期刊文献+
共找到25,635篇文章
< 1 2 250 >
每页显示 20 50 100
Clinical Effectiveness of the Plate Screw Internal Fixation Technique in the Treatment of Patients with Traumatic Fractures of Long Bones in the Lower Extremities
1
作者 Yong Cai 《Proceedings of Anticancer Research》 2024年第3期115-120,共6页
Objective: To investigate the effectiveness of the plate screw internal fixation technique on the clinical outcomes of patients with traumatic fractures of long bones in the lower extremities. Methods: From January 20... Objective: To investigate the effectiveness of the plate screw internal fixation technique on the clinical outcomes of patients with traumatic fractures of long bones in the lower extremities. Methods: From January 2022 to December 2023, 70 patients with traumatic fractures of long bones in the lower extremities were admitted to the hospital and randomly divided into two groups: the control group and the observation group, each consisting of 35 cases. The control group underwent traditional closed interlocking intramedullary nailing, while the observation group received internal fixation with steel plates and screws. Relevant surgical indicators, treatment effectiveness, and postoperative complication rates were compared between the two groups. Results: The observation group exhibited significantly short surgical duration (80.65 ± 5.01 vs. 88.36 ± 5.26 minutes), fracture healing time (13.27 ± 0.32 vs. 15.52 ± 0.48 weeks), and hospitalization days (10.49 ± 1.13 vs. 16.57 ± 1.15 days) compared to the control group (P = 0.000). The effective treatment rate was significantly higher in the observation group (29/82.86%) than in the control group (21/60.00%), with a significant difference observed (χ2 = 4.480, P = 0.034). Additionally, the complication rate in the observation group (2/5.71%) was significantly lower than that in the control group (8/22.86%), with a correlated difference (χ2 = 4.200, P = 0.040). Conclusion: The plate screw internal fixation technique demonstrates significant clinical efficacy in treating traumatic fractures of long bones in the lower extremities. It improves the healing rate, reduces complications, and represents a safe and effective treatment strategy worthy of widespread use and application. 展开更多
关键词 Plate screw internal fixation technique Traumatic fractures Long bones in the lower extremities EFFECTIVENESS
下载PDF
Meta-analysis of the efficacy of volar plate internal fixation versus closed reduction and external fixation in the treatment of adult distal radius fractures
2
作者 CHEN Jian-ge ZHANG Hai-ning +4 位作者 ZHAO Hong-zhou LIU Ming-jun XING Jia-hui WANG Ping WANG Wei-min 《Journal of Hainan Medical University》 CAS 2023年第19期44-56,共13页
Objective:To compare the efficacy of open reduction and volar locking plate internal fixation with closed reduction and external fixation in the treatment of distal radius fractures by using meta analysis.Methods:The ... Objective:To compare the efficacy of open reduction and volar locking plate internal fixation with closed reduction and external fixation in the treatment of distal radius fractures by using meta analysis.Methods:The databases of CNKI,Wanfang,Weipu,Chinese biomedical literature,Pubmed,Embase,and Cochrane Library were retrieved,and the randomized controlled studies that directly compared the efficacy of plate internal fixation and closed reduction external fixation in the treatment of distal radius fractures published publicly from the establishment of the database to April 2023 were collected.The two researchers independently screened the retrieved literature according to the inclusion and exclusion criteria,extracted data,used Cochrane risk bias assessment tool for quality assessment,and used RevMan 5.4 software for meta analysis.Results:A total of 10 randomized controlled trials were included,all of which were in English.There were 1042 patients