In slab column-shear wall structures,both the whole structure′s seismic behavior and failure mode are greatly influenced by the distribution of horizontal seismic forces between slab-column and shear wall.In this pap...In slab column-shear wall structures,both the whole structure′s seismic behavior and failure mode are greatly influenced by the distribution of horizontal seismic forces between slab-column and shear wall.In this paper,a pushover analysis of topical slab column-shear wall structure was carried out,the seismic shear force that the slab-column and shear wall should undertake was worked out,the influences of plastic internal force redistribution and structure stiffness characteristic value on horizontal seismic distribution were studied and the calculation formula was given.The analysis results showed that with the yield of the shear walls,the story shear force was undertaken by slab-columns correspondingly increased while with the decrease of characteristic value of stiffness of a structure,and the horizontal seismic force was undertaken by slab-columns correspondingly decreased.According to the code,the design of horizontal force distribution may be cause insecurity problems,so it is necessary to give the distribution law of horizontal seismic forces in slab-column shear wall structures as the supplement to the corresponding regulation of the Code.展开更多
In the case of composite girders, an effective cooperation of both parts of the section is influenced by deformability of connectors. Limited flexural stiffness of welded studs, used commonly in bridge structures, doe...In the case of composite girders, an effective cooperation of both parts of the section is influenced by deformability of connectors. Limited flexural stiffness of welded studs, used commonly in bridge structures, does not provide full interaction of a steel beam and a concrete slab. This changes strain distribution in cross-sections of a composite girder and results in redistribution of internal forces in steel and concrete element. In the paper partial interaction index defined on the basis of a neutral axis position, which can be used for verification of steel-concrete interaction in real bridge structures rather than in specimens is proposed. The range of the index value changes, obtained during load testing of a typical steel-concrete composite beam bridge, is presented. The investigation was carried out on a motorway viaduct, consisting of two parallel structures. During the testing values of strains in girders under static and quasi-static loads were measured. The readings from the gauges were used to determine the index, characterizing composite action of the girders. Results of bridge testing under movable load, changing position along the bridge span is presented and obtained in-situ influence functions of strains and index values are commented in the paper.展开更多
文摘In slab column-shear wall structures,both the whole structure′s seismic behavior and failure mode are greatly influenced by the distribution of horizontal seismic forces between slab-column and shear wall.In this paper,a pushover analysis of topical slab column-shear wall structure was carried out,the seismic shear force that the slab-column and shear wall should undertake was worked out,the influences of plastic internal force redistribution and structure stiffness characteristic value on horizontal seismic distribution were studied and the calculation formula was given.The analysis results showed that with the yield of the shear walls,the story shear force was undertaken by slab-columns correspondingly increased while with the decrease of characteristic value of stiffness of a structure,and the horizontal seismic force was undertaken by slab-columns correspondingly decreased.According to the code,the design of horizontal force distribution may be cause insecurity problems,so it is necessary to give the distribution law of horizontal seismic forces in slab-column shear wall structures as the supplement to the corresponding regulation of the Code.
文摘In the case of composite girders, an effective cooperation of both parts of the section is influenced by deformability of connectors. Limited flexural stiffness of welded studs, used commonly in bridge structures, does not provide full interaction of a steel beam and a concrete slab. This changes strain distribution in cross-sections of a composite girder and results in redistribution of internal forces in steel and concrete element. In the paper partial interaction index defined on the basis of a neutral axis position, which can be used for verification of steel-concrete interaction in real bridge structures rather than in specimens is proposed. The range of the index value changes, obtained during load testing of a typical steel-concrete composite beam bridge, is presented. The investigation was carried out on a motorway viaduct, consisting of two parallel structures. During the testing values of strains in girders under static and quasi-static loads were measured. The readings from the gauges were used to determine the index, characterizing composite action of the girders. Results of bridge testing under movable load, changing position along the bridge span is presented and obtained in-situ influence functions of strains and index values are commented in the paper.