Comparison of Ziemer FEMTO LDV "Classic" and " Crystal Line" femtosecond laser flap quality by Fourierdomain optical coherence tomography
1
作者 Jing Zhang Yue-Hua Zhou +1 位作者 Lei Tian Chang-Bin Zhai 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2013年第5期611-617,共7页
AIM:To compare the regularity and accuracy of laser in situ keratomileusis(LASIK) flaps created by the Ziemer FEMTO LDV 'Classic'(Ziemer 'Classic') and Ziemer FEMTO LDV Crystal Line femtosecond laser(Z... AIM:To compare the regularity and accuracy of laser in situ keratomileusis(LASIK) flaps created by the Ziemer FEMTO LDV 'Classic'(Ziemer 'Classic') and Ziemer FEMTO LDV Crystal Line femtosecond laser(Ziemer Crystal Line). METHODS:Fourier-domain optical coherence tomography(RTVue OCT) was used to measure the morphology of 200 LASIK flaps of 100 consecutive patients created with the Ziemer Classic(100 flaps) or the Ziemer Crystal Line(100 flaps) at one week postoperatively.Flap thickness was evaluated at 36 specified measurement points on each flap.For all procedures with both lasers,the nominal flap thickness was 110μm.RESULTS:The mean flap thickness of the Ziemer Crystal Line group(102.49±2.68μm) was thinner than that of the Ziemer Classic group(107.65±5.09μm)(P【0.01).Average thickness of all flaps was uniform within 4μm at all measurement points.The flaps in the Ziemer Crystal Line group were more regular than those in the Ziemer Classic group when measured from the center to the periphery.The maximum deviation from the nominal 110μm of 36 measurements was 8μm in the Ziemer Classic group,while in the Ziemer Crystal Line group it was 9μm.Within the 3 600 measurements on the 100 eyes,differences greater than 20μm were observed 0.14% in the Ziemer Classic group,and 0.04% in the Ziemer Crystal Line group. CONCLUSION:The flaps created with the Ziemer FEMTO LDV Crystal Line femtosecond laser are more uniform and thinner than those created by the Ziemer FEMTO LDV Classic femtosecond laser. 展开更多
关键词 laser in situ keratomileusis flap thickness femtosecond laser fourier-domain optical coherence tomography
下载PDF
BINARY TISSUE CLASSIFICATION STUDIES ON RESECTED HUMAN BREAST TISSUES USING OPTICAL COHERENCE TOMOGRAPHY IMAGES
2
作者 M.BHATTACHARJEE P.C.ASHOK +3 位作者 K.DIVAKAR RAO S.K.MAJUMDER Y.VERMA P.K.GUPTA 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2011年第1期59-66,共8页
