期刊文献+
共找到142篇文章
< 1 2 8 >
每页显示 20 50 100
Foreign metallic pellet in the heart
1
作者 安永 肖颖彬 钟前进 《Chinese Journal of Traumatology》 CAS 2007年第5期318-320,共3页
Foreign bodies in the heart are a rare but serious form of cardiac injury. The objects usually are sharp pointed. Such as acupuncture needles,sewing needles, coat hangers, fragments of Kirschner wires, pins, etc. 1 We... Foreign bodies in the heart are a rare but serious form of cardiac injury. The objects usually are sharp pointed. Such as acupuncture needles,sewing needles, coat hangers, fragments of Kirschner wires, pins, etc. 1 We report a patient with a metallic pellet lodged in the heart, which was accurately diagnosed and successfully removed. 展开更多
关键词 foreign metallic pellet in the heart 拜一 BODY
原文传递
Strengthening——Foreign Scientific Cooperation in the Non-ferrous Metal Industry
2
作者 Zhong He 《China's Foreign Trade》 1997年第9期20-20,共1页
Since the China Non-Ferrous Metal Industry Corporation was founded, it has always adhered to the development principle of "Science and technology are a production force" and "Economic construction must ... Since the China Non-Ferrous Metal Industry Corporation was founded, it has always adhered to the development principle of "Science and technology are a production force" and "Economic construction must rely on science and technology progress and science and technology must serve economic construction in return" to enhance the reform in the scientific research system. With support from the State and 展开更多
关键词 foreign Scientific Cooperation in the Non-ferrous metal Industry Strengthening MUST
下载PDF
The Tissue Reactions and Changes of a Surface of Various Metal Implants after Their Introduction in a Bone Tissue in Experiment
3
作者 Michael S. Toder Andrew I. Shevela +3 位作者 Alexander A. Shevela Paul A. Zheleznyi Anna P. Zheleznaia Igor V. Mayborodin 《Surgical Science》 2016年第2期100-106,共7页
