A direct numerical simulation(DNS) method is used to calculate the partitioned convection system with Ra number ranging from 10^7 to 2×10^9.Using the boundary layer thickness to normalize the height of gaps d, we...A direct numerical simulation(DNS) method is used to calculate the partitioned convection system with Ra number ranging from 10^7 to 2×10^9.Using the boundary layer thickness to normalize the height of gaps d, we find a strong consistency between the variation of the TD number(the average value of the temperature in each heat transfer channel is averaged after taking the absolute values) with the change of the height of gaps and the variation of the TD number with the change of Ra number in partitioned convection.For a given thickness of partition, heights of gaps are approximately equal to 0.5 or 1 time of the thermal boundary layer thickness λθ at different Ra numbers.TD number representing temperature characteristics is almost the constant value, which means that TD number is a function of d/λθ only.Analysis of local temperature field of area in gaps shows that the temperature distribution in the gaps are basically the same when d/λθ is certain.The heat transfer Nu number of the system at d/λθ≈ 0.5 is larger than that of d/λθ≈ 1, both of them have the same scaling law with Ra number and Nu^Ra^0.25.展开更多
Infectious disease departments in hospitals require pressure gradient to create unidirectional airflow to prevent the spread of contaminants,typically by creating active air infiltration through the difference between...Infectious disease departments in hospitals require pressure gradient to create unidirectional airflow to prevent the spread of contaminants,typically by creating active air infiltration through the difference between supply and exhaust air volumes.The door gap is the channel of air flow between rooms,so its height has an important influence on the pressure difference and infiltration air volume of the room.There is still a lack of research on setting reasonable ventilation strategies according to the different heights of door gaps at different positions in the building.In this study,model of a set of isolation wards was established and analyzed using the multi-zone simulation software CONTAM,and the ventilation strategies with different heights of door gaps were applied to the actual infection diseases department.The results show that in a building with ventilation system divided by functional area,the difference in the height of the door gaps requires different active infiltration air volumes.Pressure fluctuations in the medical and patient corridors are greater than in other rooms.The significance of this study is to understand the active infiltration of air to guide the design and operation of ventilation systems in infectious disease hospitals or building remodeled to isolate close contacts of COVID-19 patients.It is also instructive for the design of pressure gradients in clean workshops,biological laboratories,and other similar buildings.展开更多
We demonstrate that the insertion of a graphene tunnel barrier between Heusler alloy Co_2MnSi and the germanium(Ge) channel modulates the Schottky barrier height and the resistance–area product of the spin diode. W...We demonstrate that the insertion of a graphene tunnel barrier between Heusler alloy Co_2MnSi and the germanium(Ge) channel modulates the Schottky barrier height and the resistance–area product of the spin diode. We confirm that the Fermi level is depinned and a reduction in the electron Schottky barrier height(SBH) occurs following the insertion of the graphene layer between Co_2MnSi and Ge. The electron SBH is modulated in the 0.34 eV–0.61 eV range. Furthermore,the transport mechanism changes from rectifying to symmetric tunneling following the insertion. This behavior provides a pathway for highly efficient spin injection from a Heusler alloy into a Ge channel with high electron and hole mobility.展开更多
基金Project supported by the National Natural Science Foundation of China(Grant Nos.11772362 and 11452002)the Special Scientific Research Fund for Super Computing in the Joint Fund of the National Natural Science Foundation of China and the People’s Government of Guangdong Province,China(Phase Ⅱ,nsfc2015_570)
文摘A direct numerical simulation(DNS) method is used to calculate the partitioned convection system with Ra number ranging from 10^7 to 2×10^9.Using the boundary layer thickness to normalize the height of gaps d, we find a strong consistency between the variation of the TD number(the average value of the temperature in each heat transfer channel is averaged after taking the absolute values) with the change of the height of gaps and the variation of the TD number with the change of Ra number in partitioned convection.For a given thickness of partition, heights of gaps are approximately equal to 0.5 or 1 time of the thermal boundary layer thickness λθ at different Ra numbers.TD number representing temperature characteristics is almost the constant value, which means that TD number is a function of d/λθ only.Analysis of local temperature field of area in gaps shows that the temperature distribution in the gaps are basically the same when d/λθ is certain.The heat transfer Nu number of the system at d/λθ≈ 0.5 is larger than that of d/λθ≈ 1, both of them have the same scaling law with Ra number and Nu^Ra^0.25.
文摘Infectious disease departments in hospitals require pressure gradient to create unidirectional airflow to prevent the spread of contaminants,typically by creating active air infiltration through the difference between supply and exhaust air volumes.The door gap is the channel of air flow between rooms,so its height has an important influence on the pressure difference and infiltration air volume of the room.There is still a lack of research on setting reasonable ventilation strategies according to the different heights of door gaps at different positions in the building.In this study,model of a set of isolation wards was established and analyzed using the multi-zone simulation software CONTAM,and the ventilation strategies with different heights of door gaps were applied to the actual infection diseases department.The results show that in a building with ventilation system divided by functional area,the difference in the height of the door gaps requires different active infiltration air volumes.Pressure fluctuations in the medical and patient corridors are greater than in other rooms.The significance of this study is to understand the active infiltration of air to guide the design and operation of ventilation systems in infectious disease hospitals or building remodeled to isolate close contacts of COVID-19 patients.It is also instructive for the design of pressure gradients in clean workshops,biological laboratories,and other similar buildings.
基金Project supported by the National Natural Science Foundation of China(Grant No.61504107)the Fundamental Research Funds for the Central Universities,China(Grant Nos.3102014JCQ01059 and 3102015ZY043)
文摘We demonstrate that the insertion of a graphene tunnel barrier between Heusler alloy Co_2MnSi and the germanium(Ge) channel modulates the Schottky barrier height and the resistance–area product of the spin diode. We confirm that the Fermi level is depinned and a reduction in the electron Schottky barrier height(SBH) occurs following the insertion of the graphene layer between Co_2MnSi and Ge. The electron SBH is modulated in the 0.34 eV–0.61 eV range. Furthermore,the transport mechanism changes from rectifying to symmetric tunneling following the insertion. This behavior provides a pathway for highly efficient spin injection from a Heusler alloy into a Ge channel with high electron and hole mobility.