期刊文献+
共找到11篇文章
< 1 >
每页显示 20 50 100
Improved Rotor Flux Observer for Sensorless Control of PMSM with Adaptive Harmonic Elimination and Phase Compensation 被引量:3
1
作者 Wei Xu Lei Wang +1 位作者 Yi Liu Frede Blaabjerg 《CES Transactions on Electrical Machines and Systems》 CSCD 2019年第2期151-159,共9页
In this paper,a sensorless control strategy of a permanent magnet synchronous machine(PMSM)based on an improved rotor flux observer(IFO)is proposed.Due to the unknown integral initial value and the high harmonics caus... In this paper,a sensorless control strategy of a permanent magnet synchronous machine(PMSM)based on an improved rotor flux observer(IFO)is proposed.Due to the unknown integral initial value and the high harmonics caused by current sampling and inverter nonlinearities,the flux linkage estimated by traditional rotor flux observer may be inaccurate.In order to address these issues,a self-adaptive band-pass filter(SABPF)is designed to eliminate the DC component and high-frequency harmonics of the estimated equivalent rotor flux linkage.Furthermore,in order to avoid that the design of PI parameter is influenced by the amplitude of equivalent rotor flux linkage,an improved phase-locked loop(IPLL)is employed to obtain the rotor speed and to normalize the estimated equivalent rotor flux linkage.In addition,angle shift caused by an SABPF is compensated to improve the accuracy of the estimated flux linkage angle.Besides,the parameter robustness of this method is analyzed in detail.Finally,simulation and experimental results demonstrate the effectiveness and parameter robustness of the proposed method. 展开更多
关键词 Improved phase-locked loop(IPLL) sensorless control improved flux observer(IFO) self-adaptive band-pass filter(SABPF).
下载PDF
NOVEL SENSORLESS VECTOR CONTROL SYSTEM OF INDUCTION MACHINE BASED ON FLUX OBSERVER IN FIELD WEAKENING 被引量:1
2
作者 邹积勇 许镇琳 孙凯 《Transactions of Tianjin University》 EI CAS 2006年第1期1-5,共5页
A speed-sensorless vector control system for induction machines (IMs)is presented, According to the vector control theory of IMs, the rotor flux is estimated based on a flux observer,and the speed is estimated throu... A speed-sensorless vector control system for induction machines (IMs)is presented, According to the vector control theory of IMs, the rotor flux is estimated based on a flux observer,and the speed is estimated through the method of q-axis rotor flux converging on zero with proportional integral regulator, A 0.75 kW,50 Hz,two-pole induction machine was used in the simulation and experimental verification, The simulation model was constructed in Matlab. A series of tests were performed in the field weakening region, for both no-load and loaded operation. The estimated speed tracks the actual speed well in the based speed region and field weakening region ( 1 per unit value to 4 per unit value). The small estimation error of residual speed is due to the existence of slip. 展开更多
关键词 induction machines (IMs) sensorless vector control flux observer speed estimation
下载PDF
An Improved Stator Flux Observation Method of Permanent Magnet Synchronous Motor 被引量:1
3
作者 Guangjing Su Hongmei Li +1 位作者 Ying Dai Zheng Li 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2016年第6期90-96,共7页
The stator flux and electromagnetic torque observation is the basis of direct torque controlled permanent magnet synchronous motor( PMSM) drive system. However,the traditional stator flux observer based on voltage mod... The stator flux and electromagnetic torque observation is the basis of direct torque controlled permanent magnet synchronous motor( PMSM) drive system. However,the traditional stator flux observer based on voltage model is affected by integral initial values and integral drift,that based on current model is affected by the parameters of PMSM,so a new stator flux observation method is proposed based on an improved secondorder generalized integrator( SOGI). Compared to the stator flux observation method based on the conventional SOGI,the proposed method can not only overcome the influence of integral initial values and integral drift,but also completely eliminate the DC offset's influence. Therefore,the observation accuracy of stator flux is further improved. The simulation and experimental results both show that the proposed method has a higher stator flux and electromagnetic torque observation precision. 展开更多
关键词 permanent magnet synchronous motor direct torque control second-order generalized integrator stator flux observation electromagnetic torque observation
下载PDF
Modified sensorless vector control system of IM based on flux observer
4
作者 邹积勇 许镇琳 孙凯 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2007年第6期880-883,共4页
This paper presents a speed sensorless vector control system for induction machine (IM),which is based on a flux observer. According to vector control theory of IM,the q-axis rotor flux converging on zero is utilized ... This paper presents a speed sensorless vector control system for induction machine (IM),which is based on a flux observer. According to vector control theory of IM,the q-axis rotor flux converging on zero is utilized for speed estimation. Additionally this system solved the online identification of stator resistance by d-axis flux error. The advantages of the proposed system are simplicity and avoidance of the problems caused by only using a voltage model. The effectiveness of the proposed system has been verified by simulation and experimentation. 展开更多