We report the results of a comparative study of Fourier domain analysis(FDA)and texture analysis(TA)of optical coherence tomography(OCT)images of resected human breast tissues for binary classification between normal... We report the results of a comparative study of Fourier domain analysis(FDA)and texture analysis(TA)of optical coherence tomography(OCT)images of resected human breast tissues for binary classification between normalabnormal classes and benignmalignant classes.With the incorporation of Fisher linear discriminant analysis(FLDA)in TA for feature extraction,the TA-based algorithm provided improved diagnostic performance as compared to the FDAbased algorithm in discriminating OCT images corresponding to breast tissues with three different pathologies.The specificity and sensitivity values obtained for normalabnormal classification were both 100%,whereas they were 90% and 85%,respectively for benignmalignant classification. 展开更多
关键词 Optical coherence tomography breast tissue texture analysis fourier domain analysis CLASSIFICATION
下载PDF
Angle-to-angle and spur-to-spur distance analysis with high-resolution optical coherence tomography
3
作者 Robert Montes-Mico Pedro Tana-Rivero +3 位作者 Salvador Aguilar-Corcoles Maria Ruiz-Santos Maria Dolores Rodriguez-Carillo Ramon Ruiz-Mesa 《Eye and Vision》 SCIE CSCD 2023年第1期1-13,共13页
Background:To measure angle-to-angle(ATA)and spur-to-spur(STS)distances along six meridians using highresolution swept-source optical coherence tomography(SS-OCT)and to compare those values with horizontal white-to-wh... Background:To measure angle-to-angle(ATA)and spur-to-spur(STS)distances along six meridians using highresolution swept-source optical coherence tomography(SS-OCT)and to compare those values with horizontal white-to-white(WTW)distance.Methods:Sixty-eight eyes from 68 patients were quantitatively assessed with the Anterion SS-OCT(Heidelberg Engineering,Heidelberg,Germany).ATA and STS distances were measured with the SS-OCT B-scan in six cross-sectional images corresponding to the vertical(6-12 o'clock),1-7 o'clock,2-8 o'clock,horizontal(3-9 o'clock),4-10 o'clock and 5-11 o'clock meridians.WTW was measured horizontally with the device's infrared camera.A Pearson correlation analysis was carried out to compare ATA and STS distances with WTW.Results:The largest values were found for the vertical meridian and the shortest for the 2-8 o'clock meridian,both for ATA and STS distances.No statistically significant differences were found between WTW,ATA and STS along the horizontal meridian(P>0.1).However,ATA and STS showed statistically significant differences elsewhere,except for the horizontal and the 2-8 o'clock meridians(P>0.05).Moreover,we found that ATA and STS varied significantly depending on the meridian being assessed,except for ATA at 4-10 versus 3-9 o'clock and for STS at 4-10 versus 3-9 o'clock and at 3-9 versus 2-8 o'clock(P>0.1).R2 values ranged from 0.49 to 0.75 for ATA and STS at the different meridians,showing the best correlation at 3-9 o'clock meridian(0.64 and 0.75,respectively)and the worst at 6-12 o'clock meridian(R2=0.49 for both ATA and STS).Conclusions:ATA and STS distances vary radially,thus showing that the anterior chamber is vertically oval.Therefore,it is advisable to measure these two distances along the meridian to be used. 展开更多
