Root-mean-square distance Drms with characteristic of weighted-average is introduced in this article firstly. Drms can be used to capture the general proximity of a site to a dipping fault plane comparing with the rup...Root-mean-square distance Drms with characteristic of weighted-average is introduced in this article firstly. Drms can be used to capture the general proximity of a site to a dipping fault plane comparing with the rupture distance Drup and the seismogenic distance Dseis. Then, using Drup, Dseis and Drms, the hanging wall/footwall effects on the peak ground acceleration (PGA) during the 1999 Chi-Chi earthquake are evaluated by regression analysis. The logarithm residual shows that the PGA on hanging wall is much greater than that on footwall at the same Drup or Dseis when the Drup or Dseis is used as site-to-source distance measure. In contrast, there is no significant difference between the PGA on hanging wall and that on footwall at the same Drms when Drms is used. This result confirms that the hanging wall/footwall effect is mainly a geometric effect caused by the asymmetry of dipping fault. Therefore, the hanging wall/footwall effect on the near-fault ground motions can be ignored in the future attenuation analysis if the root-mean-square distance Drms is used as the site-to-source distance measure.展开更多
Systematic differences in the duration and frequency content of ground motions from the hanging wall and footwall during the 2008 Wenchuan earthquake are investigated,focusing on the influence of these differences on ...Systematic differences in the duration and frequency content of ground motions from the hanging wall and footwall during the 2008 Wenchuan earthquake are investigated,focusing on the influence of these differences on structural input energy based on the elastic and inelastic energy responses of structures.A comparison of the input energy spectra between the hanging wall and the footwall reveal that the structural input energy on the hanging wall is not amplified due to the short duration and low peak ground velocity to acceleration ratio(V/A).However,the larger demand of structural input energy on the footwall in the range of medium and long periods is observed and the demand increases up to 50% relative to the average level of structural input energy for rupture distances larger than 30 km.The importance of considering the footwall effect on structural input energy when comparing ground motions in the range of medium and long periods is recognized.展开更多
基金Basic Science Research Foundation of Institute of Engineering Mechanics, China Earthquake Administration (2006B07) Natural Science Foundation of Heilongjiang Province (E2007-13)Joint Seismological Science Foundation of China (C07025)
文摘Root-mean-square distance Drms with characteristic of weighted-average is introduced in this article firstly. Drms can be used to capture the general proximity of a site to a dipping fault plane comparing with the rupture distance Drup and the seismogenic distance Dseis. Then, using Drup, Dseis and Drms, the hanging wall/footwall effects on the peak ground acceleration (PGA) during the 1999 Chi-Chi earthquake are evaluated by regression analysis. The logarithm residual shows that the PGA on hanging wall is much greater than that on footwall at the same Drup or Dseis when the Drup or Dseis is used as site-to-source distance measure. In contrast, there is no significant difference between the PGA on hanging wall and that on footwall at the same Drms when Drms is used. This result confirms that the hanging wall/footwall effect is mainly a geometric effect caused by the asymmetry of dipping fault. Therefore, the hanging wall/footwall effect on the near-fault ground motions can be ignored in the future attenuation analysis if the root-mean-square distance Drms is used as the site-to-source distance measure.
基金Special Research Foundation of Earthquake Industry under Grant No. 201208013National Natural Science Foundation of China under Grant No. 51008101 & 51078117
文摘Systematic differences in the duration and frequency content of ground motions from the hanging wall and footwall during the 2008 Wenchuan earthquake are investigated,focusing on the influence of these differences on structural input energy based on the elastic and inelastic energy responses of structures.A comparison of the input energy spectra between the hanging wall and the footwall reveal that the structural input energy on the hanging wall is not amplified due to the short duration and low peak ground velocity to acceleration ratio(V/A).However,the larger demand of structural input energy on the footwall in the range of medium and long periods is observed and the demand increases up to 50% relative to the average level of structural input energy for rupture distances larger than 30 km.The importance of considering the footwall effect on structural input energy when comparing ground motions in the range of medium and long periods is recognized.