In view of the current sensors failure in electric pitch system,a variable universe fuzzy fault tolerant control method of electric pitch control system based on single current detection is proposed.When there is sing...In view of the current sensors failure in electric pitch system,a variable universe fuzzy fault tolerant control method of electric pitch control system based on single current detection is proposed.When there is single or two-current sensor fault occurs,based on the proposed method the missing current information can be reconstructed by using direct current(DC)bus current sensor and the three-phase current can be updated in time within any two adjacent sampling periods,so as to ensure stability of the closed-loop system.And then the switchover and fault tolerant control of fault current sensor would be accomplished by fault diagnosis method based on adaptive threshold judgment.For the reconstructed signal error caused by the modulation method and the main control target of electric pitch system,a variable universe fuzzy control method is used in the speed loop,which can improve the anti-disturbance ability to load variation,and the robustness of fault tolerance system.The results show that the fault tolerant control method makes the variable pitch control system still has ideal control characteristics in case of sensor failure although part of the system performance is lost,thus the correctness of the proposed method is verified.展开更多
A kind of stable adaptive fuzzy control of nonlinear system is implemented using variable universe method. First of all, the basic structure of variable universe adaptive fuzzy controllers is briefly introduced. Then ...A kind of stable adaptive fuzzy control of nonlinear system is implemented using variable universe method. First of all, the basic structure of variable universe adaptive fuzzy controllers is briefly introduced. Then the contraction-expansion factor that is a key tool of variable universe method is defined by means of integral regulation idea, and a kind of adaptive fuzzy controllers is designed by using such a contraction-expansion factor. The simulation on first order nonlinear system is done. Secondly, it is proved that the variable universe adaptive fuzzy control is asymptotically stable by use of Lyapunov theory. The simulation on the second order nonlinear system shows that its simulation effect is also quite good. Finally a useful tool, called symbolic factor, is proposed, which may be of universal significance. It can greatly reduce the settling time and enhance the robustness of the system.展开更多
This paper studies the longitudinal predictive re-entry guidance law based on the variable universe fuzzy- PI composite control to overcome the inaccuracy of the reference trajectory re-entry guidance for reentry vehi...This paper studies the longitudinal predictive re-entry guidance law based on the variable universe fuzzy- PI composite control to overcome the inaccuracy of the reference trajectory re-entry guidance for reentry vehicles. The variable universe fuzzy controller is used to obtain a satisfactory dynamic response when the downrange error is large, and the PI controller is utilized to eliminate the steady state error when the downrange error is small. Simulation results show that the proposed guidance law is very robust to the initial errors and can achieve better accuracy, and is also able to handle the effect of the stochastic errors in re-entry processes.展开更多
To address complex work conditions incredibly challenging to the stability of power line inspection robots,we design a walking mechanism and propose a variable universe fuzzy control(VUFC)method based on multi‐work c...To address complex work conditions incredibly challenging to the stability of power line inspection robots,we design a walking mechanism and propose a variable universe fuzzy control(VUFC)method based on multi‐work conditions for flying‐walking power line inspection robots(FPLIRs).The contributions of this paper are as follows:(1)A flexible pressing component is designed to improve the adaptability of the FPLIR to the ground line slope.(2)The influence of multi‐work conditions on the FPLIR's walking stability is quantified using three condition parameters(i.e.,slope,slipping degree and swing angle),and their measurement methods are proposed.(3)The VUFC method based on the condition parameters is proposed to improve the walking stability of the FPLIR.Finally,the effect of the VUFC method on walking stability of the FPLIR is teste.The experimental results show that the maximum climbing angle of the FPLIR reaches 29.1°.Compared with the constant pressing force of 30 N,the average value of slipping degree is 0.93°,increasing by 35%.The maximum and average values of robot's swing angle are reduced by 46%and 54%,respectively.By comparing with fuzzy control,the VUFC can provide a more reasonable pressing force while maintaining the walking stability of the FPLIR.The proposed walking mechanism and the VUFC method significantly improve the stability of the FPLIR,providing a reference for structural designs and stability controls of inspection robots.展开更多
基金Natural Science Foundation of Gansu Province(Joint)Project(No.213244)Natural Science Foundation of Gansu Province(No.145RJZA136)Youth Science Foundation of Lanzhou Jiaotong University(No.2013040)
文摘In view of the current sensors failure in electric pitch system,a variable universe fuzzy fault tolerant control method of electric pitch control system based on single current detection is proposed.When there is single or two-current sensor fault occurs,based on the proposed method the missing current information can be reconstructed by using direct current(DC)bus current sensor and the three-phase current can be updated in time within any two adjacent sampling periods,so as to ensure stability of the closed-loop system.And then the switchover and fault tolerant control of fault current sensor would be accomplished by fault diagnosis method based on adaptive threshold judgment.For the reconstructed signal error caused by the modulation method and the main control target of electric pitch system,a variable universe fuzzy control method is used in the speed loop,which can improve the anti-disturbance ability to load variation,and the robustness of fault tolerance system.The results show that the fault tolerant control method makes the variable pitch control system still has ideal control characteristics in case of sensor failure although part of the system performance is lost,thus the correctness of the proposed method is verified.
