A modified slow-fast analysis method is presented for the periodically excited non-autonomous dynamical system with an order gap between the exciting frequency and the natural frequency.By regarding the exciting term ...A modified slow-fast analysis method is presented for the periodically excited non-autonomous dynamical system with an order gap between the exciting frequency and the natural frequency.By regarding the exciting term as a slow-varying parameter,a generalized autonomous fast subsystem can be defined,the equilibrium branches as well as the bifurcations of which can be employed to account for the mechanism of the bursting oscillations by combining the transformed phase portrait introduced.As an example,a typical periodically excited Hartley model is used to demonstrate the validness of the method,in which the exciting frequency is far less than the natural frequency.The equilibrium branches and their bifurcations of the fast subsystem with the variation of the slow-varying parameter are presented.Bursting oscillations for two typical cases are considered,which reveals that,fold bifurcation may cause the the trajectory to jump between different equilibrium branches,while Hopf bifurcation may cause the trajectory to oscillate around the stable limit cycle.展开更多
Based on the concept of the constitutive relation error along with the residuals of both the origin and the dual problems, a goal-oriented error estimation method with extended degrees of freedom is developed. It lead...Based on the concept of the constitutive relation error along with the residuals of both the origin and the dual problems, a goal-oriented error estimation method with extended degrees of freedom is developed. It leads to the high quality locM error bounds in the problem of the direct-solution steady-state dynamic analysis with a frequency-domain finite element, which involves the enrichments with plural variable basis functions. The solution of the steady-state dynamic procedure calculates the harmonic response directly in terms of the physical degrees of freedom in the model, which uses the mass, damping, and stiffness matrices of the system. A three-dimensional finite element example is carried out to illustrate the computational procedures.展开更多
A frequency and spatial domain decomposition method (FSDD) for operational modal analysis (OMA) is presented in this paper, which is an extension of the complex mode indicator function (CMIF) method for experime...A frequency and spatial domain decomposition method (FSDD) for operational modal analysis (OMA) is presented in this paper, which is an extension of the complex mode indicator function (CMIF) method for experimental modal analysis (EMA). The theoretical background of the FSDD method is clarified, Singular value decomposition is adopted to separate the signal space from the noise space. Finally, an enhanced power spectrum density (PSD) is proposed to obtain more accurate modal parameters by curve fitting in the frequency domain. Moreover, a simulation case and an application case are used to validate this method.展开更多
Error analysis methods in frequency domain are developed in this paper for determining the characteristic root and transfer function errors when the linear multipass algorithms are used to solve linear differential eq...Error analysis methods in frequency domain are developed in this paper for determining the characteristic root and transfer function errors when the linear multipass algorithms are used to solve linear differential equations. The relation between the local truncation error in time domain and the error in frequency domain is established, which is the basis for developing the error estimation methods. The error estimation methods for the digital simulation model constructed by using the Runge-Kutta algorithms and the linear multistep predictor-corrector algorithms are also given.展开更多
This paper surveys a number of recent advances in the error analysis in the frequency domain for a digital simulation model. It is emphasized to discuss the errors in characteristic roots and transfer funcnon of the d...This paper surveys a number of recent advances in the error analysis in the frequency domain for a digital simulation model. It is emphasized to discuss the errors in characteristic roots and transfer funcnon of the digital simulation model, the frequency domain errors of the data transfers between thesimulation submodels, and some compensation methods for the errors. Some of the questions to be answered are also presented.展开更多
This work proposes a robust fault detection and isolation scheme for discrete-time systems subject to actuator faults,in which a bank of H_/H∞ fault detection unknown input observers(UIOs) and a zonotopic threshold a...This work proposes a robust fault detection and isolation scheme for discrete-time systems subject to actuator faults,in which a bank of H_/H∞ fault detection unknown input observers(UIOs) and a zonotopic threshold analysis strategy are considered. In observer design, finite-frequency H_ index based on the generalized Kalman-Yakubovich-Popov lemma and H∞ technique are utilized to evaluate worst-case fault sensitivity and disturbance attenuation performance, respectively. The proposed H_/H∞ fault detection observers are designed to be insensitive to the corresponding actuator fault only, but sensitive to others.Then, to overcome the weakness of predefining threshold for FDI decision-making, this work proposes a zonotopic threshold analysis method to evaluate the generated residuals. The FDI decision-making relies on the evaluation with a dynamical zonotopic threshold. Finally, numerical simulations are provided to show the feasibility of the proposed scheme.展开更多
