期刊文献+
共找到31篇文章
< 1 2 >
每页显示 20 50 100
High Sensitivity Digital Instantaneous Frequency Measurement Receiver for Precise Frequency Analysis
1
作者 Bilal Abdulhamed Chien-In Henry Chen 《Journal of Computer and Communications》 2024年第1期177-190,共14页
There are numerous applications, such as Radar, that leverage wideband technology. However, the presence of noise introduces certain limitations and challenges. It is crucial to harness wideband technology for applica... There are numerous applications, such as Radar, that leverage wideband technology. However, the presence of noise introduces certain limitations and challenges. It is crucial to harness wideband technology for applications demanding the rapid and precise transmission of diverse information from one point to another within a short timeframe. The ability to report a signal without tuning within the input bandwidth stands out as one of the advantages of employing a digital wideband receiver. As indicated, a digital wideband receiver plays a pivotal role in achieving high precision and accuracy. The primary distinction between Analog and Digital Instantaneous Frequency Measurement lies in the fact that analog Instantaneous Frequency Measurement (IFM) receivers have traditionally covered extensive input bandwidths, reporting one accurate frequency per short pulse. In the contemporary landscape, digital IFM systems utilize high-sampling-rate Analog-to-Digital Converters (ADC) along with Hilbert transforms to generate two output channels featuring a 90-degree phase shift. This paper explores the improvement of sensitivity in current digital IFM receivers. The optimization efforts target the Hilbert transform and autocorrelations architectures, aiming to refine the system’s ability to report fine frequencies within a noisy wide bandwidth environment, thereby elevating its overall sensitivity. 展开更多
关键词 Digital Wideband Receiver Instantaneous frequency Measurement (IFM) Receiver
下载PDF
A super-high resolution frequency standard measuring approach based on phase coincidence characteristics between signals 被引量:13
2
作者 李智奇 周渭 +1 位作者 陈发喜 刘晨光 《Chinese Physics B》 SCIE EI CAS CSCD 2010年第9期287-290,共4页
A method for super high resolution comparison measurement is proposed in this paper with a comparison between the frequency standards of different nominal frequencies, which is based on phase coincidence detection of ... A method for super high resolution comparison measurement is proposed in this paper with a comparison between the frequency standards of different nominal frequencies, which is based on phase coincidence detection of the two compared signals. It utilizes the regular phase shift characteristics between the signals. The resolution of the measurement approach can reach 10^-13/s at 5 MHz, and the self-calibration resolution can achieve 10^-14/s in the comparison between 10 MHz and 100 MHz, or even can reach 10^-15/s in the comparison between 10 MHz and 190 MHz. This method implies significant progress in the development of the high precision frequency standard comparison technology. 展开更多
关键词 frequency measurement RESOLUTION phase coincidence equivalent phase comparison frequency
下载PDF
First Evaluation and Frequency Measurement of the Strontium Optical Lattice Clock at NIM 被引量:13
3
作者 林弋戈 王强 +7 位作者 李烨 孟飞 林百科 臧二军 孙震 房芳 李天初 方占军 《Chinese Physics Letters》 SCIE CAS CSCD 2015年第9期17-20,共4页
An optical lattice clock based on 87Sr is built at National Institute of Metrology (NIM) of China. The systematic frequency shifts of the clock are evaluated with a total uncertainty of 2.3×10-16. To measure it... An optical lattice clock based on 87Sr is built at National Institute of Metrology (NIM) of China. The systematic frequency shifts of the clock are evaluated with a total uncertainty of 2.3×10-16. To measure its absolute frequency with respect to NIM's cesium fountain clock NIM5, the frequency of a flywheel H-maser of NIM5 is transferred to the Sr laboratory through a 50-kin-long fiber. reference frequency of this H-maser, is used for the optical this Sr clock is measured to be 429228004229873.7(1.4)Hz. A fiber optical frequency comb, phase-locked to the frequency measurement. The absolute frequency of 展开更多
关键词 AOM First Evaluation and frequency Measurement of the Strontium Optical Lattice Clock at NIM
下载PDF
