when estimating the grid voltage and impedance.A current limiting scheme is adopted to keep the port current in a safe range by adjusting the active and reactive power references.The voltage support strategies in two different voltage sags are simulated,and results show the feasibility and effectiveness of the proposed control strategies.展开更多
With continuously increasing of photovoltaic (PV) plant’s penetration, it has become a critical issue to improve the fault ride-through capability of PV plant. This paper refers to the German grid code, and the PV sy...With continuously increasing of photovoltaic (PV) plant’s penetration, it has become a critical issue to improve the fault ride-through capability of PV plant. This paper refers to the German grid code, and the PV system is controlled to keep grid connected, as well as inject reactive current to grid when fault occurs. The mathematical model of PV system is established and the fault characteristic is studied with respect to the control strategy. By analyzing the effect of reactive power supplied by the PV system to the point of common coupling (PCC) voltage, this paper proposes an adaptive voltage support control strategy to enhance the fault ride-through capability of PV system. The control strategy fully utilizes the PV system’s capability of voltage support and takes the safety of equipment into account as well. At last, the proposed control strategy is verified by simulation.展开更多
In order to ensure power system stability, modern wind turbines are required to be able to endure deep voltage dips. The specifications that determine the voltage dip versus time are called fault r/de-through (FRT) ...In order to ensure power system stability, modern wind turbines are required to be able to endure deep voltage dips. The specifications that determine the voltage dip versus time are called fault r/de-through (FRT) requirements. The purpose of this paper is not only to examine the FRT behavior of a full-power converter wind turbine but also to combine the power system viewpoint to the studies. It is not enough for the turbine to be FRT capable; the loss of mains (LOM) protection of the turbine must also be set to allow the FRT. Enabling FRT, however, means that the LOM protection settings must be loosen, which may sometimes pose a safety hazard. This article introduces unique real-time simulation environment and proposes an FRT method for a wind turbine that also takes the operation of LOM protection relay into account. Simulations are carried out using the simulation environment and results show that wind turbine is able to ride-through a symmetrical power system fault.展开更多
The installation of wind energy has increased rapidly around the world. The grid codes about the wind energy require wind turbine (WT) has the ability of fault (or low voltage) ride-through (FRT). To study the FRT ope...The installation of wind energy has increased rapidly around the world. The grid codes about the wind energy require wind turbine (WT) has the ability of fault (or low voltage) ride-through (FRT). To study the FRT operation of the wind farms, three methods were discussed. First, the rotor short current of doubly-fed induction generator (DFIG) was limited by introducing a rotor side protection circuit. Second, the voltage of DC bus was limited by a DC energy absorb circuit. Third, STATCOM was used to increase the low level voltages of the wind farm. Simulation under MATLAB was studied and the corresponding results were given and discussed. The methods proposed in this paper can limit the rotor short current and the DC voltage of the DFIG WT to some degree, but the voltage support to the power system during the fault largely depend on the installation place of STATCOM.展开更多
Shear-type structures are common structural forms in industrial and civil buildings,such as concrete and steel frame structures.Fault diagnosis of shear-type structures is an important topic to ensure the normal use o...Shear-type structures are common structural forms in industrial and civil buildings,such as concrete and steel frame structures.Fault diagnosis of shear-type structures is an important topic to ensure the normal use of structures.The main drawback of existing damage assessment methods is that they require accurate structural finite element models for damage assessment.However,for many shear-type structures,it is difficult to obtain accurate FEM.In order to avoid finite elementmodeling,amodel-freemethod for diagnosing shear structure defects is developed in this paper.This method only needs to measure a few low-order vibration modes of the structure.The proposed defect diagnosis method is divided into two stages.In the first stage,the location of defects in the structure is determined based on the difference between the virtual displacements derived from the dynamic flexibility matrices before and after damage.In the second stage,damage severity is evaluated based on an improved frequency sensitivity equation.Themain innovations of this method lie in two aspects.The first innovation is the development of a virtual displacement difference method for determining the location of damage in the shear structure.The second is to improve the existing frequency sensitivity equation to calculate the damage degree without constructing the finite elementmodel.Thismethod has been verified on a numerical example of a 22-story shear frame structure and an experimental example of a three-story steel shear structure.Based on numerical analysis and experimental data validation,it is shown that this method only needs to use the low-order modes of structural vibration to diagnose the defect location and damage degree,and does not require finite element modeling.The proposed method should be a very simple and practical defect diagnosis technique in engineering practice.展开更多