Wireless networking in cyber-physical systems(CPSs) is characteristically different from traditional wireless systems due to the harsh radio frequency environment and applications that impose high real-time and reliab...Wireless networking in cyber-physical systems(CPSs) is characteristically different from traditional wireless systems due to the harsh radio frequency environment and applications that impose high real-time and reliability constraints.One of the fundamental considerations for enabling CPS networks is the medium access control protocol. To this end, this paper proposes a novel priority-aware frequency domain polling medium access control(MAC) protocol, which takes advantage of an orthogonal frequency-division multiple access(OFDMA)physical layer to achieve instantaneous priority-aware polling.Based on the polling result, the proposed work then optimizes the resource allocation of the OFDMA network to further improve the data reliability. Due to the non-polynomial-complete nature of the OFDMA resource allocation, we propose two heuristic rules,based on which an efficient solution algorithm to the OFDMA resource allocation problem is designed. Simulation results show that the reliability performance of CPS networks is significantly improved because of this work.展开更多
In this study, simplified numerical models are developed to analyze the soil-structure interaction (SSI) effect on frame structures equipped with viscoelastic dampers (VEDs) based on pile group foundation. First, ...In this study, simplified numerical models are developed to analyze the soil-structure interaction (SSI) effect on frame structures equipped with viscoelastic dampers (VEDs) based on pile group foundation. First, a single degree-of- freedom (SDOF) oscillator is successfully utilized to replace the SDOF energy dissipated structure considering the SSI effect. The equivalent period and damping ratio of the system are obtained through analogical analysis using the frequency transfer function with adoption of the modal strain energy (MSE) technique. Aparametric analysis is carried out to study the SSI effect on the performance of VEDs. Then the equilibrium equations of the multi degree-of-freedom (MDOF) structure with VEDs considering SSI effect are established in the frequency domain. Based on the assumption that the superstructure of the coupled system possesses the classical normal mode, the MDOF superstructure is decoupled to a set of individual SDOF systems resting on a rigid foundation with adoption of the MSE technique through formula derivation. Numerical results demonstrate that the proposed methods have the advantage of reducing computational cost, however, retaining the satisfactory accuracy. The numerical method proposed herein can provide a fast evaluation of the efficiency of VEDs considering the SSI effect.展开更多
Output-only structural identification is developed by a refined Frequency Domain Decomposition(rFDD) approach, towards assessing current modal properties of heavy-damped buildings(in terms of identification challe...Output-only structural identification is developed by a refined Frequency Domain Decomposition(rFDD) approach, towards assessing current modal properties of heavy-damped buildings(in terms of identification challenge), under strong ground motions. Structural responses from earthquake excitations are taken as input signals for the identification algorithm. A new dedicated computational procedure, based on coupled Chebyshev Type Ⅱ bandpass filters, is outlined for the effective estimation of natural frequencies, mode shapes and modal damping ratios. The identification technique is also coupled with a Gabor Wavelet Transform, resulting in an effective and self-contained time-frequency analysis framework. Simulated response signals generated by shear-type frames(with variable structural features) are used as a necessary validation condition. In this context use is made of a complete set of seismic records taken from the FEMA P695 database, i.e. all 44 "Far-Field"(22 NS, 22 WE) earthquake signals. The modal estimates are statistically compared to their target values, proving the accuracy of the developed algorithm in providing prompt and accurate estimates of all current strong ground motion modal parameters. At this stage, such analysis tool may be employed for convenient application in the realm of Earthquake Engineering, towards potential Structural Health Monitoring and damage detection purposes.展开更多
