The technology of drilling tests makes it possible to obtain the strength parameter of rock accurately in situ. In this paper, a new rock cutting analysis model that considers the influence of the rock crushing zone(R...The technology of drilling tests makes it possible to obtain the strength parameter of rock accurately in situ. In this paper, a new rock cutting analysis model that considers the influence of the rock crushing zone(RCZ) is built. The formula for an ultimate cutting force is established based on the limit equilibrium principle. The relationship between digital drilling parameters(DDP) and the c-φ parameter(DDP-cφ formula, where c refers to the cohesion and φ refers to the internal friction angle) is derived, and the response of drilling parameters and cutting ratio to the strength parameters is analyzed. The drillingbased measuring method for the c-φ parameter of rock is constructed. The laboratory verification test is then completed, and the difference in results between the drilling test and the compression test is less than 6%. On this basis, in-situ rock drilling tests in a traffic tunnel and a coal mine roadway are carried out, and the strength parameters of the surrounding rock are effectively tested. The average difference ratio of the results is less than 11%, which verifies the effectiveness of the proposed method for obtaining the strength parameters based on digital drilling. This study provides methodological support for field testing of rock strength parameters.展开更多
Air distribution of HVAC systems is the most popular type used in the building sector,having a relevant impact on indoor air quality and occupant wellness.Many types of research developed optimal solutions for the HVA...Air distribution of HVAC systems is the most popular type used in the building sector,having a relevant impact on indoor air quality and occupant wellness.Many types of research developed optimal solutions for the HVAC system’s design,focusing on specific components of the distribution system,on the airflow and geometry of ducts,on the size of ducts,on the shape and position of air diffusers.However,few works in literature proposed a globally experimental and simulation analysis of an air distribution system with a variable mass flaw rate.Along this line,the presented research investigates the potentialities of a new ceiling diffuser,installed in an exhibition room.This system provides a variable mass flow rate thanks to its configuration,providing adequate thermal comfort.A warm wall is chosen as the heating system.Several tests are carried out,six for cooling and two for heating with different volumetric air rates and supply air temperature of the diffusers.The combination of two methods,the measurement campaigns and the computational fluid dynamics(CFD)technique represent a suitable approach to examine the thermal indoor environment.In general,results show a strong capability of this diffuser to provide a uniform temperature and velocity field inside the room.Moreover,experimental and numerical data are significantly comparable with an average deviation of 1%for the velocity and lower 1%for the temperature,guaranteeing an optimal distribution of the understudy environmental parameters on the vertical and horizontal planes.展开更多
基金supported by the National Key Research and Development Program of China(No.2023YFC2907600)the National Natural Science Foundation of China(Nos.42077267,42277174 and 52074164)+2 种基金the Natural Science Foundation of Shandong Province,China(No.ZR2020JQ23)the Opening Project of State Key Laboratory of Explosion Science and Technology,Beijing Institute of Technology(No.KFJJ21-02Z)the Fundamental Research Funds for the Central Universities,China(No.2022JCCXSB03).
文摘The technology of drilling tests makes it possible to obtain the strength parameter of rock accurately in situ. In this paper, a new rock cutting analysis model that considers the influence of the rock crushing zone(RCZ) is built. The formula for an ultimate cutting force is established based on the limit equilibrium principle. The relationship between digital drilling parameters(DDP) and the c-φ parameter(DDP-cφ formula, where c refers to the cohesion and φ refers to the internal friction angle) is derived, and the response of drilling parameters and cutting ratio to the strength parameters is analyzed. The drillingbased measuring method for the c-φ parameter of rock is constructed. The laboratory verification test is then completed, and the difference in results between the drilling test and the compression test is less than 6%. On this basis, in-situ rock drilling tests in a traffic tunnel and a coal mine roadway are carried out, and the strength parameters of the surrounding rock are effectively tested. The average difference ratio of the results is less than 11%, which verifies the effectiveness of the proposed method for obtaining the strength parameters based on digital drilling. This study provides methodological support for field testing of rock strength parameters.
文摘Air distribution of HVAC systems is the most popular type used in the building sector,having a relevant impact on indoor air quality and occupant wellness.Many types of research developed optimal solutions for the HVAC system’s design,focusing on specific components of the distribution system,on the airflow and geometry of ducts,on the size of ducts,on the shape and position of air diffusers.However,few works in literature proposed a globally experimental and simulation analysis of an air distribution system with a variable mass flaw rate.Along this line,the presented research investigates the potentialities of a new ceiling diffuser,installed in an exhibition room.This system provides a variable mass flow rate thanks to its configuration,providing adequate thermal comfort.A warm wall is chosen as the heating system.Several tests are carried out,six for cooling and two for heating with different volumetric air rates and supply air temperature of the diffusers.The combination of two methods,the measurement campaigns and the computational fluid dynamics(CFD)technique represent a suitable approach to examine the thermal indoor environment.In general,results show a strong capability of this diffuser to provide a uniform temperature and velocity field inside the room.Moreover,experimental and numerical data are significantly comparable with an average deviation of 1%for the velocity and lower 1%for the temperature,guaranteeing an optimal distribution of the understudy environmental parameters on the vertical and horizontal planes.