期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
Development of a Recombinase-aided Amplification Combined With Lateral Flow Dipstick Assay for the Rapid Detection of the African Swine Fever Virus 被引量:2
1
作者 LI Jiang Shuai HAO Yan Zhe +6 位作者 HOU Mei Ling ZHANG Xuan ZHANG Xiao Guang CAO Yu Xi LI Jin Ming MA Jing ZHOU Zhi Xiang 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2022年第2期133-140,共8页
Objective To establish a sensitive,simple and rapid detection method for African swine fever virus(ASFV)B646L gene.Methods A recombinase-aided amplification-lateral flow dipstick(RAA-LFD)assay was developed in this st... Objective To establish a sensitive,simple and rapid detection method for African swine fever virus(ASFV)B646L gene.Methods A recombinase-aided amplification-lateral flow dipstick(RAA-LFD)assay was developed in this study.Recombinase-aided amplification(RAA)is used to amplify template DNA,and lateral flow dipstick(LFD)is used to interpret the results after the amplification is completed.The lower limits of detection and specificity of the RAA assay were verified using recombinant plasmid and pathogenic nucleic acid.In addition,30 clinical samples were tested to evaluate the performance of the RAA assay.Results The RAA-LFD assay was completed within 15 min at 37°C,including 10 min for nucleic acid amplification and 5 minutes for LFD reading results.The detection limit of this assay was found to be 200 copies per reaction.And there was no cross-reactivity with other swine viruses.Conclusion A highly sensitive,specific,and simple RAA-LFD method was developed for the rapid detection of the ASFV. 展开更多
关键词 African swine fever virus Recombinase aided amplification Lateral flow detection
下载PDF
Lateral Flow Immunoassay for Quantitative Detection of Ractopamine in Swine Urine 被引量:3
2
作者 REN Mei Ling CHEN Xue Lan +4 位作者 LI Chao Hui XU Bo LIU Wen Juan XU Heng Yi XIONG Yong Hua 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2014年第2期134-137,共4页
A strip reader based lateral flow immunoassay (LFIA) was established for the rapid and quantitative detection of ractopamine (RAC) in swine urine. The ratio of the optical densities (ODs) of the test line (AT)... A strip reader based lateral flow immunoassay (LFIA) was established for the rapid and quantitative detection of ractopamine (RAC) in swine urine. The ratio of the optical densities (ODs) of the test line (AT) to that of the control line (Ac) was used to effectively minimize interference among strips and sample variations. The linear range for the quantitative detection of RAC was 0.2 ng/mL to 3.5 ng/mL with a median inhibitory concentration (IC50) of 0.59+0.06 ng/mL. The limit of detection (LOD) of the LFIA was 0.13 ng/mL. The intra-assay recovery rates were 92.97%, 97.25%, and 107.41%, whereas the inter-assay rates were 80.07%, 108.17%, and 93.7%, respectively. 展开更多
关键词 RAC Lateral Flow Immunoassay for Quantitative detection of Ractopamine in Swine Urine FIGURE AT
下载PDF
SELECTIVE SULFUR DIOXIDE DETERMINATION BY GAS DIFFUSION FLOW INJECTION ANALYSIS WITH CHEMILUMINESCENT DETECTION
3
作者 Yong He BAO Qi Jun SONG Department of Chemistry,XingJiang University,Urumchi,830046 《Chinese Chemical Letters》 SCIE CAS CSCD 1991年第4期313-314,共2页
Sulfur dioxide has been found to decrease the chemiluminescence of luminol-iodine system.A new determination method for sulfur dioxide in atmosphere is developed by applying this reaction to a flow injection gas diffu... Sulfur dioxide has been found to decrease the chemiluminescence of luminol-iodine system.A new determination method for sulfur dioxide in atmosphere is developed by applying this reaction to a flow injection gas diffusion separation system.This permits the determination of sulfur dioxide selectively and rapidly. 展开更多
关键词 FLOW SELECTIVE SULFUR DIOXIDE DETERMINATION BY GAS DIFFUSION FLOW INJECTION ANALYSIS WITH CHEMILUMINESCENT detection GAS
下载PDF
The Clinical Value of Detecting the Level of Exfoliated Cells in Pleural Effusion by Flow Cytometry in the Differential Diagnosis of Non-
4
作者 Yang Yu Yiyang Li +2 位作者 Chengbi Tong Xiaomeng Zheng Chao Yang 《Journal of Clinical and Nursing Research》 2023年第3期165-169,共5页
Objective:To explore the value of flow cytometry(FCM)in detecting the level of exfoliated cells in pleural effusion in the differential diagnosis of non-small cell lung cancer and benign lung diseases.Methods:Clinical... Objective:To explore the value of flow cytometry(FCM)in detecting the level of exfoliated cells in pleural effusion in the differential diagnosis of non-small cell lung cancer and benign lung diseases.Methods:Clinical data of patients with non-small cell lung cancer who were hospitalized in Hebei hospital from June 2019 to March 2022 were collected.A total of 98 patients were included,and 63 patients with alveolar lung disease were screened during the same period,and the two groups of patients were analyzed.Results:Compared with alveolar lung disease group,FCM detection and analysis showed that the level of exfoliated cells in the pleural effusion of non-small cell lung cancer(NSCLC)patients was 99(3-969)/100,000,and patients with alveolar lung disease was 4(0~19)/100,000.Additionally,compared with the alveolar lung disease group,the level of exfoliated cells in the pleural effusion of patients with non-small cell lung cancer(NSCLC)was significantly increased(P<0.001).The diagnostic efficacy of FCM for detecting pleural fluid exfoliated cells in non-small cell lung cancer was assessed using ROC curves and using 95%CI(-11.1,-13.2)with a sensitivity of 0.75 and specificity of 0.94,and the diagnostic efficacy of FCM for detecting pleural fluid exfoliated cells in alveolar lung disease was assessed using 95%CI(-11.1,-13.2)with a sensitivity of 0.71 and specificity of 0.87.Conclusion:Flow cytometry has a wider range of clinical applications,simple operation,low cost,and high sensitivity,which makes it of great significance in disease diagnosis. 展开更多
关键词 Flow cytometry detection Non-small cell lung cancer Benign lung disease
下载PDF
AN APPROACH OF DEFENDING AGAINST DDOS ATTACK 被引量:1
5
作者 Wu Zhijun Duan Haixin Li Xing 《Journal of Electronics(China)》 2006年第1期148-153,共6页
An approach of defending against Distributed Denial of Service (DDoS) attack based on flow model and flow detection is presented. The proposed approach can protect targets from DDoS attacking, and allow targets to pro... An approach of defending against Distributed Denial of Service (DDoS) attack based on flow model and flow detection is presented. The proposed approach can protect targets from DDoS attacking, and allow targets to provide good service to legitimate traffic under DDoS attacking, with fast reaction. This approach adopts the technique of dynamic comb filter, yields a low level of false positives of less than 1.5%, drops similar percentage of good traffic, about 1%, and passes neglectable percentage of attack bandwidth to the victim, less than 1.5%. The prototype of commercial product, D-fighter, is developed by implementing this proposed approach on Intel network processor platform IXP1200. 展开更多
关键词 Distributed Denial of Service (DDoS) DEFENDING Flow model Flow detection IXP1200 Dfighter
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部