This study was to develop the real-time fluorescence quantitative PCR technique for detecting the ratoon stunting disease (RSD) in virus-free seedcane seedlings. Healthy tissue culture seedlings were obtained from s...This study was to develop the real-time fluorescence quantitative PCR technique for detecting the ratoon stunting disease (RSD) in virus-free seedcane seedlings. Healthy tissue culture seedlings were obtained from six plants of sugarcane ROC22, which had been confirmed RSD-positive by detecting the sugarcane juice, by employing the sugarcane seedlings production protocol. Real-time fluorescence quantitative PCR was used to detect RSD pathogens in tissue culture sam- pies. The results showed that target fragment of RSD pathogens was not found in all 10 samples in real-time fluorescence quantitative PCR, with the Ct values of 37 - 39. The healthy tissue culture sugarcane seedlings do not carry RSD pathogens, indicating that adopting healthy seedcane seedlings production technique could thoroughly get rid of RSD pathogens.展开更多
[ Objective] This study aimed to establish a simultaneous detection method of shrimp viruses by real-time fluorescence quantitative RT-PCR, to improve the efficiency of inspection and quarantine. [ Method] A novel rea...[ Objective] This study aimed to establish a simultaneous detection method of shrimp viruses by real-time fluorescence quantitative RT-PCR, to improve the efficiency of inspection and quarantine. [ Method] A novel real-time fluorescence quantitative RT-PCR assay was established and optimized for simultaneously detecting DNA/RNA of four shrimp viruses (WSSV, IHHNV, TSV and YHV ). [ Result] The optimized real-time fluorescence quantitative RT-PCR system gener- ated typical amplification curves with high amplification efficiencies (E = 1.06, 1.07, 0.92 and 0.92, respectively), good hnear relationship ( r = 1 ), uniform repeatability ( standard deviation = 0.05 - 0.46 ; variation coefficient = 0.26% - 1.62% ) and high sensitivity, exhibiting no significant differences compared with re- al-time fluorescence quantitative PCR (average error of Ct value = 0.04 -0.40; T = 0.53 -2.50; P 〉 0.05 ). The total detection time was about 1 h. [ Conclusion] The optimized real-time fluorescence quantitative RT-PCR system can be used for rapid detection of WSSV, IHHNV, TSV and YHV.展开更多
Objective: Multidrug resistance(MDR) is one of the most important reasons for treatment failure and recurrence of acute leukemia. Its manifestations are different in children with acute lymphoblastic leukemia(ALL...Objective: Multidrug resistance(MDR) is one of the most important reasons for treatment failure and recurrence of acute leukemia. Its manifestations are different in children with acute lymphoblastic leukemia(ALL) which may be due to different detection methods. This study was to detect the expression of MDR1 mRNA in bone marrow cells of children with ALL by real-time fluorescence- quantitative reverse transcription polymerase-chain reaction(FQ-RT-PCR), and combine minimal residual desease(MRD) detection by flow cytometry(FCM) and to study their relationship with treatment response and prognosis of ALL. Methods:The MDR1 mRNA levels in bone marrow cells from 67 children with ALL[28 had newly diagnosed disease, 27 had achieved complete remission(CR), 12 recurrent] and 22 children without leukemia were detected by FQ-RT-PCR. MRD was detected by FCM. The patients were observed for 9-101 months, with a median of 64 months. Results:Standard curves of human MDR1 and GAPDH genes were constructed successfully. MDR1 mRNA was detected in all children with a positive rate of 100%. The mRNA level of MDR1 was similar among the newly diagnosed ALL group, CR group, and control group(P 〉 0.05), but significantly higher in the recurrence group than that in newly diagnosed disease group and control group(0.50 ± 0.55 vs. 0.09 ± 0.26 and 0.12 ± 0.23, P〈 0.05). 