期刊文献+
共找到504篇文章
< 1 2 26 >
每页显示 20 50 100
Should We Pay More Attention to Endotracheal Tube Fixation during Anesthesia—Surveys from Chinese Anesthesiologists for Endotracheal Tube Fixation and Endotracheal Tube Displacement in 2014 and 2020
1
作者 Dongxue Li Tongfeng Luo +2 位作者 Chuling Liu Xi Hong Sanqing Jin 《Open Journal of Anesthesiology》 2021年第8期243-258,共16页
<b>Background:</b> Displacement of endotracheal tube (ETT) can result in endobronchial intubation and accidental extubation that severely threatens safety of surgical patients. However, few surveys have in... <b>Background:</b> Displacement of endotracheal tube (ETT) can result in endobronchial intubation and accidental extubation that severely threatens safety of surgical patients. However, few surveys have investigated intraoperative ETT displacement experienced by anesthesiologists. The objective of these surveys was to investigate ETT fixation method and ETT displacement during general anesthesia experienced by anesthesiologists in China in 2014 and 2020. <b>Methods:</b> A questionnaire was designed with twenty questions and randomly distributed to anesthesiologists in two survey methods. In 2014, we collected responses from anesthesiologists who participated in the 22nd annual meeting of the Chinese Society of Anesthesiology in a face-to-face setting;in 2020, anesthesiologists from twenty-eight provinces completed the questionnaire through an online questionnaire survey platform. Differences in the responses from the anesthesiologists in 2014 and 2020 were assessed with a chi-square test. <b>Results:</b> In total, 568 questionnaires were collected, of which 541 questionnaires were valid (valid response rate 95.2%). A majority of the respondents (65.6%) had experienced ETT displacement, and 4.3% of respondents had experienced serious complications due to ETT displacement. Three hundred and twenty-nine respondents (60.8%) fixed the ETT with adhesive tape in the shape of the letter X. A majority of respondents considered the influence of surgical site, body position (97.8% of all respondents), and age (77.1% of all respondents) on fixing the ETT. Adhesive tape was the most commonly used material to fix the ETT (90.4% of the respondents). <b>Conclusion:</b> During clinical anesthesia, a majority of anesthesiologists experienced ETT displacement that can result in serious consequences. Therefore, the management of ETT should be a priority during the operation. 展开更多
