In this paper, a full-order observer which can be fully decoupled from the unknown inputs as the conventional full-order observer does is designed by using auxiliary outputs, but the requirement of the matching condit...In this paper, a full-order observer which can be fully decoupled from the unknown inputs as the conventional full-order observer does is designed by using auxiliary outputs, but the requirement of the matching condition is removed. The procedure of calculating the parameter matrices of the full-order observer is also presented. Compared with the existing auxiliary outputs based sliding-mode observers, the designed observer has a simpler design procedure, which is systematic and does not involve solving linear matrix inequalities. The simulation results show that the proposed method is effective.展开更多
A parametric approach to robust fault detection in linear systems with unknown disturbances is presented. The residual is generated using full-order state observers (FSO). Based on an analytical solution to a type o...A parametric approach to robust fault detection in linear systems with unknown disturbances is presented. The residual is generated using full-order state observers (FSO). Based on an analytical solution to a type of Sylvester matrix equations, the parameterization of the observer gain matrix is given. In terms of the design degrees of freedom provided by the parametric observer design and a group of introduced parameter vectors, a sufficient and necessary condition for fullorder state observer design with disturbance decoupling is then established. By properly constraining the design parameters according to this proposed condition, the effect of the disturbance on the residual signal is also decoupled, and a simple algorithm is developed. The presented approach offers all the degrees of design freedom. Finally, a numerical example illustrates the effect of the proposed approach.展开更多
In this paper, fractional order PI(FOPI) control is developed for speed control of permanent magnet synchronous motor(PMSM). Designing the parameters for FOPI controller is a challenging task, especially for nonlinear...In this paper, fractional order PI(FOPI) control is developed for speed control of permanent magnet synchronous motor(PMSM). Designing the parameters for FOPI controller is a challenging task, especially for nonlinear systems like PMSM.All three PI controllers in the conventional vector controlled speed drive are replaced by FOPI controllers. Design of these FOPI controllers is based on the locally linearized model of PMSM around an operating point. This operating point changes with the load torque. The novelty of the work reported here is in use of Non Linear Disturbance Observer(NLDO) to estimate load torque to obtain this new operating point. All three FOPI controllers are then designed adaptively using this new operating point. The scheme is tested on simulation using MATLAB/SIMULINK and results are presented.展开更多
The research on high-performance vector control of permanent magnet synchronous motor(PMSM)drive system plays an extremely important role in electrical drive system.To further improve the speed control performance of ...The research on high-performance vector control of permanent magnet synchronous motor(PMSM)drive system plays an extremely important role in electrical drive system.To further improve the speed control performance of the system,a fast non-singular end sliding mode(FNTSM)surface function based on traditional NTSM control is developed.The theoretical analysis proves that the FNTSM surface function has a faster dynamic response and more finite-time convergence.In addition,for the self-vibration problem caused by high sliding mode switching gain,an FNTSM control method with anti-disturbance capability was designed based on the linear disturbance observer(DO),i.e.the FNTSMDO method was employed to devise the PMSM speed regulator.The comparative simulation and experiment results with traditional PI control and NTSM control methods indicate that the FNTSMDO method could improve the dynamic performance and anti-interference of the system.展开更多
In this paper, a kind of fire new nonlinear integrator and integral action is proposed. Consequently, a conventional Proportional Nonlinear Integral (P_NI) observer and two kinds of added-order P_NI observers are deve...In this paper, a kind of fire new nonlinear integrator and integral action is proposed. Consequently, a conventional Proportional Nonlinear Integral (P_NI) observer and two kinds of added-order P_NI observers are developed to deal with the uncertain nonlinear system. The conditions on the observer gains to ensure the estimated error to be ultimate boundness, which shrinks to zero as the states and control inputs converge to the equilibrium point, are provided. This means that if the observed system is asymptotically stable, the estimated error dynamics is asymptotically stable, too. Moreover, the highlight point of this paper is that the design of nonlinear integral observer is achieved by linear system theory. Simulation results showed that under the normal and perturbed cases, the pure added-order P_NI observer can effectively deal with the uncertain nonlinearities on both the system dynamics and measured outputs.展开更多
This paper studies the problem of diagnosis strategy for a doubly fed induction motor (DFIM) sensor faults. This strategy is based on unknown input proportional integral (PI) multiobserver. Thecontribution of this pap...This paper studies the problem of diagnosis strategy for a doubly fed induction motor (DFIM) sensor faults. This strategy is based on unknown input proportional integral (PI) multiobserver. Thecontribution of this paper is on one hand the creation of a new DFIM model based on multi-model approach and, on the other hand, the synthesis of an adaptive PI multi-observer. The DFIM Volt per Hertz drive system behaves as a nonlinear complex system. It consists of a DFIM powered through a controlled PWM Voltage Source Inverter (VSI). The need of a sensorless drive requires soft sensors such as estimators or observers. In particular, an adaptive Proportional-Integral multi-observer is synthesized in order to estimate the DFIM’s outputs which are affected by different faults and to generate the different residual signals symptoms of sensor fault occurrence. The convergence of the estimation error is guaranteed by using the Lyapunov’s based theory. The proposed diagnosis approach is experimentally validated on a 1 kW Induction motor. Obtained simulation results confirm that the adaptive PI multiobserver consent to accomplish the detection, isolation and fault identification tasks with high dynamic performances.展开更多
基金Supported by the National Natural Science Foundation of China(No.61203299)
文摘In this paper, a full-order observer which can be fully decoupled from the unknown inputs as the conventional full-order observer does is designed by using auxiliary outputs, but the requirement of the matching condition is removed. The procedure of calculating the parameter matrices of the full-order observer is also presented. Compared with the existing auxiliary outputs based sliding-mode observers, the designed observer has a simpler design procedure, which is systematic and does not involve solving linear matrix inequalities. The simulation results show that the proposed method is effective.