The high frequency-very high frequency(HF-VHF)frequency band is of significant importance in astronomical observations,with applications studying various phenomena such as space weather,solar radio emissions,planetary...The high frequency-very high frequency(HF-VHF)frequency band is of significant importance in astronomical observations,with applications studying various phenomena such as space weather,solar radio emissions,planetary eruptions in the solar system,pulsars,transient sources,and reionization of the early universe.This article introduces the HF-VHF frequency band multifunctional radio astronomical terminal system based on a dual-channel high-speed acquisition board with a frequency observation range of 1-250 MHz and a sampling rate of 500 Msps(Mega samples per second).The maximum quantization bit of the system is 14 bits,with a maximum time resolution of 0.1 s and a maximum spectral resolution of 16 kHz.The system combines spectral analysis of solar radio signals and recording of time-domain data of signals interfering with long baselines,and adopts a server-client separation mode to allow remote operation with separate permissions.It is used in the China-Malaysia joint astronomy project,which can carry out single-site observation of solar radio signals as well as interferometric observation of signals from multiple sites.展开更多
Arc welding converter (AWC) power source is a nonlinear and discrete abnormal system. It is difficult to get the accurate analytic solution in theory. In this paper, an average state equation of the system is establi...Arc welding converter (AWC) power source is a nonlinear and discrete abnormal system. It is difficult to get the accurate analytic solution in theory. In this paper, an average state equation of the system is established by means of state space analysis method. The mathematics model of the reverse converter is gotten after the average equation of the system is linearized. The model is a two ranks oscillation link. With the parameters of the AWC, when the condition of (1/RC) 2 >>4/LC is available, the mathematics model may be simplified to a serial structure which includes a integral link and a one rank inertia link. On the basis of this, it can be analyzed and rectified in frequency domain, then some groups of reality rectification parameters are gotten around the theory rectification parameters. These groups of parameters are taken to do the resistance load experiment and welding technology experiment. The result of experiment accords with the theory analysis result. This paper also provides some practical analysis of the model under the large signal process such as the sudden opening of the load, short circuit, turning on and turning off the machine. The result of the research shows that the power source system of AWC can be analyzed and rectified by the frequency domain analysis method in the engineering. The deduced mathematics model of small signal average frequency domain shows the basic characteristics of the system, and the structure parameters of the system is formed by R, L, C and switching ratio D. The model is very simple and clear, and it can be used to analyze and design the power source system of AWC and it can also be used to direct the regulation for dynamic characteristics of the system.展开更多
This paper presents a novel algorithm of fault location for transmission line.Solving the network spectrum equations for different frequencies the fault can be located accurately by this algorithm with one terminal da...This paper presents a novel algorithm of fault location for transmission line.Solving the network spectrum equations for different frequencies the fault can be located accurately by this algorithm with one terminal data of voltage and current,and the identified parameters,such as fault distance, fault resistance,and opposite terminal system resistance and inductance.The algorithm eliminates the influence of the opposite system impedance on the fault location accuracy,which causes the main error in traditional fault location methods using one terminal data.A method of calculating spectrum from sampled data is also proposed.EMTP simulations show the validity and higher accuracy of the fault location algorithm compared to the existing ones based on one terminal data.展开更多
The mode-based damping torque analysis(M-DTA)method for studying the effect of an external controller on power system low-frequency oscillations is proposed in this paper.First,based on the interconnection model betwe...The mode-based damping torque analysis(M-DTA)method for studying the effect of an external controller on power system low-frequency oscillations is proposed in this paper.First,based on the interconnection model between the system and the controller in the frequency domain,the oscillation loop corresponding to the electromechanical oscillation mode is built,and then the mode-based damping torque of the controller can be calculated.Then,the application of the M-DTA method in the power system is illustrated.The derivation shows that in the single-machine infinite-bus power system,the M-DTA method is completely equivalent to the classical damping torque analysis(C-DTA)method.In the multi-machine power system,the mode-based damping torque directily reflects the effect of the controller on the oscillation mode,overcoming the shortcomings of the C-DTA method in which there is no direct correspondence between the damping torque and the oscillation mode.By deriving the relationship with the residue index,the M-DTA method shows higher accuracy than the residue method in applications,such as controller parameter adjustment.Finally,two example power systems are presented to demonstrate the application of the proposed M-DTA method.Index Terms-Electromechanical oscillation mode,FACTS,interconnection model in the frequency domain,mode-based damping torque analysis(M-DTA),power system low-frequency oscillation,PSS,residue method.展开更多
