A method for the assay of R ( ) and S (+) mexiletine in rat liver microsomal incubates was developed. The method involved extraction of mexiletine from the microsomal incubates, and formation of mexiletine diast...A method for the assay of R ( ) and S (+) mexiletine in rat liver microsomal incubates was developed. The method involved extraction of mexiletine from the microsomal incubates, and formation of mexiletine diastereomeric derivatives with a chiral reagent S ( ) N trifluoroacetyl prolyl chloride. Separation and quantitation of the diastereomeric mexiletine derivatives were carried out by a capillary gas chromatographic system with flame ionization detection. The assay was linear from 5 to 500 μg/ml for each enantiomer. The average recoveries of analytical method were 93 31±5 59% and 93 10±5 11% for R ( ) and S (+) mexiletine, respectively. The limits of detection and quantitation for the method were 1 0 μg/ml and 5 0 μg/ml for the R ( ) and S (+) mexiletine isomers, respectively. The reproducibility in the assay was better than 16.5% (RSD). The method has been applied to the metabolism study of R ( ) and S (+) mexiletine in rat liver microsomal incubates.展开更多
A new compound of mono 6 (1' benzo aza 15 crown 5) 2,3,6 permethyl β cyclodextrin (BA 15C5 PM CD) was synthesized. The structure was determined to be coincide with our anticipation by spectroscopy....A new compound of mono 6 (1' benzo aza 15 crown 5) 2,3,6 permethyl β cyclodextrin (BA 15C5 PM CD) was synthesized. The structure was determined to be coincide with our anticipation by spectroscopy. As a stationary phase for capillary gas chromatography, excellent separation for enantiomers and positional isomers was achieved.展开更多
Background: Impurities are not expected in the final pharmaceutical products. All impurities should be regulated in both drug substances and drug products in accordance with pharmacopeias and ICH guidelines. Three dif...Background: Impurities are not expected in the final pharmaceutical products. All impurities should be regulated in both drug substances and drug products in accordance with pharmacopeias and ICH guidelines. Three different types of impurities are generally available in the pharmaceutical’s product specification: organic impurities, inorganic impurities, and residual solvents. Residual solvents are organic volatile chemicals used or generated during the manufacturing of drug substances or drug products. Purpose: The aim of this study is to develop a cost-effective gas chromatographic method for the identification and quantification of some commonly used solvents—methanol, acetone, isopropyl alcohol (IPA), methylene chloride, ethyl acetate, tetrahydrofuran (THF), benzene, toluene, and pyridine—in pharmaceutical product manufacturing. This method will be able to identify and quantify the multiple solvents within a single gas chromatographic procedure. Method: A gas chromatography (GC) equipped with a headspace sampler and a flame ionization detector, and a column DB 624, 30-meter-long × 0.32-millimeter internal diameter, 1,8 μm-thick, Brand-Agilent was used to develop this method. The initial GC oven temperature was 40°C and held for 5 minutes. It was then increase to 80˚C at a rate of 2˚C per minute, followed by a further increase to 225˚C at a rate of 30˚C per minute, with a final hold at 225˚C for 10 minutes. Nitrogen was used as a carrier gas at a flow rate of 1.20 mL per minute. Dimethyl sulfoxide (DMSO) was selected as sample solvent. Results: The developed method is precise and specific. The percent RSD for the areas of six replicate injections of this gas chromatographic method was within 10.0 and the recovery result found within 80.0% to 120.0%.展开更多
The combination of pyrolysis high resolution gas chromatography and pat- tern recognition techniques is a powerful tool for the classification of traditional Chinese drug.A study has been completed on 55 Beimu samples...The combination of pyrolysis high resolution gas chromatography and pat- tern recognition techniques is a powerful tool for the classification of traditional Chinese drug.A study has been completed on 55 Beimu samples of five different geographic origins: Eastern China.Central China.South-western China,North-western China and North-eastern China.Principal component analysis and SIMCA are applied to effectively classifying the samples according to the origin of the plants.The chemical information contained in the high resolution gas chromatographic data is sufficient to characterize the geographic origin of sam- pies.展开更多
A method for the determination of dichlofluanid residue by Capillary Collumns Gas Chromatography was established in this study.Samples were extracted with acetone and subjected to through liquid-liquid extraction with...A method for the determination of dichlofluanid residue by Capillary Collumns Gas Chromatography was established in this study.Samples were extracted with acetone and subjected to through liquid-liquid extraction with N-hexane,and then they were cleanup with column that filled with florisil,subsequently separated by Capillary Column Gas Chromatography,and the electron capture detector (ECD) was used for detection.The detection limit of this method was 0.005 mg/kg (S/N=3),and this method was rapid,sensitive and accurate,and was applied in the determination of dichlofluanid residue in soybean.展开更多