Screw metal implants (3S, Israel) with rough or smooth polished surface were introduced in a tibial proximal condyle of not purebred rabbits. The condition of surrounding tissues in 2 and 6 months after implantation w... Screw metal implants (3S, Israel) with rough or smooth polished surface were introduced in a tibial proximal condyle of not purebred rabbits. The condition of surrounding tissues in 2 and 6 months after implantation was compared by light microscopy and X-ray methods. Within 6 months after operation the considerable distinctions of radiological and morphological data were revealed not. 2 months later after introduction of implants with a rough surface the effort enclosed for its twisting is, much more, than for removal of the polished product. However, stability of fixing of implants was practically made even at 6 months. On remote rough implants there is a set of tissue scraps whereas on products with a smooth surface the tissue remains were much less. Surrounding tissues strongly join a rough surface, grow into cavities, and during removal of such products there is a considerable trauma of tissues round an implantation place. Smooth implants have the smaller area of contact with organism tissues, they are fixed due to bicortical implantation, during removal easily get out and don’t break off surrounding tissues. The signs of inflammation and formation of merged multinuclear macrophages were not found at all cases, which give evidence to the inertness of material of the mentioned articles for living organism. In some observations however and by implantation of the rough article and by introduction of polished implants, metal particles were found, but after use of the foreign body with grit-blasted treatment of surface metal was found more frequently, and its fragments had larger volume. 展开更多
关键词 Implantation of metals Intra Bone Durability of Implant Fixing Isolation of foreign Bodies metal Fragments in Tissues Features of Implant Removal
下载PDF
未发现眼内金属异物的外伤性白内障病例1例报告
4
作者 王晶 李春丽 +3 位作者 叶强 王浩 律鹏 张文芳 《实用临床医药杂志》 CAS 2024年第11期107-109,共3页