54 ALL patients were followed up, and it was found that MDR1 mRNA level was significantly higher in ALL patients within 3 years duration than that of ALL patients with 3-6 years and over 6 years duration(0.63 ± 0.56 vs. 0.11 ± 0.12 and 0.04 ± 0.06, P〈 0.01). For the 28 children with newly diagnosed disease, the MDR1 mRNA level was similar between WBC 〉 50 ~ 109 group and WBC〈50 × 10^9 group(P〉 0.05). In the 33 CR patients, the MDR1 mRNA level was significantly higher in MRD〉10a group than that in MRD〈10a group(0.39 ± 0.47 vs. 0.03 ± 0.03, P 〈 0.05). Conclusion:The sensitivity and specificity of FQ-RT-PCR in detecting MDR1 mRNA in bone marrowy cells of children with ALL patients are high. MDR1 mRNA is expressed in children with and without leukemia. MDR1 mRNA is highly expressed in the CR ALL patients with high MRD, recurrence and short duration(within 3 years). Monitoring MRD and the MDR1 mRNA level might be helpful for individual treatment.展开更多
According to VP2 gene sequence of the porcine parvovirus virus strain NADL-2 (NC001718) available in GenBank (NC_001718), a pair of specific primer was designed, and the target fragment of 431 bp was obtained by P...According to VP2 gene sequence of the porcine parvovirus virus strain NADL-2 (NC001718) available in GenBank (NC_001718), a pair of specific primer was designed, and the target fragment of 431 bp was obtained by PCR amplification. The products were ligated with pMD18- T vector and then transformed into bacteria DH5α for recombinant plasmid extraction. After PCR identification and sequencing, recombinant plasmid was used as a standard template to establish the standard curve of SYBR Green I fluorescence quantitative PCR. Sensitivity test, specificity test and repeatability test were also determined. The results indicated that there was a good linear relationship between threshold cycle of the standard curve and template concentration, R2 =0.997 6. Tm ranged from 82.3 to 82.9 ℃, while the sensitivity was 72.1 copies/μl with good specificity and repeatability. The developed SYBR Green I real-time quantitative PCR method to detect PPV VP2 gene laid the basis for further studies on patho- oenesis, early clinical diaonosis of this virus and quantitative analysis of PPV infection.展开更多
[ Objective ] This study aimed to establish a rapid and effective quarantine method of Koi herpes virus. [ Method] Primers and corresponding TaqMan probe were designed based on the conserved sequence of Koi herpes vir...[ Objective ] This study aimed to establish a rapid and effective quarantine method of Koi herpes virus. [ Method] Primers and corresponding TaqMan probe were designed based on the conserved sequence of Koi herpes virus (KHV) pol-ymerase gene (Sph) to establish a rapid and effective fluorescence quantitative PCR method for Koi herpes virus detection. The cell cultures were detected by using the established fluorescence quantitative PCR assay, and the results were com- pared with that of conventional PCR. [ Result] The sensitivity of fluorescence quantitative PCR was higher than that of conventional PCR. The minimum copy num- ber that could be detected was 1.6 - 102 copies/p.1. The established method was adopted for sample detection, and a reliable diagnostic result could be obtained within 4 h. [Conclusion] The established method is rapid, sensitive, specific and repeatable, which is conducive to the rapid detection of Koi herpes virus. Key words Koi herpes virus; Fluorescence quantitative PCR; Detection展开更多
Real-time fluorescent quantitative PCR (RQ-PCR) is a detection method by adding fluorescent dye or fluorescent probe into the PCR reaction system, using fluorescent signal accumulation to monitor amplification react...Real-time fluorescent quantitative PCR (RQ-PCR) is a detection method by adding fluorescent dye or fluorescent probe into the PCR reaction system, using fluorescent signal accumulation to monitor amplification reactions of PCR reaction process, and finally the unknown template can be quantitatively analyzed through the standard curve. So the detection level of PCR has improved from the qualitative to the quantitative. In order to provide a theoretical reference for further application, the principle, classification, advantages and disadvantages of RQ-PCR were intro- duced, and its application and progress in plants in recent years were reviewed.展开更多
