期刊文献+
共找到17篇文章
< 1 >
每页显示 20 50 100
INVESTIGATION OF VORTEX SHEDDING INDUCED HYDRODYNAMIC VIBRATION IN VORTEX STREET FLOWMETER 被引量:2
1
作者 Fu Xin,Xu Bing,Yang Huayong (State Key Laboratory of Fluid Power Transmission and Control,Zhejiang University) 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2001年第4期310-313,共4页
Vortex street flowmeter has been used in steady flow measurement for about three decades The benefits of this type of flowmeter include high accuracy,good linearty,wide measuring range,and excellent reliability Ho... Vortex street flowmeter has been used in steady flow measurement for about three decades The benefits of this type of flowmeter include high accuracy,good linearty,wide measuring range,and excellent reliability However,in unsteady flow measurement,the pressure disturbance as well as the noise from the system or surrounding can reduce the signal to noise ratio of the flowmeter seriously Aimed to use vortex street flowmeters in unsteady flow measurement,the characteristics of the vortex shedding induced hydrodynamic vibration around the prism bluff body in a vortex street flowmeter are investigated numerically and by expriments The results show that the hydrodynamic vibrations with 180° phase shift occur at the axisymmetric points of the channel around the bluff body The most intense vibration occurs at the points on the lateral faces close to the base of the prism The results provide therefore a useful reference for developing an anti interference vortex flowmeter using the different ial sensing technique. 展开更多
关键词 Vortex street flowmeter Vortex shedding induced hydrodynamic vibration Unsteady flow measurement Anti-interference performance
下载PDF
Numerical Solution of the Weight Function for Electromagnetic Flowmeter 被引量:3
2
作者 FAN Shi-wei CAO Zhang +1 位作者 XU Li-jun WANG Gang 《Computer Aided Drafting,Design and Manufacturing》 2010年第2期36-41,共6页
A numerical solution of the weight function for a two-electrode electromagnetic flowmeter was proposed. The solution was obtained by using the finite element method based on the basic equation of a traditional two-ele... A numerical solution of the weight function for a two-electrode electromagnetic flowmeter was proposed. The solution was obtained by using the finite element method based on the basic equation of a traditional two-electrode electromagnetic flowmeter. The two-dimensional distribution of the weight function of the electromagnetic flowmeter obtained was verified by the analytical solution. Three-dimensional distribution of the weight function was also presented in the paper. It can be employed to analyze the sensitivity and linearity of the electromagnetic flowmeter with non-uniform magnetic field, and even to assist the design of the excitation coil pair. 展开更多
关键词 electromagnetic flowmeter weight function finite element method numerical solution virtual current
下载PDF
Research and Development on β Ray Ionization Gas Flowmeter
3
作者 安伟 魏任之 +2 位作者 张启明 朱煜 叶平 《International Journal of Mining Science and Technology》 SCIE EI 1999年第2期179-182,共4页
A new method of measuring gas flow in heavy or medium pipe based on the ionization effect of gas irradi ated with rays is presented. The mesurement principle of the flowmeter has been theoretically analyzed,the struct... A new method of measuring gas flow in heavy or medium pipe based on the ionization effect of gas irradi ated with rays is presented. The mesurement principle of the flowmeter has been theoretically analyzed,the structure form and the base of relevant parameter’s choice of the flowmeter have been given, and theintellectual instrument is developed. The results of experiment show that the per formance of the flowmeter is stable, the precision can reach 1 to 1. 5 percent, and it has fairly capability to resist disturbance and pollution. 展开更多
关键词 flowmeter IONIZATION GAS ISOTOPE instrument
下载PDF
Development of DSP-Based Dynamic Signal Processing Module for Turbine Flowmeter
4
作者 Liu Yuan Zhang Tianhong 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI CSCD 2016年第5期546-551,共6页