关键词 Angle-to-angle Spur-to-spur White-to-white Optical coherence tomography Swept-source fourier domain
原文传递
Diagnostic capability of Fourier-Domain optical coherence tomography in early primary open angle glaucoma 被引量:10
4
作者 FANG Yuan PAN Ying-zi LI Mei QIAO Rong-hua CAI Yu 《Chinese Medical Journal》 SCIE CAS CSCD 2010年第15期2045-2050,共6页
Background Optical coherence tomography (OCT) is a high resolution noncontact imaging modality which can quantitatively detect the optic disc and retinal structure.This study was designed to evaluate the diagnostic ... Background Optical coherence tomography (OCT) is a high resolution noncontact imaging modality which can quantitatively detect the optic disc and retinal structure.This study was designed to evaluate the diagnostic capability of parameters of the optic disc, retinal nerve fiber layer thickness, and ganglion cell complex (GCC) using a new technology called Fourier-domain OCT (FD-OCT) for early primary open angle glaucoma (POAG) patients.Methods Two groups of patients, early perimetric damage POAG and normal subjects were included in this observational cross-sectional study.All patients underwent FD-OCT and visual field examination in addition to full ophthalmic examinations.Receiver operating characteristic curves (ROC) were studied for all parameters.The sensitivity and specificity for distinguishing between normal and early glaucomatous eyes, the areas under the receiver operating characteristic curves (AROC) and positive, negative likelihood ratios were evaluated for all the single parameters and selected combined parameters using arbitrary cutoffs.Results Thirty-four eyes of 34 early POAG patients and 42 eyes of 42 normal subjects were analyzed.Cup/disc (C/D)vertical ratio presented the best sensitivity and positive likelihood ratio for selected specificities (95% and 85%) which were 79.4% and 88.2%, 33.4 and 7.4, respectively.Among all single parameters, the C/D vertical ratio demonstrated the highest AROC which was at 0.930.The average thickness of circumpapillary RNFL on 3.45 mm showed the highest AROC among all of the peripapillary RNFL parameters.The sensitivity at selected specificity and AROC of GCC were not as high as C/D vertical ratio and RNFL AT on 3.45 mm.When the C/D vertical ratio, RNFL AT on 3.45 mm, and rim area were combined using a logistical diagnostic model, the AROC was raised to 0.949 but not significantly