This study used the finite element method (FEM) to analyze the stress field and seepage field of a roller-compacted concrete (RCC) dam, with an upstream impervious layer constructed with different types of concret...This study used the finite element method (FEM) to analyze the stress field and seepage field of a roller-compacted concrete (RCC) dam, with an upstream impervious layer constructed with different types of concrete materials, including three-graded RCC, two-graded RCC, conven- tional vibrated concrete (CVC), and grout-enriched vibrated RCC (GEVR), corresponding to the design schemes S 1 through $4. It also evaluated the anti-seepage performance of the imperious layer in the four design schemes under the normal water level and flood-check level. Stress field analysis of a retaining section and discharge section shows that the maximum tensile stress occurs near the dam heel, the maximum compressive stress occurs near the dam toe, and the stress distributions in the four schemes can satisfy the stress control criteria. Seepage field analysis shows that the uplift pressure heads in schemes S3 and S4 descend rapidly in the anti-seepage region, and that the calculated results of daily seepage flow under the steady seepage condition in these two schemes are about 30%-50% lower than those in the other two schemes, demonstrating that CVC and GEVR show better anti-seepage performance. The results provide essential parameters such as the uplift pressure head and seelga^e flow for physical model tests and anti-seepage structure selection in RCC dams.展开更多
In this paper, regarding the actual conditions of a roller compacted concrete dam, three-dimensional finite element relocating mesh method is utilized to simulate and calculate the temperature field of the RCC dam dur...In this paper, regarding the actual conditions of a roller compacted concrete dam, three-dimensional finite element relocating mesh method is utilized to simulate and calculate the temperature field of the RCC dam during the construction stage and operating period. The calculation is well consistent with the actual construction process, the thin-layer pouring process the pouring temperature and all kinds of external loads involved being taken into account, By comparing and analyzing of the impact of the cold wave on the dam stress, important references are provided for the RCCD design and the temperature control during construction.展开更多
In this study, the limit state equation for tensile reliability analysis of the foundation surface of a gravity dam was established. The possible crack length was set as the action effect and allowable crack length wa...In this study, the limit state equation for tensile reliability analysis of the foundation surface of a gravity dam was established. The possible crack length was set as the action effect and allowable crack length was set as the resistance in the limit state. The nonlinear FEM was used to obtain the crack length of the foundation surface of the gravity dam, and the linear response surface method based on the orthogonal test design method was used to calculate the reliability, providing a reasonable and simple method for calculating the reliability of the serviceability limit state. The Longtan RCC gravity dam was chosen as an example. An orthogonal test, including eleven factors and two levels, was conducted, and the tensile reliability was calculated. The analysis shows that this method is reasonable.展开更多
基金supported by the National Basic Research Program of China(Grant No.2013CB035903)the National Natural Science Foundation of China(Grants No.51321065 and 51209159)
文摘This study used the finite element method (FEM) to analyze the stress field and seepage field of a roller-compacted concrete (RCC) dam, with an upstream impervious layer constructed with different types of concrete materials, including three-graded RCC, two-graded RCC, conven- tional vibrated concrete (CVC), and grout-enriched vibrated RCC (GEVR), corresponding to the design schemes S 1 through $4. It also evaluated the anti-seepage performance of the imperious layer in the four design schemes under the normal water level and flood-check level. Stress field analysis of a retaining section and discharge section shows that the maximum tensile stress occurs near the dam heel, the maximum compressive stress occurs near the dam toe, and the stress distributions in the four schemes can satisfy the stress control criteria. Seepage field analysis shows that the uplift pressure heads in schemes S3 and S4 descend rapidly in the anti-seepage region, and that the calculated results of daily seepage flow under the steady seepage condition in these two schemes are about 30%-50% lower than those in the other two schemes, demonstrating that CVC and GEVR show better anti-seepage performance. The results provide essential parameters such as the uplift pressure head and seelga^e flow for physical model tests and anti-seepage structure selection in RCC dams.
文摘In this paper, regarding the actual conditions of a roller compacted concrete dam, three-dimensional finite element relocating mesh method is utilized to simulate and calculate the temperature field of the RCC dam during the construction stage and operating period. The calculation is well consistent with the actual construction process, the thin-layer pouring process the pouring temperature and all kinds of external loads involved being taken into account, By comparing and analyzing of the impact of the cold wave on the dam stress, important references are provided for the RCCD design and the temperature control during construction.
文摘In this study, the limit state equation for tensile reliability analysis of the foundation surface of a gravity dam was established. The possible crack length was set as the action effect and allowable crack length was set as the resistance in the limit state. The nonlinear FEM was used to obtain the crack length of the foundation surface of the gravity dam, and the linear response surface method based on the orthogonal test design method was used to calculate the reliability, providing a reasonable and simple method for calculating the reliability of the serviceability limit state. The Longtan RCC gravity dam was chosen as an example. An orthogonal test, including eleven factors and two levels, was conducted, and the tensile reliability was calculated. The analysis shows that this method is reasonable.