Traditional signal processing methods for turbine flowmeter are unable to solve the contradiction between the real-time performance and the accuracy during the aeroengine bench test or hardware in the loop(HIL)simulat... Traditional signal processing methods for turbine flowmeter are unable to solve the contradiction between the real-time performance and the accuracy during the aeroengine bench test or hardware in the loop(HIL)simulation of aeroengine control system.A dynamic flow measurement method based on cycle number of the flowmeter is proposed.And a DSP-based multi-functional dynamic signal processing module for turbine flowmeter is built to validate the method.The developed system can provide three types of output modes including PWM,frequency and D/A.At the same time,the results can be displayed instantly with the module of serial communication interface to obtain dynamic flow signal with good precision.Experimental results show that the stability of flow measurement is greatly improved with precision guaranteed and the real-time response reaches the maximum limit of turbine flowmeter. 展开更多
关键词 turbine flowmeter DSP cycle-number filter dynamic flow measurement
下载PDF
Research on double differential pressure dynamic flowmeter
5
作者 刘涛 Zuo Zhibing Yin Zhigang 《High Technology Letters》 EI CAS 2019年第4期378-385,共8页
When testing an electrohydraulic proportional valve,it is necessary to test the high frequency dynamic flow with bias.Because of the limitation of the piston stroke,a no-load hydraulic cylinder is only suitable for a ... When testing an electrohydraulic proportional valve,it is necessary to test the high frequency dynamic flow with bias.Because of the limitation of the piston stroke,a no-load hydraulic cylinder is only suitable for a reciprocating symmetrical dynamic flow test.Since the traditional differential pressure flowmeter is affected by viscosity and inertia of the fluid,it is only suitable for measuring steady flow.Therefore,a new type of double pressure differential dynamic flowmeter is designed to improve the traditional differential pressure flowmeter.The influence of fluid viscosity and inertia in the flow process are negated by subtracting the differential pressure in section expansion from the differential pressure in section contraction.The double differential pressure flowmeter is modeled and a flow meter prototype is designed.Then,the flow coefficients are identified and corrected by a practical test.Finally,the dynamic performance and steady-state precision of the flowmeter are verified by comparing with the test results of the no-load hydraulic cylinder.The double differential pressure dynamic flowmeter is proven to measure dynamic flow accurately,especially at higher dynamic frequencies. 展开更多
关键词 dynamic flowmeter DOUBLE differential pressure CONTRAST experiment COEFFICIENT CORRECTION
下载PDF
DESIGN,FABRICATION,TESTING AND MECHANICAL ANALYSIS OF BULK-MICROMACHINED FLOWMETERS
6
作者 王小保 钱劲 张大成 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 2004年第2期152-158,共7页
Micromachined piezoresistive flowmeters with four different types of sensing struc- tures have been designed,fabricated and tested.Piezoresistors were defined at the end of the sensors through p-diffusion,and their va... Micromachined piezoresistive flowmeters with four different types of sensing struc- tures have been designed,fabricated and tested.Piezoresistors were defined at the end of the sensors through p-diffusion,and their values were about 3.5kΩ.Wheatstone bridge was configured with the piezoresistors in order to measure the output response.The output voltage increases with increasing flow rate of air,obeying determined relationships.The testing results show that the sensors that are designed for measuring 10L/M in full operational range have desired sensitivities.The sensor chip is manufactured with bulk-micromachining technologies,requiring a set of seven masks. 展开更多
关键词 micromachined flowmeters bulk-micromachining PIEZORESISTIVITY Wheatstone bridge
下载PDF
Accuracy of Medical Oxygen Flowmeters: A Multicentric Field Study
7
作者 Frédéric Duprez Maria Barile +4 位作者 Thierry Bonus Grégory Cuvelier Sandra Ollieuz Shahram Mashayekhi Alexandre Legrand 《Health》 2014年第15期1978-1983,共6页
The accuracy of 476 oxygen flowmeters was investigated using a thermal mass flowmeter in eight hospitals in France and Belgium. Different oxygen flow rates (2 to 15 l/min) were evaluated at the patient’s bed. When th... The accuracy of 476 oxygen flowmeters was investigated using a thermal mass flowmeter in eight hospitals in France and Belgium. Different oxygen flow rates (2 to 15 l/min) were evaluated at the patient’s bed. When the sample was considered as a whole, the accuracy of delivered flow was acceptable but precision was poor. The variability of the delivered flow between devices was greater when a low flow rate was required. Compensated-pressure oxygen flowmeters for these low rates were more accurate than their non-compensated counterparts. This study emphasizes the need to individually adapt the oxygen flow rate each time a patient has to move from one flowmeter to another. 展开更多