in total,and 9 of them were rated as low risk.Meta analysis results showed that one year after the treatment of distal radius fracture with volar locking plate internal fixation,DASH score[MD=-5.64,95%CI(-7.21,-4.06),P<0.00001];One year later,PRWE score[MD=-5.90,95%CI(-8.88,-2.92),P=0.001];Palm flexion[MD=5.92,95%CI(1.29,10.55),P=0.01];Pronation[MD=2.48,95%CI(0.59,4.36),P=0.01];Postrotation[MD=4.73,95%CI(2.15,7.31),P=0.0003];Grip strength[MD=0.61,95%CI(0.12,1.10),P=0.02];palmar tilt angle[MD=9.84,95%CI(5.66,14.02),P<0.00001];Radial inclination[MD=4.33,95%CI(2.97,5.69),P<0.00001]was superior to closed reduction plaster or splint external fixation.One year later,the European Five dimensional Health Scale(EQ-5D-5L)score[MD=0.02,95%CI(-0.01,0.05),P=0.27];Back extension[MD=2.22,95%CI(-4.15,8.59),P=0.49];Ulnar deviation[MD=3.49,95%CI(-0.80,7.78),P=0.11];Radial deviation[MD=2.05,95%CI(-2.39,6.50),P=0.37];Ulnar variance[MD=-1.14,95%CI(-3.16,0.88),P=0.27];There was no significant difference in complications[MD=0.77,95%CI(0.54,1.10),P=0.16](P>0.05).Conclusion:Based on the current clinical data,internal fixation with volar locking plate is more conducive to mid-term DASH score and grip strength recovery than closed reduction plaster or splint external fixation,but there is no significant difference in the quality of life and complications of patients.For adult distal radius fractures,surgical indications should be carefully grasped,and non operative treatment should be given priority. 展开更多
关键词 Volar plate internal fixation Closed reduction External fixation PLASTER SPLINT Distal radius fracture Meta analysis
下载PDF
Open reduction and internal fixation for radial head fractures: A prospective observational study 被引量:4
3
作者 Imran Khan Mangi Arslan Ahmed Abro +4 位作者 Muhammad Naveed Memon Shahjahan Siyal Naveed Khan Nouman Memon Muhammad Kazim Rahim Najjad 《Journal of Acute Disease》 2020年第4期166-169,共4页
Objective: To evaluate the effect of open reduction and internal fixation on radial head fracture and assess the post-operative function. Methods: This prospective observational study was conducted from June 2016 to J... Objective: To evaluate the effect of open reduction and internal fixation on radial head fracture and assess the post-operative function. Methods: This prospective observational study was conducted from June 2016 to July 2017 at Liaquat National Hospital and Medical College, Karachi. Altogether, 28 patients with radial head and neck fractures were enrolled in our study. These patients were admitted to the hospital and their fractures were fixed with open reduction and internal fixation. Baseline information of the patients was collected, and patient-rated elbow evaluation scores were calculated. Results: Out of the 28 patients, 21 were male and 7 were female. Besides, 16 fractures were on the right side and 12 were on the left side and 17 involving the dominant hands. In addition, 8 patients had Mason type Ⅱ fracture and 20 had Mason type Ⅲ fracture. The mean age of patients was (31.0 ± 8.0) years, and the mean follow-up is (1.2 ± 0.5) years. The mean average patient-rated elbow evaluation scores were (27.64 ± 1.60) at 1-year follow-up. Conclusions:The majority of the patients who had radial head fractures and treated by open reduction and internal fixation have attained an excellent range of motion postoperatively. 展开更多
关键词 Radial head fractures Open reduction and internal fixation Functional outcome
下载PDF
THE SYNTHESIS AND CHARACTERIZATION OFPOLY-L-LACTIDE USED FOR THE INTERNALFIXATION OF BONE FRACTURE 被引量:2
4
作者 Zhang Zhengpu Lu ge +1 位作者 Wu Zhizhong He Binglin 《Chinese Journal of Reactive Polymers》 1998年第2期1-6,共6页
A high Mw of PLLA was synthesized, it intended to be used in the manufacture ofbioabsorbable screw applied in bone fracture internal fixation. The optical reactionconditions have been discussed.