新能源接入现有电网将弱化系统的频率稳定性。充分利用调频资源对提升电网稳定性具有重要意义。火电作为当前调频主要资源有着复杂多变的特性,在不同工况下调频能力也会不同;且随着渗透率提高,传统的下垂控制调频方式逐渐不能满足控制...新能源接入现有电网将弱化系统的频率稳定性。充分利用调频资源对提升电网稳定性具有重要意义。火电作为当前调频主要资源有着复杂多变的特性,在不同工况下调频能力也会不同;且随着渗透率提高,传统的下垂控制调频方式逐渐不能满足控制要求。因此,提出一种储能–火电互补频率控制策略,设计了随频率变化自适应调节的出力比重系数,实现了储能出力的自适应调整,并将线性自抗扰控制(Linear active disturbance rejection control,LADRC)应用于火电机组的控制,通过频域法分析典型工业控制对象的LADRC参数调节规律。仿真结果表明,相较于传统下垂控制策略,所提出的储能–火电互补频率控制策略使系统的频率偏差最大值与稳态偏差值显著降低,并且有更好的储能恢复效果。展开更多
Power inverter adopting virtual synchronous generator(VSG)control can provide inertia support for distributed generation systems.However,it cannot take into account the dynamic regulation characteristics of frequency....Power inverter adopting virtual synchronous generator(VSG)control can provide inertia support for distributed generation systems.However,it cannot take into account the dynamic regulation characteristics of frequency.Thus,when the system encounters a sudden change in load or disturbance,the dynamic process of frequency regulation will be greatly influenced.In view of this issue,an improved VSG control strategy based on a coordinated self-adaptive(CSA)method is proposed.The time domain analysis method is used to study the influences of virtual inertia and damping parameter perturbation on the system steady and dynamic performances.Furthermore,in order to make the control strategy suitable for large load changes and suppress frequency variations beyond the limit,the secondary frequency modulation is introduced into the control loop.Through the coordinated adaptive control of virtual inertia,virtual damping and frequency modulation,the dynamic performance of vSG frequency regulation can be obviously improved.Simulation and experiment results have verified the effectiveness of the proposed CSA control strategy.展开更多
The present paper develops a new method for damage localization and severity estimation based on the employment of modal strain energy. This method is able to determine the damage locations and estimate their severiti...The present paper develops a new method for damage localization and severity estimation based on the employment of modal strain energy. This method is able to determine the damage locations and estimate their severities, requiring only the information about the changes of a few lower natural frequencies. First, a damage quantification method is formulated and iterative approach is adopted for determining the damage extent. Then a damage localization algorithm is proposed, in which a damage indicator is formulated where unity value corresponds to the true damage scenario. Finally, numerical studies and model tests are conducted to demonstrate the effectiveness of the developed algorithm.展开更多
基金supported by the National Natural Science Foundation of China(Grants11632008 and 11872189)
文摘A modified slow-fast analysis method is presented for the periodically excited non-autonomous dynamical system with an order gap between the exciting frequency and the natural frequency.By regarding the exciting term as a slow-varying parameter,a generalized autonomous fast subsystem can be defined,the equilibrium branches as well as the bifurcations of which can be employed to account for the mechanism of the bursting oscillations by combining the transformed phase portrait introduced.As an example,a typical periodically excited Hartley model is used to demonstrate the validness of the method,in which the exciting frequency is far less than the natural frequency.The equilibrium branches and their bifurcations of the fast subsystem with the variation of the slow-varying parameter are presented.Bursting oscillations for two typical cases are considered,which reveals that,fold bifurcation may cause the the trajectory to jump between different equilibrium branches,while Hopf bifurcation may cause the trajectory to oscillate around the stable limit cycle.
基金Project supported by the National Natural Science Foundation of China (No. 10876100)
文摘Based on the concept of the constitutive relation error along with the residuals of both the origin and the dual problems, a goal-oriented error estimation method with extended degrees of freedom is developed. It leads to the high quality locM error bounds in the problem of the direct-solution steady-state dynamic analysis with a frequency-domain finite element, which involves the enrichments with plural variable basis functions. The solution of the steady-state dynamic procedure calculates the harmonic response directly in terms of the physical degrees of freedom in the model, which uses the mass, damping, and stiffness matrices of the system. A three-dimensional finite element example is carried out to illustrate the computational procedures.
基金China Postdoctoral Science Foundation Under Grant No. 2004035215 Jiangsu Planned Projects for Postdoctoral Research Funds 2004 Aeronautical Science Research Foundation Under Grant No. 04152065
文摘A frequency and spatial domain decomposition method (FSDD) for operational modal analysis (OMA) is presented in this paper, which is an extension of the complex mode indicator function (CMIF) method for experimental modal analysis (EMA). The theoretical background of the FSDD method is clarified, Singular value decomposition is adopted to separate the signal space from the noise space. Finally, an enhanced power spectrum density (PSD) is proposed to obtain more accurate modal parameters by curve fitting in the frequency domain. Moreover, a simulation case and an application case are used to validate this method.