关键词 MEDICAL Device ACCURACY OXYGEN Therapy flowmeter
下载PDF
Design of the target type flowmeter based on fiber Bragg grating and experiment 被引量:2
8
作者 乔学光 张倩 +1 位作者 傅海威 禹大宽 《Chinese Optics Letters》 SCIE EI CAS CSCD 2008年第11期815-817,共3页
The target type flowmeter based on fiber Bragg gratings (FBGs) is experimentally studied. The relationship between the central wavelength shift of FBG and the flux is derived and the analytic expression is also give... The target type flowmeter based on fiber Bragg gratings (FBGs) is experimentally studied. The relationship between the central wavelength shift of FBG and the flux is derived and the analytic expression is also given. Simulation and preliminary experiments have been carried out, and experimental validation of the water further proves the feasibility of the sensor. The experimental results verify the proposed sensor which can measure flux range from 200 to 1200 cm^3/s. And on this basis, the improvement program is raised. 展开更多
关键词 EXPERIMENTS Fiber optic components Fiber optic sensors Flow measurement flowmeterS SENSORS
原文传递
Flow-induced vibration characteristics of the U-type Coriolis mass flowmeter with liquid hydrogen 被引量:1
9
作者 Xiang-xiang PEI Xiang LI +2 位作者 Hao-hao XU Xuan-hong YE Xiao-bin ZHANG 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2022年第6期495-504,共10页
Compared with liquid nitrogen(LN_(2))and water,the density of liquid hydrogen(LH_(2))is more than one order of magnitude smaller,which leads to significantly different flow-induced vibration characteristics in the cor... Compared with liquid nitrogen(LN_(2))and water,the density of liquid hydrogen(LH_(2))is more than one order of magnitude smaller,which leads to significantly different flow-induced vibration characteristics in the coriolis mass flowmeter(CMF).Based on the Euler beam theory,the complex set of equations of fluid-solid interactions for the U-type pipe Coriolis flowmeter with LH_(2)is solved.The calculation results are firstly validated by comparing the dimensionless frequency,displacement,and twist mode shape with the theoretical and experimental results in the other publications with water and kerosene as the working fluids.Then,the results of dimensionless frequency,phase difference,and time lag for LH_(2)are compared with those for LN_(2)and water,and the effects of the dimensionless flow velocity,sensor position,and the radius of the curved pipe are analyzed in detail for LH_(2).Results show that the time lag of LH_(2)is an order of magnitude smaller than that for LN_(2)or water.The excitation frequency for LH_(2)is much larger than that for LN_(2).Effects of geometric parameters on the time lag are also analyzed for the three fluids and the results contribute to the design optimization of a CMF for LH_(2). 展开更多
关键词 Coriolis mass flowmeter(CMF) Liquid hydrogen(LH_(2)) Cryogenic fluid Flow-induced vibration
原文传递
Improvement of signal processing in Coriolis mass flowmeters for gas-liquid two-phase flow
10
作者 Chunhui LI Lijun SUN +3 位作者 Jiarong LIU Yang ZHANG Haiyang LI Huaxiang WANG 《Frontiers of Information Technology & Electronic Engineering》 SCIE EI CSCD 2021年第2期272-286,共15页
As an increasingly popular flow metering technology,Coriolis mass flowmeter exhibits high measurement accuracy under single-phase flow condition and is widely used in the industry.However,under complex flow conditions... As an increasingly popular flow metering technology,Coriolis mass flowmeter exhibits high measurement accuracy under single-phase flow condition and is widely used in the industry.However,under complex flow conditions,such as two-phase flow,the measurement accuracy is greatly decreased due to various factors including improper signal processing methods.In this study,three digital signal processing methods—the quadrature demodulation(QD)method,Hilbert method,and sliding discrete time Fourier transform method—are analyzed for their applications in processing sensor signals and providing measurement results under gas-liquid two-phase flow condition.Based on the analysis,specific improvements are applied to each method to deal with the signals under two-phase flow condition.For simulation,sensor signals under single-and two-phase flow conditions are established using a random walk model.The phase difference tracking performances of these three methods are evaluated in the simulation.Based on the digital signal processor,a converter program is implemented on its evaluation board.The converter program is tested under single-and two-phase flow conditions.The improved signal processing methods are evaluated in terms of the measurement accuracy and complexity.The QD algorithm has the best performance under the single-phase flow condition.Under the two-phase flow condition,the QD algorithm performs a little better in terms of the indication error and repeatability than the improved Hilbert algorithm at 160,250,and 420 kg/h flow points,whereas the Hilbert algorithm outperforms the QD algorithm at the 600 kg/h flow point. 展开更多