基金This work was supported by the National Natural Science Foundation of China (No. 60374024)the Program for Changjiang Scholars andInnovative Research Team in University.
文摘A parametric approach to robust fault detection in linear systems with unknown disturbances is presented. The residual is generated using full-order state observers (FSO). Based on an analytical solution to a type of Sylvester matrix equations, the parameterization of the observer gain matrix is given. In terms of the design degrees of freedom provided by the parametric observer design and a group of introduced parameter vectors, a sufficient and necessary condition for fullorder state observer design with disturbance decoupling is then established. By properly constraining the design parameters according to this proposed condition, the effect of the disturbance on the residual signal is also decoupled, and a simple algorithm is developed. The presented approach offers all the degrees of design freedom. Finally, a numerical example illustrates the effect of the proposed approach.
文摘In this paper, fractional order PI(FOPI) control is developed for speed control of permanent magnet synchronous motor(PMSM). Designing the parameters for FOPI controller is a challenging task, especially for nonlinear systems like PMSM.All three PI controllers in the conventional vector controlled speed drive are replaced by FOPI controllers. Design of these FOPI controllers is based on the locally linearized model of PMSM around an operating point. This operating point changes with the load torque. The novelty of the work reported here is in use of Non Linear Disturbance Observer(NLDO) to estimate load torque to obtain this new operating point. All three FOPI controllers are then designed adaptively using this new operating point. The scheme is tested on simulation using MATLAB/SIMULINK and results are presented.
基金supported in part by the National Natural Science Foundation of China under Grant 51507188Doctoral Research Startup Foundation of Hubei University of Technology under Grant XJ2021000302。
文摘The research on high-performance vector control of permanent magnet synchronous motor(PMSM)drive system plays an extremely important role in electrical drive system.To further improve the speed control performance of the system,a fast non-singular end sliding mode(FNTSM)surface function based on traditional NTSM control is developed.The theoretical analysis proves that the FNTSM surface function has a faster dynamic response and more finite-time convergence.In addition,for the self-vibration problem caused by high sliding mode switching gain,an FNTSM control method with anti-disturbance capability was designed based on the linear disturbance observer(DO),i.e.the FNTSMDO method was employed to devise the PMSM speed regulator.The comparative simulation and experiment results with traditional PI control and NTSM control methods indicate that the FNTSMDO method could improve the dynamic performance and anti-interference of the system.
文摘In this paper, a kind of fire new nonlinear integrator and integral action is proposed. Consequently, a conventional Proportional Nonlinear Integral (P_NI) observer and two kinds of added-order P_NI observers are developed to deal with the uncertain nonlinear system. The conditions on the observer gains to ensure the estimated error to be ultimate boundness, which shrinks to zero as the states and control inputs converge to the equilibrium point, are provided. This means that if the observed system is asymptotically stable, the estimated error dynamics is asymptotically stable, too. Moreover, the highlight point of this paper is that the design of nonlinear integral observer is achieved by linear system theory. Simulation results showed that under the normal and perturbed cases, the pure added-order P_NI observer can effectively deal with the uncertain nonlinearities on both the system dynamics and measured outputs.
文摘This paper studies the problem of diagnosis strategy for a doubly fed induction motor (DFIM) sensor faults. This strategy is based on unknown input proportional integral (PI) multiobserver. Thecontribution of this paper is on one hand the creation of a new DFIM model based on multi-model approach and, on the other hand, the synthesis of an adaptive PI multi-observer. The DFIM Volt per Hertz drive system behaves as a nonlinear complex system. It consists of a DFIM powered through a controlled PWM Voltage Source Inverter (VSI). The need of a sensorless drive requires soft sensors such as estimators or observers. In particular, an adaptive Proportional-Integral multi-observer is synthesized in order to estimate the DFIM’s outputs which are affected by different faults and to generate the different residual signals symptoms of sensor fault occurrence. The convergence of the estimation error is guaranteed by using the Lyapunov’s based theory. The proposed diagnosis approach is experimentally validated on a 1 kW Induction motor. Obtained simulation results confirm that the adaptive PI multiobserver consent to accomplish the detection, isolation and fault identification tasks with high dynamic performances.