different from the top single parameter, C/D vertical ratio.Conclusions The key parameters obtained by FD-OCT were able to show the significant differences of optic discs,thickness of RNFL and GCC between POAG patients and normal subjects.According to sensitivity, specificity, likelihood ratio and AROC, the top three parameters from FD-OCT for early diagnosis of POAG were C/D vertical ratio, RNFL AT on 3.45 mm, and the rim area. 展开更多
关键词 fourier-Domain optical coherence tomography early primary open angle glaucoma retinal nerve fiber layerp optic disc parameter ganglion cell complex
原文传递
迈克耳孙干涉仪与光学自相关测量 被引量:3
5
作者 张朝晖 《物理实验》 2023年第1期49-63,共15页
“迈克耳孙干涉仪与光学自相关测量”是北京大学基础物理实验教学中心开设“综合物理实验”课程中的实验项目.作为该项目的教学辅助材料,本文旨在引导学生在熟悉教学型迈克耳孙干涉仪及其实验的基础上,尝试理解迈克耳孙干涉原理在现代... “迈克耳孙干涉仪与光学自相关测量”是北京大学基础物理实验教学中心开设“综合物理实验”课程中的实验项目.作为该项目的教学辅助材料,本文旨在引导学生在熟悉教学型迈克耳孙干涉仪及其实验的基础上,尝试理解迈克耳孙干涉原理在现代科技中的应用,深入研究基于迈克耳孙干涉仪器的光学自相关测量机制,搭建基于教学型迈克耳孙干涉仪的傅里叶变换光谱仪或者光学相干层析成像的实验系统,探究相关的物理与技术问题.文中插入了一些“思考与练习”的题目,希望学生能以问题为导向来具体理解相关的物理内容和实验技术.最后的“教学要求”明确了实验的基本内容、面谈环节重点讨论的具体问题和后续深入研究的主要方向. 展开更多
关键词 综合物理实验 迈克耳孙干涉仪 光学自相关测量 引力波测量 傅里叶变换光谱检测 光学相干层析成像
下载PDF
Angle-to-angle and spur-to-spur distance analysis with high-resolution optical coherence tomography 被引量:2
6
作者 Robert Montés-Micó Pedro Tañá-Rivero +3 位作者 Salvador Aguilar-Córcoles María Ruiz-Santos María Dolores Rodríguez-Carrillo Ramón Ruiz-Mesa 《Eye and Vision》 SCIE CSCD 2020年第1期399-411,共13页
Background:To measure angle-to-angle(ATA)and spur-to-spur(STS)distances along six meridians using highresolution swept-source optical coherence tomography(SS-OCT)and to compare those values with horizontal white-to-wh... Background:To measure angle-to-angle(ATA)and spur-to-spur(STS)distances along six meridians using highresolution swept-source optical coherence tomography(SS-OCT)and to compare those values with horizontal white-to-white(WTW)distance.Methods:68 eyes from 68 patients were quantitatively assessed with the Anterion SS-OCT(Heidelberg Engineering,Heidelberg,Germany).ATA and STS distances were measured with the SS-OCT’s B-Scan in six cross-sectional images corresponding to the vertical(6-12 o’clock),1-7 o’clock,2-8 o’clock,horizontal(3-9 o’clock),4-10 o’clock and 5-11 o’clock meridians.WTW was measured horizontally with the device’s infrared camera.A Pearson correlation analysis was carried out to compare ATA and STS distances with WTW.Results:The largest values were found for the vertical meridian and the shortest for the 2-8 o’clock meridian,both for ATA and STS distances.No statistically significant differences were found between WTW,ATA and STS along the horizontal meridian(p>0.1).However,ATA and STS showed statistically significant differences elsewhere,except for the