外伤性白内障在临床中较常见,通常非金属异物进入眼内,患者无眼内反应,只表现为外伤性白内障,而金属异物进入眼内易引起并发症。异物进入眼内可通过眼科检查发现,或行白内障手术找到异物。然而,临床中极少部分患者会出现漏诊。本文报告... 外伤性白内障在临床中较常见,通常非金属异物进入眼内,患者无眼内反应,只表现为外伤性白内障,而金属异物进入眼内易引起并发症。异物进入眼内可通过眼科检查发现,或行白内障手术找到异物。然而,临床中极少部分患者会出现漏诊。本文报告1例眼内金属异物消失的外伤性白内障病例(有眼部外伤异物进入眼内病史以及体征,但术前、术中、术后均未发现异物),并分析金属异物消失的原因。 展开更多
关键词 外伤性白内障 金属异物 病例报告 眼内反应
下载PDF
丙烯酸-壳聚糖凝胶负载废酵母处理重金属离子 被引量:1
5
作者 王霏 李升军 +4 位作者 崔荣煜 吴金秋 楚飞虎 曹丰 冯芳 《环境科学与技术》 CAS CSCD 北大核心 2024年第4期62-70,共9页
目前,重金属废水处理技术研究中采用的生物吸附剂大多呈粉体状,会因活性结构特性不易保持,并且固液分离损失大、能耗高,导致其在重金属废水处理工程化应用受到制约。文章以丙烯酸和壳聚糖为原料,通过紫外交联法制备块体凝胶并负载废酵... 目前,重金属废水处理技术研究中采用的生物吸附剂大多呈粉体状,会因活性结构特性不易保持,并且固液分离损失大、能耗高,导致其在重金属废水处理工程化应用受到制约。文章以丙烯酸和壳聚糖为原料,通过紫外交联法制备块体凝胶并负载废酵母作为生物吸附剂。研究紫外交联丙烯酸复合壳聚糖制成凝胶的优化条件,当丙烯酸与壳聚糖的比值为30∶1,加入15%质量百分比的N-N亚甲基双丙烯酰胺作为交联剂,再加入2%质量百分比的1173D作为光引发剂,此时制备出的含废酵母丙烯酸复合壳聚糖基水凝胶具有较好的溶胀性能和孔洞结构,对于Zn、Cd或Pb离子吸附去除率分别为27.8%、30.8%和38.8%。凝胶包埋废酵母后,去除水中低浓度的重金属Zn、Cd和Pb离子均有提升,对Pb^(2+)溶液的综合吸附去除率达到74.8%。丙烯酸-壳聚糖凝胶作为生物吸附剂载体实现简易快速包埋成型,块体形状有利于后续载体回收。 展开更多
关键词 生物吸附 废酵母 丙烯酸 壳聚糖 紫外交联 凝胶 重金属废水
下载PDF
金属异物缺陷演化特性及其对产线K值的影响机制
6
作者 袁悦博 王贺武 +4 位作者 孔祥栋 蒲明伟 孙玉坤 韩雪冰 欧阳明高 《储能科学与技术》 CAS CSCD 北大核心 2024年第4期1197-1204,共8页
电池制造过程出现的缺陷问题会极大影响电池产品的安全性等,其中产线金属异物侵入可能导致自发性内短路甚至引发热失控,然而目前关于在电池内部的演化机理及相应的外在表征的研究较少,尤其是针对微小金属异物的研究。因此本研究在电池... 电池制造过程出现的缺陷问题会极大影响电池产品的安全性等,其中产线金属异物侵入可能导致自发性内短路甚至引发热失控,然而目前关于在电池内部的演化机理及相应的外在表征的研究较少,尤其是针对微小金属异物的研究。因此本研究在电池中植入百微米直径铜颗粒,模拟产线金属异物侵入形成缺陷电池,分析了缺陷电池内短路电流特征,拆解研究了内短路区域的微观结构,通过模型仿真了内短路区域的电位分布,综合解释了缺陷对产线关键检测指标K值(电压下降率)的影响规律与机制,并在实际试制线大容量电池上进行了验证。相关研究成果可用于提高产线缺陷检出率,预防潜在的安全事故。研究结果表明,铜颗粒等金属异物侵入电池后,可能导致正极-颗粒-负极和正极-负极两种模式的内短路,内短路电流在正极中产生的电位梯度可抑制颗粒的进一步溶解,从而使得在K值测试条件下的两种内短路模式均会达到平衡状态。两种模式的内短路程度相近,内短路电流处在0.1~1 mA量级。相同的内短路电流对于不同容量单体的K值影响不同,产线上为保证检测效果,随着电池产品容量的增加,K值检测阈值及正常电池的基准值需要相应降低。 展开更多
关键词 锂离子电池 智能制造 金属异物 缺陷检测 K值
下载PDF
无线功率发射器的安规符合性要求
7
作者 倪晶 夏志琴 +2 位作者 庞佳 李伟 邹扬燕 《日用电器》 2024年第8期126-129,共4页
GB 4943.1-2022《音视频、信息技术和通信技术设备第1部分:安全要求》于2022年7月19日发布并在2023年8月1号正式实施,同时取代GB 4943.1-2011和GB 8898-2011标准。新标准对无线功率发射器提出了全新的要求;本文通过对比GB 4943.1-2022、... GB 4943.1-2022《音视频、信息技术和通信技术设备第1部分:安全要求》于2022年7月19日发布并在2023年8月1号正式实施,同时取代GB 4943.1-2011和GB 8898-2011标准。新标准对无线功率发射器提出了全新的要求;本文通过对比GB 4943.1-2022、IEC 62368-1:2018和IEC 62368-1:2023的不同标准差异,以及根据《全国电子产品安全标准化技术委员会决议第010号》决议,明确最新标准GB 4943.1-2022中§9.6无线功率发射器的要求的测试方法以及合格判定依据。 展开更多
