电网地磁感应电流影响因素多、情况复杂,考虑各电压等级电网的参数特点,以往的GIC地磁感应电流计算集中在电网最高电压等级线路。交流特高压电网建设使我国电网增加了1 000 k V电压等级,综合考虑线路参数、变压器类型等GIC影响因素,准...电网地磁感应电流影响因素多、情况复杂,考虑各电压等级电网的参数特点,以往的GIC地磁感应电流计算集中在电网最高电压等级线路。交流特高压电网建设使我国电网增加了1 000 k V电压等级,综合考虑线路参数、变压器类型等GIC影响因素,准确计算包括500 k V超高压及1 000 k V特高压的多电压等级电网的GIC是重要研究课题。根据我国500 k V和1 000 k V实际电网的参数,并考虑线路走向等因素的影响,假设了一个特高压多电压等级电网,并建立了其GIC全节点模型。计算了两种感应地电场情况下500 k V电网、1 000 k V电网、500 k V和1 000 k V双电压等级电网的GIC,比较了三种情况电网的GIC计算结果。研究了不同电压等级电网GIC的相互作用及电网结构的影响。结果表明,1 000 k V电网GIC与500 k V电网GIC相互影响明显,在特高压电网GIC计算中,既不能在计算最高电压等级电网GIC时忽略次级高压电网的影响,也不能忽略对次级高压电网GIC的治理。展开更多
Full duplex communication highly improves spectrum efficiency of a wireless communication link.However, when it is applied to a cellular network, the capacity gain from this technology remains unknown. The reason is t...Full duplex communication highly improves spectrum efficiency of a wireless communication link.However, when it is applied to a cellular network, the capacity gain from this technology remains unknown. The reason is that full duplex communication changes the aggregate interference experienced by each communication link in cellular networks. In this paper, the capacity gain from full duplex communication is studied for cellular networks of 4G and beyond, where the same frequency channel is adopted in each cell. A two-layer Poisson point process(PPP) is adopted to model the network topology, and stochastic geometry is employed to derive the coverage probability and the average capacity of typical link in a cellular network. On the basis of these derived parameters, the capacity gain from full duplex communication is determined. Numerical results reveal that without mutual interference cancellation(MIC), the capacity gain is small under various power levels; with perfect MIC at base stations, the capacity gain can exceed 60%; with imperfect MIC at base stations, the capacity gain decreases quickly even with a slight drop of MIC performance.展开更多
基金国家自然科学基金项目(51177045)国家863高新技术发展计划项目(2012 A A121005)北京市教委中央在京高校共建项目(YB20101007901)资助
文摘电网地磁感应电流影响因素多、情况复杂,考虑各电压等级电网的参数特点,以往的GIC地磁感应电流计算集中在电网最高电压等级线路。交流特高压电网建设使我国电网增加了1 000 k V电压等级,综合考虑线路参数、变压器类型等GIC影响因素,准确计算包括500 k V超高压及1 000 k V特高压的多电压等级电网的GIC是重要研究课题。根据我国500 k V和1 000 k V实际电网的参数,并考虑线路走向等因素的影响,假设了一个特高压多电压等级电网,并建立了其GIC全节点模型。计算了两种感应地电场情况下500 k V电网、1 000 k V电网、500 k V和1 000 k V双电压等级电网的GIC,比较了三种情况电网的GIC计算结果。研究了不同电压等级电网GIC的相互作用及电网结构的影响。结果表明,1 000 k V电网GIC与500 k V电网GIC相互影响明显,在特高压电网GIC计算中,既不能在计算最高电压等级电网GIC时忽略次级高压电网的影响,也不能忽略对次级高压电网GIC的治理。
文摘Full duplex communication highly improves spectrum efficiency of a wireless communication link.However, when it is applied to a cellular network, the capacity gain from this technology remains unknown. The reason is that full duplex communication changes the aggregate interference experienced by each communication link in cellular networks. In this paper, the capacity gain from full duplex communication is studied for cellular networks of 4G and beyond, where the same frequency channel is adopted in each cell. A two-layer Poisson point process(PPP) is adopted to model the network topology, and stochastic geometry is employed to derive the coverage probability and the average capacity of typical link in a cellular network. On the basis of these derived parameters, the capacity gain from full duplex communication is determined. Numerical results reveal that without mutual interference cancellation(MIC), the capacity gain is small under various power levels; with perfect MIC at base stations, the capacity gain can exceed 60%; with imperfect MIC at base stations, the capacity gain decreases quickly even with a slight drop of MIC performance.