Objective: The aim of our study was to investigate the impact of abdominal hypo-fraction irradiation on liver damage in rats so as to provide a reference for its clinical application. Methods: A total of 100 Wistar ra...Objective: The aim of our study was to investigate the impact of abdominal hypo-fraction irradiation on liver damage in rats so as to provide a reference for its clinical application. Methods: A total of 100 Wistar rats were equally randomized to five groups as control, 4 Gy, 6 Gy, 8 Gy and 12 Gy group, and the corresponding fractionated doses were offered. Liver functions were examined at the 2nd, 4th, 6th, 8th and 10th week after irradiation. Morphological changes were observed by HE staining. Expressions of Bcl-2 and Bax were examined by immunohistochemical technique. Results: In all irradiation groups, hepatocellular swell, degeneration, necrosis and even hepatic fibrosis could be seen. The differences of the liver coefficient, Glutamyl pyruvic transaminase (GPT), Glutamyl oxaloacetic transaminase (GOT) were significant among the groups and different time points (F = 11.833-781.972, F = 20.857-264.692, P < 0.001). Expressions of Bcl-2 and Bax were significantly different between each group (F = 211.607, 116.577; P < 0. 001), and between each time point (F = 54.083, 68.749; P < 0. 001). Conclusion: Compare with conventional fraction, abdominal hypo-fraction irradiation may cause radiation damage to rat liver, being dose-and-time dependent. Up-regulation of activating apoptosis protein Bax and down-regulation of inhibiting apoptosis protein Bcl-2 may involve in the process.展开更多
The low dose effects induced by carbon ions on Chinese hamster V79 cells and murine melanoma B16 cells were investigated in this paper. Both cell lines were divided into four groups for irradiation: (1) control, (2) 0...The low dose effects induced by carbon ions on Chinese hamster V79 cells and murine melanoma B16 cells were investigated in this paper. Both cell lines were divided into four groups for irradiation: (1) control, (2) 0.02 Gy or 0.05 Gy(D1), (3) 1 Gy(D2), (4) D1+D2. The survivors and micronuclei were studied as biological endpoints. The results of group (1) and group (2) showed that there were no obvious differences on micronucleus frequency but there were significant increases when irradiation dose was 0.02Gy on colony formation efficiency. Although low dose ion irradiation could not contribute to DNA damages, it could enhance the colony formation efficiency. In the study of group (3) and (4), when the ion dose was 0.02 Gy, there were evident increases on surviving fraction and decreases on micronucleus frequency, but there were no statistical changes on these endpoints when the ion dose was 0.05Gy. This meant that high LET radiation could induce the adaptive response of cultured cells, furthermore, in the range of inducing ion dose , low dose irradiation was more profitable than high dose one.展开更多
In this study, the activity concentrations of ^(226)Ra,^(232)Th,^(222)Rn, and ^(40)K, emanation fractions(P),equilibrium equivalent concentration(EEC), and mass exhalation rates(E_m) of radon released from building ma...In this study, the activity concentrations of ^(226)Ra,^(232)Th,^(222)Rn, and ^(40)K, emanation fractions(P),equilibrium equivalent concentration(EEC), and mass exhalation rates(E_m) of radon released from building materials used in Malaysia were studied using gamma-ray spectrometer with HPGe detector. Radiological parameters[activity concentration index(ACI), indoor air-absorbed dose rate(D_(in)), annual effective dose(AED_(in)) from external and internal(E_(Rn)), soft tissues(H_(ST)) and lung(H_L), and effective dose equivalent(H_(eff))] were estimated to evaluate radiological hazards due to the use of these building materials: sand, cement, gravel, bricks, tiles, fly ash, white cement, and ceramic raw materials. The measured P, EEC,and E_m vary from 10 to 30%, 0.9 to 22 Bq m^(-3), and 33 to 674 mBq h^(-1) kg^(-1), respectively, while the calculated ACI and AED_(in) vary from 0.1 ± 0.01 to 2.1 ± 0.1 and 0.1 ± 0.01 to 2.4 ± 0.6 mSv y^(-1), respectively. On the other hand, the internal annual effective dose ranges from 0.1 to 1.4 mSv y^(-1). The estimated radiological risk parameters were below the recommended maximum values, and radiological hazards associated with building materials under investigation are therefore negligible.展开更多
Because the mover and stator of a doubly-fed linear motor are both equipped with three-phase windings, the motor enables contactless energy to be transferred from the stator to the mover. Thus, when a doubly-fed linea...Because the mover and stator of a doubly-fed linear motor are both equipped with three-phase windings, the motor enables contactless energy to be transferred from the stator to the mover. Thus, when a doubly-fed linear motor is used in the linear driving system of trains, neither an overhead line nor a third rail is needed. However, the doubly- fed motor will lead to more severe thrust fluctuation than the unilateral motors. In order to overcome this shortcoming, the thrust fluctuation of the doubly-fed motor should be analyzed. In this paper, an expression for motor thrust is derived. It points out that the slot effect caused by the slotted structure is the main reason for the increase of thrust fluctuation. The method of adopting unequal pole pitch and unequal slot numbers per pole per phase of stator and mover, is proposed to weaken the slot effect when designing the motor slot parameters. Three different motor models are simulated by ANSOFT. The proposed method results in a motor thrust fluctuation coefficient of 8.4%, compared to 49.4% for the conventional method. Therefore, the motor's thrust fluctuation is effectively suppressed by the proposed method.展开更多