Modeling and validation of full power converter wind turbine models with field measurement data are rarely reported in papers. In this paper an aggregated generic dynamic model of the wind farm consisting of full powe...Modeling and validation of full power converter wind turbine models with field measurement data are rarely reported in papers. In this paper an aggregated generic dynamic model of the wind farm consisting of full power converter wind turbines is composed and the model validation based on actual field measurements is performed. The paper is based on the measurements obtained from the real short circuit test applied to connection point of observed wind farm. The presented approach for validating the composed model and fault ride-through (FRT) capability for the whole wind park is unique in overall practice and its significance and importance is described and analyzed.展开更多
During dislocation,a tunnel crossing the active fault will be damaged to varying degrees due to its permanent stratum displacement.Most previous studies did not consider the influence of the tunnel’s deep burial and ...During dislocation,a tunnel crossing the active fault will be damaged to varying degrees due to its permanent stratum displacement.Most previous studies did not consider the influence of the tunnel’s deep burial and the high in-situ stress,so the results were not entirely practical.In this paper,the necessity of solving the anti-dislocation problem of deep-buried tunnels is systemically discussed.Through the model test of tunnels across active faults,the differences in failures between deep-buried tunnels and shallow-buried tunnels were compared,and the dislocation test of deep-buried segmental tunnels was carried out to analyze the external stress change,lining strain,and failure mode of tunnels.The results are as follows.(1)The overall deformation of deep-buried and shallow-buried tunnels is both Sshaped.The failure mode of deep-buried tunnels is primarily characterized by shear and tensile failure,resulting in significant compressive deformation and a larger damaged area.In contrast,shallow-buried tunnels mainly experience shear failure,with the tunnel being sheared apart at the fault crossing,leading to more severe damage.(2)After the segmental structure design of the deep-buried tunnel,the “S”deformation pattern is transformed into a “ladder”pattern,and the strain of the tunnel and the peak stress of the external rock mass are reduced;therefore,damages are significantly mitigated.(3)Through the analysis of the distribution of cracks in the tunnel lining,it is found that the tunnel without a segmental structure design has suffered from penetrating failure and that cracks affect the entire lining.The cracks in a flexible segmental tunnel affect about 66.6% of the entire length of the tunnel,and cracks in a tunnel with a short segmental tunnel only affect about 33.3% of the entire length of the tunnel.Therefore,a deep-buried tunnel with a short segmental tunnel can yield a better anti-dislocation effect.(4)By comparing the shallow-buried segmental tunnel in previous studies,it is concluded that the shallow-buried segmental tunnel will also suffer from deformation outside the fault zone,while the damages to the deep-buried segmental tunnel are concentrated in the fault zone,so the anti-dislocation protection measures of the deep-buried tunnel shall be provided mainly in the fault zone.The results of the above study can provide theoretical reference and technical support for the design and reinforcement measures of the tunnel crossing active fault under high in-situ stress conditions.展开更多
This paper studies a robust fault compensation and vibration suppression problem of flexible hypersonic vehicles.The controlled plant is represented by a cascade system composed of a nonlinear Ordinary Differential Eq...This paper studies a robust fault compensation and vibration suppression problem of flexible hypersonic vehicles.The controlled plant is represented by a cascade system composed of a nonlinear Ordinary Differential Equation(ODE)and an Euler-Bernoulli Beam Equation(EBBE),in which the vibration dynamics is coupled with the rigid dynamics and suffers from distributed faults.A state differential transformation is introduced to transfer distributed faults to an EBBE boundary and a longitudinal dynamics is refined by utilizing T-S fuzzy IF-THEN rules.A novel T-S fuzzy based fault-tolerant control algorithm is developed and related stability conditions are established.The robust exponential stability and well-posedness are proved by using the modified l_(0)-semigroup based Lyapunov direct approach.A simulation study on the longitudinal dynamics of flexible hypersonic vehicles effectively verifies the validity of the developed theoretical results.展开更多
