Frame resolution and physical layer (PHY) protocol type detection are the basis of research and development of intrusion prevention systems for IEEE 802.11 wireless network. Aiming at the problems which cannot be solv...Frame resolution and physical layer (PHY) protocol type detection are the basis of research and development of intrusion prevention systems for IEEE 802.11 wireless network. Aiming at the problems which cannot be solved by the specifications export, this paper proposed a MAC frame analytical method and a PHY protocol type detection algorithm based on parsing the IEEE 802.11packets captured by the library Libpcap. The packet structure and the length of the frame preamble (18 or 26 bytes) are presented. Then the methods of transforming byte-order and resolving sub-fields are given. A detection algorithm of PHY protocol type is proposed based on the experiments and examples are given to verify these methods. This work can be a reference for the R & D related to link layer frame analysis.展开更多
In this paper, we investigate the entanglement dynamics of a two-qubit entangled state coupled with its noisy envi- ronment, and plan to utilize weak measurement and quantum reversal measurement to study the entanglem...In this paper, we investigate the entanglement dynamics of a two-qubit entangled state coupled with its noisy envi- ronment, and plan to utilize weak measurement and quantum reversal measurement to study the entanglement dynamics under different decoherence channels in noninertial frames. Through the calculations and analyses, it is shown that the weak measurement can prevent entanglement from coupling to the amplitude damping channel, while the system is under the phase damping and flip channels. This protection protocol cannot prevent entanglement but will accelerate the death of entanglement. In addition, if the system is in the noninertial reference frame, then the effect of weak measurement will be weakened for the amplitude damping channel. Nevertheless, for other decoherence channels, the Unruh effect does not affect the quantum weak measurement, the only exception is that the maximum value of entanglement is reduced to √2/2 of the original value in the inertial frames.展开更多
文摘Frame resolution and physical layer (PHY) protocol type detection are the basis of research and development of intrusion prevention systems for IEEE 802.11 wireless network. Aiming at the problems which cannot be solved by the specifications export, this paper proposed a MAC frame analytical method and a PHY protocol type detection algorithm based on parsing the IEEE 802.11packets captured by the library Libpcap. The packet structure and the length of the frame preamble (18 or 26 bytes) are presented. Then the methods of transforming byte-order and resolving sub-fields are given. A detection algorithm of PHY protocol type is proposed based on the experiments and examples are given to verify these methods. This work can be a reference for the R & D related to link layer frame analysis.
基金Project supported by the National Natural Science Foundation of China (Grant Nos.11074002 and 61275119)the Doctoral Science Foundation of the Ministry of Education of China (Grant No.20103401110003)the Natural Science Research Project of the Education Department of Anhui Province,China (Grant Nos.KJ2013A205,KJ2011ZD07,and KJ2012Z309)
文摘In this paper, we investigate the entanglement dynamics of a two-qubit entangled state coupled with its noisy envi- ronment, and plan to utilize weak measurement and quantum reversal measurement to study the entanglement dynamics under different decoherence channels in noninertial frames. Through the calculations and analyses, it is shown that the weak measurement can prevent entanglement from coupling to the amplitude damping channel, while the system is under the phase damping and flip channels. This protection protocol cannot prevent entanglement but will accelerate the death of entanglement. In addition, if the system is in the noninertial reference frame, then the effect of weak measurement will be weakened for the amplitude damping channel. Nevertheless, for other decoherence channels, the Unruh effect does not affect the quantum weak measurement, the only exception is that the maximum value of entanglement is reduced to √2/2 of the original value in the inertial frames.