horizontal and the 2-8 o’clock meridians(p>0.05).Moreover,we found that ATA and STS varied significantly depending on the meridian being assessed,except for ATA at 4-10 versus 3-9 o’clock and for STS at 4-10 versus 3-9 o’clock and at 3-9 versus 2-8 o’clock(p>0.1).R^(2) values ranged from 0.49 to 0.75 for ATA and STS at the different meridians,showing the best correlation at 3-9 o’clock meridian(0.64 and 0.75,respectively)and the worst at 6-12 o’clock meridian(R^(2)=0.49 for both ATA and STS).Conclusions:ATA and STS distances vary radially,thus showing that the anterior chamber is vertically oval.Therefore,it is advisable to measure these two distances along the meridian to be used. 展开更多
关键词 Angle-to-angle Spur-to-spur White-to-white Optical coherence tomography Swept-source fourier domain
原文传递
FD-OCT、Visante OCT及A超角膜测厚仪测量人中央角膜厚度的比较 被引量:10
7
作者 徐玲娟 赵靖 +2 位作者 谢立信 吴洁 孙大鹏 《眼科新进展》 CAS 北大核心 2011年第3期250-253,共4页
目的比较FD-OCT、Visante OCT及A超角膜测厚仪测量人中央角膜厚度的差异,为临床检查提供参考。方法 选取健康志愿者27人(54眼),依次用FD-OCT、VisanteOCT及A超角膜测厚仪测量双眼中央角膜厚度,三种仪器均测量3次,取其平均值,对所得数... 目的比较FD-OCT、Visante OCT及A超角膜测厚仪测量人中央角膜厚度的差异,为临床检查提供参考。方法 选取健康志愿者27人(54眼),依次用FD-OCT、VisanteOCT及A超角膜测厚仪测量双眼中央角膜厚度,三种仪器均测量3次,取其平均值,对所得数据进行统计学分析。结果 54眼志愿者中央角膜厚度测量结果:FD-OCT测量值为(530.74±31.74)μm,Visante OCT为(554.06±33.32)μm,A超为(531.61±31.76)μm。三种测量方法结果差异有统计学意义(F=9.053,P<0.01)。两两比较显示:FD-OCT测量结果与A超相比,差异无统计学意义(P>0.05);Visante OCT与A超相比,差异有统计学意义(P<0.05);Visante OCT和FD-OCT相比,差异也有统计学意义(P<0.05),但两种测量结果高度相关(r=0.949),前者所测中央角膜厚度较后者厚(23.32±10.46)μm,两者差值的95%可信区间为20.46~26.17μm。结论 A超作为目前角膜厚度测量的金标准,随着检查舒适度、检查速度等要求的提高,使用渐显局限。新的角膜测厚仪的出现,有望改善这些问题,但是诊断分析时需注意其可能带来的测量结果偏差。 展开更多
关键词 中央角膜厚度 A超角膜测厚仪 FD-OCT Visante OCT 对比研究
下载PDF
视网膜神经节细胞复合体厚度与神经纤维层厚度的相关性以及在青光眼诊断中的意义 被引量:13
8
作者 潘艳杰 王保君 +3 位作者 张海涛 杨华 周朝元 牛珊珊 《眼科新进展》 CAS 北大核心 2013年第9期843-846,共4页
目的利用傅立叶光学相干断层扫描技术(Fourier-domain optical coherence tomography,FD-OCT)比较正常人、早期青光眼、进展期青光眼患者各部位视网膜神经纤维层(peripapillary retinal never fiber layer,pRNFL)厚度及黄斑区各部位神... 目的利用傅立叶光学相干断层扫描技术(Fourier-domain optical coherence tomography,FD-OCT)比较正常人、早期青光眼、进展期青光眼患者各部位视网膜神经纤维层(peripapillary retinal never fiber layer,pRNFL)厚度及黄斑区各部位神经节细胞复合体(macular ganglion cell complex,mGCC)厚度差异,评价并分析其在青光眼中的诊断能力分析各参数的诊断能力。方法选取正常人41例(56眼)为正常组,早期青光眼组患者36例(42眼),进展期青光眼组患者35例(39眼),使用FD-OCT测量pRNFL及mGCC厚度,并对数据进行统计学分析,受试者曲线下面积(area under receive operated curve,AROC)。分析各参数的诊断能力。结果青光眼组各部位pRNFL厚度及mGCC厚度值随青光眼的严重程度逐渐减小,各参数的差异均有显著统计学意义(均为P<0.01)。正常组、早期青光眼组及进展期青光眼组平均、下方的mGCC与pRNFL具有相关性(r值分别为0.433、0.693、0.615、0.833、0.725、0.818;0.840、0.658、0.904;均为P<0.01)。早期青光眼组与正常组相比,除鼻侧象限之外(P=0.102),其余颞侧、上方、下方pRNFL及所有mGCC参数的AROC差异均有统计学意义(均为P<0.01)。对于总体青光眼(早期及进展期青光眼)与正常组比较发现,所有pRNFL及mGCC参数的AROC值差异均有统计学意义(pRNFL:0.941±0.020,mGCC:0.920±0.022,P<0.01)。所有pRNFL与mGCC参数之间的诊断能力差异无统计学意义(均为P>0.05)。结论 mGCC厚度与pRNFL厚度的检测在青光眼早期诊断能力中具有可比较性。黄斑区GCC厚度的测量对RNFL在临床青光眼诊断中是一个很好的补充检查手段。 展开更多