基金This project was supported by the National Natural Science Foundation of China (No. 19871080).
文摘Error analysis methods in frequency domain are developed in this paper for determining the characteristic root and transfer function errors when the linear multipass algorithms are used to solve linear differential equations. The relation between the local truncation error in time domain and the error in frequency domain is established, which is the basis for developing the error estimation methods. The error estimation methods for the digital simulation model constructed by using the Runge-Kutta algorithms and the linear multistep predictor-corrector algorithms are also given.
文摘This paper surveys a number of recent advances in the error analysis in the frequency domain for a digital simulation model. It is emphasized to discuss the errors in characteristic roots and transfer funcnon of the digital simulation model, the frequency domain errors of the data transfers between thesimulation submodels, and some compensation methods for the errors. Some of the questions to be answered are also presented.
基金partially supported by National Key R&D Program of China(2018YFB1304600)National Natural Science Foundation of China(51805021,U1813220)+1 种基金China Postdoctoral Science Foundation Grant(2018M631311)the Fundamental Research Funds for the Central Universities(XK1802-4)
文摘This work proposes a robust fault detection and isolation scheme for discrete-time systems subject to actuator faults,in which a bank of H_/H∞ fault detection unknown input observers(UIOs) and a zonotopic threshold analysis strategy are considered. In observer design, finite-frequency H_ index based on the generalized Kalman-Yakubovich-Popov lemma and H∞ technique are utilized to evaluate worst-case fault sensitivity and disturbance attenuation performance, respectively. The proposed H_/H∞ fault detection observers are designed to be insensitive to the corresponding actuator fault only, but sensitive to others.Then, to overcome the weakness of predefining threshold for FDI decision-making, this work proposes a zonotopic threshold analysis method to evaluate the generated residuals. The FDI decision-making relies on the evaluation with a dynamical zonotopic threshold. Finally, numerical simulations are provided to show the feasibility of the proposed scheme.
基金supported by National Natural Science Foundation of China(61304263,61233007)the Cross-disciplinary Collaborative Teams Program for Science,Technology and Innovation of Chinese Academy of Sciences-Network and System Technologies for Security Monitoring and Information Interaction in Smart Arid
文摘Wireless networking in cyber-physical systems(CPSs) is characteristically different from traditional wireless systems due to the harsh radio frequency environment and applications that impose high real-time and reliability constraints.One of the fundamental considerations for enabling CPS networks is the medium access control protocol. To this end, this paper proposes a novel priority-aware frequency domain polling medium access control(MAC) protocol, which takes advantage of an orthogonal frequency-division multiple access(OFDMA)physical layer to achieve instantaneous priority-aware polling.Based on the polling result, the proposed work then optimizes the resource allocation of the OFDMA network to further improve the data reliability. Due to the non-polynomial-complete nature of the OFDMA resource allocation, we propose two heuristic rules,based on which an efficient solution algorithm to the OFDMA resource allocation problem is designed. Simulation results show that the reliability performance of CPS networks is significantly improved because of this work.
基金National Natural Science Foundation of China under Grant Nos.51678302 and 51678301Jiangsu Province Industry-University-Research Joint Innovation Fund--Prospective Joint Research Project under Grant No.BY2014005-05Major Program of Natural Science Foundation of the Jiangsu Higher Education Institutions of China under Grant No.14KJA560001
文摘In this study, simplified numerical models are developed to analyze the soil-structure interaction (SSI) effect on frame structures equipped with viscoelastic dampers (VEDs) based on pile group foundation. First, a single degree-of- freedom (SDOF) oscillator is successfully utilized to replace the SDOF energy dissipated structure considering the SSI effect. The equivalent period and damping ratio of the system are obtained through analogical analysis using the frequency transfer function with adoption of the modal strain energy (MSE) technique. Aparametric analysis is carried out to study the SSI effect on the performance of VEDs. Then the equilibrium equations of the multi degree-of-freedom (MDOF) structure with VEDs considering SSI effect are established in the frequency domain. Based on the assumption that the superstructure of the coupled system possesses the classical normal mode, the MDOF superstructure is decoupled to a set of individual SDOF systems resting on a rigid foundation with adoption of the MSE technique through formula derivation. Numerical results demonstrate that the proposed methods have the advantage of reducing computational cost, however, retaining the satisfactory accuracy. The numerical method proposed herein can provide a fast evaluation of the efficiency of VEDs considering the SSI effect.