For the tunnel crossing active fault,the damage induced by fault movement is always serious.To solve such a problem,a detailed anti-faulting tunnel design process for Urumqi subway line 2 was introduced,and seven thre...For the tunnel crossing active fault,the damage induced by fault movement is always serious.To solve such a problem,a detailed anti-faulting tunnel design process for Urumqi subway line 2 was introduced,and seven three-dimensional elastic-plastic finite element models were established.The anti-faulting design process included three steps.First,the damage of tunnel lining from different locations of fault rupture surfaces was analyzed.Then,the analysis of the effect on tunnel buried depth was given.Finally,the effect of the disaster mitigation method on the flexible joint was verified and the location of the flexible joint was discussed.The results show that when the properties of surrounding rock at the tunnel bottom grows soft,the tunnel deformation curve is smoother and tunnel damage induced by fault movement is less serious.The vertical displacement change ratio of secondary linings along the tunnel axis may be the main factor to cause shear damage to the tunnel.The interface between the hanging wall and fracture zone is defined as the most adverse fault rupture surface.The tunnel damage was reduced with the decrease in the tunnel buried depth as more energy was dissipated by overburden soil and the differential uplift zone of soil became more diffuse.The method of the flexible joint can reduce the tunnel damage significantly and the disaster mitigation effect of different locations on the flexible joint is different.The tunnel damage is reduced by the greatest degree when the flexible joint is located on the fault rupture surface.展开更多
This paper presents a scheme of fault diagnosis for flexible satellites during orbit maneuver. The main contribution of the paper is related to the design of the nonlinear input observer which can avoid false alarm ar...This paper presents a scheme of fault diagnosis for flexible satellites during orbit maneuver. The main contribution of the paper is related to the design of the nonlinear input observer which can avoid false alarm arising from the disturbance from orbit control force. The effects of orbit control force on the fault diagnosis system for satellite attitude control systems, including the disturbing torque caused by the misalignments and the model uncertainty caused by the fuel consumed, are discussed, where standard Lu- enberger observer cannot work well. Then the nonlinear unknown input observer is proposed to decouple faults from disturbance, Besides, a linear matrix inequality approach is adopted to reduce the effect of nonlinear part and model uncertainties on the observer. The numerical and semi-physical simulation demonstrates the effectiveness of the proposed observer for the fault diagnosis system of the satellite during orbit maneuver.展开更多
It is assumed that a pipeline is laid through a vertical fault fracture zone, and is excited by seismic ground motion modelled as stationary stochastic process. For horizontal incidence of waves, the cross-PSD (Power...It is assumed that a pipeline is laid through a vertical fault fracture zone, and is excited by seismic ground motion modelled as stationary stochastic process. For horizontal incidence of waves, the cross-PSD (Power Spectral Density) function is developed using wave propagation theory, while for vertical incidence of waves the cross-PSD function is composed by auto-PSD model, coherence model and site response model. As the seismic input, the eross-PSD function is used to calculate the the axial and lateral seismic responses of underground pipeline through the fracture zone. The results show that the incident directions of seismic waves, width and soil property of the fracture zone have great influence on underground pipeline. It is suggested that the flexible joints with appropriate stiffness should be added into the pipeline near the interfaces between the fracture zone and the surrounded media.展开更多
Determining the fault location using conventional impedance based distance relay in the presence of FACTS controllers is a challenging task in a transmission line. A new distance protection method is developed to loca...Determining the fault location using conventional impedance based distance relay in the presence of FACTS controllers is a challenging task in a transmission line. A new distance protection method is developed to locate the fault in a transmission line compensated with STATCOM with simple calculations. The proposed protection method considers the STATCOM injected/absorbed current to correct the fault loop apparent impedance and accordingly calculates the actual distance to the fault location. The comprehensive equations needed for apparent impedance calculation are also outlined and the performance is evaluated and tested with a typical 400 KV transmission system for different fault types and locations using MATLAB/SIMULINK software. The evaluation results indicate that the new protection method effectively estimates the exact fault location by mitigating the impact of STATCOM on distance relay performance with error less than 0.3%.展开更多
基金the Natural Science Foundation of Fujian,China(No.2021J01633).
