期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
Fluorescence determination of platinum with dibromohydroxyphenyl-fluorone in microemulsion after separation and enrichment by sulfhydryl dextrose gel 被引量:1
1
作者 LI Huizhi ZHAI Yubo ZHAI Diantang 《Rare Metals》 SCIE EI CAS CSCD 2008年第1期101-105,共5页
A new fluorescence quenching method has been developed for the determination of platinum in nonionic microemulsion medium.This method is based on the fact that platinum can form a stable chelate with dibromohydroxyphe... A new fluorescence quenching method has been developed for the determination of platinum in nonionic microemulsion medium.This method is based on the fact that platinum can form a stable chelate with dibromohydroxyphenyl-fluorine(DBHPF) when they are in the molar ratio of 1:2 in the nonionic microemulsion medium.Under optimum conditions,the system,having the maximum excitation and emission wavelengths at 468 nm and 532 nm,respectively,shows constant fluorescence intensity in the pH range of 3.5-4.0 and high selectivity and sensitivity as well as low interference from foreign ions.Furthermore,this fluorescence intensity is a linear function of Pt(IV) concentration in the range of 0.002-1.00 μg·mL^-1 and the limit of detection is 2.90 ng·mL^-1. 展开更多
关键词 analytical chemistry separation and enrichment fluorescence determination MICROEMULSION platinum(IV)
下载PDF
Fluorescence determination of europium with pyridine-2,4,6-tricarboxylic acid 被引量:1
2
作者 ZHAOJun ZHAOGuohu LIANGHuiguang ZHANGHaobo 《Rare Metals》 SCIE EI CAS CSCD 2005年第2期115-118,共4页
Europium can form a stable chelate with pyridine-2,4,6-tricarboxylic acid (PTA) with a ratio of 1:1 in aqueous. The system, having the maximum excitation and emission wavelengths at 311.0 nm and 616.3 nm, separately, ... Europium can form a stable chelate with pyridine-2,4,6-tricarboxylic acid (PTA) with a ratio of 1:1 in aqueous. The system, having the maximum excitation and emission wavelengths at 311.0 nm and 616.3 nm, separately, shows a constant fluorescence intensity in the pH range of 11.0-12.0. The method has high selectivity and sensitivity as well as low effect from foreign ions. The optimum determinate conditions were obtained. The fluorescence intensity is a linear function of Eu3+, concentration in the range of 0.0029-1.5200 mu g center dot mL(-1) and the limit of detection is 2.90 ng center dot mL(-1). 展开更多
关键词 fluorescent determination EUROPIUM pyridine-2 4 6-tricarboxylic acid LUMINESCENCE
下载PDF
Fluorescence Determination of Tetracycline by Eu(Ⅲ)/TOPO/TC System
3
作者 Huang Chunbao,Ci Yunxiang,Chang Wenbao Department of Chemistry,Peking University,Beijing 100871,China 《Wuhan University Journal of Natural Sciences》 CAS 1999年第1期97-100,共4页
The fluorescence intensity of the europium(Ⅲ) tetracycline (TC)complex can be greatly increased by TOPO,TBP,TTA and surfactans,among which TOPO showed the greatest enhancement.The formation of ternary complex was pr... The fluorescence intensity of the europium(Ⅲ) tetracycline (TC)complex can be greatly increased by TOPO,TBP,TTA and surfactans,among which TOPO showed the greatest enhancement.The formation of ternary complex was proposed to be responsible for the fluorescence enhancement .The Eu(Ⅲ) TOPO TC system can be applied to the determination of trace amounts of tetracycline in urinous sample; the maximum fluorescence intensity was obtained in the pH range of 8.2 ̄9.5 with excitation and emission wavelengths at 396 nm and 616 nm,respectively.The linear range for tetracycline is 6.0×10 -9 5.0×10 -7 mol·L -1 .The detection limit is 2.0×10 -9 mol·L -1 (SNR=3). Experimental conditions and the mechanism of the enhancement effect are discussed. 展开更多
关键词 fluorescence determination tetracycline europium
下载PDF
A FLUORESCENCE QUENCHING IMNUNOASSAY METHOD FOR DETERMINATION OF TRACE ALBUMIN USING UNLABELED EUROPIUM CHELATE
4
作者 Feng Ji YAO Mei HONG Xiao Da YANG Yun Xiang CI Department of Chemistry,Peking University,100871 《Chinese Chemical Letters》 SCIE CAS CSCD 1992年第12期1011-1014,共4页
A fluoroimmunoassay method using unlabeled europium chelate is described.The principle is similar to that of fluoroimmunoassay method using lanthanide chelate as labels.The procedure is simple because labeling process... A fluoroimmunoassay method using unlabeled europium chelate is described.The principle is similar to that of fluoroimmunoassay method using lanthanide chelate as labels.The procedure is simple because labeling process is omitted.The detection limit is about 10^(10) mol/L antigen.The relative standard deviation of immunoassay is less than 10%.The recoveries of human serum albumin and estradiol protein conjugate are 96-105% and 111% respectively. 展开更多
关键词 RSA Eu A fluorescence QUENCHING IMNUNOASSAY METHOD FOR determination OF TRACE ALBUMIN USING UNLABELED EUROPIUM CHELATE
下载PDF
A QUENCHING FLUORESCENCE IMMUNOASSAY METHOD FOR DETERMINATION OF TRACE ALBUMIN USING UNLABELED TERBIUM CHELATE
5
作者 Feng Ji YAO Pei Hong LI Xiao Da YANG Bo XING Yun Xiang CI (Department of Chemistry,Peking University,100871) 《Chinese Chemical Letters》 SCIE CAS CSCD 1991年第9期737-738,共2页
A fluoroimmunoassay method using unlabeled Terbium chelate is described.The principle is similar to that of fluoroimmunoassay method using lanthanide chelate as labels.The procedure is simpte because labeling process ... A fluoroimmunoassay method using unlabeled Terbium chelate is described.The principle is similar to that of fluoroimmunoassay method using lanthanide chelate as labels.The procedure is simpte because labeling process is unnecessary.The recovery of HSA and albumin in urine is 107% and 95% respectively.The standard deviation is tess than 10%. 展开更多
关键词 FIA A QUENCHING fluorescence IMMUNOASSAY METHOD FOR determination OF TRACE ALBUMIN USING UNLABELED TERBIUM CHELATE
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部