关键词 无线功率发射器 金属异物 热灼伤
下载PDF
Dental Precautions for the Golden Thread Lift Procedure
8
作者 Toshiyuki Inou Keiko Kaneko +8 位作者 Tatsuo Takaya Toshinobu Tsumura Emi Oki Yu Chi Hung Takuya Iwasaki Toru Kageyama Zeng Bo Zhao Yoshimi Kawahara Keiichi Uchida 《Open Journal of Stomatology》 2024年第11期433-439,共7页
In cosmetic surgery, golden threads have been used in thread lift procedures, wherein golden threads are placed under the skin of the neck and chin. These are mainly applied in the maxillofacial region adjacent to the... In cosmetic surgery, golden threads have been used in thread lift procedures, wherein golden threads are placed under the skin of the neck and chin. These are mainly applied in the maxillofacial region adjacent to the sites of dental treatment to achieve cosmetic benefits. However, as dentists typically lack sufficient knowledge about the golden thread lift procedure, it may present a challenge to dental examinations and treatments. It is therefore crucial for dentists to have a comprehensive understanding of the procedure. This case report covers our experience with the dental examination of a patient with golden threads. We emphasize the dental complications and precautions that should be taken for such cases. These golden threads are made of pure gold, nonabsorbable, and can be broken. These can obstruct dental examination, as well as cause metal allergies and foreign body granulomas. Additionally, it is difficult to completely remove these threads when they break apart. In the future, since more patients are expected to undergo this procedure, it is possible to encounter these golden threads as artifacts on imaging. Therefore, it is important to educate dentists about the golden thread lift procedure and its dental implications. It is also imperative to determine whether the patient has undergone the golden thread lift procedure in the medical questionnaire prior to the magnetic resonance imaging examination. Thus, dentists should be able to conduct a detailed interview with the patient, determine the feasibility of examination or treatment, and communicate this assessment to the patient. 展开更多