文摘To address the low accuracy and stability when applying classical control theory in distribution networks with distributed generation,a control method involving flexible multistate switches(FMSs)is proposed in this study.This approach is based on an improved double-loop recursive fuzzy neural network(DRFNN)sliding mode,which is intended to stably achieve multiterminal power interaction and adaptive arc suppression for single-phase ground faults.First,an improved DRFNN sliding mode control(SMC)method is proposed to overcome the chattering and transient overshoot inherent in the classical SMC and reduce the reliance on a precise mathematical model of the control system.To improve the robustness of the system,an adaptive parameter-adjustment strategy for the DRFNN is designed,where its dynamic mapping capabilities are leveraged to improve the transient compensation control.Additionally,a quasi-continuous second-order sliding mode controller with a calculus-driven sliding mode surface is developed to improve the current monitoring accuracy and enhance the system stability.The stability of the proposed method and the convergence of the network parameters are verified using the Lyapunov theorem.A simulation model of the three-port FMS with its control system is constructed in MATLAB/Simulink.The simulation result confirms the feasibility and effectiveness of the proposed control strategy based on a comparative analysis.
基金This work is supported by the National Key Research and Development Program of China under Project 2021YFB2601600。
文摘This paper develops a flexible power regulation and limitation strategy of voltage source inverters(VSIs)under unbalanced grid faults.When the classical power theory is used under unbalanced grid faults,the power oscillations and current distortions are inevitable.In the proposed strategy,the extended power theory is introduced to compute the power feedbacks together with the classical power theory.Based on the combination of the classical and extended power theory,the proposed strategy can achieve the sinusoidal current provision and the flexible regulation between three common targets,i.e.,constant active power,balanced current,and constant reactive power.Meanwhile,the proposed strategy is associated with a power limiter,which is capable to keep the currents under the pre-defined threshold and to compute the maximum apparent power for better utilization of the inverter capacity.With this power limiter,the rated inverter capacity is fully used for both the active and reactive power provisions under unbalanced grid faults.Using the proposed power regulation and limitation,the VSI can avoid overcurrent tripping and flexibly regulate its power under unbalanced grid faults.All the conclusions are verified by the real-time hardware-in-loop tests.
基金supported by National Natural Science Foundation of China (Grant Nos.62102452,62172436)Natural Science Foundation of Shaanxi Province (No.2023-JCYB-584)+1 种基金Innovative Research Team in Engineering University of PAP (KYTD201805)Engineering University of PAP’s Funding for Key Researcher (No.KYGG202011).
文摘Smart grid(SG)brings convenience to users while facing great chal-lenges in protecting personal private data.Data aggregation plays a key role in protecting personal privacy by aggregating all personal data into a single value,preventing the leakage of personal data while ensuring its availability.Recently,a flexible subset data aggregation(FSDA)scheme based on the Pail-lier homomorphic encryption was first proposed by Zhang et al.Their scheme can dynamically adjust the size of each subset and obtain the aggregated data in the corresponding subset.In this paper,firstly,an efficient attack with both theorems proving and experimentative verification is launched.We find that in a specific scenario where the encrypted data constructed by a smart meter(SM)exceeds the size of one Paillier ciphertext,the malicious fog node(FN)may use the received ciphertext to obtain the reading of the SM.Secondly,to avoid the possibility of privacy disclosure under certain circumstances,additional hash functions are added to the individual encryption process.In addition,fault tolerance is very important to aggregation schemes in practical scenarios.In most of the current schemes,once some SMs failed,then they will not work.As far as we know,there is no multi-subset aggregation scheme both supports flexible subset data aggregation and fault tolerance.Finally,we construct the first secure flexible subset data aggregation(SFSDA)scheme with fault tolerance by combining the fault tolerance method with the flexible multi-subset aggregation,where FN enables the control server(CS)to finally decrypt the aggregated ciphertext by recovering equivalent ciphertexts when some SMs fail to submit their ciphertexts.Experiments show that our SFSDA scheme keeps the efficiency in implementing a flexible multi-subset aggregation function,and only has a small delay in implementing fault-tolerant data aggregation.
文摘Based on the system of electric power supply for flexible manufacturing systems (FMS), a study has been carried out on the intelligent safety examination, monitoring and maintenance of its running environment. On the basis of the specific feature of the power supply network of an FMS, real time monitoring system of the power supply network and the fault diagnostic expert system for the power equipment have been designed. This system can diagnose not only definite fault phenomena, but also fuzzy, uncertain fault phenomena as well. Fault diagnostic knowledge base for the power equipment has been founded hierarchy architecture model and the method of fault tree analysis. Feasibility of this system has been proved by computer simulation.