关键词 ANESTHESIA Endotracheal tube displacement FIXATION Questionnaires
下载PDF
Deterministic Displacement and Scaling Structure of Viscous Fingering with Dispersion Effect in Random Porous Media
2
作者 TIAN Ju-Ping YAO Kai-Lun 《Chinese Physics Letters》 SCIE CAS CSCD 2001年第3期373-375,共3页
A model of random porous media degradation via several fluid displacing,freezing and thawing cycles is investigated.The fluid transport is based on the deterministic method with dispersion effect.The research shows th... A model of random porous media degradation via several fluid displacing,freezing and thawing cycles is investigated.The fluid transport is based on the deterministic method with dispersion effect.The research shows that the topology and the geometry of the porous media have a strong effect on displacement processes.The distribution of throat size N(r)after displacement but before freezing damage shows that the major change,after successive cycles,happens at throat radius r>0.9.The distribution of velocities normal to the interface of viscous fingering in percolation cluster is also studied.When iterations n≥10,the scaling function distribution is very sharp. 展开更多
关键词 freezing displacement POROUS
下载PDF
THE PHENOMENON ON COLLAPSIBLE TUBE DISPLACEMENT OSCILLATION AND ITS THEORETICAL ANALYSIS
3
作者 Liu Zhao-rong Ding Guang-hong Applied Mechanics Department,Fudan University,Shanghai,P.R.China 《Journal of Hydrodynamics》 SCIE EI CSCD 1989年第4期67-78,共12页
In this paper,the phenomenon on collapsible tube displacement oscillation,a new behavior of the collapsible tube puisatile flow has been studied.The experiments show that the collapsible tube,in which the flow is peri... In this paper,the phenomenon on collapsible tube displacement oscillation,a new behavior of the collapsible tube puisatile flow has been studied.The experiments show that the collapsible tube,in which the flow is periodic puisatile in the upstream,will