关键词 FD-OCT 视网膜神经节复合体 视网膜神经纤维层 青光眼
下载PDF
傅立叶域光学相干断层扫描、A型超声测厚仪和超声生物显微镜测量角膜厚度的相关性分析 被引量:9
9
作者 赵博 马世江 +1 位作者 陈革 王永毅 《眼科新进展》 CAS 北大核心 2013年第7期661-663,共3页
目的探讨傅立叶域光学相干断层扫描(FD-OCT)、A型超声测厚仪和超声生物显微镜(ultrasound biomicroscopy,UBM)测量角膜厚度的差异和可重复性。方法应用RTVue傅立叶域OCT(RTVue FD-OCT)、A型超声测厚仪和UBM对39例志愿者随机选取一眼进... 目的探讨傅立叶域光学相干断层扫描(FD-OCT)、A型超声测厚仪和超声生物显微镜(ultrasound biomicroscopy,UBM)测量角膜厚度的差异和可重复性。方法应用RTVue傅立叶域OCT(RTVue FD-OCT)、A型超声测厚仪和UBM对39例志愿者随机选取一眼进行角膜厚度测量,对三种不同测量仪器测得的角膜厚度值进行比较,采用Pearson相关分析评价三种仪器测量值之间的相关性,对三种测量方法重复测量值的方差进行方差分析,比较三种测量方法的可重复性。结果 RTVue FD-OCT、UBM和A型超声测厚仪测量的角膜厚度值分别为(543.34±34.09)μm、(538.02±33.17)μm、(536.24±31.16)μm,RT-Vue FD-OCT与UBM、A型超声测厚仪的测量值之间差异均有统计学意义(均为P<0.05),UBM与A型超声测厚仪的测量值差异无统计学意义(P>0.05)。三种测量仪器的测量值均呈正相关(r=0.983、0.966、0.938,均为P<0.01);RTVue FD-OCT、A型超声测厚仪和UBM角膜厚度重复测量值的方差值分别为3.53±2.87、5.43±3.13、6.64±3.26,RTVueFD-OCT测量可重复性好于A型超声测厚仪和UBM。结论 RTVueFD-OCT、A型超声测厚仪和UBM测量角膜厚度有很好的相关性,RTVueFD-OCT测量可重复性好,且安全、无创,可用于角膜厚度的精确测量。 展开更多
关键词 傅立叶域光学相干断层扫描 A型超声测厚仪 超声生物显微镜 角膜厚度
下载PDF
频域光学相干层析术系统中高准确度高灵敏度补偿色散法 被引量:5
10
作者 陈朝良 高万荣 卞海溢 《光子学报》 EI CAS CSCD 北大核心 2014年第2期153-158,共6页
将色散测量方法和快速扫描延迟线技术相结合,在谱域光学相干层析系统中实现了对群延迟色散的精确补偿.在该方法中,先在样品臂中放入平面反射镜,等间隔移动参考臂中快速扫描延迟线系统中光栅的位置,同时测量系统参考臂和样品臂之间的群... 将色散测量方法和快速扫描延迟线技术相结合,在谱域光学相干层析系统中实现了对群延迟色散的精确补偿.在该方法中,先在样品臂中放入平面反射镜,等间隔移动参考臂中快速扫描延迟线系统中光栅的位置,同时测量系统参考臂和样品臂之间的群延迟色散差值.当该值为零时,则表明系统色散匹配.将该方法与基于点扩散函数半高宽的方法进行比较,发现基于半高宽方法的测量误差为4.43%,而该方法的测量误差为0.76%;在色散补偿过程中,随着色散匹配点的靠近,半高宽方法的灵敏度由92.105 3fs2减小到1.344 7×103 fs2,而新方法的灵敏度则保持165.789 5fs2,表明本文提出的色散补偿法具有较高的色散补偿准确度和灵敏度.实验表明,色散补偿后的系统分辨率接近理论值;在补偿系统色散的同时,还可以根据测量所得色散值的符号来判定光栅的移动方向,从而更容易地完成补偿工作. 展开更多
关键词 医用光学 低相干干涉 频域光学相干层析术 快速扫描延迟线 色散补偿 色散测量 傅里叶变换
下载PDF
傅立叶OCT对不同年龄正常人群角膜厚度的测量研究 被引量:3
11
作者 杨柳 瞿远珍 +2 位作者 刘翠芳 陆雯 刘凤军 《国际眼科杂志》 CAS 2013年第4期674-676,共3页
目的:研究傅立叶域光学相干断层成像系统(Fourier-domain optical coherence tomography,FD-OCT)测量不同年龄人群角膜厚度正常值。方法:选取健康受试者210例420眼,分为3组,青年组(18~40岁)70例140眼;中年组(41~60岁)70例140眼;老年组... 目的:研究傅立叶域光学相干断层成像系统(Fourier-domain optical coherence tomography,FD-OCT)测量不同年龄人群角膜厚度正常值。方法:选取健康受试者210例420眼,分为3组,青年组(18~40岁)70例140眼;中年组(41~60岁)70例140眼;老年组(≥61岁)70例140眼。用傅立叶OCT检测受试者双眼角膜中心区、内环区和外环区角膜厚度及平均角膜厚度。结果:通过FD-OCT测量的不同区域角膜厚度最薄处位于角膜中心区,平均厚度527.19±1.72μm;最厚处在外环上方,平均厚度582.42±2.50μm;左右眼不同区域间角膜厚度差异没有统计学意义(P>0.05)。通过FD-OCT测量的平均角膜厚度在三个不同年龄组间具有很好的一致性及相关性(右眼:青年组-中年组:r=0.949,中年组-老年组:r=0.924,青年组-老年组:r=0.981;左眼:青年组-中年组:r=0.996,中年组-老年组:r=0.901,青年组-老年组:r=0.876)。结论:采用FD-OCT前节功能测量角膜厚度具有可重复性、可信性、方便性,可以更好地代表实际上的角膜厚度。 展开更多
关键词 FD—OCT 角膜厚度 不同区域
下载PDF
频域OCT图像的深度坐标标定 被引量:3
12
作者 林凌 李刚 +1 位作者 张泰石 郑羽 《仪器仪表学报》 EI CAS CSCD 北大核心 2008年第3期466-471,共6页