基金This work was supported by the National Key R&D Program of China(No.2017YFB0903100)Science and Technology Projects of State Grid Corporation of China(No.521104170043).
文摘Voltage sags in power system may lead to serious problems such as the off-grid of distributed generation and electrical equipment failures.As a novel type of power electronic equipment,a flexible multi-state switch(FMSS)is capable to support the voltage during the grid faults.In this paper,a voltage control strategy to support the voltage in a distribution network is proposed by introducing three-port FMSS.The positive-negative-sequence compensation(PNSC)scheme is adopted to control the active and reactive current.This control scheme eliminates active power oscillations at the port of voltage sags and reduces coupling oscillations of other ports.Based on the characteristics of the voltage support under PNSC scheme,two voltage support strategies are proposed.A proportional-integral controller is introduced to provide the reactive power references,which eliminates the errors when estimating the grid voltage and impedance.A current limiting scheme is adopted to keep the port current in a safe range by adjusting the active and reactive power references.The voltage support strategies in two different voltage sags are simulated,and results show the feasibility and effectiveness of the proposed control strategies.
文摘With continuously increasing of photovoltaic (PV) plant’s penetration, it has become a critical issue to improve the fault ride-through capability of PV plant. This paper refers to the German grid code, and the PV system is controlled to keep grid connected, as well as inject reactive current to grid when fault occurs. The mathematical model of PV system is established and the fault characteristic is studied with respect to the control strategy. By analyzing the effect of reactive power supplied by the PV system to the point of common coupling (PCC) voltage, this paper proposes an adaptive voltage support control strategy to enhance the fault ride-through capability of PV system. The control strategy fully utilizes the PV system’s capability of voltage support and takes the safety of equipment into account as well. At last, the proposed control strategy is verified by simulation.
文摘In order to ensure power system stability, modern wind turbines are required to be able to endure deep voltage dips. The specifications that determine the voltage dip versus time are called fault r/de-through (FRT) requirements. The purpose of this paper is not only to examine the FRT behavior of a full-power converter wind turbine but also to combine the power system viewpoint to the studies. It is not enough for the turbine to be FRT capable; the loss of mains (LOM) protection of the turbine must also be set to allow the FRT. Enabling FRT, however, means that the LOM protection settings must be loosen, which may sometimes pose a safety hazard. This article introduces unique real-time simulation environment and proposes an FRT method for a wind turbine that also takes the operation of LOM protection relay into account. Simulations are carried out using the simulation environment and results show that wind turbine is able to ride-through a symmetrical power system fault.
文摘The installation of wind energy has increased rapidly around the world. The grid codes about the wind energy require wind turbine (WT) has the ability of fault (or low voltage) ride-through (FRT). To study the FRT operation of the wind farms, three methods were discussed. First, the rotor short current of doubly-fed induction generator (DFIG) was limited by introducing a rotor side protection circuit. Second, the voltage of DC bus was limited by a DC energy absorb circuit. Third, STATCOM was used to increase the low level voltages of the wind farm. Simulation under MATLAB was studied and the corresponding results were given and discussed. The methods proposed in this paper can limit the rotor short current and the DC voltage of the DFIG WT to some degree, but the voltage support to the power system during the fault largely depend on the installation place of STATCOM.
基金the Zhejiang Public Welfare Technology Application Research Project(LGF22E080021)Ningbo Natural Science Foundation Project(202003N4169)+2 种基金Natural Science Foundation of China(11202138,52008215)the Natural Science Foundation of Zhejiang Province,China(LQ20E080013)the Major Special Science and Technology Project(2019B10076)of“Ningbo Science and Technology Innovation 2025”.
文摘Shear-type structures are common structural forms in industrial and civil buildings,such as concrete and steel frame structures.Fault diagnosis of shear-type structures is an important topic to ensure the normal use of structures.The main drawback of existing damage assessment methods is that they require accurate structural finite element models for damage assessment.However,for many shear-type structures,it is difficult to obtain accurate FEM.In order to avoid finite elementmodeling,amodel-freemethod for diagnosing shear structure defects is developed in this paper.This method only needs to measure a few low-order vibration modes of the structure.The proposed defect diagnosis method is divided into two stages.In the first stage,the location of defects in the structure is determined based on the difference between the virtual displacements derived from the dynamic flexibility matrices before and after damage.In the second stage,damage severity is evaluated based on an improved frequency sensitivity equation.Themain innovations of this method lie in two aspects.The first innovation is the development of a virtual displacement difference method for determining the location of damage in the shear structure.The second is to improve the existing frequency sensitivity equation to calculate the damage degree without constructing the finite elementmodel.Thismethod has been verified on a numerical example of a 22-story shear frame structure and an experimental example of a three-story steel shear structure.Based on numerical analysis and experimental data validation,it is shown that this method only needs to use the low-order modes of structural vibration to diagnose the defect location and damage degree,and does not require finite element modeling.The proposed method should be a very simple and practical defect diagnosis technique in engineering practice.