oscillate as a simple supported beam when it is collapsed to certain extent,and that if the tube is collapsed continue,this oscillation will tend to weak and completely disappear lastly.An analytical model corresponding to the collapsible tube displacement oscillation and its governed equations are set up from the experiment background.By analysing the model and solving the equations, the collapsible tube displacement oscillation pattern and the oscillation occurring or disappearing criterion are obtained.The results predicted by this study are in agreement with those observed from experiment phenomena. 展开更多
关键词 THE PHENOMENON ON COLLAPSIBLE tube displacement OSCILLATION AND ITS THEORETICAL ANALYSIS As FLOW ITS
原文传递
Displacement of peritoneal end of a shunt tube to pleural cavity: A case report
4
作者 Jie Liu Mian Guo 《World Journal of Clinical Cases》 SCIE 2020年第19期4676-4680,共5页
BACKGROUND The common treatment for hydrocephalus is insertion of a ventriculoperitoneal shunt.Shunt tube displacement is one of the common complications.Most shunt tube displacements occur in children and has a repor... BACKGROUND The common treatment for hydrocephalus is insertion of a ventriculoperitoneal shunt.Shunt tube displacement is one of the common complications.Most shunt tube displacements occur in children and has a reportedly lower incidence in adults.CASE SUMMARY This study reports an adult patient(male,56 years)who suffered from intracranial aneurysm and subarachnoid hemorrhage and underwent aneurysm clipping following hospitalization.One month post onset of the disease,the patient underwent ventriculoperitoneal shunt due to hydrocephalus.The peritoneal end of the shunt tube was displaced in the peritoneal cavity 9 years after the aneurysm clipping.The peritoneal end of the shunt tube was removed and ventriculoperitoneal shunt was re-performed after anti-inflammatory treatment.CONCLUSION Shunt tube displacement has a low incidence in adults.In order to avoid shunt tube displacement,there is a need to summarize its causative factors and practice personalized medicine. 展开更多
关键词 Ventriculoperitoneal shunt HYDROCEPHALUS Shunt tube displacement Pleural cavity Intracranial aneurysm Case report Subarachnoid hemorrhage
