Introduction: Anthropometry applied to newborns is a reliable indicator of the quality of fetal growth. The latter is influenced by genetic, racial and nutritional factors varying from one population to another, expla...Introduction: Anthropometry applied to newborns is a reliable indicator of the quality of fetal growth. The latter is influenced by genetic, racial and nutritional factors varying from one population to another, explaining why a standard cannot be applied to all populations. Research question: should the Caucasian frame of reference be dogmatically applied in our African context? Multicenter studies are therefore necessary;hence the interest of this work, the main objective of which was to describe the anthropometric profile of full-term newborns in the city of Douala. Methodology: We carried out a cross-sectional study with an analytical aim and prospective data collection in the maternity wards of the Douala General Hospital, Laquintinie Hospital, District hospitals of Deido, Nylon and Bonassama over a period of 4 months (January to April 2020). We were interested in any newborn, born alive, vaginally or by cesarean section, seen in the first 24 hours from a full-term single-fetal pregnancy whose mother had given consent. We excluded newborns whose term was unclear and those with congenital malformations or signs of embryo-foetopathy. Data collection was done using structured and pre-tested survey sheets. The study variables were obstetric and anthropometric. Statistical analyzes were carried out with CS Pro 7.3 and SPSS version 25.0 software. The Student, Chi-square and Fischer tests were used to compare the means of the variables, the percentages with a significance threshold P value Results: During the study period, 305 full-term newborns were included, divided into 172 boys and 133 girls. The average anthropometric parameters of the full-term newborn in the city of Douala were: average weight: 3305 grams, average height: 49.8 centimeters, average head circumference: 34.6 centimeters, average upper arm circumference: 11.3 centimeters, circumference average thoracic: 32.8 centimeters. The percentile distribution showed a 10th percentile at 2656 grams and a 90th percentile at 3966 grams for weight defining the limits for small-for-gestational-age neonates and macrosomes. Conclusion: The anthropometric data of the full-term newborn in the city of Douala were: an average weight of 3305.4 grams, an average height of 49.8 centimeters, an average head circumference of 34.2 centimeters, an average upper arm circumference of 11.3 centimeters, and an average thoracic circumference of 32.8 centimeters with higher valuesin male newborns.展开更多
为实现远距离、高可靠性传输,并减小复杂度,对Camera Link Full接口数据的HD-SDI传输显示进行了深入研究。采用FPGA作为核心处理器,考虑相机输出具有多种帧频,采取帧频检测及充分降频策略,并通过3个SRAM进行缓存以实现帧频转换,以满足HD...为实现远距离、高可靠性传输,并减小复杂度,对Camera Link Full接口数据的HD-SDI传输显示进行了深入研究。采用FPGA作为核心处理器,考虑相机输出具有多种帧频,采取帧频检测及充分降频策略,并通过3个SRAM进行缓存以实现帧频转换,以满足HD-SDI帧频25Hz的要求。考虑到SRAM数据宽度,采取FIFO行缓存策略将Camera Link Full80输出的10tap、80bits图像数据转换成单通道的8bits图像数据。最后,完成系统设计并进行实验验证。实验结果表明:系统实现了图像数据从50Hz、100Hz、500 Hz等多种帧频的Camera Link Full80到25帧HD-SDI接口1080i的格式转换及实时显示,且图像层次丰富,无失真。展开更多
This paper investigates the effect of atomic disorder on the electronic structure, magnetism, and half-metallicity of full-Heusler Co2FeSi alloy by using the full-potential linearized augmented plane wave method withi...This paper investigates the effect of atomic disorder on the electronic structure, magnetism, and half-metallicity of full-Heusler Co2FeSi alloy by using the full-potential linearized augmented plane wave method within the generalized gradient approximation (GGA) and GGA-kU schemes. It considers three types of atomic disorders in Co2FeSi alloy: the Co-Fe, Co-Si, and Fe-Si disorders. Total energy calculations show that of the three types of disorders, the Fe-Si disorder is more likely to occur. It finds that for the Co Si disorder, additional states appear in the minority band-gap at the EF and the half-metallcity is substantially destroyed, regardless of the disorder level. On the other hand, the Co-Fe and Fe-Si disorders have little effect on the half-metallicity at a low disorder level. When increasing the disorder levels, the half-metallcity is destroyed at about 9 % of the Co-Fe disorder level, while that stays at 25 % of the Fe-Si disorder level.展开更多
目的探讨全院性医学影像存栏和通信系统(Full PACS)在医院临床工作中的应用价值。方法采用中间数据库接口方式实现医院信息系统(HIS)及各种临床信息系统与PACS完全整合。结果 Full PACS实现了双屏调阅多种检查、多次检查、多个序列或多...目的探讨全院性医学影像存栏和通信系统(Full PACS)在医院临床工作中的应用价值。方法采用中间数据库接口方式实现医院信息系统(HIS)及各种临床信息系统与PACS完全整合。结果 Full PACS实现了双屏调阅多种检查、多次检查、多个序列或多个时相的影像资料同时浏览;实现了实时影像测量、缩小或放大、调窗及数据统计等后处理功能。结论 Full PACS的顺利运行将为电子病历、医疗区域化、社会保险网络化打下坚实基础。展开更多