Precise determination of characteristic laser frequencies by an Er-doped fiber optical frequency comb 被引量:3
4
作者 曹士英 韩羿 +2 位作者 丁永今 林百科 方占军 《Chinese Physics B》 SCIE EI CAS CSCD 2022年第7期327-335,共9页
Femtosecond optical frequency combs correlate the microwave and optical frequencies accurately and coherently.Therefore,any optical frequency in visible to near-infrared region can be directly traced to a microwave fr... Femtosecond optical frequency combs correlate the microwave and optical frequencies accurately and coherently.Therefore,any optical frequency in visible to near-infrared region can be directly traced to a microwave frequency.As a result,the length unit“meter”is directly related to the time unit“second”.This paper validates the capability of the national wavelength standards based on a home-made Er-doped fiber femtosecond optical frequency comb to measure the laser frequencies ranging from visible to near-infrared region.Optical frequency conversion in the femtosecond optical frequency comb is achieved by combining spectral broadening in a highly nonlinear fiber with a single-point frequencydoubling scheme.The signal-to-noise ratio of the beat notes between the femtosecond optical frequency comb and the lasers at 633,698,729,780,1064,and 1542 nm is better than 30 d B.The frequency instability of the above lasers is evaluated by using a hydrogen clock signal with a instability of better than 1×10^(-13)at 1-s averaging time.The measurement is further validated by measuring the absolute optical frequency of an iodine-stabilized 532-nm laser and an acetylenestabilized 1542-nm laser.The results are within the uncertainty range of the international recommended values.Our results demonstrate the accurate optical frequency measurement of lasers at different frequencies using the femtosecond optical frequency comb,which is not only important for the precise and accurate traceability and calibration of the laser frequencies,but also provides technical support for establishing the national wavelength standards based on the femtosecond optical frequency comb. 展开更多
关键词 optical frequency measurement phase lock Er-doped fiber laser fiber optical frequency comb
下载PDF
Precision frequency measurement of 1^S0–3^P1 intercombination lines of Sr isotopes 被引量:3
5
作者 刘辉 高峰 +6 位作者 王叶兵 田晓 任洁 卢本全 徐琴芳 谢玉林 常宏 《Chinese Physics B》 SCIE EI CAS CSCD 2015年第1期208-215,共8页
We report on frequency measurement of the intercombination(5s^2)^1S0–(5s5p)^3P1transition of the four natural isotopes of strontium, including88^Sr(82.58%),87^Sr(7.0%),86^Sr(9.86%), and84^Sr(0.56%). A nar... We report on frequency measurement of the intercombination(5s^2)^1S0–(5s5p)^3P1transition of the four natural isotopes of strontium, including88^Sr(82.58%),87^Sr(7.0%),86^Sr(9.86%), and84^Sr(0.56%). A narrow-linewidth laser that is locked to an ultra-low expansion(ULE) optical cavity with a finesse of 12000 is evaluated at a linewidth of 200 Hz with a fractional frequency drift of 2.8×10^-13 at an integration time of 1 s. The fluorescence collector and detector are specially designed, based on a thermal atomic beam. Using a double-pass acousto-optic modulator(AOM) combined with a fiber and laser power stabilization configuration to detune the laser frequency enables high signal-to-noise ratios and precision saturated spectra to be obtained for the six transition lines, which allows us to determine the transition frequency precisely.The optical frequency is measured using an optical frequency synthesizer referenced to an H maser. Both the statistical values and the final values, including the corrections and uncertainties, are derived for a comparison with the values given in other works. 展开更多
关键词 optical frequency measurement STRONTIUM intercombination transition
下载PDF
A diode laser spectrometer at 634 nm and absolute frequency measurements using optical frequency comb 被引量:1
6
作者 伊林 袁杰 +5 位作者 齐向晖 陈文兰 周大伟 周通 周小计 陈徐宗 《Chinese Physics B》 SCIE EI CAS CSCD 2009年第4期1409-1412,共4页