Objective:To explore a method to solve the issue of interference in fluorescence quantitative PCR non-specific amplification for gene detection.Method:A three-step method was used for amplification,and the quantitativ...Objective:To explore a method to solve the issue of interference in fluorescence quantitative PCR non-specific amplification for gene detection.Method:A three-step method was used for amplification,and the quantitative fluorescence signal collection process was set in the extension stage.Results:Three-step amplification has the advantages of wide application range;improved accuracy;and reduced primer design requirements.Conclusion:The interference of non-specific amplification signals was effectively avoided,the melting curve plotting process was omitted,the reaction time was shortened,and the detection accuracy was improved.展开更多
The species distinctive PCR primer of Lactobacillus acidophilus ( L. acidophilus) was designed according to 16S rRNA gene sequences of conunon Lac- tobacillus species in fermented material. Bacterial genome DNA of s...The species distinctive PCR primer of Lactobacillus acidophilus ( L. acidophilus) was designed according to 16S rRNA gene sequences of conunon Lac- tobacillus species in fermented material. Bacterial genome DNA of separated L. acidophilus in fermented sample was taken as template, and L. acidophilus in fer- mented material was conducted the quantitative determination by real-time quantitative PCR (RT-PCR). Analysis on RT-PCR results shown that contents of L. aci- dophilus in the test sample reached 1.5 billion CFU / g. Test results shown that contents of L. acidophilus in fermented material could be detected accurately by the established RT-PCR method in the test. indicating that the established RT-PCR method could be aookued to the detection of L. acidophilus in fermented material.展开更多
Real-Lime fluorescent quantitative PCR is a method for quantitative analysis of gene expression developed in recent years, which has been widely used in various fields such as basic scientific research, clinical diagn...Real-Lime fluorescent quantitative PCR is a method for quantitative analysis of gene expression developed in recent years, which has been widely used in various fields such as basic scientific research, clinical diagnosis, disease study, drug research and development since its appearance. It starts relatively late in study on plants, but has already been used for analysis of gene expression in plants and gene identification of exogenous genes. The principles or advantages and dis- advantages of real-time fluorescent quantitative PCR, or its potential problems and condition optimizations in tests were introduced in this study, and then the appli- cation and prospect of real-time fluorescent quantitative PCR in study on plants were also been discussed.展开更多
A reliable and sensitive competitive real-time fluorescent quantitative immuno-PCR (RTFQ-IPCR) assay using a molecular beacon was developed for the determination of trace fluoranthene (FL) in the environment.Under...A reliable and sensitive competitive real-time fluorescent quantitative immuno-PCR (RTFQ-IPCR) assay using a molecular beacon was developed for the determination of trace fluoranthene (FL) in the environment.Under optimized assay conditions,FL can be determined in the concentration range from 1 fg/mL to 100 ng/mL,with y=0.194x + 7.859,and a correlation coefficient of 0.967 was identified,with a detection limit of 0.6 fg/mL.Environmental water samples were successfully analyzed,recovery was between 90% and 116%,with intra-day relative standard deviation (RSD) of 6.7%-12.8% and inter-day RSD of 8.4%-15.2%.The results obtained from RTFQ-IPCR were confirmed by ELISA,showing good accuracy and suitability to analyze FL in field samples.As a highly sensitive method,the molecular beacon-based RTFQ-IPCR is acceptable and promising for providing reliable test results to make environmental decisions.展开更多