为了对频域OCT图像深度坐标进行标定,本文提出了一种方法,并进行了实验验证。频域OCT图像深度坐标由宽带光源的特性与样品的不均匀折射率决定,因而坐标间隔不均。最大深度坐标(频域OCT的探测深度)由线阵CCD的像素总数和参考镜的虚像位... 为了对频域OCT图像深度坐标进行标定,本文提出了一种方法,并进行了实验验证。频域OCT图像深度坐标由宽带光源的特性与样品的不均匀折射率决定,因而坐标间隔不均。最大深度坐标(频域OCT的探测深度)由线阵CCD的像素总数和参考镜的虚像位置决定:线阵CCD的像素总数越多,最大深度坐标越大,但最终被光谱仪的分辨率所限制;参考镜的虚像位置设于样品以内时,最大深度坐标比参考镜的虚像位置设于样品以外时大一倍。该方法可以应用到实际频域OCT系统中。 展开更多
关键词 光学相干层析成像技术 迈克尔逊干涉仪 傅里叶周期 空间频率
下载PDF
光学相干断层成像技术的临床应用新进展 被引量:7
13
作者 申晓丽 黄丽娜 《国际眼科杂志》 CAS 2009年第12期2395-2398,共4页
光学相干断层成像术(optical coherence tomography,OCT)是一种能对生物组织浅表微结构进行断层成像的新技术,我们对时域光学相干断层成像术(time domain opticalcoherence tomography,TD-OCT)与傅立叶域光学相干断层成像术(fourier dom... 光学相干断层成像术(optical coherence tomography,OCT)是一种能对生物组织浅表微结构进行断层成像的新技术,我们对时域光学相干断层成像术(time domain opticalcoherence tomography,TD-OCT)与傅立叶域光学相干断层成像术(fourier domain optical coherence tomography,FD-OCT)的成像原理、两者性能参数进行了比较,介绍了三维OCT在眼科的应用,以及近年来得到快速发展的新OCT技术,包括:多普勒OCT、偏振敏感OCT、光谱型OCT和双光线OCT,以及OCT技术在生物医学领域的应用前景。 展开更多
关键词 光学相干断层成像术 傅立叶域OCT 三维OCT OCT应用前景
下载PDF
光学相干层析成像色散补偿研究 被引量:3
14
作者 林林 高应俊 +2 位作者 龙炳昌 蔡里禹 何永健 《光子学报》 EI CAS CSCD 北大核心 2010年第6期1099-1103,共5页
针对通过增加光源谱宽度来提高光学相干层析成像系统分辨率时样品色散特性的限制作用,分析了色散与光学相干层析成像系统纵向光程分辨率的约束关系.根据物质色散特性,采用数值变换方法对光学相干层析成像相干成像信号进行了色散补偿.实... 针对通过增加光源谱宽度来提高光学相干层析成像系统分辨率时样品色散特性的限制作用,分析了色散与光学相干层析成像系统纵向光程分辨率的约束关系.根据物质色散特性,采用数值变换方法对光学相干层析成像相干成像信号进行了色散补偿.实验使用了中心波长1550nm自激发辐射光源和光纤迈克尓逊干涉结构,对水和光学快速扫描延迟线引入的二阶和三阶色散进行了数值补偿并通过相位修正因子来改善补偿效果.确定了一种普适的、快速的数值色散补偿方法.在对水中盖玻片和生物组织和的光学相干层析成像图像的色散补偿实验中取得了良好的效果,证明了方法的可行性. 展开更多
关键词 医用光学与生物技术 色散补偿 快速傅里叶变换 光学相干层析
下载PDF
Med-Logics 0、-10和-20刀片制作LASIK角膜瓣的评估 被引量:3
15
作者 高旭 周跃华 +2 位作者 张晶 张青蔚 田磊 《眼科新进展》 CAS 北大核心 2012年第2期155-159,共5页
目的探讨Med-Logics0、-10和-20刀片制作准分子激光原位角膜磨镶术(laser in situ keratomileusis,LASIK)角膜瓣的特点。方法入选近视患者共210例(420眼)行LASIK,按所应用刀片的不同,分为0、-10和-20刀片组,每组各70例(140眼)。术后7d,... 目的探讨Med-Logics0、-10和-20刀片制作准分子激光原位角膜磨镶术(laser in situ keratomileusis,LASIK)角膜瓣的特点。方法入选近视患者共210例(420眼)行LASIK,按所应用刀片的不同,分为0、-10和-20刀片组,每组各70例(140眼)。术后7d,应用OCT分别测量每个角膜上0°、90°两条经线所在截面上特定7个点的角膜瓣厚度,并对每个角膜瓣上14个测量点的角膜瓣厚度进行对比分析。采用独立样本t检验、单因素方差分析对数据进行统计学处理。结果 0、-10和-20刀片组中央角膜瓣厚度均值分别为(134.0±14.0)μm、(113.5±10.4)μm和(107.9±12.6)μm,0刀片组明显高于-10刀片组和-20刀片组,而-10刀片组和-20刀片组差异没有统计学意义(P>0.05)。三组角膜中央区域和周边区域差异均有统计学意义(均为P<0.005)。三组中制作角膜瓣双眼鼻侧和颞侧角膜瓣厚度比较,各组内差异均有统计学意义(均为P<0.05)。三组中各自角膜上两条经线所在截面的平均角膜瓣厚度差异均无统计学意义(均为P>0.05)。0刀片组中与理论值差值≤15μm者有948个测量点(48.4%);-10刀片组中与理论值差值≤15μm者有1118个测量点(57.0%);-20刀片组中与理论值差值≤15μm者有1020个测量点(52.0%)。结论 110Moria微型角膜刀应用常规0刀片、-10和-20刀片角膜瓣,重现性较好,-10刀片和-20刀片相比角膜瓣中央区角膜瓣厚度和全角膜平均厚度无明显差异,三组角膜瓣的厚度值鼻侧和颞侧相比有显著性差异。 展开更多
关键词 准分子激光原位角膜磨镶术 角膜瓣厚度 微型角膜刀 傅里叶光学相干断层扫描
下载PDF
复谱频域OCT成像的研究 被引量:2
16
作者 郑羽 李刚 +2 位作者 张泰石 林凌 刘晶晶 《光子学报》 EI CAS CSCD 北大核心 2007年第B06期205-208,共4页
采用频域技术的OCT系统,深度扫描信息由背向散射光谱的傅立叶反变换获得,简化了轴向扫描过程,从而使快速OCT成像成为可能.为了实现复杂生物组织的OCT快速成像,消除谱频域OCT的"混叠"现象、重建样品的真实层析结构,本文引入了... 采用频域技术的OCT系统,深度扫描信息由背向散射光谱的傅立叶反变换获得,简化了轴向扫描过程,从而使快速OCT成像成为可能.为了实现复杂生物组织的OCT快速成像,消除谱频域OCT的"混叠"现象、重建样品的真实层析结构,本文引入了相移干涉技术,构建了一套满量程复谱频域OCT实验系统,并为系统设计了特殊的分束镜和移相器,为最终实现复杂生物组织的OCT快速成像提供了条件. 展开更多