This paper reports that two identical external-cavity-diode-laser (ECDL) based spectrometers are constructed at 634nm referencing on the hyperfine B-X transition R(80)8-4 of 127I2. The lasers are stabilized on the... This paper reports that two identical external-cavity-diode-laser (ECDL) based spectrometers are constructed at 634nm referencing on the hyperfine B-X transition R(80)8-4 of 127I2. The lasers are stabilized on the Doppler-free absorption signals using the third-harmonic detection technique. The instability of the stabilized laser is measured to be 2.8 × 10^-12 (after 1000 s) by counting the beat note between the two lasers. The absolute optical frequency of the transition is, for the first time, determined to be 472851936189.5 kHz by using an optical frequency comb referenced on the microwave caesium atomic clock. The uncertainty of the measurement is less than 4.9 kHz. 展开更多
关键词 frequency standard optical frequency comb absolute frequency measurement atomicclock
下载PDF
Different Frequency Synchronization Theory and Its Frequency Measurement Practice Teaching Innovation Based on Lissajous Figure Method 被引量:1
7
作者 Xin Geng Songlin Li +2 位作者 Guangming Huang Baoqiang Du Jianhua Chen 《Journal of Beijing Institute of Technology》 EI CAS 2018年第2期198-205,共8页
According to the requirement of multi-parameter time and frequency measurement without frequency normalization,a different frequency synchronization theory is proposed based on Lissajous figure method and the variatio... According to the requirement of multi-parameter time and frequency measurement without frequency normalization,a different frequency synchronization theory is proposed based on Lissajous figure method and the variation lawof Lissajous figure which are used in practice teaching of frequency measurement. The theory can achieve high-precision transmission and comparison of time and frequency and precise locking and tracking of phase and frequency,improve the level of scientific research on time and frequency for postgraduate,and promote practice teaching innovation of time frequency measurement for undergraduate. Utilizing the ratio of horizontal and vertical inflection point of the Lissajous figure,the nominal frequency of the measured signal is precisely calculated.The frequency deviation between the measured frequency and its nominal frequency can be obtained by combining the turning cycle of the Lissajous figure. By observing the phase relationship between the frequency standard signal and the measured signal,the accurate measurement of the frequency is implemented. Experimental results showthat the direct measurement and comparison better than the 10-11 order of magnitude with common frequency source can be finished between any signal frequencies.The frequency measurement method based on the theory has the advantage of simple operation,quick measurement speed,small error,lownoise and high measurement precision. It plays an important role in time synchronization,communications,metrology,scientific research,educational technology practice and equipment and other fields. 展开更多
关键词 Lissajous figure different frequency synchronization frequency measurement
下载PDF
Precision Frequency Measurement of ^(87)Rb 5S_(1/2)(F=2)→5D_(5/2)(F″=4)Two-Photon Transition through a Fiber-Based Optical Frequency Comb
8
作者 夏巍 戴少阳 +3 位作者 张胤 李坤乾 于齐 陈徐宗 《Chinese Physics Letters》 SCIE CAS CSCD 2016年第5期30-34,共5页
The absolute frequency of 87Rb 5S1/2 (F=2)→5D5/2 (F" = 4) two-photon transition at 778nm is measured in an accuracy of 44kHz. A home-made erbium-doped fiber laser frequency comb with frequency stability of 5.0 ... The absolute frequency of 87Rb 5S1/2 (F=2)→5D5/2 (F" = 4) two-photon transition at 778nm is measured in an accuracy of 44kHz. A home-made erbium-doped fiber laser frequency comb with frequency stability of 5.0 × 10-13@1 s is employed for the light source. By using a periodically poled lithium niobate, the femtosecond pulse operating in 1556 nm is frequency-doubled to 778 nm to obtain the direct two-photon transition spectroscopy of thermal rubidium vapor. Through sweeping the carrier envelope offset frequency (fceo), the 5S1/2 (F=2)→5D5/2 (F" = 4) two-photon transition line is clearly resolved and its absolute frequency is determined via the peak-finding of the fitting curve. After the frequency correction, the measured result agrees well with the previous experiment on this transition. The entire potential candidate of optical frequency standard for system configuration is compact and robust, providing a telecommunication applications. 展开更多
关键词 Precision frequency Measurement of in is F=2 on as been Rb 5S F Two-Photon Transition through a Fiber-Based Optical frequency Comb