关键词 Coriolis mass flowmeter Digital signal processing method Two-phase flow condition Quadrature demodulation Sliding discrete time Fourier transform(SDTFT) Hilbert transform
原文传递
矿井主排水系统的集中控制改造设计
11
作者 阮伟 《科技资讯》 2011年第19期55-55,共1页
为了响应单位精简机构,大幅度减员提效,实现矿井综合自动化办公,减少人员职责不清、缺乏效率的状况,现将我单位井下主排水泵房进行自动化改造。实现井下中央泵房的自动控制后,可以达到无人值守,提高矿井的自动化水平。
关键词 超声流量计(Ultrasonic flowmeter) 水位传感器(Water Level Sensor) 耐磨离心水泵(Wear-resistant CENTRIFUGAL pump)
下载PDF
On Switching of a Flip-Flop Jet Nozzle with Double Ports by Single-Port Control 被引量:1
12
作者 Tatsuya Inoue Fumiaki Nagahata Katsuya Hirata 《Journal of Flow Control, Measurement & Visualization》 2016年第4期143-161,共20页
This research deals with the oscillation mechanism of a flip-flop jet nozzle with a connecting tube, based on the measurements of pressures and velocities in the connecting tube and inside the nozzle. The measurements... This research deals with the oscillation mechanism of a flip-flop jet nozzle with a connecting tube, based on the measurements of pressures and velocities in the connecting tube and inside the nozzle. The measurements are carried out varying: 1) the inside diameter d of the connecting tube;2) the length L of the connecting tube and 3) the jet velocity VPN from a primary-nozzle exit. We assume that the jet switches when a time integral reaches a certain value. At first, as the time integral, we introduce the accumulated flow work of pressure, namely, the time integral of mass flux through a connecting tube into the jet-reattaching wall from the opposite jet-un-reattaching wall. Under the assumption, the trace of pressure difference between both the ends of the connecting tube is simply modeled on the basis of measurements, and the flow velocity in the connecting tube is computed as incompressible flow. Second, in order to discuss the physics of the accumulated flow work further, we conduct another experiment in single-port control where the inflow from the control port on the jet-reattaching wall is forcibly controlled and the other control port on the opposite jet-un-reattaching wall is sealed, instead of the experiment in regular jet’s oscillation using the ordinary nozzle with two control ports in connection. As a result, it is found that the accumulated flow work is adequate to determine the dominant jet- oscillation frequency. In the experiment in single-port control, the accumulated flow work of the inflow until the jet’s switching well agrees with that in regular jet’s oscillation using the ordinary nozzle. 展开更多
关键词 Flip-Flop Jet Nozzle flowmeter FLUIDICS Mixing Flow Control
下载PDF
Application of MCU in refrigerant charging system
13
作者 GUAN Yu-dong, WANG Ming-yan, CHEN Xue-quan (Harbin Institute of Technology, Harbin 150001, China) 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2000年第S1期88-90,共3页
The technique of Microprocessor Control applicable to the refrigerant charging system is introduced while the technique of interface between LCD module MCG12864A4-2 and MCU is described, and the work flow and the idea... The technique of Microprocessor Control applicable to the refrigerant charging system is introduced while the technique of interface between LCD module MCG12864A4-2 and MCU is described, and the work flow and the idea of software are presented as well. 展开更多
关键词 MCU REFRIGERANT TURBINE flowmeter LCD MODULE
下载PDF
The Effects of DPPH on Cochlear Microcirculation
14
作者 孔维佳 陈敏 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2003年第2期198-200,共3页
To investigate the effects of the free radical, 1, l-Diphenyl-2-picylhydrazyl, on cochlear blood flow, 20 guinea pigs were divided into 3 groups at random, 6 for control group, 6 for 1 mmol/ L group and 8 for 0. 1 mmo... To investigate the effects of the free radical, 1, l-Diphenyl-2-picylhydrazyl, on cochlear blood flow, 20 guinea pigs were divided into 3 groups at random, 6 for control group, 6 for 1 mmol/ L group and 8 for 0. 1 mmol/L group. 2 μl vehicle or drugs were dropped into round window membrane (RWM). Cochlear microcirculation was monitored by laser Doppler flowmeter (LDF), and mean arterial blood flow (MABP), which was transferred by pressure conductor sensor and preamplifier, was simultaneously recorded on the computer. Our results showed that MABP was stable throughout the experiment. Cochlear blood flow (CBF) increased by 10. 32 % (P<0. 05) in 1 mmol/L group, and decreased by 4. 89 % in 0. 1 mmol/L group (P<0. 05). In control group cochlear microcirculation showed no significant changes. It is concluded that DPPH exerted effects on cochlear microcirculation. 展开更多