关键词 induction machine sensorless vector control flux observer speed estimation
下载PDF
A New Hybrid Model Rotor Flux Observer and Its Application
5
作者 ZHOU Yuan-shen 《Journal of China University of Mining and Technology》 2006年第1期71-76,共6页
A new hybrid model rotor flux observer, based on a new voltage model, is presented. In the first place, the voltage model of an induction machine was constructed by using the modeling method discussed in this paper an... A new hybrid model rotor flux observer, based on a new voltage model, is presented. In the first place, the voltage model of an induction machine was constructed by using the modeling method discussed in this paper and then the current model using a flux feedback was adopted in this flux observer. Secondly, the two models were com- bined via a filter and then the rotor flux observer was established. In the M-T synchronous coordinate, the observer was analyzed theoretically and several important functions were derived. A comparison between the observer and the traditional models was made using Matlab software. The simulation results show that the observer model had a better performance than the traditional model. 展开更多
关键词 new hybrid model rotor flux observer induction machine: cycloconverter
下载PDF
Observation Research of the Turbulent Fluxes of Momentum, Sensible Heat and Latent Heat over the West Pacific Tropical Ocean Area
6
作者 曲绍厚 《Advances in Atmospheric Sciences》 SCIE CAS CSCD 1989年第2期254-264,共11页
This paper describes results of the fluxes of momentum , sensible heat and latent heat for the West Pacific Tropical Ocean Area ( 127 ° E - 150 ° E , 5 ° N -3 ° S ). The data were collected by the ... This paper describes results of the fluxes of momentum , sensible heat and latent heat for the West Pacific Tropical Ocean Area ( 127 ° E - 150 ° E , 5 ° N -3 ° S ). The data were collected by the small tethered balloon sounding system over this ocean area including 6 continuous stations (140 ° E. 0 ° ; 145 ° E, 0 ° ; 150 ° E, 0 ° ; 140° E, 5 ° N; 145 ° E, 5° N and 150 ° E, 5 ° N) from 11 October to 15 December, 1986 . These fluxes were calculated by the semiempirical flux-profile relationships of Monin-Obukhov similarity theory using these observed data. The results show that for this tropical ocean area the drag coefficient CD is equal to (1.53 ± 0.25) × 10 3 and the daily mean latent flux Hl is greater than its daily mean sensible flux HV by a factor of about 9. 展开更多
关键词 heat Observation Research of the Turbulent fluxes of Momentum Sensible Heat and Latent Heat over the West Pacific Tropical Ocean Area OVER West
下载PDF
Research on Direct Torque Control System Based on Induction Motor
7
作者 康劲松 陶生桂 毛明平 《Journal of Shanghai Jiaotong university(Science)》 EI 2003年第2期157-162,共6页
The mathematic model of direct torque control (DTC) was deduced. Two simulating models based on the MATLAB & SIMULINK were established. The emphasis is focused on study of the performance difference of the DTC sys... The mathematic model of direct torque control (DTC) was deduced. Two simulating models based on the MATLAB & SIMULINK were established. The emphasis is focused on study of the performance difference of the DTC system with stator flux hexagon and circle trajectories. The simulation waveforms of flux, torque and current characters with two flux trajectories were given. Experiments were carried out in an AC drive system based on induction motor and two-level inverter. A dual-CPU structure was used and the communication with two CPUs was obtained by a dual-port RAM in this system. 展开更多
关键词 direct torque control (DTC) flux trajectory flux observing model dual-port RAM
下载PDF
Study on inverter fault-tolerant operation of PMSM DTC 被引量:1
8
作者 Yznaga Blanco IVONNE Dan SUN Yi-kang HE 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2008年第2期156-164,共9页
This paper presents an investigation of inverter fault-tolerant operation for a permanent magnet synchronous motor (PMSM) direct torque control (DTC) system under various inverter faults. The performance of a faul... This paper presents an investigation of inverter fault-tolerant operation for a permanent magnet synchronous motor (PMSM) direct torque control (DTC) system under various inverter faults. The performance of a faulty standard 6-switch inverter driven PMSM DTC system is analyzed. To avoid the loss or even disaster caused by the inverter faults, a topology-modified inverter with fault-tolerant capability is introduced, which is reconfigured as a 3-phase 4-switch inverter. The modeling of the 4-switch inverter is then analyzed and a novel DTC strategy with a unique nonlinear perpendicular flux observer and feedback compensation scheme is proposed for obtaining a continuous, disturbance-flee drive system. The simulation and experimental results demonstrate that the proposed inverter fault-tolerant PMSM DTC system is able to operate stably and continuously with acceptable static and pretty good dynamic performance. 展开更多