下载PDF
Instantaneous frequency measurement using two parallel I/Q modulators based on optical power monitoring
9
作者 王创业 宁提纲 +3 位作者 李晶 裴丽 郑晶晶 张景川 《Chinese Physics B》 SCIE EI CAS CSCD 2022年第1期215-220,共6页
A scheme for instantaneous frequency measurement(IFM)using two parallel I/Q modulators based on optical power monitoring is proposed.The amplitude comparison function(ACF)can be constructed to establish the relationsh... A scheme for instantaneous frequency measurement(IFM)using two parallel I/Q modulators based on optical power monitoring is proposed.The amplitude comparison function(ACF)can be constructed to establish the relationship between the frequency of radio frequency(RF)signal and the power ratio of two optical signals output by two I/Q modulators.The frequency of RF signal can be derived by measuring the optical power of the optical signals output by two I/Q modulators.The measurement range and measurement error can be adjusted by controlling the delay amount of the electrical delay line.The feasibility of the scheme is verified,and the corresponding measurement range and measurement error of the system under different delay amounts of the electrical delay line are given.Compared with previous IFM schemes,the structure of this scheme is simple.Polarization devices,a photodetector and an electrical power meter are not used,which reduces the impact of the environmental disturbance on the system and the cost of the system.In simulation,the measurement range can reach 0 GHz-24.5 GHz by adjusting the delay amount of the electrical delay lineτ=20 ps.The measurement error of the scheme is better at low frequency,and the measurement error of low frequency 0 GHz-9.6 GHz can reach-0.1 GHz to+0.05 GHz. 展开更多
关键词 microwave photonics instantaneous frequency measurement optical power monitoring
下载PDF
Switchable instantaneous frequency measurement by optical power monitoring based on DP-QPSK modulator
10
作者 朱昱琳 武蓓蕾 +3 位作者 李晶 王目光 肖世莹 延凤平 《Chinese Physics B》 SCIE EI CAS CSCD 2022年第4期336-347,共12页
We propose and analyze an instantaneous frequency measurement system by using optical power monitoring technique with improved resolution.The primary component adopted in the proposal is a dual-polarization quadrature... We propose and analyze an instantaneous frequency measurement system by using optical power monitoring technique with improved resolution.The primary component adopted in the proposal is a dual-polarization quadrature phase shift keying(DP-QPSK) modulator which is used to modulate the microwave signal that has a designed time delay and phase shifting.The generated optical signal is sent to polarization beam splitter(PBS) in DP-QPSK modulator.Owing to the complementary transmission nature of polarization interference introduced by PBS,the frequency information is converted into the optical power and the relationship between the amplitude comparison function(ACF) and microwave frequency to be measured is established.Thus,the frequency of the microwave signal can be easily measured through monitoring the optical powers of the two output ports of the PBS.Furthermore,by adjusting the direct current(DC) biases of the DP-QPSK modulator instead of changing the electrical delay,the measurement range and resolution can be switched.In this paper,the basic principle of the instantaneous frequency measurement system is derived in detail,and simulation has been performed to investigate the resolution,the measurement range,and the influence of imperfection devices.The proposed scheme is wavelength-independent and its measurement range is switchable,which can avoid the laser wavelength drifting problem and thus greatly increasing the system flexibility. 展开更多
关键词 microwave photonics DP-QPSK modulator instantaneous frequency measurement
下载PDF
Absolutely Direct Frequency Measurement of Two-Photon Transition Using Multi-Peak Fitting Approach
11
作者 戴少阳 李坤乾 +5 位作者 翟跃阳 夏巍 王青 熊炜 齐向晖 陈徐宗 《Chinese Physics Letters》 SCIE CAS CSCD 2017年第1期32-35,共4页