为了探究Mn_(2)CrZ(Z=Al,Ga)材料的性质,预测其用途,采用基于密度泛函的第一性原理方法,用Materials Studio 6.0计算了full-Heusler合金Mn_(2)CrAl和Mn_(2)CrGa的磁性、半金属性和力学性能。通过建模和几何优化,得到了它们的最优化晶格...为了探究Mn_(2)CrZ(Z=Al,Ga)材料的性质,预测其用途,采用基于密度泛函的第一性原理方法,用Materials Studio 6.0计算了full-Heusler合金Mn_(2)CrAl和Mn_(2)CrGa的磁性、半金属性和力学性能。通过建模和几何优化,得到了它们的最优化晶格常数分别为5.77?和6.05?。在几何优化的基础上,分别计算了它们的磁性性质和力学性质,通过对能带结构图和态密度图的分析,得出如下结论:Mn_(2)CrAl为半金属亚铁磁性材料,自旋极化率为88.9%,磁性主要来自于合金内部过渡金属原子的d轨道电子的自旋贡献;Mn_(2)CrGa是普通铁磁体。展开更多
文摘Introduction: Anthropometry applied to newborns is a reliable indicator of the quality of fetal growth. The latter is influenced by genetic, racial and nutritional factors varying from one population to another, explaining why a standard cannot be applied to all populations. Research question: should the Caucasian frame of reference be dogmatically applied in our African context? Multicenter studies are therefore necessary;hence the interest of this work, the main objective of which was to describe the anthropometric profile of full-term newborns in the city of Douala. Methodology: We carried out a cross-sectional study with an analytical aim and prospective data collection in the maternity wards of the Douala General Hospital, Laquintinie Hospital, District hospitals of Deido, Nylon and Bonassama over a period of 4 months (January to April 2020). We were interested in any newborn, born alive, vaginally or by cesarean section, seen in the first 24 hours from a full-term single-fetal pregnancy whose mother had given consent. We excluded newborns whose term was unclear and those with congenital malformations or signs of embryo-foetopathy. Data collection was done using structured and pre-tested survey sheets. The study variables were obstetric and anthropometric. Statistical analyzes were carried out with CS Pro 7.3 and SPSS version 25.0 software. The Student, Chi-square and Fischer tests were used to compare the means of the variables, the percentages with a significance threshold P value Results: During the study period, 305 full-term newborns were included, divided into 172 boys and 133 girls. The average anthropometric parameters of the full-term newborn in the city of Douala were: average weight: 3305 grams, average height: 49.8 centimeters, average head circumference: 34.6 centimeters, average upper arm circumference: 11.3 centimeters, circumference average thoracic: 32.8 centimeters. The percentile distribution showed a 10th percentile at 2656 grams and a 90th percentile at 3966 grams for weight defining the limits for small-for-gestational-age neonates and macrosomes. Conclusion: The anthropometric data of the full-term newborn in the city of Douala were: an average weight of 3305.4 grams, an average height of 49.8 centimeters, an average head circumference of 34.2 centimeters, an average upper arm circumference of 11.3 centimeters, and an average thoracic circumference of 32.8 centimeters with higher valuesin male newborns.
文摘为实现远距离、高可靠性传输,并减小复杂度,对Camera Link Full接口数据的HD-SDI传输显示进行了深入研究。采用FPGA作为核心处理器,考虑相机输出具有多种帧频,采取帧频检测及充分降频策略,并通过3个SRAM进行缓存以实现帧频转换,以满足HD-SDI帧频25Hz的要求。考虑到SRAM数据宽度,采取FIFO行缓存策略将Camera Link Full80输出的10tap、80bits图像数据转换成单通道的8bits图像数据。最后,完成系统设计并进行实验验证。实验结果表明:系统实现了图像数据从50Hz、100Hz、500 Hz等多种帧频的Camera Link Full80到25帧HD-SDI接口1080i的格式转换及实时显示,且图像层次丰富,无失真。
基金supported by the National Natural Science Foundation of China (Grant No 10664005)
文摘This paper investigates the effect of atomic disorder on the electronic structure, magnetism, and half-metallicity of full-Heusler Co2FeSi alloy by using the full-potential linearized augmented plane wave method within the generalized gradient approximation (GGA) and GGA-kU schemes. It considers three types of atomic disorders in Co2FeSi alloy: the Co-Fe, Co-Si, and Fe-Si disorders. Total energy calculations show that of the three types of disorders, the Fe-Si disorder is more likely to occur. It finds that for the Co Si disorder, additional states appear in the minority band-gap at the EF and the half-metallcity is substantially destroyed, regardless of the disorder level. On the other hand, the Co-Fe and Fe-Si disorders have little effect on the half-metallicity at a low disorder level. When increasing the disorder levels, the half-metallcity is destroyed at about 9 % of the Co-Fe disorder level, while that stays at 25 % of the Fe-Si disorder level.
文摘目的探讨全院性医学影像存栏和通信系统(Full PACS)在医院临床工作中的应用价值。方法采用中间数据库接口方式实现医院信息系统(HIS)及各种临床信息系统与PACS完全整合。结果 Full PACS实现了双屏调阅多种检查、多次检查、多个序列或多个时相的影像资料同时浏览;实现了实时影像测量、缩小或放大、调窗及数据统计等后处理功能。结论 Full PACS的顺利运行将为电子病历、医疗区域化、社会保险网络化打下坚实基础。
文摘为了探究Mn_(2)CrZ(Z=Al,Ga)材料的性质,预测其用途,采用基于密度泛函的第一性原理方法,用Materials Studio 6.0计算了full-Heusler合金Mn_(2)CrAl和Mn_(2)CrGa的磁性、半金属性和力学性能。通过建模和几何优化,得到了它们的最优化晶格常数分别为5.77?和6.05?。在几何优化的基础上,分别计算了它们的磁性性质和力学性质,通过对能带结构图和态密度图的分析,得出如下结论:Mn_(2)CrAl为半金属亚铁磁性材料,自旋极化率为88.9%,磁性主要来自于合金内部过渡金属原子的d轨道电子的自旋贡献;Mn_(2)CrGa是普通铁磁体。