下载PDF
X-tube通道下经椎间孔入路腰椎椎间融合内固定治疗单节段腰椎间盘突出症 被引量:11
5
作者 陈育岳 隋文渊 +3 位作者 石林 王建华 夏虹 尹庆水 《实用医学杂志》 CAS 北大核心 2011年第22期4103-4105,共3页
目的:探讨单节段腰椎间盘突出症治疗方法。方法:自2009年6月至2010年12月,我院共收治单节段腰椎间盘突出症患者中,采用X-tube通道下经椎间孔腰椎椎间融合内固定术病例27例,其中男17例,女10例;年龄28~36岁,平均31岁;病程2~9个月,平均5... 目的:探讨单节段腰椎间盘突出症治疗方法。方法:自2009年6月至2010年12月,我院共收治单节段腰椎间盘突出症患者中,采用X-tube通道下经椎间孔腰椎椎间融合内固定术病例27例,其中男17例,女10例;年龄28~36岁,平均31岁;病程2~9个月,平均5个月;疗效评价依据Mac_Nab腰腿痛评价标准以及改良Prolo功能评分标准。结果:所有患者均成功手术。手术时间2.5~3 h,平均2.7 h;出血量200~280 mL,平均250 mL;下地活动时间4~7 d,平均5 d;27例患者均获随访,时间3~18个月,平均12个月,Mac Nab标准疗效很好17例,占63%,好6例,占22.2%,轻度好转4例,占14.8%,无一例复发再次手术。术前Prolo功能评分平均为(10.5±1.6)分。改良Prolo评分平均为(17.0±0.9)分。结论:把握适应证的前提下,X-tube通道经椎间孔融合内固定术具有创伤小、出血量少、手术时间短以及并发症少的优点。 展开更多
关键词 椎间盘移位 X-tube通道 经椎间孔入路
下载PDF
Nosing process of empty and foam-filled circular metal tubes on semispherical die by theoretical and experimental investigations 被引量:1
6
作者 Seyed Ghaem AMIRHOSSEINI Abbas NIKNEJAD Nader SETOUDEH 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2017年第9期1976-1988,共13页
Nosing process of circular metal tubes in empty and polyurethane foam-filled conditions on a semispherical rigid die was analyzed by theoretical and experimental methods.A new theoretical model of plastic deformation ... Nosing process of circular metal tubes in empty and polyurethane foam-filled conditions on a semispherical rigid die was analyzed by theoretical and experimental methods.A new theoretical model of plastic deformation of circular metal tubes was demonstrated during the nosing process on a rigid semispherical die.Based on the analytical model,some theoretical relations were calculated to estimate instantaneous forming load and dissipated energy of empty and foam-filled circular metal tubes versus axial displacement.Some circular brazen and aluminum tubes were prepared and shaped into semispherical nosed nozzles to verify the present theory.Comparison of theoretical predictions and the corresponding experimental measurements reveals that predicted load?displacement and dissipated energy?displacement diagrams by theoretical formulas have a good correlation with the corresponding experimental curves and it proves verity of the theory.Also,the