The optical frequency comb has been widely used in precision measurement. In this study, a multi-peak fitting approach is first proposed to fit the two-photon transition spectrum which overlaps with the neighboring tr... The optical frequency comb has been widely used in precision measurement. In this study, a multi-peak fitting approach is first proposed to fit the two-photon transition spectrum which overlaps with the neighboring transition in Rb-87. The multi-peak fitting approach is used to eliminate the frequency shift affected by the neighboring transition. With locking the carrier envelope offset frequency at 1/4 repetition frequency, the transition frequency is measured to be 770569132739.9 +/- 5.8 kHz, which agrees well with the previous result recommended by Comite International des Poids et Mesures. 展开更多
关键词 In Absolutely Direct frequency Measurement of Two-Photon Transition Using Multi-Peak Fitting Approach Rb
下载PDF
A novel high precision Doppler frequency estimation method based on the third-order phase-locked loop
12
作者 Tao Deng Mao-Li Ma +1 位作者 Qing-Hui Liu Ya-Jun Wu 《Research in Astronomy and Astrophysics》 SCIE CAS CSCD 2021年第9期83-90,共8页
In deep space exploration,many engineering and scientific requirements require the accuracy of the measured Doppler frequency to be as high as possible.In our paper,we analyze the possible frequency measurement points... In deep space exploration,many engineering and scientific requirements require the accuracy of the measured Doppler frequency to be as high as possible.In our paper,we analyze the possible frequency measurement points of the third-order phase-locked loop(PLL)and find a new Doppler measurement strategy.Based on this finding,a Doppler frequency measurement algorithm with significantly higher measurement accuracy is obtained.In the actual data processing,compared with the existing engineering software,the accuracy of frequency of 1 second integration is about 5.5 times higher when using the new algorithm.The improved algorithm is simple and easy to implement.This improvement can be easily combined with other improvement methods of PLL,so that the performance of PLL can be further improved. 展开更多
关键词 Doppler frequency measurement:deep space exploration:carrier tracking:phase locked loop:high precision
下载PDF
MEASUREMENT OF AMPLITUDE AND DELAY OF STIMULUS FREQUENCY OTOACOUSTIC EMISSIONS
13
作者 Tianying Ren Jiefu Zheng +1 位作者 Wenxuan He Alfred L. Nuttall 《Journal of Otology》 2013年第1期57-62,共6页
Although stimulus frequency otoacoustic emissions (SFOAEs) have been used as a non-invasive measure of cochlear mechanics, clinical and experimental application of SFOAEs has been limited by difficulties in accurately... Although stimulus frequency otoacoustic emissions (SFOAEs) have been used as a non-invasive measure of cochlear mechanics, clinical and experimental application of SFOAEs has been limited by difficulties in accurately deriving quantitative information from sound pressure measured in the ear canal. In this study, a novel signal processing method for multicomponent analysis (MCA) was used to measure the amplitude and delay of the SFOAE. This report shows the delay-frequency distribution of the SFOAE measured from the human ear. A low level acoustical suppressor near the probe tone significantly suppressed the SFOAE, strongly indicating that the SFOAE was generated at characteristic frequency locations. Information derived from this method may reveal more details of cochlear mechanics in the human ear. 展开更多
关键词 MEASUREMENT OF AMPLITUDE AND DELAY OF STIMULUS frequency OTOACOUSTIC EMISSIONS MCA SDC LDC Figure
下载PDF
Technical Research for Detector of Grain Moisture Content Based on Error Compensation 被引量:1
14
作者 Dong Yu-de Yang Xian-long +3 位作者 Ye Fei Pan Kai Jin Xing-chi Shi De-cai 《Journal of Northeast Agricultural University(English Edition)》 CAS 2014年第3期76-83,共8页
According to the existing method including testing the frequency and establishing the relationship between moisture content and frequency, a corresponding instrument was designed. In order to further improve the accur... According to the existing method including testing the frequency and establishing the relationship between moisture content and frequency, a corresponding instrument was designed. In order to further improve the accuracy and rapidity of the system, a new approach to describe the relationship between the measurement error and the temperature was proposed. The error band could be obtained and divided into several parts(based on the range of temperature) to indicate the error value that should compensate the grain moisture content for the changes in temperature. By calculating the error band at the maximum and the minimum operating temperatures, as well as by determining the error compensation value from the error band based on the measurement moisture content, the final effective result was derived. 展开更多
