期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
Distributed Stochastic Scheduling of Massive Backup Batteries in Cellular Networks for Operational Reserve and Frequency Support Ancillary Services
1
作者 Kun Li Jiakun Fang +3 位作者 Xiaomeng Ai Shichang Cui Rongkang Zhao Jinyu Wen 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2024年第2期393-404,共12页
Base station(BS)backup batteries(BSBBs),with their dispatchable capacity,are potential demand-side resources for future power systems.To enhance the power supply reliability and post-contingency frequency security of ... Base station(BS)backup batteries(BSBBs),with their dispatchable capacity,are potential demand-side resources for future power systems.To enhance the power supply reliability and post-contingency frequency security of power systems,we propose a two-stage stochastic unit commitment(UC)model incorporating operational reserve and post-contingency frequency support provisions from massive BSBBs in cellular networks,in which the minimum backup energy demand is considered to ensure BS power supply reliability.The energy,operational reserve,and frequency support ancillary services are co-optimized to handle the power balance and post-contingency frequency security in both forecasted and stochastic variable renewable energy(VRE)scenarios.Furthermore,we propose a dedicated and scalable distributed optimization framework to enable autonomous optimizations for both dispatching center(DC)and BSBBs.The BS model parameters are stored and processed locally,while only the values of BS decision variables are required to upload to DC under the proposed distributed optimization framework,which safeguards BS privacy effectively.Case studies on a modified IEEE 14-bus system demonstrate the effectiveness of the proposed method in promoting VRE accommodation,ensuring post-contingency frequency security,enhancing operational economics,and fully utilizing BSBBs'energy and power capacity.Besides,the proposed distributed optimization framework has been validated to converge to a feasible solution with near-optimal performance within limited iterations.Additionally,numerical results on the Guangdong 500 kV provincial power system in China verify the scalability and practicality of the proposed distributed optimization framework. 展开更多
关键词 Base station backup battery operational reserve frequency security distributed optimization PRIVACY
原文传递
Integrated Frequency-constrained Scheduling Considering Coordination of Frequency Regulation Capabilities from Multi-source Converters
2
作者 Jiaming Li Ying Qiao +3 位作者 Zongxiang Lu Wei Ma Xin Cao Rongfu Sun 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2024年第1期261-274,共14页
As the proportion of renewable energy(RE)increases,the inertia and the primary frequency regulation(FR)capability of the power system decrease.Thus,ensuring frequency security in the scheduling model has become a new ... As the proportion of renewable energy(RE)increases,the inertia and the primary frequency regulation(FR)capability of the power system decrease.Thus,ensuring frequency security in the scheduling model has become a new technical requirement in power systems with a high share of RE.Due to a shortage of conventional synchronous generators,the frequency support of multi-source converters has become an indispensable part of the system frequency resources,especially variable-speed wind turbine generation(WTG)and battery energy storage(BES).Quantitative expression of the FR capability of multi-source converters is necessary to construct frequency-constrained scheduling model.However,the frequency support performance of these converter-interfaced devices is related to their working states,operation modes,and parameters,and the complex coupling of these factors has not been fully exploited in existing models.In this study,we propose an integrated frequency-constrained scheduling model considering the coordination of FR capabilities from multi-source converters.Switchable FR control strategies and variable FR parameters for WTG with or without reserved power are modeled,and multi-target allocation of BES capacity between tracking dispatch instruction and emergency FR is analyzed.Then,the variable FR capabilities of WTG and BES are embedded into the integrated frequency-constrained scheduling model.The nonlinear constraints for frequency security are precisely linearized through an improved iteration-based strategy.The effectiveness of the proposed model is verified in a modified IEEE 24-bus standard system.The results suggest that the coordinated participation of BES and WTG in FR can effectively reduce the cost of the scheduling model while meeting frequency security constraints. 展开更多
关键词 Battery energy storage(BES) wind turbine generation(WTG) frequency regulation(FR) frequency security power system scheduling
原文传递
Optimal Auxiliary Frequency Control of Wind Turbine Generators and Coordination with Synchronous Generators 被引量:12
3
作者 Ming Sun Yong Min +3 位作者 Lei Chen Kaiyuan Hou Deming Xia Hangyin Mao 《CSEE Journal of Power and Energy Systems》 SCIE CSCD 2021年第1期78-85,共8页