文摘Objective: The aim of our study was to investigate the impact of abdominal hypo-fraction irradiation on liver damage in rats so as to provide a reference for its clinical application. Methods: A total of 100 Wistar rats were equally randomized to five groups as control, 4 Gy, 6 Gy, 8 Gy and 12 Gy group, and the corresponding fractionated doses were offered. Liver functions were examined at the 2nd, 4th, 6th, 8th and 10th week after irradiation. Morphological changes were observed by HE staining. Expressions of Bcl-2 and Bax were examined by immunohistochemical technique. Results: In all irradiation groups, hepatocellular swell, degeneration, necrosis and even hepatic fibrosis could be seen. The differences of the liver coefficient, Glutamyl pyruvic transaminase (GPT), Glutamyl oxaloacetic transaminase (GOT) were significant among the groups and different time points (F = 11.833-781.972, F = 20.857-264.692, P < 0.001). Expressions of Bcl-2 and Bax were significantly different between each group (F = 211.607, 116.577; P < 0. 001), and between each time point (F = 54.083, 68.749; P < 0. 001). Conclusion: Compare with conventional fraction, abdominal hypo-fraction irradiation may cause radiation damage to rat liver, being dose-and-time dependent. Up-regulation of activating apoptosis protein Bax and down-regulation of inhibiting apoptosis protein Bcl-2 may involve in the process.
基金Supported by "Hope for the West" Fund of the Chinese Academy of Science (No. XB 980604)
文摘The low dose effects induced by carbon ions on Chinese hamster V79 cells and murine melanoma B16 cells were investigated in this paper. Both cell lines were divided into four groups for irradiation: (1) control, (2) 0.02 Gy or 0.05 Gy(D1), (3) 1 Gy(D2), (4) D1+D2. The survivors and micronuclei were studied as biological endpoints. The results of group (1) and group (2) showed that there were no obvious differences on micronucleus frequency but there were significant increases when irradiation dose was 0.02Gy on colony formation efficiency. Although low dose ion irradiation could not contribute to DNA damages, it could enhance the colony formation efficiency. In the study of group (3) and (4), when the ion dose was 0.02 Gy, there were evident increases on surviving fraction and decreases on micronucleus frequency, but there were no statistical changes on these endpoints when the ion dose was 0.05Gy. This meant that high LET radiation could induce the adaptive response of cultured cells, furthermore, in the range of inducing ion dose , low dose irradiation was more profitable than high dose one.
基金supported by Universiti Kebangsaan Malaysia and Lynas Advanced Material Plant under Grant Numbers GGPM-2017-084 and ST-2017-012,respectively
文摘In this study, the activity concentrations of ^(226)Ra,^(232)Th,^(222)Rn, and ^(40)K, emanation fractions(P),equilibrium equivalent concentration(EEC), and mass exhalation rates(E_m) of radon released from building materials used in Malaysia were studied using gamma-ray spectrometer with HPGe detector. Radiological parameters[activity concentration index(ACI), indoor air-absorbed dose rate(D_(in)), annual effective dose(AED_(in)) from external and internal(E_(Rn)), soft tissues(H_(ST)) and lung(H_L), and effective dose equivalent(H_(eff))] were estimated to evaluate radiological hazards due to the use of these building materials: sand, cement, gravel, bricks, tiles, fly ash, white cement, and ceramic raw materials. The measured P, EEC,and E_m vary from 10 to 30%, 0.9 to 22 Bq m^(-3), and 33 to 674 mBq h^(-1) kg^(-1), respectively, while the calculated ACI and AED_(in) vary from 0.1 ± 0.01 to 2.1 ± 0.1 and 0.1 ± 0.01 to 2.4 ± 0.6 mSv y^(-1), respectively. On the other hand, the internal annual effective dose ranges from 0.1 to 1.4 mSv y^(-1). The estimated radiological risk parameters were below the recommended maximum values, and radiological hazards associated with building materials under investigation are therefore negligible.
文摘Because the mover and stator of a doubly-fed linear motor are both equipped with three-phase windings, the motor enables contactless energy to be transferred from the stator to the mover. Thus, when a doubly-fed linear motor is used in the linear driving system of trains, neither an overhead line nor a third rail is needed. However, the doubly- fed motor will lead to more severe thrust fluctuation than the unilateral motors. In order to overcome this shortcoming, the thrust fluctuation of the doubly-fed motor should be analyzed. In this paper, an expression for motor thrust is derived. It points out that the slot effect caused by the slotted structure is the main reason for the increase of thrust fluctuation. The method of adopting unequal pole pitch and unequal slot numbers per pole per phase of stator and mover, is proposed to weaken the slot effect when designing the motor slot parameters. Three different motor models are simulated by ANSOFT. The proposed method results in a motor thrust fluctuation coefficient of 8.4%, compared to 49.4% for the conventional method. Therefore, the motor's thrust fluctuation is effectively suppressed by the proposed method.