Based on the fact that the house dust usually falls on the ground,the floor level slit exhaust ventilation system including inlet located at the ceiling and outlet of slit exhaust installed at corner between wall and ...Based on the fact that the house dust usually falls on the ground,the floor level slit exhaust ventilation system including inlet located at the ceiling and outlet of slit exhaust installed at corner between wall and floor was considered.Experiments and simulations were performed to investigate the flow and diffusion fields that are affected by this floor level slit exhaust ventilation system.The characteristics of airflow with experiments and computation fluid dynamics(CFD) are generally similar except airflow at the location of impinging flow and the location right below the inlet.Riboflavin particles were used as the house dust.For the spatial distribution of riboflavin particles in the ventilation system before operation,due to the influence of gravity,different sizes of particles show smooth decay curve.After floor level slit exhaust ventilation system is operated,the decay rate of the particles becomes faster than that after the ventilation system is powered on,and the particles with diameter of 0.5-3.0 μm in the experimental data and calculated values show good agreement.展开更多
Background: Quantitative biomechanical characterization of pelvic supportive structures and functions in vivo is thought to provide insight into pathophysiology of pelvic organ prolapse (POP). An innovative approach—...Background: Quantitative biomechanical characterization of pelvic supportive structures and functions in vivo is thought to provide insight into pathophysiology of pelvic organ prolapse (POP). An innovative approach—vaginal tactile imaging—allows biomechanical mapping of the female pelvic floor to quantify tissue elasticity, pelvic support, and pelvic muscle functions. The Vaginal Tactile Imager (VTI) records high definition pressure patterns from vaginal walls under an applied tissue deformation and during pelvic floor muscle contractions. Objective: To explore an extended set of 52 biomechanical parameters for differentiation and characterization of POP relative to normal pelvic floor conditions. Methods: 96 subjects with normal and POP conditions were included in the data analysis from multi-site observational, case-controlled studies;42 subjects had normal pelvic floor conditions and 54 subjects had POP. The VTI, model 2S, was used with an analytical software package to calculate automatically 52 biomechanical parameters for 8 VTI test procedures (probe insertion, elevation, rotation, Valsalva maneuver, voluntary muscle contractions in 2 planes, relaxation, and reflex contraction). The groups were equalized for subject age and parity. Results: The ranges, mean values, and standard deviations for all 52 VTI parameters were established. 33 of 52 parameters were identified as statistically sensitive (p 0.05;t-test) to the POP development. Among these 33 parameters, 11 parameters show changes (decrease) in tissue elasticity, 8 parameters show deteriorations in pelvic support and 14 parameters show weakness in muscle functions for POP versus normal conditions. Conclusions: The biomechanical mapping of the female pelvic floor with the VTI provides a unique set of parameters characterizing POP versus normal conditions. These objectively measurable biomechanical transformations of pelvic tissues, support structures, and functions under POP may be used in future research and practical applications.展开更多
Two practical crawlspace heating systems introduced in detached houses have been chosen as a field study. One is the crawlspace warm air heating system and the other is the crawlspace hot water circulation system. Bas...Two practical crawlspace heating systems introduced in detached houses have been chosen as a field study. One is the crawlspace warm air heating system and the other is the crawlspace hot water circulation system. Based on the field study result, by using the simulation software, THERB, the effectiveness of the crawlspace warm air heating system has been examined. The effect of the factors, such as the wind amount circulating between crawlspace and indoor space, foundation insulation condition, and heat amount into the crawlspace, on the indoor thermal environment has been analyzed. Based on these analyses, the measured crawlspace heating system can make the average temperature of the living room above 20 °C. These two houses have excellent thermal environment. According to the simulating result, heat amount input into crawlspace, which can make comfortable indoor thermal environment, for every month in heating period has been roughly concluded, and they are 600 W in December and March and 800 W in February and January, respectively.展开更多
基金Project supported by Ministry of Land, Infrastructure, Transport and Tourism of Japan Project(DUT10RC(3)103) supported by the Fundamental Research Funds for the Central Universities in China+2 种基金 Project(20111027) supported by the Liaoning Provincial Scientific Research Foundation, China Key Project (2012BAJ02B05) supported by the Twelfth Five-Year National Technology Program of China Project supported by Dalian Municipal Construction Technology Program, China
文摘Based on the fact that the house dust usually falls on the ground,the floor level slit exhaust ventilation system including inlet located at the ceiling and outlet of slit exhaust installed at corner between wall and floor was considered.Experiments and simulations were performed to investigate the flow and diffusion fields that are affected by this floor level slit exhaust ventilation system.The characteristics of airflow with experiments and computation fluid dynamics(CFD) are generally similar except airflow at the location of impinging flow and the location right below the inlet.Riboflavin particles were used as the house dust.For the spatial distribution of riboflavin particles in the ventilation system before operation,due to the influence of gravity,different sizes of particles show smooth decay curve.After floor level slit exhaust ventilation system is operated,the decay rate of the particles becomes faster than that after the ventilation system is powered on,and the particles with diameter of 0.5-3.0 μm in the experimental data and calculated values show good agreement.