In order to improve the standardized technical systems of quantitative analyses for genetically modified organisms (GMOs) and products, ensure bio-safety and reduce ecological risk in China, a real-time fluorescent ...In order to improve the standardized technical systems of quantitative analyses for genetically modified organisms (GMOs) and products, ensure bio-safety and reduce ecological risk in China, a real-time fluorescent quantitative PCR assay was established for detection of genetically modified maize line MON88017. The established method was evaluated based on the specificity, sensitivity, accuracy and measurement uncertainty. The results showed that the established method had strong specificity in detection of genetically modified maize line MON88017. 1.50% MON88017 sample was detected with 29 replica- tions. The average measured value ( 1. 541% ) was close to the actual value ( 1.50% ) and the relative deviation was 2.70%. The variation coefficient of the measured value was 0.110 g ; the recovery was 100.00% and the measurement uncertainty was 0. 096. The limit of detection for genetically modified maize line MON88017 with the established method was 5 copies at the 97.5% confidence level. Thus, the real-time fluorescent quantitative PCR assay established in this study exhibited high specificity, accuracy and sensitivity, which could provide technical support for the safety supervision of genetically modified organ- isms and products in China.展开更多
[Objective] This paper was to develop a fluorescence quantitative PCR method for detection of M. refringens in shellfish. [Method] A pair of primers and a TaqMan probe were designed and synthesized according to the co...[Objective] This paper was to develop a fluorescence quantitative PCR method for detection of M. refringens in shellfish. [Method] A pair of primers and a TaqMan probe were designed and synthesized according to the conserved gene sequences of M. refringens in GenBank, so as to develop a fluorescence quantitative PCR method for detection of M. refringens. The developed fluorescence quantitative PCR method was compared with conventional PCR detection. [Result] The fluorescence quantitative PCR could detect 40 template copies of plasmid DNA, and its sensitivity was 100 times higher than the conventional PCR. The detection results of Perkinsus sp, Haplosporidium sp, Aeromonas hydrophila, Pseudomonas fluorescens, Vibrio parahaemolyticu, Vibrio alginolyticu, Vibrio rluvialis and Vibrio mimicus were negtive. [Conclusion] The fluorescence quantitative PCR method for M. refringens established in this paper is specific, sensitive, rapid and quantitative with good repeatability, which can be used for clinical detection of M. refringens infection.展开更多
[ Objective ] To establish a real-time fluorescent quantitative polymerase chain reaction (PCR) method with SYBR Green I for the detection of porcine circovirus type 2 (PCV2). [Methods] Specific primers were desig...[ Objective ] To establish a real-time fluorescent quantitative polymerase chain reaction (PCR) method with SYBR Green I for the detection of porcine circovirus type 2 (PCV2). [Methods] Specific primers were designed to amplify the conserved gene segments of PCV2 with a size of 177 bp by PCR. The ampli- fied gene was cloned into the vector of pMD 18-T and transformed into DHSct to screen positive clones. After being extracted and purified, the recombinant plasraids pMD 18-T-177 were taken as the standard DNA templates to establish the fluorescence quantitative PCR method for the detection of PCV2, and the PCR re- action conditions were optimized. [ Results] Ct value of the established PCR method showed a good linear relationship with the standard DNA templates within a viral load of 3.21 × 100 -4.16 × 108 copies/μL , the correlation coefficient was O. 998 8 and the slope was - 3.286. The method did not show any cress-reactions with the genomes of PRRSV, PCV1, CSFV, PRV, PPV and Escherichia coli. Sensitivity of this method was proved to be 3.21 × 10 copies/μL, which was 1 000 times higher as conventional PCR method. Variation coefficients of the repeated trims among same batch or different batches were both less than 3.00%. Positive rate of clinical samples detected by the established PCR method was 58.94%, which was significantly higher than the detection rate by conventional PCR. [ Conclusions ] A reM-time fluorescent quantitative PCR method with SYBR Green I for the detection of PCV2 was established, which was better for conducting the quan- titative analysis and the early diagnosis of PCV2 infection.展开更多