关键词 grain moisture content frequency measurement micro controller unit error compensation mathematical model
下载PDF
New design of high-precision oven controlled crystal oscillator 被引量:1
15
作者 董绍锋 杜保强 周渭 《Journal of Beijing Institute of Technology》 EI CAS 2012年第3期362-369,共8页
Combining oven controlled technique,digital compensation,high-resolution frequency difference measurement and self-calibration technique,a new design method of precise oven controlled crystal oscillator(OCXO) is pro... Combining oven controlled technique,digital compensation,high-resolution frequency difference measurement and self-calibration technique,a new design method of precise oven controlled crystal oscillator(OCXO) is proposed.Fine compensation is made in the vicinity of the crystal temperature inflection point by using the non-real-time temperature compensation strategy,and self-calibration system is integrated in the crystal.The method improves the digital compensated phase noise,simplifies the traditional OCXO development system,reduces the cost and shortens the developing cycle.Experiment results show that with a standard reference signal and self-calibration updated data,the oscillator can work stable and achieve its best performence.The performance index of crystal oscillator had an improvement with one to two orders of magnitude on the basis of original technical index.The method is widely used in the improvement of high-end crystal oscillator and atomic clock. 展开更多
关键词 crystal oscillator temperature compensation non-real-time control frequency difference measurement self-calibration
下载PDF
Design and Implementation of a Cueing Wideband Digital EW Receiver 被引量:4
16
作者 祝俊 唐斌 《Journal of Electronic Science and Technology of China》 2006年第3期257-264,共8页
A cueing wideband digital Electronic Warfare (EW) receiver is presented. The proposed receiver, which is to measure the instantaneous frequency and bandwidth of the intercept short-duration pulse radar signals that ... A cueing wideband digital Electronic Warfare (EW) receiver is presented. The proposed receiver, which is to measure the instantaneous frequency and bandwidth of the intercept short-duration pulse radar signals that cue and match the corresponding ones, meets the requirements of good sensitivity and dynamic range for EW and can save hardware resources greatly as well. In addition, real-time signal processing, which is the main bottleneck for covering a wide instantaneous frequency band for EW receiver, is better solved in the proposed design structure. The highly efficient implementation and good parameter estimation algorithms are proposed as welL Theoretical analysis and experimental results show that this structure is feasible. 展开更多
关键词 wideband digital EW receivers frequency and bandwidth measurement DDC parameter estimation FPGA DSP
下载PDF
Equivalent comparison and analysis between different nominal frequencies
17
作者 李智奇 韦中 +2 位作者 周渭 宋慧敏 鲁伟昊 《Chinese Physics B》 SCIE EI CAS CSCD 2014年第11期238-241,共4页
We analyze the phenomena of phase group synchronization between the different nominal frequency signals and propose a new theory of the equivalent comparison between them. The exact expression of the equivalent compar... We analyze the phenomena of phase group synchronization between the different nominal frequency signals and propose a new theory of the equivalent comparison between them. The exact expression of the equivalent comparison is deduced. High resolution frequency measurement and phase comparison can be realized using this theory with the divider. For avoiding the frequency mixing, multiplication and synthesis, the system phase noise is improved and the higher resolution comparison and measurement are achieved between the different nominal frequencies by theory. 展开更多
关键词 phase difference group synchronization equivalent comparison frequency measurement
下载PDF
COMPLETE PARAMETER MEASUREMENT FOR MIMO BISTATIC RADAR WITHOUT SYNCHRONIZATION
18
作者 Zhang Yongshun Zhao Guoqing +1 位作者 Guo Yiduo Wang Buhong 《Journal of Electronics(China)》 2010年第6期742-748,共7页