基金This work was supported by the National Natural Science Foundation of China (Grant Nos. 69974006 and 60174013).
文摘A kind of stable adaptive fuzzy control of nonlinear system is implemented using variable universe method. First of all, the basic structure of variable universe adaptive fuzzy controllers is briefly introduced. Then the contraction-expansion factor that is a key tool of variable universe method is defined by means of integral regulation idea, and a kind of adaptive fuzzy controllers is designed by using such a contraction-expansion factor. The simulation on first order nonlinear system is done. Secondly, it is proved that the variable universe adaptive fuzzy control is asymptotically stable by use of Lyapunov theory. The simulation on the second order nonlinear system shows that its simulation effect is also quite good. Finally a useful tool, called symbolic factor, is proposed, which may be of universal significance. It can greatly reduce the settling time and enhance the robustness of the system.
文摘This paper studies the longitudinal predictive re-entry guidance law based on the variable universe fuzzy- PI composite control to overcome the inaccuracy of the reference trajectory re-entry guidance for reentry vehicles. The variable universe fuzzy controller is used to obtain a satisfactory dynamic response when the downrange error is large, and the PI controller is utilized to eliminate the steady state error when the downrange error is small. Simulation results show that the proposed guidance law is very robust to the initial errors and can achieve better accuracy, and is also able to handle the effect of the stochastic errors in re-entry processes.
基金National Natural Science Foundation of China,Grant/Award Numbers:62063030,62163032Financial Science and Technology Program of the XPCC,Grant/Award Numbers:2021DB003,2022CB002‐07,2022CB011High‐level Talent Project of Shihezi University,Grant/Award Numbers:RCZK2018C31,RCZK2018C32。
文摘To address complex work conditions incredibly challenging to the stability of power line inspection robots,we design a walking mechanism and propose a variable universe fuzzy control(VUFC)method based on multi‐work conditions for flying‐walking power line inspection robots(FPLIRs).The contributions of this paper are as follows:(1)A flexible pressing component is designed to improve the adaptability of the FPLIR to the ground line slope.(2)The influence of multi‐work conditions on the FPLIR's walking stability is quantified using three condition parameters(i.e.,slope,slipping degree and swing angle),and their measurement methods are proposed.(3)The VUFC method based on the condition parameters is proposed to improve the walking stability of the FPLIR.Finally,the effect of the VUFC method on walking stability of the FPLIR is teste.The experimental results show that the maximum climbing angle of the FPLIR reaches 29.1°.Compared with the constant pressing force of 30 N,the average value of slipping degree is 0.93°,increasing by 35%.The maximum and average values of robot's swing angle are reduced by 46%and 54%,respectively.By comparing with fuzzy control,the VUFC can provide a more reasonable pressing force while maintaining the walking stability of the FPLIR.The proposed walking mechanism and the VUFC method significantly improve the stability of the FPLIR,providing a reference for structural designs and stability controls of inspection robots.