文摘Background: Quantitative biomechanical characterization of pelvic supportive structures and functions in vivo is thought to provide insight into pathophysiology of pelvic organ prolapse (POP). An innovative approach—vaginal tactile imaging—allows biomechanical mapping of the female pelvic floor to quantify tissue elasticity, pelvic support, and pelvic muscle functions. The Vaginal Tactile Imager (VTI) records high definition pressure patterns from vaginal walls under an applied tissue deformation and during pelvic floor muscle contractions. Objective: To explore an extended set of 52 biomechanical parameters for differentiation and characterization of POP relative to normal pelvic floor conditions. Methods: 96 subjects with normal and POP conditions were included in the data analysis from multi-site observational, case-controlled studies;42 subjects had normal pelvic floor conditions and 54 subjects had POP. The VTI, model 2S, was used with an analytical software package to calculate automatically 52 biomechanical parameters for 8 VTI test procedures (probe insertion, elevation, rotation, Valsalva maneuver, voluntary muscle contractions in 2 planes, relaxation, and reflex contraction). The groups were equalized for subject age and parity. Results: The ranges, mean values, and standard deviations for all 52 VTI parameters were established. 33 of 52 parameters were identified as statistically sensitive (p 0.05;t-test) to the POP development. Among these 33 parameters, 11 parameters show changes (decrease) in tissue elasticity, 8 parameters show deteriorations in pelvic support and 14 parameters show weakness in muscle functions for POP versus normal conditions. Conclusions: The biomechanical mapping of the female pelvic floor with the VTI provides a unique set of parameters characterizing POP versus normal conditions. These objectively measurable biomechanical transformations of pelvic tissues, support structures, and functions under POP may be used in future research and practical applications.
基金Project(10YZ156) supported by Innovation Program of Shanghai Municipal Education Commission, China Project(sdl09009) supported by Training Program for Outstanding Youth Teacher of Shanghai Municipal Education Commission, China Project(Z2010-103) supported by Shanghai Education Development Foundation, China
文摘Two practical crawlspace heating systems introduced in detached houses have been chosen as a field study. One is the crawlspace warm air heating system and the other is the crawlspace hot water circulation system. Based on the field study result, by using the simulation software, THERB, the effectiveness of the crawlspace warm air heating system has been examined. The effect of the factors, such as the wind amount circulating between crawlspace and indoor space, foundation insulation condition, and heat amount into the crawlspace, on the indoor thermal environment has been analyzed. Based on these analyses, the measured crawlspace heating system can make the average temperature of the living room above 20 °C. These two houses have excellent thermal environment. According to the simulating result, heat amount input into crawlspace, which can make comfortable indoor thermal environment, for every month in heating period has been roughly concluded, and they are 600 W in December and March and 800 W in February and January, respectively.