关键词 Golden Threads Computed Tomography Magnetic Resonance Imaging metal Allergy foreign Body Granuloma
下载PDF
一起550kV HGIS气室闪络故障分析 被引量:7
9
作者 陈伟民 周海滨 +1 位作者 张长虹 张新波 《高压电器》 CAS CSCD 北大核心 2016年第2期185-190,共6页
针对某站2号母线发生的故障跳闸进行多维度分析,开展了交流场靠2号母线侧开关气室的SF6气体的分解产物和湿度测试,数据表明50532开关C相存在异常。随后对其进行了开盖检查,发现内部导管对套管法兰处发生了严重的电弧放电。结合后续的返... 针对某站2号母线发生的故障跳闸进行多维度分析,开展了交流场靠2号母线侧开关气室的SF6气体的分解产物和湿度测试,数据表明50532开关C相存在异常。随后对其进行了开盖检查,发现内部导管对套管法兰处发生了严重的电弧放电。结合后续的返厂解体情况,对故障的原因进行了故障树分析,并借助成分分析等技术推断,50532开关C相气室故障是由于现场组装阶段混入并黏着在导管的7 mm左右金属异物,在运行3个月后受震动影响,从低电场区域掉落强电场区域,导致了闪络故障的发生。 展开更多
关键词 HGIS 闪络 解体 故障树 成分分析 金属异物
下载PDF
某高速铁路钢轨踏面伤损原因分析 被引量:6
10
作者 李闯 刘丰收 +3 位作者 俞喆 梁旭 张银花 周清跃 《理化检验(物理分册)》 CAS 2015年第12期894-897,共4页
某高速铁路钢轨踏面存在多处凹坑。采用宏观观察、扫描电镜及能谱分析、金相检验、硬度测试等方法,对钢轨伤损的原因进行了分析。结果表明:钢轨踏面凹坑是由于列车运行中金属异物压入所致;异物镶嵌在动车组车轮踏面上,随车轮转动对钢轨... 某高速铁路钢轨踏面存在多处凹坑。采用宏观观察、扫描电镜及能谱分析、金相检验、硬度测试等方法,对钢轨伤损的原因进行了分析。结果表明:钢轨踏面凹坑是由于列车运行中金属异物压入所致;异物镶嵌在动车组车轮踏面上,随车轮转动对钢轨造成连续碾压,形成一系列凹坑;由于异物硬度远高于钢轨基体,因此异物压入后钢轨基体组织产生严重塑性变形和微裂纹。 展开更多
关键词 高速铁路 钢轨踏面 凹坑 伤损 金属异物压入
下载PDF
金属异物对电动汽车无线充电系统影响分析 被引量:31
11
作者 马中原 廖承林 王丽芳 《电工电能新技术》 CSCD 北大核心 2017年第2期14-20,共7页
针对电动汽车在无线充电过程中可能混入金属异物的情况,本文分析了金属异物置于无线充电系统能量传输区域时对无线充电系统参数及效率的影响情况。研究中使用有限元仿真软件建立了电动汽车无线充电系统平面盘式螺旋线圈3D电磁场仿真模型... 针对电动汽车在无线充电过程中可能混入金属异物的情况,本文分析了金属异物置于无线充电系统能量传输区域时对无线充电系统参数及效率的影响情况。研究中使用有限元仿真软件建立了电动汽车无线充电系统平面盘式螺旋线圈3D电磁场仿真模型,通过理论分析和有限元仿真结合的方式研究了不同尺寸、不同材质的金属异物对无线能量传输系统的电磁场参数以及效率的影响,并进行了实验验证。研究结果表明,两种金属混入系统会产生涡流效应和磁效应,磁效应和涡流效应会对无线充电系统参数产生不同的影响,降低系统效率;其影响大小与金属的尺寸和位置密切相关;此外,金属的涡流效应会产生涡流损耗并导致温升,对充电系统是极大的安全隐患。 展开更多
关键词 电动汽车 无线充电 金属异物 有限元仿真
下载PDF
超声生物显微镜在非金属巩膜异物诊断中的应用 被引量:7
12
作者 沈蕾 吴尚操 +2 位作者 朱斌 陈婷 曾庆延 《国际眼科杂志》 CAS 2013年第4期804-806,共3页
目的:探讨超声生物显微镜在非金属巩膜异物诊断中的作用及应用。方法:回顾性分析我院2009-01/2012-11收治的有反复发作的局部眼红眼痛的症状及体征的非金属球壁异物患者15例15眼,全部为非急性期。进行数字化裂隙灯眼表照相,经过UBM检查... 目的:探讨超声生物显微镜在非金属巩膜异物诊断中的作用及应用。方法:回顾性分析我院2009-01/2012-11收治的有反复发作的局部眼红眼痛的症状及体征的非金属球壁异物患者15例15眼,全部为非急性期。进行数字化裂隙灯眼表照相,经过UBM检查确诊为巩膜异物,手术后证实为非金属异物。结果:有明确的植物眼外伤史10例10眼,病史不详5例5眼。病程1~6mo,均表现局部反复出现的眼红眼痛,药物治疗好转,停药后再次发作。裂隙灯下见局部的隆起,轻或重的充血,角膜无水肿。UBM检查见结膜下巩膜有高密度影,其后组织不显影声影,诊断:巩膜可疑异物。术后取出异物,11例11眼为植物异物,2例2眼为煤渣样异物,1例1眼为玻璃异物,1例1眼为石子异物。结论:超声生物显微镜能及时、尽早发现非金属巩膜异物,减少误诊。针对巩膜长期局部反复充血的患者,无论有无外伤史,均应应用UBM检查有否巩膜异物的存在。 展开更多