关键词 Poly-L-lactic acid BIOABSORBABLE Bone fracture internal fixation
下载PDF
Modified Closed Reduction and Percutaneous Kirschner Wires Internal Fixation for Treatment of Supracondylar Humerus Fractures in Children 被引量:5
5
作者 Shu-bin WANG Bin-hui LIN +4 位作者 Wei LIU Guo-jun WEI Zong-guang LI Nai-chun YU Guang-rong JI 《Current Medical Science》 2021年第4期777-781,共5页
Objective Supracondylar humerus fractures are the most frequent fractures of the paediatric elbow.The present study introduced a modified surgical procedure for treatment of supracondylar humerus fractures in children... Objective Supracondylar humerus fractures are the most frequent fractures of the paediatric elbow.The present study introduced a modified surgical procedure for treatment of supracondylar humerus fractures in children.Methods From February 2015 to August 2019,73 patients with Gartland’s type II and III supracondylar fractures were treated with this modified method.Totally,68 of all patients were followed up for 3–12 months(mean 8.25 months).The evaluation results included fracture nonunion,ulnar nerve injury,pin track infection,carrying angle and elbow joint Flynn score.Results The results showed that bone union was observed in all children,one case had an iatrogenic ulnar nerve injury,and the symptoms were completely relieved in 4 months after removing of the medial-side pin.All children had no cubitus varus deformity and no pin track infection,and the rate of satisfactory results according to Flynn’s criteria score was 100%.Conclusion The modified closed reduction and Kirschner wires internal fixation could effectively reduce the rate of open reduction,the risk of iatrogenic ulnar nerve injury,and the incidence of cubitus varus deformity in treatment of supracondylar humerus fractures in children. 展开更多
关键词 supracondylar humerus fractures closed reduction Kirschner wires internal fixation surgical method
下载PDF
关于Rigid Internal Fixation一词译法和应用的说明
6
作者 顾晓明 《中国口腔颌面外科杂志》 CAS 2004年第1期21-21,共1页
关键词 igid internal fixation RIF 内固定 口腔颌面部 力学设计
下载PDF
Comparative Dimensional and Microscopic Analysis of the Strength and Hardness of Internal Fixation Plates
7
作者 Victor Tieghi Neto Eduardo Stedile Fiamoncini +3 位作者 Matheus Falsarelli Ferreira Danilo Luiz Flumignan Luis Geraldo Vaz Eduardo Sanches Gonçales 《Open Journal of Stomatology》 2020年第10期310-320,共11页
The fixation stability achieved with the use of plates and screws in oral and maxillofacial surgery is a decisive factor in treatment success. The mechanical and structural properties of the internal fixation material... The fixation stability achieved with the use of plates and screws in oral and maxillofacial surgery is a decisive factor in treatment success. The mechanical and structural properties of the internal fixation materials have direct influence on the dimensional stability and resistance of a fixation system, thus influencing treatment outcomes. This study proposed to analyze the dimensional and resistance patterns of titanium plates used for obtaining stable fix<span style="font-family:Verdana;">ation in orthognathic surgery and craniofacial trauma. For this study, 30 conventional 2.0</span><span style="font-family:Verdana;"> </span><span style="font-family:Verdana;">mm straight four hole plates with bridge from three brands commercialized in Brazil, were subjected to macroscopic, microscopic, strength and hardness analysis. The dimensional measurements were performed using a digital caliper. Energy-dispersive X-ray spectroscopy analysis was performed by scanning electron microscopy to analyze the chemical composition of the samples. The mechanical resistance tests were performed with a universal testing machine. The samples were then submitted to Vickers hardness analysis, complying with the standards of ASTM E92. The data collected from the dimensional study was submitted to statistical analysis of the coefficient of variation, while the values obtained during the mechanical tests were analyzed by variance (ANOVA) and Tukey’s test (p <</span><span style="font-family:Verdana;"> </span><span style="font-family:Verdana;">0.05). The sample groups presented different performances in resistance, hardness, size and surface, even though they were reported to be chemically similar compounds that allowed us to conclude the plates from Group 2 were more resistant than groups 1 and 3.</span> 展开更多