Objective: In the prenatal screening, several different methods were used to detect the presence of group B streptococcus (GBS) infection, in this assay, the diagnostic value and clinical significance of the applicati...Objective: In the prenatal screening, several different methods were used to detect the presence of group B streptococcus (GBS) infection, in this assay, the diagnostic value and clinical significance of the application of realtime fluorescent PCR were explored. Methods: A total of 86 women with 35-37 weeks pregnancy were enrolled, vaginal secretion samples were collected. Fluorescence PCR, bacterial culture and gene sequencing were used to detect whether there was GBS infection, and the results obtained were compared and analyzed. Results: 10 subjects were detected to be positive for GBS by fluorescence PCR (the positive rate was 11.6%), however, only 4 cases were positive for GBS by bacterial culture method (the positive rate was 4.7%). There was a statistically significant difference in the positive rate between the two methods (P<0.01). Compared with the results of gene sequencing, the detection of GBS infection by fluorescence PCR has an accuracy of 95.2%, and the sensitivity was 90.9% with 100% specificity. Conclusion: The application of realtime fluorescence quantitative PCR for the detection of GBS infection is significantly better than the use of bacterial culture method. Compared with the gold standard method (gene sequencing method), its detection efficiency, accuracy, sensitivity and specificity are relatively high. In summary, PCR for prenatal screening of GBS is worthy of promotion in clinical practice.展开更多
基金Supported by Special Funds for Basic Scientific Research of Guangxi Sugarcane Research Institute(G2009006,G2010006,G2009015)Sci-tech Research and Development Program of Guangxi Academy of Agricultural Sciences(200805)
文摘This study was to develop the real-time fluorescence quantitative PCR technique for detecting the ratoon stunting disease (RSD) in virus-free seedcane seedlings. Healthy tissue culture seedlings were obtained from six plants of sugarcane ROC22, which had been confirmed RSD-positive by detecting the sugarcane juice, by employing the sugarcane seedlings production protocol. Real-time fluorescence quantitative PCR was used to detect RSD pathogens in tissue culture sam- pies. The results showed that target fragment of RSD pathogens was not found in all 10 samples in real-time fluorescence quantitative PCR, with the Ct values of 37 - 39. The healthy tissue culture sugarcane seedlings do not carry RSD pathogens, indicating that adopting healthy seedcane seedlings production technique could thoroughly get rid of RSD pathogens.
文摘[ Objective] This study aimed to establish a simultaneous detection method of shrimp viruses by real-time fluorescence quantitative RT-PCR, to improve the efficiency of inspection and quarantine. [ Method] A novel real-time fluorescence quantitative RT-PCR assay was established and optimized for simultaneously detecting DNA/RNA of four shrimp viruses (WSSV, IHHNV, TSV and YHV ). [ Result] The optimized real-time fluorescence quantitative RT-PCR system gener- ated typical amplification curves with high amplification efficiencies (E = 1.06, 1.07, 0.92 and 0.92, respectively), good hnear relationship ( r = 1 ), uniform repeatability ( standard deviation = 0.05 - 0.46 ; variation coefficient = 0.26% - 1.62% ) and high sensitivity, exhibiting no significant differences compared with re- al-time fluorescence quantitative PCR (average error of Ct value = 0.04 -0.40; T = 0.53 -2.50; P 〉 0.05 ). The total detection time was about 1 h. [ Conclusion] The optimized real-time fluorescence quantitative RT-PCR system can be used for rapid detection of WSSV, IHHNV, TSV and YHV.