基金Public research funding from“Fondi di Ricerca d’Ateneo ex 60%” and a ministerial doctoral grantfunds at the ISA Doctoral School,University of Bergamo,Department of Engineering and Applied Sciences (Dalmine)
文摘Output-only structural identification is developed by a refined Frequency Domain Decomposition(rFDD) approach, towards assessing current modal properties of heavy-damped buildings(in terms of identification challenge), under strong ground motions. Structural responses from earthquake excitations are taken as input signals for the identification algorithm. A new dedicated computational procedure, based on coupled Chebyshev Type Ⅱ bandpass filters, is outlined for the effective estimation of natural frequencies, mode shapes and modal damping ratios. The identification technique is also coupled with a Gabor Wavelet Transform, resulting in an effective and self-contained time-frequency analysis framework. Simulated response signals generated by shear-type frames(with variable structural features) are used as a necessary validation condition. In this context use is made of a complete set of seismic records taken from the FEMA P695 database, i.e. all 44 "Far-Field"(22 NS, 22 WE) earthquake signals. The modal estimates are statistically compared to their target values, proving the accuracy of the developed algorithm in providing prompt and accurate estimates of all current strong ground motion modal parameters. At this stage, such analysis tool may be employed for convenient application in the realm of Earthquake Engineering, towards potential Structural Health Monitoring and damage detection purposes.
基金supported by National Natural Science Foundation of China(U2031133)National Key Research and Development Program of China(11941003)+4 种基金Applied Basic Research Program of Yunnan Province(2019FB009)Basic Research Program of Yunnan Province(202301AT070325)Square Kilometer Array(SKA)Project of the Ministry of Science and Technology of China(2020SKA0110202)International Partnership Program of the Chinese Academy of Sciences(114A11KYSB20200001)Kunming Municipal Foreign(International)Cooperation Base Project(GHJD-2021022).
文摘The high frequency-very high frequency(HF-VHF)frequency band is of significant importance in astronomical observations,with applications studying various phenomena such as space weather,solar radio emissions,planetary eruptions in the solar system,pulsars,transient sources,and reionization of the early universe.This article introduces the HF-VHF frequency band multifunctional radio astronomical terminal system based on a dual-channel high-speed acquisition board with a frequency observation range of 1-250 MHz and a sampling rate of 500 Msps(Mega samples per second).The maximum quantization bit of the system is 14 bits,with a maximum time resolution of 0.1 s and a maximum spectral resolution of 16 kHz.The system combines spectral analysis of solar radio signals and recording of time-domain data of signals interfering with long baselines,and adopts a server-client separation mode to allow remote operation with separate permissions.It is used in the China-Malaysia joint astronomy project,which can carry out single-site observation of solar radio signals as well as interferometric observation of signals from multiple sites.
文摘Arc welding converter (AWC) power source is a nonlinear and discrete abnormal system. It is difficult to get the accurate analytic solution in theory. In this paper, an average state equation of the system is established by means of state space analysis method. The mathematics model of the reverse converter is gotten after the average equation of the system is linearized. The model is a two ranks oscillation link. With the parameters of the AWC, when the condition of (1/RC) 2 >>4/LC is available, the mathematics model may be simplified to a serial structure which includes a integral link and a one rank inertia link. On the basis of this, it can be analyzed and rectified in frequency domain, then some groups of reality rectification parameters are gotten around the theory rectification parameters. These groups of parameters are taken to do the resistance load experiment and welding technology experiment. The result of experiment accords with the theory analysis result. This paper also provides some practical analysis of the model under the large signal process such as the sudden opening of the load, short circuit, turning on and turning off the machine. The result of the research shows that the power source system of AWC can be analyzed and rectified by the frequency domain analysis method in the engineering. The deduced mathematics model of small signal average frequency domain shows the basic characteristics of the system, and the structure parameters of the system is formed by R, L, C and switching ratio D. The model is very simple and clear, and it can be used to analyze and design the power source system of AWC and it can also be used to direct the regulation for dynamic characteristics of the system.
基金This work was supported by Research Fund for the Doctoral Programof Higher Education(RFDP)(No.20010698015).