关键词 Fracture fixation internal Biocompatible Materials Compressive Strength
下载PDF
Observation on the Efficacy of Autologous Blood Transfusion Combined with Controlled Hypotension in Patients with Spinal Internal Fixation during the Outbreak of New Coronavirus Pneumonia in Western Guangxi (in Guixi)
8
作者 Chengkua Huang Guosheng Su +3 位作者 Yong Zhao Chunxian Lu Sheng Nong Xiaohua Huang 《Open Journal of Blood Diseases》 2021年第1期15-23,共9页
<strong>Objective: </strong>To explore the therapeutic effect of autologous blood reinfusion combined with controlled hypotension in surgical spinal fixation during the outbreak of COVID-19. <strong>... <strong>Objective: </strong>To explore the therapeutic effect of autologous blood reinfusion combined with controlled hypotension in surgical spinal fixation during the outbreak of COVID-19. <strong>Methods: </strong>30 patients with spinal internal fixation autologous blood transfusion combined with controlled hypotension were selected as the subjects during the epidemic period from December 2019 to June 2020 in our hospital and during the operation, on the basis of routine blood pressure reduction, the American Haemonetice Corporation autologous blood continuous reinfusion system was used to infuse the blood recovered during the operation to the patient through filtration and other procedures. <strong>Results:</strong> 30 patients had no complications such as fever and hemolysis;And after the operation, the tube was dialed according to the drainage volume, the cervical thoracic and lumbar brace was customized, and the patient walked on the ground for one week;After no abnormalities, the patient was discharged. Intraoperative comparison of white blood cells (WBC), red blood cells (RBC), red blood cell pressure (HCT), hemoglobin (HGB), and coagulation time (PT) of patients with autologous blood before and after transfusion showed statistically significant differences before and after surgery (P < 0.001). <strong>Conclusion:</strong> During the new coronavirus pneumonia epidemic, the internal fixation of spinal surgery used a recovery machine to collect intraoperative blood for reinfusion. Intraoperative antihypertensive drugs were used to control blood pressure within a certain safe range. The postoperative clinical observation effect was significant and safe;especially at present the clinical significance during the epidemic was significant. 展开更多
关键词 New Coronavirus Pneumonia Spinal internal fixation Surgery Autologous Blood Reinfusion Controlled Hypotension Curative Effect
下载PDF
Chinese traditional medicine rehabilitative treatment of femoral neck fracture after screw thread needle internal fixation
9
作者 高广升 李凤辉 《中国组织工程研究与临床康复》 CAS CSCD 2001年第24期154-155,共2页
关键词 Chinese traditional medicine rehabilitative treatment of femoral neck fracture after screw thread needle internal fixation TIME
下载PDF
MIPPO technique and LCP internal fixation for open tibial shaft fractures
10
作者 邹海兵 《外科研究与新技术》 2011年第2期107-107,共1页
Objective To explore the efficacy of minimally invasive percutaneous plate osteosynthesis (MIPPO) technique and locking compression plate (LCP) for open tibial shaft fractures.Methods From March 2005 to May 2009,16 ca... Objective To explore the efficacy of minimally invasive percutaneous plate osteosynthesis (MIPPO) technique and locking compression plate (LCP) for open tibial shaft fractures.Methods From March 2005 to May 2009,16 cases with open tibial 展开更多
关键词 MIPPO technique and LCP internal fixation for open tibial shaft fractures LCP
下载PDF
Dynamic external fixator combined with limited internal fixation for Pilon reactures
11
作者 李灿杨 《外科研究与新技术》 2011年第2期109-109,共1页
Objective To evaluate effects of manipulative reduction,dynamic external fixator combined with limited internal fixation for the treatment of Pilon fractures.Methods From January 2007 to June 2009,manipulative reducti... Objective To evaluate effects of manipulative reduction,dynamic external fixator combined with limited internal fixation for the treatment of Pilon fractures.Methods From January 2007 to June 2009,manipulative reduction,dynamic external 展开更多
关键词 Dynamic external fixator combined with limited internal fixation for Pilon reactures
下载PDF
Application of internal fixation of steel-wire limited loop in early Achilles tendon rupture 被引量:10
12