基金This work was supported by Science Project from Science and Tech- nology Department of HuBei province(2006AA301B56-3)
文摘Objective: Multidrug resistance(MDR) is one of the most important reasons for treatment failure and recurrence of acute leukemia. Its manifestations are different in children with acute lymphoblastic leukemia(ALL) which may be due to different detection methods. This study was to detect the expression of MDR1 mRNA in bone marrow cells of children with ALL by real-time fluorescence- quantitative reverse transcription polymerase-chain reaction(FQ-RT-PCR), and combine minimal residual desease(MRD) detection by flow cytometry(FCM) and to study their relationship with treatment response and prognosis of ALL. Methods:The MDR1 mRNA levels in bone marrow cells from 67 children with ALL[28 had newly diagnosed disease, 27 had achieved complete remission(CR), 12 recurrent] and 22 children without leukemia were detected by FQ-RT-PCR. MRD was detected by FCM. The patients were observed for 9-101 months, with a median of 64 months. Results:Standard curves of human MDR1 and GAPDH genes were constructed successfully. MDR1 mRNA was detected in all children with a positive rate of 100%. The mRNA level of MDR1 was similar among the newly diagnosed ALL group, CR group, and control group(P 〉 0.05), but significantly higher in the recurrence group than that in newly diagnosed disease group and control group(0.50 ± 0.55 vs. 0.09 ± 0.26 and 0.12 ± 0.23, P〈 0.05). 54 ALL patients were followed up, and it was found that MDR1 mRNA level was significantly higher in ALL patients within 3 years duration than that of ALL patients with 3-6 years and over 6 years duration(0.63 ± 0.56 vs. 0.11 ± 0.12 and 0.04 ± 0.06, P〈 0.01). For the 28 children with newly diagnosed disease, the MDR1 mRNA level was similar between WBC 〉 50 ~ 109 group and WBC〈50 × 10^9 group(P〉 0.05). In the 33 CR patients, the MDR1 mRNA level was significantly higher in MRD〉10a group than that in MRD〈10a group(0.39 ± 0.47 vs. 0.03 ± 0.03, P 〈 0.05). Conclusion:The sensitivity and specificity of FQ-RT-PCR in detecting MDR1 mRNA in bone marrowy cells of children with ALL patients are high. MDR1 mRNA is expressed in children with and without leukemia. MDR1 mRNA is highly expressed in the CR ALL patients with high MRD, recurrence and short duration(within 3 years). Monitoring MRD and the MDR1 mRNA level might be helpful for individual treatment.
文摘According to VP2 gene sequence of the porcine parvovirus virus strain NADL-2 (NC001718) available in GenBank (NC_001718), a pair of specific primer was designed, and the target fragment of 431 bp was obtained by PCR amplification. The products were ligated with pMD18- T vector and then transformed into bacteria DH5α for recombinant plasmid extraction. After PCR identification and sequencing, recombinant plasmid was used as a standard template to establish the standard curve of SYBR Green I fluorescence quantitative PCR. Sensitivity test, specificity test and repeatability test were also determined. The results indicated that there was a good linear relationship between threshold cycle of the standard curve and template concentration, R2 =0.997 6. Tm ranged from 82.3 to 82.9 ℃, while the sensitivity was 72.1 copies/μl with good specificity and repeatability. The developed SYBR Green I real-time quantitative PCR method to detect PPV VP2 gene laid the basis for further studies on patho- oenesis, early clinical diaonosis of this virus and quantitative analysis of PPV infection.
基金Supported by Project of Jilin Province Science and Technology Commission(20080218)
文摘[ Objective ] This study aimed to establish a rapid and effective quarantine method of Koi herpes virus. [ Method] Primers and corresponding TaqMan probe were designed based on the conserved sequence of Koi herpes virus (KHV) pol-ymerase gene (Sph) to establish a rapid and effective fluorescence quantitative PCR method for Koi herpes virus detection. The cell cultures were detected by using the established fluorescence quantitative PCR assay, and the results were com- pared with that of conventional PCR. [ Result] The sensitivity of fluorescence quantitative PCR was higher than that of conventional PCR. The minimum copy num- ber that could be detected was 1.6 - 102 copies/p.1. The established method was adopted for sample detection, and a reliable diagnostic result could be obtained within 4 h. [Conclusion] The established method is rapid, sensitive, specific and repeatable, which is conducive to the rapid detection of Koi herpes virus. Key words Koi herpes virus; Fluorescence quantitative PCR; Detection
基金Supported by National Natural Science Foundation of China(31260406)Natural Science Fund Project of Inner Mongolia(2012MS0502)~~
文摘Real-time fluorescent quantitative PCR (RQ-PCR) is a detection method by adding fluorescent dye or fluorescent probe into the PCR reaction system, using fluorescent signal accumulation to monitor amplification reactions of PCR reaction process, and finally the unknown template can be quantitatively analyzed through the standard curve. So the detection level of PCR has improved from the qualitative to the quantitative. In order to provide a theoretical reference for further application, the principle, classification, advantages and disadvantages of RQ-PCR were intro- duced, and its application and progress in plants in recent years were reviewed.