present theory shows that dissipated energy and axial load of empty tubes depend on material type,wall thickness and diameter of the tubes and they are independent of tube initial length.Furthermore,the experimental results show that the presence of polyethylene Teflon-constraints increases ultimate axial displacement of the forming process. 展开更多
关键词 plastic deformation nosing process dissipated energy circular tube NOZZLE axial load axial displacement
下载PDF
反复荷载下圆钢管型钢再生混凝土组合柱耗能能力及延性分析
7
作者 马辉 胡杰江 +2 位作者 赵艳丽 刘方达 席嘉诚 《世界地震工程》 北大核心 2024年第2期55-64,共10页
对11个圆钢管型钢再生混凝土组合柱试件进行了低周反复荷载试验,观察了组合柱的破坏形态及特征,获取了组合柱的滞回曲线、等效粘滞阻尼系数、延性系数及侧向位移角等性能指标,分析了再生粗骨料取代率、型钢截面形式、轴压比、型钢配钢... 对11个圆钢管型钢再生混凝土组合柱试件进行了低周反复荷载试验,观察了组合柱的破坏形态及特征,获取了组合柱的滞回曲线、等效粘滞阻尼系数、延性系数及侧向位移角等性能指标,分析了再生粗骨料取代率、型钢截面形式、轴压比、型钢配钢率和圆钢管径厚比等参数对组合柱耗能能力及延性的影响规律。结果表明:反复荷载作用下组合柱呈压弯塑性铰破坏模式;组合柱的荷载-位移滞回曲线饱满呈纺梭形,屈服位移后的等效粘滞阻尼系数在0.30~0.48之间,平均位移延性系数大于3.0,极限侧向位移角介于1/30~1/20之间且均大于规范限值1/50,组合柱表现出良好的耗能能力和延性。此外,组合柱的耗能能力和延性受再生粗骨料取代率的影响较大,全再生混凝土较普通混凝土耗能能力下降14.5%;增加钢管壁厚或型钢配钢率有利于提升组合柱的耗能能力和延性,而增大轴压比则对组合柱的延性和变形不利;内置型钢采用箱型截面时,组合柱耗能及延性最优,与工字型钢相比,采用箱型截面型钢的组合柱耗能能力和延性分别提升了23.5%和51.9%。 展开更多
关键词 圆钢管再生混凝土柱 型钢再生混凝土 滞回耗能 位移延性 抗震性能
下载PDF
水泥预加固-人工冻结联合工法加固地层冻胀特性
8
作者 王帅儒 金修伟 +3 位作者 陈士军 鹿庆蕊 张敏思 谢胜军 《科学技术与工程》 北大核心 2024年第13期5566-5576,共11页
以广州地铁十四号线一个联络通道冻结工程为背景,采用联合工法施工,通过有限元软件建立联络通道冻胀位移场三维数值模型,研究了盐水温度和水泥掺量对土体冻胀位移的影响,并计算不同冻结壁厚度下地表冻胀位移量以及联络通道开挖土体的塑... 以广州地铁十四号线一个联络通道冻结工程为背景,采用联合工法施工,通过有限元软件建立联络通道冻胀位移场三维数值模型,研究了盐水温度和水泥掺量对土体冻胀位移的影响,并计算不同冻结壁厚度下地表冻胀位移量以及联络通道开挖土体的塑性区域,在满足施工安全的前提下,进一步对冻结壁设计参数进行优化,以减小土体冻胀位移。结果表明:采用水泥预加固-人工冻结联合工法施工,当水泥掺量设定为12%,盐水温度控制在-31~-25℃时,积极冻结末期,地表冻胀位移能够满足工程监测要求;水泥掺量设定为12%,冻结壁厚度设定在1.8 m,盐水温度控制在-31℃。可见相对于原施工方案,采用联合工法施工,积极冻结末期地表冻胀量减小了73%。 展开更多
关键词 联合工法 冻胀位移 数值模拟 冻结 水泥
下载PDF
锆合金管塞结构压力电阻焊接头的应力集中系数及影响因素
9
作者 季顺成 张学粮 +4 位作者 林健(导师) 鲁立 陈兵兵 雷永平 冯刚 《机械工程材料》 CAS CSCD 北大核心 2024年第2期82-88,共7页
采用Abaqus有限元分析软件建立了锆合金管塞结构压力电阻焊接模型与应力集中系数计算模型,通过与热模拟试验得到的挤出金属高度进行对比,对焊接模型进行验证,模拟分析了内部挤出金属过渡角、端塞行进量和包壳管内壁倒角对接头应力集中... 采用Abaqus有限元分析软件建立了锆合金管塞结构压力电阻焊接模型与应力集中系数计算模型,通过与热模拟试验得到的挤出金属高度进行对比,对焊接模型进行验证,模拟分析了内部挤出金属过渡角、端塞行进量和包壳管内壁倒角对接头应力集中系数的影响。结果表明:内部挤出金属高度模拟结果和试验结果的相对误差为9.58%,外部挤出金属高度的相对误差为6.65%,说明建立的焊接模型准确;随着内部挤出金属过渡角增加,接头应力集中系数先降低,当过渡角增大至60°后增加,增大至120°时又下降;随着端塞行进量的增加,内部挤出金属过渡角降低,应力集中系数增加,接头熔合线长度增大;与未倒角接头相比,包壳管内壁倒角深度不大于0.50 mm时应力集中系数降低,最大降低了16.00%,倒角深度大于0.50 mm时应力集中系数增大,最大提高了91.49%。 展开更多