关键词 超声生物显微镜 非金属巩膜异物 诊断
下载PDF
电磁铁辅助磁性金属异物取出术28例体会 被引量:3
13
作者 袁翠华 王旭 刘寿坤 《中国骨伤》 CAS 2010年第1期15-16,共2页
磁性微细金属异物在骨科急诊、门诊诊治中经常遇到。这些患者大多要求行金属异物取出术。微细金属异物存留体内多为爆炸伤、机器压榨伤、铁砂枪弹伤、肌肉注射针头折断所致。有些外科医生低估了手术的难度程度,往往以失败而告终。2004... 磁性微细金属异物在骨科急诊、门诊诊治中经常遇到。这些患者大多要求行金属异物取出术。微细金属异物存留体内多为爆炸伤、机器压榨伤、铁砂枪弹伤、肌肉注射针头折断所致。有些外科医生低估了手术的难度程度,往往以失败而告终。2004年7月至2009年4月进行电磁铁辅助下磁性细金属异物取出术28例, 展开更多
关键词 异物 金属 电磁铁 外科手术
下载PDF
高频超声检查在颌面部非金属异物中的应用价值 被引量:7
14
作者 郭军 孟庆江 +2 位作者 白振西 张浚睿 封兴华 《口腔颌面外科杂志》 CAS 2004年第2期133-135,共3页
目的 探讨超声在颌面部非金属异物定位诊断中的价值和引导手术的意义。方法 采用高频超声对颌面部 33例患者 7种非金属异物的声像图特征及探查定位情况进行总结分析 ,并与手术后结果进行对照。结果  33例患者颌面部非金属异物共 5 2... 目的 探讨超声在颌面部非金属异物定位诊断中的价值和引导手术的意义。方法 采用高频超声对颌面部 33例患者 7种非金属异物的声像图特征及探查定位情况进行总结分析 ,并与手术后结果进行对照。结果  33例患者颌面部非金属异物共 5 2块 ,超声明确诊断并清晰定位 4 7块 ,定位诊断准确率 90 .4 %。对翼颌间隙、眶内及上颌后区的异物 ,超声诊断准确率受到一定的限制 ,5块诊断不准确。术前超声引导穿刺针定位或美兰标记异物 9块 ,手术顺利取出 9块 ;术中超声定位异物 11块 ,引导手术顺利取出 11块 ;超声引导手术成功率 10 0 %。结论 超声对软组织非金属异物图像显示清晰 ,定位准确 ,引导手术方便有效 ,对临床治疗和制定手术方案具有重要的指导意义。对翼颌间隙。 展开更多
关键词 高频超声检查 颌面部 非金属异物 引导手术 翼颌间隙
下载PDF
螺旋CT图像后处理技术诊断小儿气管、支气管非金属异物的价值 被引量:21
15
作者 郭少华 钟福兴 +4 位作者 廖志 刘少强 黄渺新 李荣芳 吴颋 《中国医学影像学杂志》 CSCD 2005年第5期371-374,共4页
目的评价螺旋CT图像后处理技术诊断小儿气管、支气管非金属异物的价值。材料和方法109例气管、支气管非金属异物患儿,经螺旋CT扫描后分别进行多平面重建(MPR)、CT仿真内窥镜(CTVE)、表面遮盖显示(SSD)和最小密度投影(MinP)4种图像后处... 目的评价螺旋CT图像后处理技术诊断小儿气管、支气管非金属异物的价值。材料和方法109例气管、支气管非金属异物患儿,经螺旋CT扫描后分别进行多平面重建(MPR)、CT仿真内窥镜(CTVE)、表面遮盖显示(SSD)和最小密度投影(MinP)4种图像后处理成像技术,并根椐诊断行小儿支气管内窥镜异物摘取术。结果术中取出气管异物27例、右侧支气管异物53例、左侧支气管异物18例、双侧支气管异物1例、气管并左侧支气管异物2例、气管并双侧支气管异物2例;另有3例未见明确异物,1例异物位于Ⅲ级支气管无法取出,1例由于喉头水肿纤维支气管镜无法通过并手术,1例术前突然窒息死亡。螺旋CT4种图像后处理技术对异物的显示率分别为MPR97.2%、CTVE94.4%、SSD83.2%、MinP70.1%。结论螺旋CT图像后处理技术结合原始轴位像对小儿气管、支气管非金属异物诊断迅速、准确,具有重要的诊断价值。 展开更多
关键词 气管 支气管 非金属异物 螺旋CT 图像后处理技术
下载PDF
介入法取出胃内金属异物30例 被引量:1
16
作者 贺祥 张和平 +6 位作者 任学群 靳海英 张杰 王长福 王晓宏 李长坡 袁天华 《介入放射学杂志》 CSCD 北大核心 2013年第4期328-330,共3页
