The article improves the quality of raw cotton by creating a new transfer device structure for the transportation of cotton in long-distance riots, located in the main building of the ginnery. Both foreign and domesti...The article improves the quality of raw cotton by creating a new transfer device structure for the transportation of cotton in long-distance riots, located in the main building of the ginnery. Both foreign and domestic separator cleaners have been studied. Experiments were carried out on prototype transfer device and the results were obtained. The cleaning efficiency was determined by sampling the cotton entering the separator in the moving device and exiting after the inclined vibrating mesh surface installed after the separator.展开更多
The threshing mixture of Cyperus esculentus(Tiger nut)planted in sandy areas is complex during harvesting,and there are problems of high impurity rate and high cleaning loss rate of the seeds.In this paper,the threshi...The threshing mixture of Cyperus esculentus(Tiger nut)planted in sandy areas is complex during harvesting,and there are problems of high impurity rate and high cleaning loss rate of the seeds.In this paper,the threshing mixture of Cyperus esculentus is taken as the research object,and the suspension speed of each component is measured to design an“airflow+vibration”sieving device.Use the vector polygon method to explore the law of motion of the vibrating sieve,establish the force model of the seeds on the sieve surface,and analyze the conditions for the seeds to penetrate the sieve.According to the principle of seeds penetrating the sieve and long stalks not penetrating the sieve,the geometric model of sieve blades opening degree adjustment mechanism is constructed.Study of the conditions under which long stalks can be thrown out of the machine.The experiment bench of the cleaning device was built,and the evaluation indexes were the rate of seed impurity and the rate of cleaning loss of the device,and the crank speed,sieve blades opening degree and fan speed were used as the experiment factors to study the influence law of each influencing factor on the evaluation index through single-factor experiment.Using response surface methodology to find the optimal combination of working parameters of the cleaning device.To verify the device’s application on the combine harvester to improve the effectiveness of the cleaning operation of the Cyperus esculentus combine harvester.展开更多
Contextualization: Emptying the bladder is a challenging problem for the urological community. Intermittent catheterization is the most widely used method to restore bladder emptying mechanism. However, this procedure...Contextualization: Emptying the bladder is a challenging problem for the urological community. Intermittent catheterization is the most widely used method to restore bladder emptying mechanism. However, this procedure can have a negative impact on self-image and result in a decline in the quality of life of patients. In this context, the use of a bladder emptying device (SVCATH3D) proposes to be effective and have a positive impact on the quality of life of different patients. Objective: The objective of the study was to evaluate the functionality of a new device for both intermittent and controlled emptying of the bladder in both sexes and ages. Materials and methods: A randomized clinical trial was conducted with 251 patients, with different bladder problems, from March 2013 to January 2023. After randomization, the patients were divided into two groups: Group I (SVCATH3D) and Group II (Clean Intermittent Catheterization). The primary outcome was defined as the impact on quality of life. Data on episodes of urinary tract infection, adverse effects, number of diaper use and treatment costs were analyzed. Results: The apposition of the SVCATH3D was performed on an outpatient basis, with no complications during the procedures. The patients were followed up for 10 years. There was a significant improvement in quality of life when comparing the moments before and after the use of SVCATH3D (p Conclusion: The study using SVCATH3D showed promising results in relation to functionality, showing improvement in quality of life with a reduction in episodes of urinary infection and amount of diapers/day. This allows us to conclude that SVCATH3D can represent an important step in the treatment of patients suffering from various bladder problems both incontinence and affecting emptying mechanism.展开更多
汽车尾气排放是空气污染最主要的来源之一,已有技术以机内净化技术和机外净化技术为主,少有关注如何从发动机前端入手减少汽车尾气污染物排放。Warp Air Clean(WAC)装置可以通过静电作用改善发动机进气质量,优化发动机燃烧过程,因此基...汽车尾气排放是空气污染最主要的来源之一,已有技术以机内净化技术和机外净化技术为主,少有关注如何从发动机前端入手减少汽车尾气污染物排放。Warp Air Clean(WAC)装置可以通过静电作用改善发动机进气质量,优化发动机燃烧过程,因此基于国五Ⅰ型测试进行了WAC装置减排效果研究。结果表明:(1)WAC装置对汽油车尾气排放的总碳氢化合物(THC)、CO、氮氧化物(NO_(x))、颗粒物(PM)、CH_(4)和非甲烷总烃(NMHC)都有着较好的减排效果;(2)总体而言,WAC装置对汽油车旧车的减排效果优于新车;(3)对汽油车THC、CH_(4)和NMHC的市区工况减排效果优于市郊工况,而对CO和NO_(x)的市郊工况减排效果优于市区工况;(4)对不超过九座的载客车辆的减排效果优于最大设计总质量不超过3500 kg的载货车辆。展开更多