关键词 锆合金 管塞结构 压力电阻焊 应力集中系数 端塞行进量
下载PDF
大冷量多级推移活塞型脉管制冷机
10
作者 杨斌 刘知非 朱绍伟 《低温工程》 CAS CSCD 北大核心 2024年第3期87-92,共6页
使用阶梯推移活塞加惯性管的复合调相方式结合二者的调相优势,改善非最佳匹配尺寸下推移活塞脉管制冷机性能。对阶梯推移活塞加惯性管的复合调相方式的双级脉管制冷机进行了实验研究。在第二级采用复合调相结构时,在充气压力2 MPa,运行... 使用阶梯推移活塞加惯性管的复合调相方式结合二者的调相优势,改善非最佳匹配尺寸下推移活塞脉管制冷机性能。对阶梯推移活塞加惯性管的复合调相方式的双级脉管制冷机进行了实验研究。在第二级采用复合调相结构时,在充气压力2 MPa,运行频率51 Hz时,得到了86.4 K/22.9K的无负荷温度,在1 251 W输入功时,第二级在34.7 K得到5 W的冷量,为推移活塞双级脉管制冷机的性能优化提供了参考。 展开更多
关键词 推移活塞 双级脉管制冷机 复合调相
下载PDF
冻融循环作用后钢管混凝土界面黏结滑移本构模型研究
11
作者 曾在平 王宇航 +1 位作者 王秀丽 任根立 《建筑钢结构进展》 CSCD 北大核心 2024年第9期53-64,共12页
在北方寒冷地区,钢管混凝土结构因冻融作用侵蚀而造成钢管开裂以及钢管混凝土结构力学性能劣化从而导致结构破坏的事故时有发生。针对冻融侵蚀后钢管混凝土界面黏结性能问题,制作了钢管混凝土推出试件,考虑冻融循环次数、混凝土强度、... 在北方寒冷地区,钢管混凝土结构因冻融作用侵蚀而造成钢管开裂以及钢管混凝土结构力学性能劣化从而导致结构破坏的事故时有发生。针对冻融侵蚀后钢管混凝土界面黏结性能问题,制作了钢管混凝土推出试件,考虑冻融循环次数、混凝土强度、钢管径厚比等不同参数,进行冻融试验和推出试验,分析了界面黏结力的分布规律和影响因素,研究了冻融循环作用后钢管混凝土界面黏结滑移本构关系,确定了界面平均黏结强度以及峰值黏结强度、残余黏结强度特征值。结果表明,随着冻融循环次数的增加,界面平均黏结强度减小,极限荷载对应的滑移逐渐增大,而残余黏结强度呈线性减小,稳定段起点滑移随着冻融循环次数的增加呈指数增长。峰值黏结强度、残余黏结强度随混凝土强度的增加而提高,随着径厚比的增大而降低。分析外钢管密布应变计所测出的应变分布规律可知界面黏结应力呈指数分布,对比分析由荷载、滑移结合能量法理论推导所得的黏结应力分布函数,结果表明其具有较高精度,为后期研究界面黏结性能提供了新思路。构建了冻融循环作用后界面黏结应力-滑移三段式本构模型,并提出了相应特征值计算公式和本构模型,可为该类构件设计时考虑冻融作用提供参考。 展开更多
关键词 钢管混凝土 冻融作用 推出试验 界面黏结应力-滑移本构 黏结应力分布函数
下载PDF
冻融循环环境下方钢管混凝土粘结强度试验研究
12
作者 李俊华 王维宸 +1 位作者 周春恒 陈志辉 《工程力学》 EI CSCD 北大核心 2024年第S01期206-214,共9页
为研究冻融循环环境下方钢管混凝土的粘结性能,设计制作了19组57个方钢管混凝土短柱试件,并对这些试件开展冻融循环后的推出试验。获得了试件的荷载-滑移曲线,分析方钢管混凝土粘结力的组成以及冻融循环次数、构件长细比、钢管宽厚比对... 为研究冻融循环环境下方钢管混凝土的粘结性能,设计制作了19组57个方钢管混凝土短柱试件,并对这些试件开展冻融循环后的推出试验。获得了试件的荷载-滑移曲线,分析方钢管混凝土粘结力的组成以及冻融循环次数、构件长细比、钢管宽厚比对粘结强度的影响。试验结果表明,冻融循环后方钢管混凝土的荷载-滑移曲线与常温下总体相似,包含无滑移段、上升段、下降段、残余段。无滑移段的粘结作用由化学胶结力提供,滑移产生后的粘结作用由摩擦力和机械咬合力提供。在试验参数范围内,方钢管混凝土的粘结强度随着冻融循环作用次数增加呈幂函数减小,随着构件长细比的增大呈线性降低,随着钢管宽厚比的增大呈指数下降。在试验结果基础上,提出了冻融循环后方钢管混凝土粘结强度的计算公式,计算结果与试验结果总体总体吻合。 展开更多
关键词 钢管混凝土 冻融循环 推出试验 粘结强度 粘结退化
下载PDF
考虑砌筑砂浆劣化的老旧砌体结构抗震性能分析
13
作者 卢晨虎 宋波 +3 位作者 王满生 刁硕 王超 马梦雪 《建筑结构》 北大核心 2024年第9期139-143,共5页
