As for the application of electronic fuel injection (EFI) system to small gasoline generator set, mechanical speed controller cannot be coupled with EFI system and has the shortcomings of lagged regulation and poor ...As for the application of electronic fuel injection (EFI) system to small gasoline generator set, mechanical speed controller cannot be coupled with EFI system and has the shortcomings of lagged regulation and poor accuracy, a feed-forward control strategy based on load combined with proportional-integral-differential (PID) control strategy was proposed, and a digital speed controller applied to the electrical control system was designed. The detailed control strategy of the controller was intro- duced. The hardware design for the controller and the key circuits of motor driving, current sampling and angular signal captu- ring were given, and software architecture was discussed. Combined with a gasoline generator set mounted with EFI system, the controller parameters were tuned and optimized empirically by hardware in loop and bench test methods. Test results show that the speed deviation of generator set is low and the control system is stable in steady state; In transient state the control system responses quickly, has high stability under mutation loads especially when suddenly apply and remove 100% load, the speed deviation is within 8% of reference speed and the transient time is less than 5 s, satisfying the ISO standard.展开更多
A series connected power semiconductor array, with digital control capability could be used for developing single phase AC regulators or other applications such as AC electronic loads. This technique together with an ...A series connected power semiconductor array, with digital control capability could be used for developing single phase AC regulators or other applications such as AC electronic loads. This technique together with an ordinary gapless transformer could be used to develop a low cost AC voltage regulator (AVR) to provide better or comparable specifications with bulky ferro-resonant AVR types. One primary advantage of the technique is that digital control can be used to minimize harmonics. Commencing with a review of AC voltage regulator techniques for single phase power conditioning systems, an analysis and design aspects of this technique is presented with experimental results for AVRs. Guidelines on how to utilize the technique in a generalized basis is also summarized together with a summary of a technique for achieving harmonic control.展开更多
为解决HID灯的老化及灯的伏安特性变化引起的功率漂移问题,基于Buck降压变换器的平均电流控制模式,设计并制作了一款具有恒功率控制能力的数字控制电子镇流器驱动电路,包含两个控制环路:内电流环路用于维持稳定驱动,外功率环路用于维持...为解决HID灯的老化及灯的伏安特性变化引起的功率漂移问题,基于Buck降压变换器的平均电流控制模式,设计并制作了一款具有恒功率控制能力的数字控制电子镇流器驱动电路,包含两个控制环路:内电流环路用于维持稳定驱动,外功率环路用于维持灯在其使用期间的功率恒定,并根据Buck降压变换器DCM模式下的小信号模型,以PI算法作为数字补偿器,完成补偿环路设计,保证电路输出稳定性。为抑制声共振,该电路结构采用三级式结构的电子镇流器,以低频方波驱动。设计和测试结果表明,该电子镇流器驱动电路可实现450 W的恒功率控制,误差值小于3%。该电子镇流器驱动电路结构简单,可靠性高,可适用于450 W HID灯驱动。展开更多
Time-limited dispatching(TLD)analysis of the full authority digital engine control(FADEC)systems is an important part of the aircraft system safety analysis and a necessary task for the certification of commercial air...Time-limited dispatching(TLD)analysis of the full authority digital engine control(FADEC)systems is an important part of the aircraft system safety analysis and a necessary task for the certification of commercial aircraft and aeroengines.In the time limited dispatch guidance document ARP5107B,a single-fault Markov model(MM)approach is proposed for TLD analysis.However,ARP5107B also requires that the loss of thrust control(LOTC)rate error calculated by applying the single-fault MM must be less than 5%when performing airworthiness certification.Firstly,the sources of accuracy errors in three kinds of MM are analyzed and specified through a case study of the general FADEC system,and secondly a two-fault MM considering maintenance policy is established through analyzing and calculating the expected repair time when two related faults happen.Finally,a specific FADEC system is given to study on the influence factors of accuracy error in the single-fault MM,and the results show that the accuracy error of the single-fault MM decreases with the increase of short or long prescribed dispatch time,and the range values of short time(ST)and long time(LT)are determined to satisfy the requirement of accuracy error within 5%.展开更多
文摘As for the application of electronic fuel injection (EFI) system to small gasoline generator set, mechanical speed controller cannot be coupled with EFI system and has the shortcomings of lagged regulation and poor accuracy, a feed-forward control strategy based on load combined with proportional-integral-differential (PID) control strategy was proposed, and a digital speed controller applied to the electrical control system was designed. The detailed control strategy of the controller was intro- duced. The hardware design for the controller and the key circuits of motor driving, current sampling and angular signal captu- ring were given, and software architecture was discussed. Combined with a gasoline generator set mounted with EFI system, the controller parameters were tuned and optimized empirically by hardware in loop and bench test methods. Test results show that the speed deviation of generator set is low and the control system is stable in steady state; In transient state the control system responses quickly, has high stability under mutation loads especially when suddenly apply and remove 100% load, the speed deviation is within 8% of reference speed and the transient time is less than 5 s, satisfying the ISO standard.
文摘A series connected power semiconductor array, with digital control capability could be used for developing single phase AC regulators or other applications such as AC electronic loads. This technique together with an ordinary gapless transformer could be used to develop a low cost AC voltage regulator (AVR) to provide better or comparable specifications with bulky ferro-resonant AVR types. One primary advantage of the technique is that digital control can be used to minimize harmonics. Commencing with a review of AC voltage regulator techniques for single phase power conditioning systems, an analysis and design aspects of this technique is presented with experimental results for AVRs. Guidelines on how to utilize the technique in a generalized basis is also summarized together with a summary of a technique for achieving harmonic control.
文摘为解决HID灯的老化及灯的伏安特性变化引起的功率漂移问题,基于Buck降压变换器的平均电流控制模式,设计并制作了一款具有恒功率控制能力的数字控制电子镇流器驱动电路,包含两个控制环路:内电流环路用于维持稳定驱动,外功率环路用于维持灯在其使用期间的功率恒定,并根据Buck降压变换器DCM模式下的小信号模型,以PI算法作为数字补偿器,完成补偿环路设计,保证电路输出稳定性。为抑制声共振,该电路结构采用三级式结构的电子镇流器,以低频方波驱动。设计和测试结果表明,该电子镇流器驱动电路可实现450 W的恒功率控制,误差值小于3%。该电子镇流器驱动电路结构简单,可靠性高,可适用于450 W HID灯驱动。
基金supported by the National Natural Science Foundation of China(51705242)Shanghai Sailing Program(16YF1404900)the Fundamental Research Funds for the Central Universities(NS2015072)
文摘Time-limited dispatching(TLD)analysis of the full authority digital engine control(FADEC)systems is an important part of the aircraft system safety analysis and a necessary task for the certification of commercial aircraft and aeroengines.In the time limited dispatch guidance document ARP5107B,a single-fault Markov model(MM)approach is proposed for TLD analysis.However,ARP5107B also requires that the loss of thrust control(LOTC)rate error calculated by applying the single-fault MM must be less than 5%when performing airworthiness certification.Firstly,the sources of accuracy errors in three kinds of MM are analyzed and specified through a case study of the general FADEC system,and secondly a two-fault MM considering maintenance policy is established through analyzing and calculating the expected repair time when two related faults happen.Finally,a specific FADEC system is given to study on the influence factors of accuracy error in the single-fault MM,and the results show that the accuracy error of the single-fault MM decreases with the increase of short or long prescribed dispatch time,and the range values of short time(ST)and long time(LT)are determined to satisfy the requirement of accuracy error within 5%.