文摘Objective:To explore a method to solve the issue of interference in fluorescence quantitative PCR non-specific amplification for gene detection.Method:A three-step method was used for amplification,and the quantitative fluorescence signal collection process was set in the extension stage.Results:Three-step amplification has the advantages of wide application range;improved accuracy;and reduced primer design requirements.Conclusion:The interference of non-specific amplification signals was effectively avoided,the melting curve plotting process was omitted,the reaction time was shortened,and the detection accuracy was improved.
文摘The species distinctive PCR primer of Lactobacillus acidophilus ( L. acidophilus) was designed according to 16S rRNA gene sequences of conunon Lac- tobacillus species in fermented material. Bacterial genome DNA of separated L. acidophilus in fermented sample was taken as template, and L. acidophilus in fer- mented material was conducted the quantitative determination by real-time quantitative PCR (RT-PCR). Analysis on RT-PCR results shown that contents of L. aci- dophilus in the test sample reached 1.5 billion CFU / g. Test results shown that contents of L. acidophilus in fermented material could be detected accurately by the established RT-PCR method in the test. indicating that the established RT-PCR method could be aookued to the detection of L. acidophilus in fermented material.
基金Supported by National Natural Science Foundation of China ( 30800885,30871726)
文摘Real-Lime fluorescent quantitative PCR is a method for quantitative analysis of gene expression developed in recent years, which has been widely used in various fields such as basic scientific research, clinical diagnosis, disease study, drug research and development since its appearance. It starts relatively late in study on plants, but has already been used for analysis of gene expression in plants and gene identification of exogenous genes. The principles or advantages and dis- advantages of real-time fluorescent quantitative PCR, or its potential problems and condition optimizations in tests were introduced in this study, and then the appli- cation and prospect of real-time fluorescent quantitative PCR in study on plants were also been discussed.
基金support by the Scienceand Technology Commission of Shanghai Municipality in China (Key Project of Fundamental Research) (No.09JC1407600)the Science and Technology Commission of Shanghai Municipality in China (Key Project of theScience and Technology Research) (No. 09231202805)the Shanghai Leading Academic Discipline Project(No. B604)
文摘A reliable and sensitive competitive real-time fluorescent quantitative immuno-PCR (RTFQ-IPCR) assay using a molecular beacon was developed for the determination of trace fluoranthene (FL) in the environment.Under optimized assay conditions,FL can be determined in the concentration range from 1 fg/mL to 100 ng/mL,with y=0.194x + 7.859,and a correlation coefficient of 0.967 was identified,with a detection limit of 0.6 fg/mL.Environmental water samples were successfully analyzed,recovery was between 90% and 116%,with intra-day relative standard deviation (RSD) of 6.7%-12.8% and inter-day RSD of 8.4%-15.2%.The results obtained from RTFQ-IPCR were confirmed by ELISA,showing good accuracy and suitability to analyze FL in field samples.As a highly sensitive method,the molecular beacon-based RTFQ-IPCR is acceptable and promising for providing reliable test results to make environmental decisions.
基金Supported by Project of Standardization Technical System from the Administration of Quality and Technology Supervision of Sichuan Province(ZYBZ2013-39)
文摘In order to improve the standardized technical systems of quantitative analyses for genetically modified organisms (GMOs) and products, ensure bio-safety and reduce ecological risk in China, a real-time fluorescent quantitative PCR assay was established for detection of genetically modified maize line MON88017. The established method was evaluated based on the specificity, sensitivity, accuracy and measurement uncertainty. The results showed that the established method had strong specificity in detection of genetically modified maize line MON88017. 1.50% MON88017 sample was detected with 29 replica- tions. The average measured value ( 1. 541% ) was close to the actual value ( 1.50% ) and the relative deviation was 2.70%. The variation coefficient of the measured value was 0.110 g ; the recovery was 100.00% and the measurement uncertainty was 0. 096. The limit of detection for genetically modified maize line MON88017 with the established method was 5 copies at the 97.5% confidence level. Thus, the real-time fluorescent quantitative PCR assay established in this study exhibited high specificity, accuracy and sensitivity, which could provide technical support for the safety supervision of genetically modified organ- isms and products in China.