关键词 光学相干层析成像 复谱频域OCT 图像重建
下载PDF
在多层介质中的频域OCT蒙特卡罗仿真 被引量:4
17
作者 李刚 郑羽 +1 位作者 林凌 刘晶晶 《光学精密工程》 EI CAS CSCD 北大核心 2008年第7期1285-1294,共10页
选择多层介质作为样品,根据波恩一阶近似理论建立了单次散射的无限细直光束频域OCT模型,并分析了散射积分方程很难得到精确解的原因。蒙特卡罗仿真结果表明,一类和二类光子出射后在空间的分布存在着一定的差异,通过调整接收器的面积,可... 选择多层介质作为样品,根据波恩一阶近似理论建立了单次散射的无限细直光束频域OCT模型,并分析了散射积分方程很难得到精确解的原因。蒙特卡罗仿真结果表明,一类和二类光子出射后在空间的分布存在着一定的差异,通过调整接收器的面积,可以在一定程度上很好地抑制二类光子,尽可能多地接收一类光子;通过分析时域OCT与频域OCT的区别,进一步确立了频域OCT的优势地位;通过改变复杂生物组织的模型结构,对由于能量衰减而造成的图像灰度失真做了近似的补偿。 展开更多
关键词 蒙特卡罗仿真 频域OCT 一阶Born近似 多层介质
下载PDF
眼前节OCT测量法对FS200飞秒激光和Moria90刀头行薄瓣LASIK中角膜瓣形态比较 被引量:2
18
作者 翟长斌 郝颖娟 +3 位作者 易省平 刘娟 张晶 周跃华 《中华实验眼科杂志》 CAS CSCD 北大核心 2013年第8期770-774,共5页
背景 薄瓣准分子激光角膜原位磨镶术(LASIK)是角膜屈光手术的主流方法,越来越多的薄瓣LASIK应用飞秒激光制作角膜瓣,傅里叶眼前节OCT角膜瓣厚度及形态的测量为角膜瓣和角膜基质层厚度的控制提供了依据,但应用眼前节OCT测量法对FS200... 背景 薄瓣准分子激光角膜原位磨镶术(LASIK)是角膜屈光手术的主流方法,越来越多的薄瓣LASIK应用飞秒激光制作角膜瓣,傅里叶眼前节OCT角膜瓣厚度及形态的测量为角膜瓣和角膜基质层厚度的控制提供了依据,但应用眼前节OCT测量法对FS200飞秒激光和Moria 90刀头行薄瓣LASIK中角膜瓣形态进行比较的研究较少. 目的 利用傅里叶频域OCT测量法比较应用Wavelight FS200飞秒激光和传统微型角膜刀Moria 90刀头制作的角膜瓣形态及其厚度,评价两种方法制作角膜瓣的特点. 方法 选取2011年12月至2012年6月在南京同仁医院眼科行FS200飞秒激光辅助LASIK和Moria 90刀头行LASIK的患者各30例30眼,于术后1个月应用傅里叶频域OCT(OPTOVUE RTVue-100)测量和比较两种方法所制的中央角膜瓣厚度以及角膜0°和90°径线所在截面上特定10个点的角膜瓣厚度. 结果 FS200飞秒激光制瓣组术眼中央角膜瓣厚度值为(112±3)μm,全角膜瓣平均厚度值为(112±3) μm,分别低于Moria 90刀头制瓣组的(121±7) μm及(128±11) μm,差异均有统计学意义(P=0.031、0.030),FS200飞秒激光制瓣组角膜瓣厚度的变异范围也明显小于Moria 90刀头制瓣组.FS200飞秒激光制作的角膜瓣形态规整、均一,形状近似规则的平面,其中央、旁中央、周边厚度的差异无统计学意义(P=0.320).Moria 90刀头制作的角膜瓣中间薄,周边厚,近似弯月形透镜,其中央、旁中央、周边区角膜瓣厚度的差异有统计学意义(P=0.038).FS200飞秒激光制瓣组各测量点角膜瓣厚度与预期角膜瓣厚度(110 μm)的平均差为(3±4)μm,而Moria 90刀头制瓣组为(17±10) μm,两组间差异有统计学意义(P=0.009).结论 傅里叶眼前节OCT测量表明,Wavelight FS200飞秒激光制作角膜瓣精确度高,可控性强,稳定性好,且操作更安全,是薄瓣LASIK的首选.傅里叶眼前节OCT是评价LASIK术后角膜瓣形态和厚度的有用工具. 展开更多
关键词 傅里叶光学相干断层扫描 飞秒激光 角膜 屈光手术 准分子激光角膜原位磨镶术 膜瓣厚度
下载PDF
从迈克耳孙干涉仪到光学相干层析术 被引量:12
19
作者 郭永康 姚欣 《大学物理》 北大核心 2007年第1期1-6,共6页
介绍了迈克耳孙干涉仪在物理学发展史上的重要作用及生物医学成像技术的发展状况.从迈克耳孙干涉仪的发展过程出发,讨论了光学相干层析术的原理、特性及其在生物医学成像、物理学、材料科学中的应用,并将频谱光学相干层析术与傅里叶变... 介绍了迈克耳孙干涉仪在物理学发展史上的重要作用及生物医学成像技术的发展状况.从迈克耳孙干涉仪的发展过程出发,讨论了光学相干层析术的原理、特性及其在生物医学成像、物理学、材料科学中的应用,并将频谱光学相干层析术与傅里叶变换光谱术作了比较,最后讨论了它在教学上的意义. 展开更多
关键词 光学相干层析术 迈克耳孙干涉仪 傅里叶变换光谱仪 频谱光学相干层析术
下载PDF
二维频域光学相干层析系统研究 被引量:2
20
作者 游腾飞 钟舜聪 +2 位作者 钟剑锋 张秋坤 罗曼婷 《机电工程》 CAS 2015年第5期602-606,共5页
针对时域光学相干层析成像系统的成像速度较慢的问题,采用VC++与Matlab混合编程技术开发了二维频域光学相干层析成像系统,实现了对被测样品进行内部快速成像;搭建二维频域光学相干层析成像系统代替一维频域光学相干层析成像系统;利用计... 针对时域光学相干层析成像系统的成像速度较慢的问题,采用VC++与Matlab混合编程技术开发了二维频域光学相干层析成像系统,实现了对被测样品进行内部快速成像;搭建二维频域光学相干层析成像系统代替一维频域光学相干层析成像系统;利用计算机驱动面阵CCD相机对干涉信号进行采集得到干涉信号;采用计算机驱动NI卡对压电陶瓷(PZT)移相器进行相移控制以达到频域光学相干层析成像系统对移相的需求,利用计算机驱动线性电动移动平台实现检测样品进行横向扫描以达到对样品进行三维成像。研究结果表明,该系统集成度高,开发的软件功能齐全、界面友好、便于维护和升级;该二维系统相比一维光学相干层析成像系统而言减少了一维的扫描采集次数,大大提高了成像速度。 展开更多
关键词 VC++ MATLAB 二维 频域光学相干层析
下载PDF