Auxiliary frequency control of a wind turbine generator(WTG) has been widely used to enhance the frequencysecurity of power systems with high penetration of renewableenergy. Previous studies recommend two types of con... Auxiliary frequency control of a wind turbine generator(WTG) has been widely used to enhance the frequencysecurity of power systems with high penetration of renewableenergy. Previous studies recommend two types of control schemes,including frequency droop control and emulated inertia control,which simulate the response characteristics of the synchronousgenerator (SG). This paper plans to further explore the optimalauxiliary frequency control of the wind turbine based on previousresearch. First, it is determined that the virtual inertia control haslittle effect on the maximum rate of change of frequency (MaxROCOF)if the time delay of the control link of WTG is taken intoconsideration. Secondly, if a WTG operates in maximum powerpoint tracking (MPPT) mode and uses the rotor deceleration forfrequency modulation, its optimal auxiliary frequency control willcontain only droop control. Furthermore, if the droop control isproperly delayed, better system frequency response (SFR) willbe obtained. The reason is that coordination between the WTGand SG is important for SFR when the frequency modulationcapability of the WTG is limited. The frequency modulationcapability of the WTG is required to be released more properly.Therefore, when designing optimal auxiliary frequency controlfor the WTG, a better control scheme is worth further study. 展开更多
关键词 frequency droop control power system frequency security rate of change of frequency(ROCOF) virtual inertia control wind turbine generator auxiliary frequency control
原文传递
Practical Realization of Optimal Auxiliary Frequency Control Strategy of Wind Turbine Generator 被引量:1
4
作者 Ming Sun Yong Min +4 位作者 Xuejun Xiong Lei Chen Le Zhao Yuyao Feng Bingran Wang 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2022年第3期617-626,共10页
Adding the auxiliary frequency control function to the wind turbine generator(WTG)is a solution to the frequency security problem of the power system caused by the replacement of the synchronous generator(SG)by the WT... Adding the auxiliary frequency control function to the wind turbine generator(WTG)is a solution to the frequency security problem of the power system caused by the replacement of the synchronous generator(SG)by the WTG.The auxiliary frequency control using rotor kinetic energy is an economical scheme because the WTG still runs at the maximum power point during normal operation.In this paper,the functional optimization model of the auxiliary frequency control strategy of WTG is established.The optimal auxiliary frequency control strategy is obtained by solving the model numerically.As for the practical realization of the control strategy,the coordination of the auxiliary frequency control with the maximum power point tracking(MPPT)control is studied.The practical auxiliary frequency control strategy is modified to adapt to different power disturbances in the system,and the parameter setting method is also proposed.The sensitivity of system frequency to control parameters is studied.Finally,the simulation results verify the effectiveness and practicability of the proposed control strategy. 展开更多
关键词 Power system frequency security wind turbine generator auxiliary frequency control rotor kinetic energy energy constraint
原文传递
Development approach of a programmable and open software package for power system frequency response calculation 被引量:1
5
作者 Yuzheng Xie Hengxu Zhang +1 位作者 Changgang Li Huadong Sun 《Protection and Control of Modern Power Systems》 2017年第1期189-198,共10页
Dynamic behaviour of frequency is crucial for power system operation and control.Several frequency response models have been proposed to reveal frequency dynamics from different aspects.A comprehensive software packag... Dynamic behaviour of frequency is crucial for power system operation and control.Several frequency response models have been proposed to reveal frequency dynamics from different aspects.A comprehensive software package incorporating major frequency response models is needed for analysis and control of power system frequency dynamics.In this paper,an approach for developing a programmable and open software package for frequency response studies is proposed.The framework of the package is extendable with reduced frequency response models.Essential models for frequency response study are included,e.g.,generator,load,and under-frequency load shedding(UFLS).The provided application program interfaces(APIs)enable simulation with high-level languages by calling dynamic link library and makes the package programmable.An advanced application module is developed for quantitative assessment of transient frequency deviation.APIs can also be used for model extension and secondary development.To demonstrate the usage of the package,several examples are illustrated to explain how to perform simulations with the package,and to perform advanced applications using scripting with the provided APIs. 展开更多
关键词 frequency response frequency control Software engineering Under-frequency load shedding Transient frequency deviation security Power systems
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部