柴油车是城市氮氧化物和颗粒物污染的主要来源之一。以一种新型的发动机前端空气净化技术(warp air clean,WAC)为研究对象,研究其对7辆柴油货车在怠速和自由加速阶段的减排效果。结果表明:WAC对柴油货车一氧化碳(CO)、氮氧化物(NO_(x))...柴油车是城市氮氧化物和颗粒物污染的主要来源之一。以一种新型的发动机前端空气净化技术(warp air clean,WAC)为研究对象,研究其对7辆柴油货车在怠速和自由加速阶段的减排效果。结果表明:WAC对柴油货车一氧化碳(CO)、氮氧化物(NO_(x))、碳氢化合物(HC)和颗粒物数量(particulate number,PN)的平均减排率分别为12.2%、2.9%、3.9%和11.3%;不同排放标准下,WAC对国Ⅲ车辆的净化效果更佳。同一排放标准下,轻型柴油车的减排效果要优于重型柴油车;怠速(空挡)阶段,WAC对使用年限长、排放标准低的车辆净化效果更佳;自由加速阶段,WAC对CO、NO_(x)和HC的净化作用主要表现为降低车辆加速过程中气体污染物排放的峰值,最高分别可达70.6%、50.0%和38.6%。展开更多
Objective: To evaluate the safety and effectiveness of eyelid margin cleaning using Deep Cleaning Device for the treatment of meibomian gland dysfunction-associated dry eye. Methods: This was a prospective, randomized...Objective: To evaluate the safety and effectiveness of eyelid margin cleaning using Deep Cleaning Device for the treatment of meibomian gland dysfunction-associated dry eye. Methods: This was a prospective, randomized, open-label, investigator-masked, and self-controlled study. We randomly assigned one eye of patients with meibomian gland dysfunction-associated dry eye to the treatment group, and the other eye to the control group. Both groups received artificial tears and lid warming;the treatment group received an additional one-time in-office eyelid margin cleaning using Deep Cleaning Device. Non-invasive tear break-up time(NITBUT) and tear meniscus height(TMH) of each eye, and Standard Patient Evaluation for Eye Dryness II(SPEED II) score of each patient were evaluated before and at one week after treatment. Results: Thirty eyes of 15 patients were enrolled. No adverse effects occurred during the treatment. Compared with the baseline values, the SPEED score decreased significantly at one week after treatment(mean±95% confidence interval, 11.00±0.99 vs. 5.67±1.67, P<0.0001), the NITBUT-first in the treatment group increased significantly at one week after treatment((4.74±1.27) s vs.(7.49±2.22) s, P=0.01). The NITBUT-first was significantly longer in the treatment group((7.49±2.22) s) than in the control group((5.17±0.91) s) at one week after treatment(P=0.042). No significant differences were found in other tear film parameters between the two groups. Conclusions: Eyelid margin cleaning using the novel Deep Cleaning Device is a convenient, effective, and safe treatment for patients with meibomian gland dysfunction-associated dry eye.展开更多
文摘The article improves the quality of raw cotton by creating a new transfer device structure for the transportation of cotton in long-distance riots, located in the main building of the ginnery. Both foreign and domestic separator cleaners have been studied. Experiments were carried out on prototype transfer device and the results were obtained. The cleaning efficiency was determined by sampling the cotton entering the separator in the moving device and exiting after the inclined vibrating mesh surface installed after the separator.
基金supported by the Division City Science and Technology Achievement Transformation Guidance Plan Project(Development and demonstration of Cyperus esculentus harvesting machine in sandy areas of Xinjiang)(Grant No.KJ2023CG01)the Science and Technology Plan Project of the Corps-Science and Technology Talent Category:Analysis of Clogging Process of Roller Screen Holes in Cyperus esculentus Harvester and Research on Reverse Friction Declogging Methods(Grant No.2024DB016)the Science and Technology Research Program of Shihezi University:Development and Demonstration of High-Efficiency Harvesting Equipment for Cyperus esculentus Using Dual-Layer Differential Speed Roller Screens(Grant No.KJGG202404).
文摘The threshing mixture of Cyperus esculentus(Tiger nut)planted in sandy areas is complex during harvesting,and there are problems of high impurity rate and high cleaning loss rate of the seeds.In this paper,the threshing mixture of Cyperus esculentus is taken as the research object,and the suspension speed of each component is measured to design an“airflow+vibration”sieving device.Use the vector polygon method to explore the law of motion of the vibrating sieve,establish the force model of the seeds on the sieve surface,and analyze the conditions for the seeds to penetrate the sieve.According to the principle of seeds penetrating the sieve and long stalks not penetrating the sieve,the geometric model of sieve blades opening degree adjustment mechanism is constructed.Study of the conditions under which long stalks can be thrown out of the machine.The experiment bench of the cleaning device was built,and the evaluation indexes were the rate of seed impurity and the rate of cleaning loss of the device,and the crank speed,sieve blades opening degree and fan speed were used as the experiment factors to study the influence law of each influencing factor on the evaluation index through single-factor experiment.Using response surface methodology to find the optimal combination of working parameters of the cleaning device.To verify the device’s application on the combine harvester to improve the effectiveness of the cleaning operation of the Cyperus esculentus combine harvester.