作者 Zhe Chen Jia-Sen Wei +3 位作者 Zhao-Yang Hou Jiong Hu Yan-Guang Cao Qi-Xin Chen 《Asian Pacific Journal of Tropical Medicine》 SCIE CAS 2013年第11期902-907,共6页
Objective:To explore the clinical effect and safety of internal fixation of steel-wire limited loop in early Achilles tendon rupture.Methods:Seventy-six patients respectively with early transected and avulsed types of... Objective:To explore the clinical effect and safety of internal fixation of steel-wire limited loop in early Achilles tendon rupture.Methods:Seventy-six patients respectively with early transected and avulsed types of Achilles tendon rupture were selected and treated with internal fixation of steel-wire limited loop.The patients began to take exercise for their lower limbs through continous passive motion as early as possible after surgical repair,and the loops were removed after 3-5 months.Six months later,the condition of complications including Achilles tendon re-rupture,wound fistula,wound infection and skin necrosis,cutaneous sensation in sural nerve dominance region,time back to preinjury work or learning as well as time to physical activities were observed.One year later,the therapeutic effect was evaluated,and the maximum circumferences of bilateral legs and raptured plane circumferences of Achilles tendon were measured.Results:The wound of all patients healed well,no complications like Achilles tendon re-rupture,wound fistula,wound infection and skin necrosis occured,and the cutaneous sensation in sural nerve dominance region was normal.The mean time back to preinjury work or learning as well as to pysical activities of all patients were respectively 10 and 22 weeks.Seventy out of 76 patients(92.1%) achieved an excellent effect,and 6(7.9%) good effect.The excellent and good rate came up to 100%.The maximum circumference in the affected leg decreased to 2 mm averagely compared with the offside,while the ruptured plane circumferences of Achilles tendon in the affected side increased to 2.2 mm compared with the offside.Conclusions:Kor early Achilles tendon rupture,internal fixation of steel-wire limited loop can recover the ankle function better,return to the preinjury state in the shortest lime,and has few complications. 展开更多
关键词 ACHILLES TENDON rupture Steel-wire LIMITED LOOP internal fixation ANKLE function
下载PDF
Association between anterior internal fixation systems and post-operative lateral angulation in thoracolumbar fractures
13
作者 马立泰 《外科研究与新技术》 2011年第2期106-106,共1页
Objective To explore the effects of the anterior internal fixation systems on the post-operative lateral angulation in treatment of thoracolumbar fractures.Methods A retrospective study was done to analyze the 172 pat... Objective To explore the effects of the anterior internal fixation systems on the post-operative lateral angulation in treatment of thoracolumbar fractures.Methods A retrospective study was done to analyze the 172 patients who had 展开更多
关键词 Association between anterior internal fixation systems and post-operative lateral angulation in thoracolumbar fractures
下载PDF
The application of C1-C2 pedicle screw internal fixation on the upper cervical diseases of children
14
作者 夏虹 《外科研究与新技术》 2011年第2期80-80,共1页
Objective To report five cases of puerile (【9 years) atlantoaxial instability which underwent C1-C2 pedicle screw internal fixation by posterior approach,and to introduce the surgical technique and the key point
关键词 The application of C1-C2 pedicle screw internal fixation on the upper cervical diseases of children
下载PDF
Clinical application of improved 2D computer-assisted fluoroscopic navigation through simulating a 3D vertebrae image to guide pedicle screw internal fixation
15
作者 刘恩志 《外科研究与新技术》 2011年第2期94-94,共1页
Objective To study the effect of using improved 2D computer-assisted fluoroscopic navigation through simulating 3D vertebrae image to guide pedicle screw internal fixation.Methods Posterior pedicle screw internal fixa... Objective To study the effect of using improved 2D computer-assisted fluoroscopic navigation through simulating 3D vertebrae image to guide pedicle screw internal fixation.Methods Posterior pedicle screw internal fixation,distraction 展开更多
关键词 Clinical application of improved 2D computer-assisted fluoroscopic navigation through simulating a 3D vertebrae image to guide pedicle screw internal fixation
下载PDF
Usage of buttress plate internal fixation associated with autografting of fibula and iliac bone for the treatment of distal femoral C_3 type fracture