目的探讨介入治疗胃内金属异物的方法、安全性和疗效。方法 30例胃内金属异物患者,均有经口金属异物吞入史。临床表现有上腹部疼痛不适、纳差、消化不良,精神抑郁,粪便潜血实验阳性。30例患者接受介入治疗,观察患者的医疗费用、手术时... 目的探讨介入治疗胃内金属异物的方法、安全性和疗效。方法 30例胃内金属异物患者,均有经口金属异物吞入史。临床表现有上腹部疼痛不适、纳差、消化不良,精神抑郁,粪便潜血实验阳性。30例患者接受介入治疗,观察患者的医疗费用、手术时间、疗效及并发症。结果 30例患者共32件胃内金属异物经自行制作的圈套器全部安全取出,未出现食管及胃黏膜损伤、出血及其他并发症。结论介入法取胃内金属异物具有操作简便、创伤小、安全性高、费用低、效果好、并发症少等优点,门诊治疗,不需住院,患者易于接受,是治疗胃内金属异物的理想方法。 展开更多
关键词 胃疾病 异物 金属 放射学 介入性
下载PDF
大型汽轮发电机定子遗留金属异物故障的特征分析 被引量:8
17
作者 冯复生 《电网技术》 EI CSCD 北大核心 2000年第8期23-26,共4页
分析了国产大型汽轮发电机近年来因制造、安装及检修中遗留金属异物而造成严重故障的基本特征 ,提出了防范措施 ,并利用专门的交变磁场对 11种不同形状及性质的常见金属体做了模拟试验 。
关键词 汽轮发电机 定子 金属异物 故障特征 大型发电机
下载PDF
无线电能传输系统异物检测技术研究综述 被引量:13
18
作者 张献 邢子瑶 +2 位作者 薛明 杨庆新 孙于 《电工技术学报》 EI CSCD 北大核心 2022年第4期793-807,共15页
近几年,无线电能传输技术发展迅猛,使用过程中安全性要求越来越高。由于其结构上存在耦合气隙,在工作时不可避免地会介入异物。金属异物及生物体异物的介入使系统偏离正常工作点甚至引发安全事故,因此异物检测(FOD)技术受到广泛关注。... 近几年,无线电能传输技术发展迅猛,使用过程中安全性要求越来越高。由于其结构上存在耦合气隙,在工作时不可避免地会介入异物。金属异物及生物体异物的介入使系统偏离正常工作点甚至引发安全事故,因此异物检测(FOD)技术受到广泛关注。该文首先系统地阐述当前国内外无线电能传输系统异物检测技术的相关标准,并进一步指出当前检测标准存在的问题;其次将目前涌现的异物检测技术划分为辅助线圈异物检测技术、系统参数异物检测技术和传感器异物检测技术三大类别,针对每一类技术,分别分析其基本原理、解决的技术问题及检测类别,并对比三类检测技术的特性;最后进一步指出异物检测技术亟待解决的问题,为异物检测技术未来的研究提供方向。 展开更多
关键词 无线电能传输 异物检测 标准 金属异物 生物体异物
下载PDF
口腔颌面部金属异物取出61例临床总结 被引量:5
19
作者 鲁伟 高玉萍 +1 位作者 毛永惠 杨长有 《口腔颌面外科杂志》 CAS 2010年第6期429-430,共2页
目的:探讨口腔颌面部金属异物最佳手术取出途径。方法:将我科1999—2008年口腔颌面部金属异物61例诊治情况进行分析总结。结果:61例中的65个口腔颌面部金属异物都顺利取出,没有发生伤口感染,创口均愈合良好。结论:口腔颌面部异物应用平... 目的:探讨口腔颌面部金属异物最佳手术取出途径。方法:将我科1999—2008年口腔颌面部金属异物61例诊治情况进行分析总结。结果:61例中的65个口腔颌面部金属异物都顺利取出,没有发生伤口感染,创口均愈合良好。结论:口腔颌面部异物应用平板探测器X线数字成影(DDR)线片,必要时可行三维CT重建准确定位,在明确诊断后,尽量沿着原创口选择手术途径,如明视下手术取出困难可在X线透视下取出。 展开更多
关键词 口腔颌面部 金属异物 手术取出
下载PDF
超声联合CT导航行颅颌面颈部金属异物取出术32例临床分析 被引量:5
20
作者 冯杭 邢乐君 +4 位作者 王丽 陈犹白 赵蕊 步荣发 张海钟 《中国口腔颌面外科杂志》 CAS 2017年第3期231-234,共4页
目的 :研究超声联合CT导航行颅颌面颈部金属异物取出术的手术方法和临床疗效。方法 :回顾分析32例颅颌面颈部金属异物滞留患者的临床资料,通过超声联合CT导航实施异物取出。结果:32例患者的颅颌面颈部共滞留金属异物194颗,其中通过超声... 目的 :研究超声联合CT导航行颅颌面颈部金属异物取出术的手术方法和临床疗效。方法 :回顾分析32例颅颌面颈部金属异物滞留患者的临床资料,通过超声联合CT导航实施异物取出。结果:32例患者的颅颌面颈部共滞留金属异物194颗,其中通过超声导航取出36颗,通过CT导航取出153颗,取出率达97.4%;术中定位准确,出血量少,术后患者均无明显手术并发症。结论:采用超声和CT导航,可精确定位并安全取出滞留于颅颌面颈部的金属异物,避免损伤重要的生理解剖结构,取得了良好的临床疗效。 展开更多
关键词 金属异物 异物取出术 超声导航 CT导航
下载PDF
上一页 1 2 8 下一页 到第
使用帮助 返回顶部