In order to measure the range, angle, and Doppler frequency of the target without any synchronization in the bistatic radar, a novel complete parameter estimation method based on separability of a pair of Linear Frequ... In order to measure the range, angle, and Doppler frequency of the target without any synchronization in the bistatic radar, a novel complete parameter estimation method based on separability of a pair of Linear Frequency Modulation (LFM) signal is presented. The Doppler fre-quency is measured by the time difference between two peak positions corresponding to the positive and the negative LFM return signal respectively. Direction Of Departures (DODs) and Direction Of Arrivals (DOAs) of the target are estimated by constructing a special eigenmatrix in which the es-timated angles can be extracted from the eigenvalue or the eigenvector. The target position can be located in the presence of the estimated DODs, DOAs and the signal delay difference between the echo and the directive wave signal in Multiple Input Multiple Output (MIMO) bistatic radar without any synchronization. The correctness and effectiveness of the proposed method are verified by the computer simulation. 展开更多
关键词 Multiple Input Multiple Output (MIMO) radar Bistatic radar Doppler frequency measurement Angle estimation Target location
下载PDF
Deciding on a Measure of Effect under Indeterminism
19
作者 Doron J. Shahar 《Open Journal of Epidemiology》 2016年第4期198-232,共35页
Estimating causal effects is a principal goal in epidemiology and other branches of science. Nonetheless, what constitutes an effect and which measure of effect is pre-ferred are unsettled questions. I argue that, und... Estimating causal effects is a principal goal in epidemiology and other branches of science. Nonetheless, what constitutes an effect and which measure of effect is pre-ferred are unsettled questions. I argue that, under indeterminism, an effect is a change in the tendency of the outcome variable to take each of its values, and then present a critical analysis of commonly used measures of effect and the measures of frequency from which they are calculated. I conclude that all causal effects should be quantified using a unifying measure of effect called the log likelihood ratio (which is the log probability ratio when the outcome is a discrete variable). Furthermore, I suggest that effects should be estimated for all causal contrasts of the causal variable (i.e., expo-sure), on all values of the outcome variable, and for all time intervals between the cause and the outcome. This goal should be kept in mind in practical approximations. 展开更多
关键词 Measure of Effect Measure of frequency INDETERMINISM CAUSATION Causal Diagram
下载PDF
Instantaneous frequency analysis of broadband LFM signals by photonics-assisted equivalent frequency sampling 被引量:4
20
作者 周悦雯 张方正 潘时龙 《Chinese Optics Letters》 SCIE EI CAS CSCD 2021年第1期106-110,共5页
We propose a photonics-assisted equivalent frequency sampling(EFS)method to analyze the instantaneous frequency of broadband linearly frequency modulated(LFM)microwave signals.The proposed EFS method is implemented by... We propose a photonics-assisted equivalent frequency sampling(EFS)method to analyze the instantaneous frequency of broadband linearly frequency modulated(LFM)microwave signals.The proposed EFS method is implemented by a photonic scanning receiver,which is operated with a frequency scanning rate slightly different from the repetition rate of the LFM signals.Compared with the broadband LFM signal analysis based on temporal sampling,the proposed method avoids the use of high-speed analog to digital converters,and the instantaneous frequency acquisition realized by frequency-to-time mapping is also simplified since real-time Fourier transformation is not required.Feasibility of the proposed method is verified through an experiment,in which frequency analysis of Kα-band LFM signals with a bandwidth up to 3 GHz is demonstrated with a moderate sampling rate of 100 MSa/s.The proposed method is highly demanded for analyzing the instantaneous frequency of broadband LFM signals used in radar and electronic warfare systems. 展开更多
关键词 frequency measurement equivalent frequency sampling microwave photonics
原文传递
上一页 1 2 下一页 到第
使用帮助 返回顶部