16
作者 李衡 《外科研究与新技术》 2005年第3期176-177,共2页
To assess the effect of using buttress plate associated with antografting of fibula and iliac bone for the treatment of distal femoral C3 type fracture.Methods Seventeen cases of distal femoral C3 type fracture usin... To assess the effect of using buttress plate associated with antografting of fibula and iliac bone for the treatment of distal femoral C3 type fracture.Methods Seventeen cases of distal femoral C3 type fracture using buttress plate associated with antografting of fibula and iliac bone were analyzed retrospectively.Results All cases were followed up for an average of 24 months(8~55 months).The average time of octets bridge forming were 4 months(3~5 months) while the average time for bone union were 8 months (6~14 months).According to Shelbourne rating system,result of all 18 cases were excellent and no malunion,infection were found.Conclusion Buttress plate associated with antografting of fibula and iliac bone is an effective alternative for the treatment of distal femoral C3 type fracture.It can provide more stable fixation to the bone and earlier functional exercises can be achieved.5 refs,3 figs,1 tab. 展开更多
关键词 Usage of buttress plate internal fixation associated with autografting of fibula and iliac bone for the treatment of distal femoral C3 type fracture
下载PDF
Comparative study of various internal fixation methods for treating patellar fractures by three-dimensional photoelasticity 被引量:2
17
作者 许硕贵 苏佳灿 +4 位作者 张春才 曾伟明 顾绍德 张林春 方如华 《Journal of Medical Colleges of PLA(China)》 CAS 2003年第6期384-387,共4页
Objective: To compare the biomechanical basis of 3 different internal fixation methods: nitinol patellar concentrator (NT-PC), tension band and wire circle in treating patellar fractures. Methods: The epoxy resin thre... Objective: To compare the biomechanical basis of 3 different internal fixation methods: nitinol patellar concentrator (NT-PC), tension band and wire circle in treating patellar fractures. Methods: The epoxy resin three dimensional photoelasticity patellar models were made by precise moulding, and were fixated by nitinol patellar concentrator (NT-PC), tension band and wire circle respectively. The patellar models with frozen stress stripes were put into the polarized light field and the stress distributions were compared. As for the model fixated by NT-PC, by dividing layer, photographing and tracing, we used the iterative method to calculate the stress value of every internal node of the epoxy resin patellar model, and the character of stress was analyzed. Results: An overall stress field was yielded when the patellar model was fixated by NT-PC, and the stripes were more than that of tension band model and wire circle model, which have only few stress stripes in the fixated layers. Further analysis indicated that there were continuous fixated stresses in the facies articularis and distal pole of patella, and the character of stresses produced by NT-PC were mainly in longitudinal direction, then in transverse direction. The shearing stresses were small. Conclusion: The initiative and continuous memorial stress of NT-PC and its overall stress distribution character are the essence of NT-PC distinguished with tension band and wire circle in treating patellar fractures. The stress character produced by NT-PC is good for the stability of fracture site and prompts fracture healing. 展开更多
关键词 internal fixation patellar fracture PHOTOELASTICITY STRESS nitinol patellar concentrator
下载PDF
The Use of Calcaneal Anatomic Plate in Arthroscopically-assisted Open Reduction and Internal Fixation of Intra-articular Calcaneal Fractures 被引量:1
18
作者 王洪 张青松 +1 位作者 段德宇 严力军 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2006年第3期319-321,共3页