文摘This paper presents a novel algorithm of fault location for transmission line.Solving the network spectrum equations for different frequencies the fault can be located accurately by this algorithm with one terminal data of voltage and current,and the identified parameters,such as fault distance, fault resistance,and opposite terminal system resistance and inductance.The algorithm eliminates the influence of the opposite system impedance on the fault location accuracy,which causes the main error in traditional fault location methods using one terminal data.A method of calculating spectrum from sampled data is also proposed.EMTP simulations show the validity and higher accuracy of the fault location algorithm compared to the existing ones based on one terminal data.
基金supported in part by the National Natural Science Foundation of China under Grant No.U1766202,51907179 and 51977197.
文摘The mode-based damping torque analysis(M-DTA)method for studying the effect of an external controller on power system low-frequency oscillations is proposed in this paper.First,based on the interconnection model between the system and the controller in the frequency domain,the oscillation loop corresponding to the electromechanical oscillation mode is built,and then the mode-based damping torque of the controller can be calculated.Then,the application of the M-DTA method in the power system is illustrated.The derivation shows that in the single-machine infinite-bus power system,the M-DTA method is completely equivalent to the classical damping torque analysis(C-DTA)method.In the multi-machine power system,the mode-based damping torque directily reflects the effect of the controller on the oscillation mode,overcoming the shortcomings of the C-DTA method in which there is no direct correspondence between the damping torque and the oscillation mode.By deriving the relationship with the residue index,the M-DTA method shows higher accuracy than the residue method in applications,such as controller parameter adjustment.Finally,two example power systems are presented to demonstrate the application of the proposed M-DTA method.Index Terms-Electromechanical oscillation mode,FACTS,interconnection model in the frequency domain,mode-based damping torque analysis(M-DTA),power system low-frequency oscillation,PSS,residue method.
文摘新能源接入现有电网将弱化系统的频率稳定性。充分利用调频资源对提升电网稳定性具有重要意义。火电作为当前调频主要资源有着复杂多变的特性,在不同工况下调频能力也会不同;且随着渗透率提高,传统的下垂控制调频方式逐渐不能满足控制要求。因此,提出一种储能–火电互补频率控制策略,设计了随频率变化自适应调节的出力比重系数,实现了储能出力的自适应调整,并将线性自抗扰控制(Linear active disturbance rejection control,LADRC)应用于火电机组的控制,通过频域法分析典型工业控制对象的LADRC参数调节规律。仿真结果表明,相较于传统下垂控制策略,所提出的储能–火电互补频率控制策略使系统的频率偏差最大值与稳态偏差值显著降低,并且有更好的储能恢复效果。
基金supported by National Natural Science Foundation of China(No.51577124,No.51877148)National Key Research and Development Program of China(SQ2023YFE0198100)。
文摘Power inverter adopting virtual synchronous generator(VSG)control can provide inertia support for distributed generation systems.However,it cannot take into account the dynamic regulation characteristics of frequency.Thus,when the system encounters a sudden change in load or disturbance,the dynamic process of frequency regulation will be greatly influenced.In view of this issue,an improved VSG control strategy based on a coordinated self-adaptive(CSA)method is proposed.The time domain analysis method is used to study the influences of virtual inertia and damping parameter perturbation on the system steady and dynamic performances.Furthermore,in order to make the control strategy suitable for large load changes and suppress frequency variations beyond the limit,the secondary frequency modulation is introduced into the control loop.Through the coordinated adaptive control of virtual inertia,virtual damping and frequency modulation,the dynamic performance of vSG frequency regulation can be obviously improved.Simulation and experiment results have verified the effectiveness of the proposed CSA control strategy.
基金supported by the National Natural Science Foundation of China (50909088, 51010009)Science & Technology Development Project of Qingdao (09-1-3-18-jch)Program for New Century Excellent Talents in University (NCET-10-0762)
文摘The present paper develops a new method for damage localization and severity estimation based on the employment of modal strain energy. This method is able to determine the damage locations and estimate their severities, requiring only the information about the changes of a few lower natural frequencies. First, a damage quantification method is formulated and iterative approach is adopted for determining the damage extent. Then a damage localization algorithm is proposed, in which a damage indicator is formulated where unity value corresponds to the true damage scenario. Finally, numerical studies and model tests are conducted to demonstrate the effectiveness of the developed algorithm.