北京地区现存大量建造于1980年前后的在役老旧砌体房屋,因服役时间较长,普遍存在建筑材料劣化的现象。选取砌筑砂浆作为研究对象,通过分析冻融循环劣化过程和现场砌筑砂浆实测结果,建立北京地区实际服役环境下砂浆抗压强度劣化时变模型... 北京地区现存大量建造于1980年前后的在役老旧砌体房屋,因服役时间较长,普遍存在建筑材料劣化的现象。选取砌筑砂浆作为研究对象,通过分析冻融循环劣化过程和现场砌筑砂浆实测结果,建立北京地区实际服役环境下砂浆抗压强度劣化时变模型。通过建立典型老旧砌体结构房屋有限元模型,采用层间位移角作为评价指标,对不同建造年代的砌体房屋抗震性能进行分析研究。结果表明,随着服役时间增加,该六层砌体结构整体位移响应增大,且主要发生在服役20年之后。在7度设防地震作用时,服役超过40年的砌体房屋损伤接近严重破坏状态,难以满足抗震设防要求。在峰值加速度为200gal的地震作用时,未劣化砌体结构没有达到倒塌状态,而服役50年的劣化砌体结构进入倒塌状态指标界限内,抵抗倒塌的能力下降十分显著,显示出对多年服役劣化砌体结构进行鉴定加固的急迫性。 展开更多
关键词 老旧砌体结构 砌筑砂浆劣化 冻融循环 抗压强度劣化时变模型 抗震性能分析 层间位移角
下载PDF
间接空冷翅片管束临界防冻特性及防冻裕量研究
14
作者 张明玉 王晓静 +8 位作者 关欣 郭文军 周维博 孙凯 谢欣雯 张昊天 赵一鸣 张冬月 王伟佳 《热力发电》 CAS CSCD 北大核心 2024年第4期92-101,共10页
间接空冷翅片管束目前缺乏全面的冬季防冻运行参数。为此,首先凝练了管束防冻模型,包括热平衡方程、水侧和空气侧输运准则方程、防冻约束条件;其次依托典型顺逆流式空冷翅片管束,分析了2类管束临界防冻特性和防冻裕量;最后探究了中间型... 间接空冷翅片管束目前缺乏全面的冬季防冻运行参数。为此,首先凝练了管束防冻模型,包括热平衡方程、水侧和空气侧输运准则方程、防冻约束条件;其次依托典型顺逆流式空冷翅片管束,分析了2类管束临界防冻特性和防冻裕量;最后探究了中间型、左侧型、侧面型进水方式管束的临界值特点。结果表明:环境温度和入口水温降低、风速增加,管束防冻流量增加,且入口水温越低,风速影响更突出;逆流式管束防冻性能劣于顺流式管束,随风速增加或入口水温降低,二者差异扩大;入口水温抬升对防冻裕量影响分为3个梯次,为显著增加区间(0℃, 10℃]、变化缓慢区间(10℃, 20℃]、基本不变区间(20℃, 40℃],不可一直增加入口水温来防冻;中间型管束防冻性能优于左侧型和侧面型,空冷燃煤火电或核电机组应优先选用。研究结果可为我国空冷机组冬季防冻运行提供指导。 展开更多
关键词 空冷翅片管束 管束防冻模型 临界防冻流量 防冻裕量 管束进水方式
下载PDF
带低屈服点钢耗能梁段高强钢框筒结构的结构影响系数和位移放大系数研究
15
作者 周玉浩 连鸣 韩瑞祥 《建筑钢结构进展》 CSCD 北大核心 2024年第1期41-53,共13页
在传统钢框筒结构的部分裙梁跨中处设置LYP225低屈服点钢耗能梁段,其余构件采用Q460高强度钢材,提出带低屈服点钢耗能梁段高强钢框筒结构(HSS-FTS-LSL)。在地震作用下耗能梁段发生剪切屈服耗散地震能量,梁、柱等构件由于采用高强钢从而... 在传统钢框筒结构的部分裙梁跨中处设置LYP225低屈服点钢耗能梁段,其余构件采用Q460高强度钢材,提出带低屈服点钢耗能梁段高强钢框筒结构(HSS-FTS-LSL)。在地震作用下耗能梁段发生剪切屈服耗散地震能量,梁、柱等构件由于采用高强钢从而保持弹性或部分进入塑性阶段。为了研究HSS-FTS-LSL的结构影响系数和位移放大系数,以楼层数、耗能梁段长度及布置方式为变量,按照我国规范设计了3组共8个HSS-FTS-LSL算例,并且考虑高阶振型的影响,采用分布侧向力调整法对各算例进行了Pushover分析,基于改进的能力谱法计算了8个算例的结构影响系数和位移放大系数,分析了结构层数、耗能梁段长度及布置方式对结构性能系数的影响并给出了建议取值。最后,根据提出的HSS-FTS-LSL抗震设计反应谱对其中一个结构算例进行重设计,并对重设计前后两个算例结构进行弹塑性分析,对比了二者的抗震性能以及用钢量,验证了本文提出的HSS-FTS-LSL结构影响系数建议值的合理性。 展开更多
关键词 低屈服点钢 钢框筒结构 剪切型耗能梁段 分布侧向力调整法 改进的能力谱法 结构影响系数 位移放大系数
下载PDF
围岩冻融劣化对季节性寒区隧道稳定性的影响研究
16
作者 冯强 赵子栋 +4 位作者 刘海涛 刘炜炜 王洪波 张新鹏 张强 《金属矿山》 CAS 北大核心 2024年第5期199-209,共11页
围岩冻融损伤会造成衬砌受到的变形压力增大,对衬砌的稳定性造成不利影响,是季节性寒区隧道工程研究的一个关键问题。通过对砂岩的冻融循环试验和压缩试验得到不同冻融次数下的砂岩应力—应变曲线,然后通过应力—应变曲线得到围岩的变... 围岩冻融损伤会造成衬砌受到的变形压力增大,对衬砌的稳定性造成不利影响,是季节性寒区隧道工程研究的一个关键问题。通过对砂岩的冻融循环试验和压缩试验得到不同冻融次数下的砂岩应力—应变曲线,然后通过应力—应变曲线得到围岩的变形参数和强度参数,最后将岩石力学参数变化规律嵌入ABAQUS软件中对冻融循环条件下的隧道长期稳定性进行数值分析,分别得到循环冻融0、6、12、18、24次下的围岩和衬砌的应力场及位移场。结果表明:①随着冻融循环次数增加,围岩所受的最大主应力和最小主应力均呈线性减小;②衬砌所受的最大主应力、最小主应力及衬砌位移均呈指数增大;③与未经冻融的情况相比,冻融循环24次后围岩的最大主应力、最小主应力分别减小了43.69%、20.66%;④衬砌的最大主应力、最小主应力及拱顶最大沉降分别增大了13.64%、15.75%、49.36%。在进行寒区隧道支护设计时,应考虑冻融作用下围岩自稳能力衰减而导致支护结构受力增大的问题。 展开更多