文摘Modeling and validation of full power converter wind turbine models with field measurement data are rarely reported in papers. In this paper an aggregated generic dynamic model of the wind farm consisting of full power converter wind turbines is composed and the model validation based on actual field measurements is performed. The paper is based on the measurements obtained from the real short circuit test applied to connection point of observed wind farm. The presented approach for validating the composed model and fault ride-through (FRT) capability for the whole wind park is unique in overall practice and its significance and importance is described and analyzed.
基金supported by the National Key R&D Programs for Young Scientists of China(Grant No.2023YFB2390400)the National Natural Science Foundation of China(Grant Nos.U21A20159,52079133,52379112,and 41902288)+2 种基金Key Research Program of First Survey and Design Institute(Grant No.2022KY56(ZDZX)-02)Key Research Program of the Ministry of Water Resources of China(Grant No.SKS-2022103)Yunnan Major Science and Technology Special Program(Grant No.202102AF080001).
文摘During dislocation,a tunnel crossing the active fault will be damaged to varying degrees due to its permanent stratum displacement.Most previous studies did not consider the influence of the tunnel’s deep burial and the high in-situ stress,so the results were not entirely practical.In this paper,the necessity of solving the anti-dislocation problem of deep-buried tunnels is systemically discussed.Through the model test of tunnels across active faults,the differences in failures between deep-buried tunnels and shallow-buried tunnels were compared,and the dislocation test of deep-buried segmental tunnels was carried out to analyze the external stress change,lining strain,and failure mode of tunnels.The results are as follows.(1)The overall deformation of deep-buried and shallow-buried tunnels is both Sshaped.The failure mode of deep-buried tunnels is primarily characterized by shear and tensile failure,resulting in significant compressive deformation and a larger damaged area.In contrast,shallow-buried tunnels mainly experience shear failure,with the tunnel being sheared apart at the fault crossing,leading to more severe damage.(2)After the segmental structure design of the deep-buried tunnel,the “S”deformation pattern is transformed into a “ladder”pattern,and the strain of the tunnel and the peak stress of the external rock mass are reduced;therefore,damages are significantly mitigated.(3)Through the analysis of the distribution of cracks in the tunnel lining,it is found that the tunnel without a segmental structure design has suffered from penetrating failure and that cracks affect the entire lining.The cracks in a flexible segmental tunnel affect about 66.6% of the entire length of the tunnel,and cracks in a tunnel with a short segmental tunnel only affect about 33.3% of the entire length of the tunnel.Therefore,a deep-buried tunnel with a short segmental tunnel can yield a better anti-dislocation effect.(4)By comparing the shallow-buried segmental tunnel in previous studies,it is concluded that the shallow-buried segmental tunnel will also suffer from deformation outside the fault zone,while the damages to the deep-buried segmental tunnel are concentrated in the fault zone,so the anti-dislocation protection measures of the deep-buried tunnel shall be provided mainly in the fault zone.The results of the above study can provide theoretical reference and technical support for the design and reinforcement measures of the tunnel crossing active fault under high in-situ stress conditions.
基金This work was supported by the National Natural Science Foundation of China(Nos.62203002 and 62203148)Natural Science Foundation of Anhui Province,China(Nos.2208085QF204 and 2208085QF203)+1 种基金the Open Project Program of Fujian Provincial Key Laboratory of Intelligent Identification and Control of Complex Dynamic System,China(No.2022A0001)the Fundamental Research Funds for the Central Universities,China(No.JZ2022HGTA0346).