关键词 DPPH laser Dopper flowmeter cochlear blood flow
下载PDF
EXPERIMENTAL STUDY OF VELOCITY DISTRIBUTIONS IN THE TRANSITION REGION OF PIPES 被引量:5
15
作者 LIU Yong-hui DU Guang-sheng LIU Li-ping SHAO Zhu-feng ZHAI Cheng-yuan 《Journal of Hydrodynamics》 SCIE EI CSCD 2011年第5期643-648,共6页
The accuracy of an ultrasonic flowmeter meaurement depends on the profile-linear average velocity. But this velocity in the transition region is not available at the present. In this article, the velocity in the trans... The accuracy of an ultrasonic flowmeter meaurement depends on the profile-linear average velocity. But this velocity in the transition region is not available at the present. In this article, the velocity in the transition region in pipes is studied by experimental methods. The Particle Image Velocimetry ( PIV ) is used to measure the flow field in the transition region in pipes, and the measured results from PIV are in good agreement with the Westerwell's experimental data. Based on the experimental data of PIV, the curves of the profile-linear average velocity in the transition region against the Reynolds number in the range from 2 000 to 20 000 are obtained, and it is shown that the coefficient k is constant when the Reynolds number is in the range of 2 000-2 400 and 6 000-20 000, and the coefficient k is increasing when the Reynolds number is in the range of 2 400-6 000. The results of this article can be used to improve the measurement accuracy of the ultrasonic flowmeters and as a theoretical basis for the research on the transition flow. 展开更多
关键词 ultrasonic flowmeter Particle Image Velocimetry (PIV) the profile-linear average velocity transition region PIPE
原文传递
Estimation of vehicle queuing lengths at metering roundabouts
16
作者 Hong Ki An Wen Long Yue Branko Stazic 《Journal of Traffic and Transportation Engineering(English Edition)》 2017年第6期545-554,共10页
Signalized metering roundabouts are equipped with advanced loop detectors and traffic signals that can reduce vehicle queuing lengths, especially on the dominant approach, when unbalanced traffic flow conditions occur... Signalized metering roundabouts are equipped with advanced loop detectors and traffic signals that can reduce vehicle queuing lengths, especially on the dominant approach, when unbalanced traffic flow conditions occur. At a metering roundabout, changeable queuing lengths and the location of detectors determine signal phase times, which in turn affect queuing length on each approach. To date, most studies have focused on perfor- mance comparisons between normal and metered roundabouts, but have failed to evaluate the effect of detector locations on queuing formations. In addition, no guidelines have been developed to enable practitioners to select the appropriate detector location that would lead to optimum roundabout performance. This study, therefore, formulated a numerical model for the estimation of queuing length at a metering roundabout. The model consists of advance vehicle detectors on two approaches and one traffic signal. In order to calibrate and verify the model, queuing lengths were recorded using two drones for the Old Belair Road metering roundabout in Adelaide, South Australia. In order to assess the fitness of the model, an R2 test was conducted, and the results showed that the numerical model can predict queuing lengths on the controlling and metered approaches with up to 83% of R2 value. Moreover, the estimated queuing lengths were compared against those predicted by the software AIMSUN for the same location and under the same conditions. It is expectedthat the model will assist and guide practitioners in determining the best detector locations for metering roundabouts. 展开更多
关键词 Unbalanced traffic flowmetering roundaboutAdvance detector locationAIMSUNQueuing length estimation model
原文传递
8800DF(R)涡街流量计在铜冶炼中的应用
17
作者 李庚民 段兴文 朱国斌 《金川科技》 2018年第2期39-40,共2页
本文简述8800DF(R)涡街流量计在铜冶炼生产中的使用特点.介绍了8800DF(R)涡街流量计工作原理、优缺点、分类.使用注意事项、选型等。
关键词 8800 df(R)vortex flowmeter Karman VORTEX STREET REYNOLDS number VORTEX occurred body.
原文传递
上一页 1 下一页 到第