关键词 寒区隧道 隧道稳定性 冻融循环 围岩 应力场 位移场
下载PDF
卸压孔设置对冻结暗挖隧道冻胀卸荷影响研究
17
作者 黄建华 陈伟斌 严耿明 《人民长江》 北大核心 2024年第2期146-155,170,共11页
冻结法暗挖隧道施工中,冻胀常导致土体和隧道等发生大变形,给地铁隧道和周边环境以及建(构)筑物带来不利影响。以福州市滨海软土地层冻结暗挖隧道工程为例,通过对原型工程建模和非线性分析,综合实测数据及工程情况,分析冻胀变形分布规... 冻结法暗挖隧道施工中,冻胀常导致土体和隧道等发生大变形,给地铁隧道和周边环境以及建(构)筑物带来不利影响。以福州市滨海软土地层冻结暗挖隧道工程为例,通过对原型工程建模和非线性分析,综合实测数据及工程情况,分析冻胀变形分布规律和设置卸压孔前后冻结暗挖隧道的位移变化特点。研究结果表明:人工冻结加固技术结合卸压孔应用,对土体冻胀力的释放和冻胀变形的控制效果较好,与没有设置卸压孔时的地层相比,卸压孔在冻土帷幕冻结交圈形成后,为土体冻胀提供自由变形空间,降低了土体的冻胀位移和冻胀应力;冻结期末2个冻结暗挖隧道中心点纵向剖面处冻胀位移最大值由28.88 mm降至16.75 mm,冻胀应力最大值由335 kPa降至265 kPa,卸压作用效果明显。研究结果可为人工冻结暗挖隧道工程提供借鉴和参考。 展开更多
关键词 冻结法 冻胀变形 卸压孔 位移场 暗挖隧道
下载PDF
沈阳地铁联络通道冻结法工程应用技术研究
18
作者 张效铭 寇广东 《山西建筑》 2024年第11期139-142,147,共5页
沈阳地铁联络通道兼泵房采用冻结法施工技术,保证冻结帷幕快速稳定发展是其施工关键所在。在冻结施工过程中,对低温盐水回路温度、冻土发展温度及地表位移沉降数据进行现场监测分析,从而确定冻结帷幕的发展规律及安全稳定性,确保工程施... 沈阳地铁联络通道兼泵房采用冻结法施工技术,保证冻结帷幕快速稳定发展是其施工关键所在。在冻结施工过程中,对低温盐水回路温度、冻土发展温度及地表位移沉降数据进行现场监测分析,从而确定冻结帷幕的发展规律及安全稳定性,确保工程施工各项数据达标。结果表明:温度随着冻结时间的变化先是急剧下降,之后会缓慢降低直至趋于稳定;冻结壁交圈根据监测是当卸压孔开始增大一段时间后无泥沙渗流,表明冻结帷幕形成良好;地表位移沉降一直处于稳定状态,无任何隆起、沉降、塌陷等现象发生,可保证冻结施工的如期进行。同时开挖施工获得的冻土帷幕信息证实了监测数据的准确性。 展开更多
关键词 地铁联络通道 冻结法施工 冻结帷幕 施工监测 地表位移
下载PDF
宁波地铁5号线联络通道人工冻结法应用研究
19
作者 范大军 陈军 +1 位作者 庄兴岳 黄朝煊 《水利与建筑工程学报》 2024年第2期199-206,共8页
随着人工冷冻技术的发展,人工冻结法(AGFM)已在地下空间建设中推广采用,依托宁波市轨道交通5号线隧道联络通道冻结法施工工程,通过室内试验分别对土体起始冻结温度、导热系数、比热容系数、土层冻胀率及融沉率等进行试验研究,得出主要... 随着人工冷冻技术的发展,人工冻结法(AGFM)已在地下空间建设中推广采用,依托宁波市轨道交通5号线隧道联络通道冻结法施工工程,通过室内试验分别对土体起始冻结温度、导热系数、比热容系数、土层冻胀率及融沉率等进行试验研究,得出主要土层的导热系数与温度、比热容系数与温度、土层冻胀率与附加应力之间的线性拟合计算式,提出并建立人工冻结过程中考虑热物理参数随温度变化的热-力耦合的三维数值计算方法,并结合现场温度场、位移场等监测资料,得到宁波市轨道交通5号线联络段主要控制土层粉质黏土层的最小冻结壁厚度为1.79m~2.38m,冻结壁平均温度-12.13℃~-20.3℃,满足设计要求;现场四个监测断面点的位移收敛值均相对较小,最大位移收敛值不超过4 mm,整体表明冻结法施工过程中冻胀力对隧道的影响较小,理论计算成果基本与现场实测规律吻合。 展开更多
关键词 地铁联络通道 人工冻结法 数值计算 温度场 位移场 冻结壁
下载PDF
液氮冷冻法收集和检测黄金管内轻烃组分的实验细节探讨
20
作者 李阔 《石化技术》 CAS 2024年第3期32-34,共3页
探讨了实验室条件下烃烃萃取和检测过程的具体步骤和实施细节,通过试验优化实验条件并形成了可操作性强、再行性好的实验方法。该方法可兼顾黄金管生烃产物中C6~C14产率定量以及C6~C8轻烃化合物的检测,是对黄金管生烃模拟实验技术的补充... 探讨了实验室条件下烃烃萃取和检测过程的具体步骤和实施细节,通过试验优化实验条件并形成了可操作性强、再行性好的实验方法。该方法可兼顾黄金管生烃产物中C6~C14产率定量以及C6~C8轻烃化合物的检测,是对黄金管生烃模拟实验技术的补充,有助于开展烃源岩轻烃特征的研究工作。 展开更多
关键词 黄金管 液氮冷冻 轻烃萃取 气相色谱 定量
下载PDF
上一页 1 2 26 下一页 到第
使用帮助 返回顶部