关键词 Permanent magnet synchronous motor (PMSM) Direct torque control (DTC) Fault-tolerant operation Four-switchinverter Nonlinear perpendicular flux observer
下载PDF
Recognizing the Scientific Mission of Flux Tower Observation Networks——Lay the Solid Scientific Data Foundation for Solving Ecological Issues Related to Global Change 被引量:10
9
作者 于贵瑞 陈智 +9 位作者 张雷明 彭长辉 陈镜明 朴世龙 张扬建 牛书丽 王秋凤 骆亦其 Philippe Ciais Dennis D.Baldocchi 《Journal of Resources and Ecology》 CSCD 2017年第2期115-120,共6页
As the Earth entering into the Anthropocene, global sustainable development requires ecological research to evolve into the large-scale, quantitative, and predictive era. It necessitates a revolution of ecological obs... As the Earth entering into the Anthropocene, global sustainable development requires ecological research to evolve into the large-scale, quantitative, and predictive era. It necessitates a revolution of ecological observation technology and a long-term accumulation of scientific data. The ecosystem flux tower observation technology is the right one to meet this requirement. However, the unique advantages and potential values of global-scale flux tower observation are still not fully appreciated. Reviewing the development history of global meteorological observation and its scientific contributions to the society, we can get an important enlightenment to re-cognize the scientific mission of flux observation. 展开更多
关键词 flux tower observation ecological research scientific data accumulation global sustainable development ecological prediction
原文传递
Sliding Mode Fault-tolerant Control Based on Fast Convergence Law for Faults of PMSM
10
作者 Wan Feng Mengdi Li +2 位作者 Wenjuan Zhang Shoudao Huang Haixia Zhang 《Chinese Journal of Electrical Engineering》 EI CSCD 2024年第3期147-157,共11页
It is difficult for the traditional PI controller to meet high-performance control requirements under the demagnetization fault of a permanent magnet synchronous motor(PMSM).To address this problem,this study proposes... It is difficult for the traditional PI controller to meet high-performance control requirements under the demagnetization fault of a permanent magnet synchronous motor(PMSM).To address this problem,this study proposes a novel sliding mode fault-tolerant control method for PMSM demagnetization faults.First,the mathematical model of PMSM under demagnetization fault state is established,and the reasons for poor fault tolerance of the conventional PI controller are analyzed.A new convergence law is used to design the speed loop sliding mode feedback controller,and its stability is demonstrated.Meanwhile,an adaptive forgetting factor recursive least squares(AFRLS)flux linkage observer is designed to keep the controller parameter values in line with the actual motor parameter values,to reduce the impact of demagnetization faults on motor control performance and achieve fault-tolerant control of demagnetization faults.Finally,simulation and experimental comparison with conventional PI control demonstrate that the proposed method is more robust and resistant to interference. 展开更多
关键词 Permanent magnet synchronous motor demagnetization faults sliding mode fault-tolerant control flux linkage observer
原文传递
New adaptive vector control methods for induction motors with simpler structure and better performance 被引量:1
11
作者 Kang-Zhi LIU Masashi YOKOO +1 位作者 Keiichiro KONDO Tadanao ZANMA 《Control Theory and Technology》 EI CSCD 2015年第2期173-183,共3页
This paper deals with the vector control, including both the direct vector control(DVC) and the indirect vector control(Id VC),of induction motors. It is well known that the estimation of rotor flux plays a fundamenta... This paper deals with the vector control, including both the direct vector control(DVC) and the indirect vector control(Id VC),of induction motors. It is well known that the estimation of rotor flux plays a fundamental role in the DVC and the estimation of rotor resistance is vital in the slip compensation of the Id VC. In these estimations, the precision is significantly affected by the motor resistances. Therefore, online estimation of motor resistances is indispensable in practice.For a fast estimation of motor resistances, it is necessary to slow down the convergence rate of the current estimate. On the other hand, for a fast estimation of the rotor flux, it is necessary to speed up its convergence rate. It is very difficult to realize such a trade-off in convergence rates in a full order observer.In this paper, we propose to decouple the current observer from the flux observer so as to realize independent convergence rates. Then, the resistance estimation algorithm is applied to both DVC and Id VC. In particular, in the application to Id VC the flux observer needs not be used, which leads to a simpler structure. Meanwhile, independent convergence rates of current observer and flux observer yield an improved performance. A superior performance in the torque and flux responses in both cases is verified by numerous simulations. 展开更多
关键词 Induction motor current observer flux observer parameter adaptation indirect vector control direct vector control
全文增补中
上一页 1 下一页 到第
使用帮助 返回顶部