The electronic structures of Ti_2NbSb with Hg_2CuTi structure and TiZrNbSb with LiMgPdSn structure are investigated using first-principles calculations.The results indicate that Ti_2NbSb is a fully compensated ferrima...The electronic structures of Ti_2NbSb with Hg_2CuTi structure and TiZrNbSb with LiMgPdSn structure are investigated using first-principles calculations.The results indicate that Ti_2NbSb is a fully compensated ferrimagnetic spin-gapless semiconductor with an energy gap of 0.13 e V,and TiZrNbSb is a half-metallic fully compensated ferrimagnet with a half-metallic gap of 0.17 e V.For Ti_2NbSb,the total energy of the Hg_2CuTi structure is0.62 e V/f.u.higher than that of the L2_(1) structure,which is the ground state,and for TiZrNbSb,the total energy of the structure considered in this work is only 0.15 e V/f.u.larger than that of the ground state.Thus both of them may be good candidates for spintronic applications.展开更多
The ecological protection of the inter-provincial river basin of Xin’anjiang River takes the ecological compensation mechanism as the starting point and achieves good results.The success of the mechanism is best refl...The ecological protection of the inter-provincial river basin of Xin’anjiang River takes the ecological compensation mechanism as the starting point and achieves good results.The success of the mechanism is best reflected in its innovation of public policy supply,which is not only a vivid practice of Xi Jinping’s ecological civilization thought in the new era,but also establishes a model for absorption,transformation and export of policy supply.The effective supply of public policies on ecological environment is the realistic choice for the construction of ecological civilization in the new era.展开更多
This paper reports a new project - the poloidal field (PF) grid power supply system to replace the ac flywheel generator power supply system on the basis of the present running parameters of the HT-7 poloidal field ...This paper reports a new project - the poloidal field (PF) grid power supply system to replace the ac flywheel generator power supply system on the basis of the present running parameters of the HT-7 poloidal field and the short-circuit capacity of our transformer substation. The designed parameters of the PF grid power supply system have been verified to meet the requirements of the heating field (HF) and the vertical field (VF). In the meantime, in order to reduce the disturbance to the local power grid, the device of reactive power and harmonic current compensation has been added. Experimental results have confirmed the feasibility of the PF grid power supply system. Compared with the ac flywheel generator, the PF grid power supply system has the advantages of lower noise, precise control, convenient maintenance, simple operation and cost savings.展开更多
In this paper, a strategy for the reactive power compensation and harmonic suppression of the power supply system in HT-7U superconductive Tokamak is proposed. The optimized approach is given in the parameters design...In this paper, a strategy for the reactive power compensation and harmonic suppression of the power supply system in HT-7U superconductive Tokamak is proposed. The optimized approach is given in the parameters design for passive filter. Also a controlling method with fast response time and good accuracy is put forward for the compensator, which is more suitable for the dynamic load.展开更多
In order to solve negative phase sequence problem of V connection transformer in the high speed and heavy haul electrical railway of China, the hybrid compensative co-phase traction power supply system which based on ...In order to solve negative phase sequence problem of V connection transformer in the high speed and heavy haul electrical railway of China, the hybrid compensative co-phase traction power supply system which based on passive and active compensation is proposed. Firstly, There construction and capacity distribution are analyzed, and the compensation current of active equipment is gave;Second, the feature of the hybrid compensative schemes are discussed. In the end, the related simulation results have confirmed the effectiveness of the compensation schemes in this paper.展开更多
基金Supported by the National Natural Science Foundation of China under Grant No 51301119the Natural Science Foundation for Young Scientists of Shanxi Province under Grant No 2013021010-1the Scientific and Technological Innovation Programs of Higher Education Institutions of Shanxi Province under Grant No 201802023
文摘The electronic structures of Ti_2NbSb with Hg_2CuTi structure and TiZrNbSb with LiMgPdSn structure are investigated using first-principles calculations.The results indicate that Ti_2NbSb is a fully compensated ferrimagnetic spin-gapless semiconductor with an energy gap of 0.13 e V,and TiZrNbSb is a half-metallic fully compensated ferrimagnet with a half-metallic gap of 0.17 e V.For Ti_2NbSb,the total energy of the Hg_2CuTi structure is0.62 e V/f.u.higher than that of the L2_(1) structure,which is the ground state,and for TiZrNbSb,the total energy of the structure considered in this work is only 0.15 e V/f.u.larger than that of the ground state.Thus both of them may be good candidates for spintronic applications.
文摘The ecological protection of the inter-provincial river basin of Xin’anjiang River takes the ecological compensation mechanism as the starting point and achieves good results.The success of the mechanism is best reflected in its innovation of public policy supply,which is not only a vivid practice of Xi Jinping’s ecological civilization thought in the new era,but also establishes a model for absorption,transformation and export of policy supply.The effective supply of public policies on ecological environment is the realistic choice for the construction of ecological civilization in the new era.
基金The project supported by the Meg-science Engineering Project of the Chinese Academy of Sciences
文摘This paper reports a new project - the poloidal field (PF) grid power supply system to replace the ac flywheel generator power supply system on the basis of the present running parameters of the HT-7 poloidal field and the short-circuit capacity of our transformer substation. The designed parameters of the PF grid power supply system have been verified to meet the requirements of the heating field (HF) and the vertical field (VF). In the meantime, in order to reduce the disturbance to the local power grid, the device of reactive power and harmonic current compensation has been added. Experimental results have confirmed the feasibility of the PF grid power supply system. Compared with the ac flywheel generator, the PF grid power supply system has the advantages of lower noise, precise control, convenient maintenance, simple operation and cost savings.
文摘In this paper, a strategy for the reactive power compensation and harmonic suppression of the power supply system in HT-7U superconductive Tokamak is proposed. The optimized approach is given in the parameters design for passive filter. Also a controlling method with fast response time and good accuracy is put forward for the compensator, which is more suitable for the dynamic load.
文摘In order to solve negative phase sequence problem of V connection transformer in the high speed and heavy haul electrical railway of China, the hybrid compensative co-phase traction power supply system which based on passive and active compensation is proposed. Firstly, There construction and capacity distribution are analyzed, and the compensation current of active equipment is gave;Second, the feature of the hybrid compensative schemes are discussed. In the end, the related simulation results have confirmed the effectiveness of the compensation schemes in this paper.