文摘[Objective] This paper was to develop a fluorescence quantitative PCR method for detection of M. refringens in shellfish. [Method] A pair of primers and a TaqMan probe were designed and synthesized according to the conserved gene sequences of M. refringens in GenBank, so as to develop a fluorescence quantitative PCR method for detection of M. refringens. The developed fluorescence quantitative PCR method was compared with conventional PCR detection. [Result] The fluorescence quantitative PCR could detect 40 template copies of plasmid DNA, and its sensitivity was 100 times higher than the conventional PCR. The detection results of Perkinsus sp, Haplosporidium sp, Aeromonas hydrophila, Pseudomonas fluorescens, Vibrio parahaemolyticu, Vibrio alginolyticu, Vibrio rluvialis and Vibrio mimicus were negtive. [Conclusion] The fluorescence quantitative PCR method for M. refringens established in this paper is specific, sensitive, rapid and quantitative with good repeatability, which can be used for clinical detection of M. refringens infection.
基金Supported by Shandong Province Natural Science Fund Project
文摘[ Objective ] To establish a real-time fluorescent quantitative polymerase chain reaction (PCR) method with SYBR Green I for the detection of porcine circovirus type 2 (PCV2). [Methods] Specific primers were designed to amplify the conserved gene segments of PCV2 with a size of 177 bp by PCR. The ampli- fied gene was cloned into the vector of pMD 18-T and transformed into DHSct to screen positive clones. After being extracted and purified, the recombinant plasraids pMD 18-T-177 were taken as the standard DNA templates to establish the fluorescence quantitative PCR method for the detection of PCV2, and the PCR re- action conditions were optimized. [ Results] Ct value of the established PCR method showed a good linear relationship with the standard DNA templates within a viral load of 3.21 × 100 -4.16 × 108 copies/μL , the correlation coefficient was O. 998 8 and the slope was - 3.286. The method did not show any cress-reactions with the genomes of PRRSV, PCV1, CSFV, PRV, PPV and Escherichia coli. Sensitivity of this method was proved to be 3.21 × 10 copies/μL, which was 1 000 times higher as conventional PCR method. Variation coefficients of the repeated trims among same batch or different batches were both less than 3.00%. Positive rate of clinical samples detected by the established PCR method was 58.94%, which was significantly higher than the detection rate by conventional PCR. [ Conclusions ] A reM-time fluorescent quantitative PCR method with SYBR Green I for the detection of PCV2 was established, which was better for conducting the quan- titative analysis and the early diagnosis of PCV2 infection.
文摘Objective: In the prenatal screening, several different methods were used to detect the presence of group B streptococcus (GBS) infection, in this assay, the diagnostic value and clinical significance of the application of realtime fluorescent PCR were explored. Methods: A total of 86 women with 35-37 weeks pregnancy were enrolled, vaginal secretion samples were collected. Fluorescence PCR, bacterial culture and gene sequencing were used to detect whether there was GBS infection, and the results obtained were compared and analyzed. Results: 10 subjects were detected to be positive for GBS by fluorescence PCR (the positive rate was 11.6%), however, only 4 cases were positive for GBS by bacterial culture method (the positive rate was 4.7%). There was a statistically significant difference in the positive rate between the two methods (P<0.01). Compared with the results of gene sequencing, the detection of GBS infection by fluorescence PCR has an accuracy of 95.2%, and the sensitivity was 90.9% with 100% specificity. Conclusion: The application of realtime fluorescence quantitative PCR for the detection of GBS infection is significantly better than the use of bacterial culture method. Compared with the gold standard method (gene sequencing method), its detection efficiency, accuracy, sensitivity and specificity are relatively high. In summary, PCR for prenatal screening of GBS is worthy of promotion in clinical practice.