To study the influence of slenderness on the axial compressive performance of autoclaved fly ash solid brick masonry columns, compression experiments were conducted on 12 samples of autoclaved fly ash solid brick maso...To study the influence of slenderness on the axial compressive performance of autoclaved fly ash solid brick masonry columns, compression experiments were conducted on 12 samples of autoclaved fly ash solid brick masonry column and 4 samples of fired clay brick masonry column. The damage patterns and compressive performance were compared and analyzed. The experimental results indicate that the compressive bearing capacity decreases as slenderness increases from 3 to 18, and the compressive bearing capacity of the autoclaved fly ash solid brick masonry columns is lower than that of the fired clay brick masonry columns. The formulae for the axial compressive bearing capacity of autoclaved fly ash solid brick masonry columns were derived based on the experiments. The nonlinear FEA program ANSYS was adopted to simulate the behaviors of masonry columns. By comparing the simulation results and experimental results, it is shown that the simulation results agree well with the experimental ones. The rationality and applicability of the simulation results were verified.展开更多
The reactivity of autoclaved materials is conventionally estimated by their chemical composition. In this paper, after determining the chemical composition of various types of fly ash, a series of new tests which incl...The reactivity of autoclaved materials is conventionally estimated by their chemical composition. In this paper, after determining the chemical composition of various types of fly ash, a series of new tests which included X-ray Diffraction (XRD), infrared spectral analysis (IR) and bound water testing, were applied to investigate the performance of autoclaved fly ash products. The relationship between the infrared spectral analysis of Si-O wavenumber (about 1 100 cm-1) and its autoclaved chemical reactivity, and compressive strength of its autoclaved samples, is analyzed. The results show that fly ash with a lower wavenumber will have stronger autoclaved chemical reactivity and higher compressive strength for its autoclaved sample. Thus, the Si-O stretching vibration wavelength can be used to estimate autoclaved chemical reactivity of fly ash, so as to control the quality of fly ash to be autoclaved, and to predict the compressive strength of autoclaved fly ash products.展开更多
This paper is aimed at verifying utilization possibilities of alkaline modified coal fly ash as cement replacement in the concrete. The influence of alkaline activated coal fly ash originating from Slovakian power pla...This paper is aimed at verifying utilization possibilities of alkaline modified coal fly ash as cement replacement in the concrete. The influence of alkaline activated coal fly ash originating from Slovakian power plant in Novsky (Si/Al = 3,1) as a partial cement replacement in concrete on compressive strength of hardened composites after 28 and 90 days was investigated. Alkaline activation of coal fly ash was realized in an autoclave at 130 ℃ and pressure of 160 kPa during 5 hours and in a reactor under normal conditions (equal temperature during 36 hours) at solid/liquid ratio of 0.5. Coal fly ash/cement mixtures were prepared with 25 % cement replacement by starting and modified coal fly ash and given in forms. Compressive strengths of composites after 28 and 90 days of hardening were compared to referential composite without coal fly ash and evaluated according to the standard of STN EN 450 by the value of relative strength KR (compressive strength of coal fly ash/cement composite to compressive strength of comparative concrete). The final compressive strengths of hardened composites based on alkaline activated coal fly ash reached values in the range of 6 up to 50 MPa. In the set of experimental composites based on alkaline activated coal fly ashes, the highest value of relative strength after 28- and 90- days of hardening reached composite with cement replacement by coal fly ash zeolitized in autoclave (105% of compressive strength of referential sample), what is connected with formation of zeolitic phases on surface of coal fly ash particles. The achieved results confirm that alkaline activation of coal fly ash in an autoclave under observed conditions can be successfully used as a partial cement replacement in concrete of C20/25 and C25/30 in accordance with requirements of standards (STN EN 450 and STN EN 206).展开更多
基金Supported by National Key Technology Research and Development Program (No.2008BAJ08B11-03)
文摘To study the influence of slenderness on the axial compressive performance of autoclaved fly ash solid brick masonry columns, compression experiments were conducted on 12 samples of autoclaved fly ash solid brick masonry column and 4 samples of fired clay brick masonry column. The damage patterns and compressive performance were compared and analyzed. The experimental results indicate that the compressive bearing capacity decreases as slenderness increases from 3 to 18, and the compressive bearing capacity of the autoclaved fly ash solid brick masonry columns is lower than that of the fired clay brick masonry columns. The formulae for the axial compressive bearing capacity of autoclaved fly ash solid brick masonry columns were derived based on the experiments. The nonlinear FEA program ANSYS was adopted to simulate the behaviors of masonry columns. By comparing the simulation results and experimental results, it is shown that the simulation results agree well with the experimental ones. The rationality and applicability of the simulation results were verified.
文摘The reactivity of autoclaved materials is conventionally estimated by their chemical composition. In this paper, after determining the chemical composition of various types of fly ash, a series of new tests which included X-ray Diffraction (XRD), infrared spectral analysis (IR) and bound water testing, were applied to investigate the performance of autoclaved fly ash products. The relationship between the infrared spectral analysis of Si-O wavenumber (about 1 100 cm-1) and its autoclaved chemical reactivity, and compressive strength of its autoclaved samples, is analyzed. The results show that fly ash with a lower wavenumber will have stronger autoclaved chemical reactivity and higher compressive strength for its autoclaved sample. Thus, the Si-O stretching vibration wavelength can be used to estimate autoclaved chemical reactivity of fly ash, so as to control the quality of fly ash to be autoclaved, and to predict the compressive strength of autoclaved fly ash products.
文摘This paper is aimed at verifying utilization possibilities of alkaline modified coal fly ash as cement replacement in the concrete. The influence of alkaline activated coal fly ash originating from Slovakian power plant in Novsky (Si/Al = 3,1) as a partial cement replacement in concrete on compressive strength of hardened composites after 28 and 90 days was investigated. Alkaline activation of coal fly ash was realized in an autoclave at 130 ℃ and pressure of 160 kPa during 5 hours and in a reactor under normal conditions (equal temperature during 36 hours) at solid/liquid ratio of 0.5. Coal fly ash/cement mixtures were prepared with 25 % cement replacement by starting and modified coal fly ash and given in forms. Compressive strengths of composites after 28 and 90 days of hardening were compared to referential composite without coal fly ash and evaluated according to the standard of STN EN 450 by the value of relative strength KR (compressive strength of coal fly ash/cement composite to compressive strength of comparative concrete). The final compressive strengths of hardened composites based on alkaline activated coal fly ash reached values in the range of 6 up to 50 MPa. In the set of experimental composites based on alkaline activated coal fly ashes, the highest value of relative strength after 28- and 90- days of hardening reached composite with cement replacement by coal fly ash zeolitized in autoclave (105% of compressive strength of referential sample), what is connected with formation of zeolitic phases on surface of coal fly ash particles. The achieved results confirm that alkaline activation of coal fly ash in an autoclave under observed conditions can be successfully used as a partial cement replacement in concrete of C20/25 and C25/30 in accordance with requirements of standards (STN EN 450 and STN EN 206).