文摘Contextualization: Emptying the bladder is a challenging problem for the urological community. Intermittent catheterization is the most widely used method to restore bladder emptying mechanism. However, this procedure can have a negative impact on self-image and result in a decline in the quality of life of patients. In this context, the use of a bladder emptying device (SVCATH3D) proposes to be effective and have a positive impact on the quality of life of different patients. Objective: The objective of the study was to evaluate the functionality of a new device for both intermittent and controlled emptying of the bladder in both sexes and ages. Materials and methods: A randomized clinical trial was conducted with 251 patients, with different bladder problems, from March 2013 to January 2023. After randomization, the patients were divided into two groups: Group I (SVCATH3D) and Group II (Clean Intermittent Catheterization). The primary outcome was defined as the impact on quality of life. Data on episodes of urinary tract infection, adverse effects, number of diaper use and treatment costs were analyzed. Results: The apposition of the SVCATH3D was performed on an outpatient basis, with no complications during the procedures. The patients were followed up for 10 years. There was a significant improvement in quality of life when comparing the moments before and after the use of SVCATH3D (p Conclusion: The study using SVCATH3D showed promising results in relation to functionality, showing improvement in quality of life with a reduction in episodes of urinary infection and amount of diapers/day. This allows us to conclude that SVCATH3D can represent an important step in the treatment of patients suffering from various bladder problems both incontinence and affecting emptying mechanism.
基金国家重点研发计划项目“基于Warp Air Clean技术净化机动车尾气和提升燃油效率的合作研究”(No.2017YFE0116500)。
文摘汽车尾气排放是空气污染最主要的来源之一,已有技术以机内净化技术和机外净化技术为主,少有关注如何从发动机前端入手减少汽车尾气污染物排放。Warp Air Clean(WAC)装置可以通过静电作用改善发动机进气质量,优化发动机燃烧过程,因此基于国五Ⅰ型测试进行了WAC装置减排效果研究。结果表明:(1)WAC装置对汽油车尾气排放的总碳氢化合物(THC)、CO、氮氧化物(NO_(x))、颗粒物(PM)、CH_(4)和非甲烷总烃(NMHC)都有着较好的减排效果;(2)总体而言,WAC装置对汽油车旧车的减排效果优于新车;(3)对汽油车THC、CH_(4)和NMHC的市区工况减排效果优于市郊工况,而对CO和NO_(x)的市郊工况减排效果优于市区工况;(4)对不超过九座的载客车辆的减排效果优于最大设计总质量不超过3500 kg的载货车辆。
文摘柴油车是城市氮氧化物和颗粒物污染的主要来源之一。以一种新型的发动机前端空气净化技术(warp air clean,WAC)为研究对象,研究其对7辆柴油货车在怠速和自由加速阶段的减排效果。结果表明:WAC对柴油货车一氧化碳(CO)、氮氧化物(NO_(x))、碳氢化合物(HC)和颗粒物数量(particulate number,PN)的平均减排率分别为12.2%、2.9%、3.9%和11.3%;不同排放标准下,WAC对国Ⅲ车辆的净化效果更佳。同一排放标准下,轻型柴油车的减排效果要优于重型柴油车;怠速(空挡)阶段,WAC对使用年限长、排放标准低的车辆净化效果更佳;自由加速阶段,WAC对CO、NO_(x)和HC的净化作用主要表现为降低车辆加速过程中气体污染物排放的峰值,最高分别可达70.6%、50.0%和38.6%。
基金Project supported by the Key Research&Development Projects of Zhejiang Province(No.2018C03082)the Health Commission of Zhejiang Province(Nos.WKJ-ZJ-1905 and 2018ZD007),China
文摘Objective: To evaluate the safety and effectiveness of eyelid margin cleaning using Deep Cleaning Device for the treatment of meibomian gland dysfunction-associated dry eye. Methods: This was a prospective, randomized, open-label, investigator-masked, and self-controlled study. We randomly assigned one eye of patients with meibomian gland dysfunction-associated dry eye to the treatment group, and the other eye to the control group. Both groups received artificial tears and lid warming;the treatment group received an additional one-time in-office eyelid margin cleaning using Deep Cleaning Device. Non-invasive tear break-up time(NITBUT) and tear meniscus height(TMH) of each eye, and Standard Patient Evaluation for Eye Dryness II(SPEED II) score of each patient were evaluated before and at one week after treatment. Results: Thirty eyes of 15 patients were enrolled. No adverse effects occurred during the treatment. Compared with the baseline values, the SPEED score decreased significantly at one week after treatment(mean±95% confidence interval, 11.00±0.99 vs. 5.67±1.67, P<0.0001), the NITBUT-first in the treatment group increased significantly at one week after treatment((4.74±1.27) s vs.(7.49±2.22) s, P=0.01). The NITBUT-first was significantly longer in the treatment group((7.49±2.22) s) than in the control group((5.17±0.91) s) at one week after treatment(P=0.042). No significant differences were found in other tear film parameters between the two groups. Conclusions: Eyelid margin cleaning using the novel Deep Cleaning Device is a convenient, effective, and safe treatment for patients with meibomian gland dysfunction-associated dry eye.