To discuss and evaluate the method and effect of using calcaneal anatomic plate in treatment of intra-articular fractures of the calcaneus with assistant of arthroscope, 86 intra-articular fractures of the calcaneus i... To discuss and evaluate the method and effect of using calcaneal anatomic plate in treatment of intra-articular fractures of the calcaneus with assistant of arthroscope, 86 intra-articular fractures of the calcaneus in 78 patients were reduced by open reduction, and rigid fixation was made with calcaneal anatomic plate under assistant of arthroscope. The average follow-up duration was 18 months (range 12-30 months). The effect of treatment was evaluated according to AOFAS and X-ray before and after operation. The results showed that 86 patients have obtained satisfactory reduction according to X-ray, and there was significant difference before and after operation (P〈0. 01), the total excellent and fine rate was 91.86%. Treating intra-articular fractures of the calcaneus with calcaneal anatomic plate under arthroscope may provide more chance to achieve anatomical reconstruction, which can lead to satisfied recovery of function and few complication. 展开更多
关键词 Fracture of Calcaneus Calcaneal Anatomic Plate ARTHROSCOPE internal fixation
下载PDF
Functional Outcomes of Traumatic Complex Acetabulum Fractures with Open Reduction and Internal Fixation: 200 Cases 被引量:3
19
作者 Keykhosro Mardanpour Mahtab Rahbar +2 位作者 Maryam Rahbar Nyosha Mardanpour Sourena Mardanpour 《Open Journal of Orthopedics》 2016年第12期363-377,共15页
Objective: Acetabular fractures are common injuries in Iran. We assess the functional outcome of open reduction and internal fixation management of displaced Complex acetabular fractures. Materials and Methods: We ana... Objective: Acetabular fractures are common injuries in Iran. We assess the functional outcome of open reduction and internal fixation management of displaced Complex acetabular fractures. Materials and Methods: We analyzed a case series of patients with open reduction and internal fixation (ORIF) for complex acetabular fractures. Two hundred patients (132 men, 68 women) in four age groups including with a mean age of 43.39 ± 6.18 years (range 20 - 59 years) and a mean follow-up of 82.34 ± 12.48 months (range 18 - 109 months) met the inclusion criteria. Functional outcome at final follow-up was graded assessed according to Harris score. Factors affecting were defined. Results: Anatomic reduction was achieved in 192 hips, imperfect in 8 and poor in none. Radiological outcome revealed excellent results in 128 (64%) hips, good in eight, fair in five and none in poor. Harris score were excellent in 139 (69.5%) hips, good in 43 (21.5%) and fair in 18 (9%) and poor in none. The anatomical reduction results had a favorable final functional outcome. (0.003) However, BMI (P Conclusion: Optimal functional and radiological outcomes have been achieved with anatomic postoperative reduction. Also experience of specialist, on time surgery and good recovery lead to receiving excellent functional outcome with at least complications. 展开更多
关键词 Complex Acetabular Fracture internal fixation Open Reduction OUTCOME
下载PDF
Triple Arthrodesis with Internal and External Fixation: Technique Paper 被引量:1
20
作者 Luis E. Marin Randy Semma Nisha Bala Krishnan 《Surgical Science》 2014年第4期183-192,共10页
Background: The triple arthrodesis was described early by Myerson in 1923 and has been the gold standard surgical procedure for various conditions with the goal to reduce pain, improve deformity and facilitate functio... Background: The triple arthrodesis was described early by Myerson in 1923 and has been the gold standard surgical procedure for various conditions with the goal to reduce pain, improve deformity and facilitate function. Methods: The procedure consists of fusion of the subtalar joint, talonavicular joint and calcaneocuboid joint [1]. The procedure is traditionally done with internal fixation, however, Marinet al. has shown it to be performed with external fixation [2]. Dr. Marin and the associates have developed an alternative technique to perform a triple arthrodesis using internal and external fixation. This paper describes a step-by-step technique to perform a triple arthrodesis with both internal and external fixation. It will demonstrate the use of the prefabricated arches on the footplate for more precise and accurate placement of transosseous wires using arch-wire technique [3]. Results/Conclusion: We believe this technique will not only help increase the ability to achieve fusion with a less chance of non-union, but may also decrease healing time, which may allow patients to be mobile from the first week post-operatively and may diminish the risks associated with being non-weightbearing. 展开更多
关键词 Triple ARTHRODESIS Podiatric Medicine Surgery External fixation internal fixation WALKING TECHNIQUE PODIATRY
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部