文摘This paper studies a robust fault compensation and vibration suppression problem of flexible hypersonic vehicles.The controlled plant is represented by a cascade system composed of a nonlinear Ordinary Differential Equation(ODE)and an Euler-Bernoulli Beam Equation(EBBE),in which the vibration dynamics is coupled with the rigid dynamics and suffers from distributed faults.A state differential transformation is introduced to transfer distributed faults to an EBBE boundary and a longitudinal dynamics is refined by utilizing T-S fuzzy IF-THEN rules.A novel T-S fuzzy based fault-tolerant control algorithm is developed and related stability conditions are established.The robust exponential stability and well-posedness are proved by using the modified l_(0)-semigroup based Lyapunov direct approach.A simulation study on the longitudinal dynamics of flexible hypersonic vehicles effectively verifies the validity of the developed theoretical results.
基金The National Natural Science Foundation of China(No.41572276)the National Key Research and Development Program of China(No.2017YFC0805400).
文摘For the tunnel crossing active fault,the damage induced by fault movement is always serious.To solve such a problem,a detailed anti-faulting tunnel design process for Urumqi subway line 2 was introduced,and seven three-dimensional elastic-plastic finite element models were established.The anti-faulting design process included three steps.First,the damage of tunnel lining from different locations of fault rupture surfaces was analyzed.Then,the analysis of the effect on tunnel buried depth was given.Finally,the effect of the disaster mitigation method on the flexible joint was verified and the location of the flexible joint was discussed.The results show that when the properties of surrounding rock at the tunnel bottom grows soft,the tunnel deformation curve is smoother and tunnel damage induced by fault movement is less serious.The vertical displacement change ratio of secondary linings along the tunnel axis may be the main factor to cause shear damage to the tunnel.The interface between the hanging wall and fracture zone is defined as the most adverse fault rupture surface.The tunnel damage was reduced with the decrease in the tunnel buried depth as more energy was dissipated by overburden soil and the differential uplift zone of soil became more diffuse.The method of the flexible joint can reduce the tunnel damage significantly and the disaster mitigation effect of different locations on the flexible joint is different.The tunnel damage is reduced by the greatest degree when the flexible joint is located on the fault rupture surface.
基金supported by the National Natural Science Foundation of China (61034005)the Natural Science Foundation of Jiangsu Province (BK2010072)
文摘This paper presents a scheme of fault diagnosis for flexible satellites during orbit maneuver. The main contribution of the paper is related to the design of the nonlinear input observer which can avoid false alarm arising from the disturbance from orbit control force. The effects of orbit control force on the fault diagnosis system for satellite attitude control systems, including the disturbing torque caused by the misalignments and the model uncertainty caused by the fuel consumed, are discussed, where standard Lu- enberger observer cannot work well. Then the nonlinear unknown input observer is proposed to decouple faults from disturbance, Besides, a linear matrix inequality approach is adopted to reduce the effect of nonlinear part and model uncertainties on the observer. The numerical and semi-physical simulation demonstrates the effectiveness of the proposed observer for the fault diagnosis system of the satellite during orbit maneuver.
文摘It is assumed that a pipeline is laid through a vertical fault fracture zone, and is excited by seismic ground motion modelled as stationary stochastic process. For horizontal incidence of waves, the cross-PSD (Power Spectral Density) function is developed using wave propagation theory, while for vertical incidence of waves the cross-PSD function is composed by auto-PSD model, coherence model and site response model. As the seismic input, the eross-PSD function is used to calculate the the axial and lateral seismic responses of underground pipeline through the fracture zone. The results show that the incident directions of seismic waves, width and soil property of the fracture zone have great influence on underground pipeline. It is suggested that the flexible joints with appropriate stiffness should be added into the pipeline near the interfaces between the fracture zone and the surrounded media.
文摘Determining the fault location using conventional impedance based distance relay in the presence of FACTS controllers is a challenging task in a transmission line. A new distance protection method is developed to locate the fault in a transmission line compensated with STATCOM with simple calculations. The proposed protection method considers the STATCOM injected/absorbed current to correct the fault loop apparent impedance and accordingly calculates the actual distance to the fault location. The comprehensive equations needed for apparent impedance calculation are also outlined and the performance is evaluated and tested with a typical 400 KV transmission system for different fault types and locations using MATLAB/SIMULINK software. The evaluation results indicate that the new protection method effectively estimates the exact fault location by mitigating the impact of STATCOM on distance relay performance with error less than 0.3%.