A new capillary gas chromatography stationary phase, monokis (2,6 di O benzyl 3 O propyl (3’)) hexakis(2,6 di O benzyl 3 O methyl) β CD bonded polysiloxane, was synthesized. It ex...A new capillary gas chromatography stationary phase, monokis (2,6 di O benzyl 3 O propyl (3’)) hexakis(2,6 di O benzyl 3 O methyl) β CD bonded polysiloxane, was synthesized. It exhibited separation abilities to disubstituted benzene isomers and some chiral solutes. It was also found that the polarity of CD derivatives can be lowered both by chemically bonding it to polysiloxane and by diluting it in polysiloxane. The separation abilities of the polysiloxane anchored CDs (SP CD) are higher than that of the unbonded CDs (S CD) and the diluted S CD at lower column temperature. Hydrosilylation reaction is one of the best methods to lower the operating temperature of CDs.展开更多
A new method for simultaneous determination of four phthalate esters ( PAEs) in commercial fat-containing foods was developed by the combination of a packed nanofibers column based on solid-phase extraction with gas...A new method for simultaneous determination of four phthalate esters ( PAEs) in commercial fat-containing foods was developed by the combination of a packed nanofibers column based on solid-phase extraction with gas chromatography-flame ionization detector ( GC-FID ). Conditions for obtaining optimum extraction efficiency such as extraction solvents, morphologies of adsorbent, ion strength and pH were investigated and optimized in detail. Under the optimized conditions, the limits of detection (LODs) found for dibutyl phthalate (DBP) , butyl benzyl phthalate (BBP), diethyl hexyl phthalate (DEHP) and di-n-octyl phthalate (DNOP) were 50, 25, 50 and 25 ng/g, respectively. Good linearity of four PAEs was achieved in the range of 50 to 4 000 ng/g. The proposed method was applied for analyzing different kinds of fat-containing samples. PAEs in commercial fat-containing samples can be highly extracted by a packed solid-phase extraction column of 5 mg polystyrene ( PS) nanofibers. The satisfactory average recoveries were obtained in the range of 96. 7% to 102. 3% , and the relative standard deviations (RSDs) below 5% were achieved. The proposed method reduces the organic solvent consumption, the complex and tedious procedures for sample pretreatment, and achieves high sensitivity and reproducibility for the investigated PAEs.展开更多
The composition and sequence distribution of monomeric units in polyester polyether multiblock copolymer were studied by pyrolysis? gas chromatography (PGC) and pyrolysis gas chromatography/mass spectrometry (PGC/M...The composition and sequence distribution of monomeric units in polyester polyether multiblock copolymer were studied by pyrolysis? gas chromatography (PGC) and pyrolysis gas chromatography/mass spectrometry (PGC/MS). PGC was applied to study the F t curve of the multiblock copolymer and PGC/MS was used to separate and identify the pyrolyzates. DTA experiment was used to study the decomposition temperature. The results show that the beginning point of elastomer’s decomposition was about 300?℃ and the decomposition temperature of most of the sample was 550?℃. Many pyrolyzates were produced because of the breaking of weak bonds in the sample. The possible microstructure was verified and the pyrolysis pathway of the copolymer was investigated.展开更多
Applications of pyrolysis-gas chromatography and pyrolysis capillary gas chromatography in explosive and propellant analysis are reviewed, including the identification of explosives and propel- lants, the investigatio...Applications of pyrolysis-gas chromatography and pyrolysis capillary gas chromatography in explosive and propellant analysis are reviewed, including the identification of explosives and propel- lants, the investigation of the thermal decomposition of nitrocellulose (NC), cyclotetramethylene tetranitramine (HMX)and cyclotrimethylene trinitramine (RDX), and the study of the wear- reducing mechanism of polyurethane additive in propellant gain.展开更多
The cross-linking of crown ether-SE-54 in fused-silica capillary columns were initiated by dicumyl peroxide(DCUP),azo-bis-isobutyronitrile (AIBN)and ozone(O_3).Parameters of evaluation such as polarity,selectivity, ph...The cross-linking of crown ether-SE-54 in fused-silica capillary columns were initiated by dicumyl peroxide(DCUP),azo-bis-isobutyronitrile (AIBN)and ozone(O_3).Parameters of evaluation such as polarity,selectivity, phase transition temperature and thermal stability were studied and compared with those of poly(crown ether)stationary phase.展开更多
The variation among Chinese genotypes of Brassica napus L. for seed tocopherols content and their analysis using gas chromatography has not been comprehensively reported till to date. In the present study, the tocophe...The variation among Chinese genotypes of Brassica napus L. for seed tocopherols content and their analysis using gas chromatography has not been comprehensively reported till to date. In the present study, the tocopherol contents of four Chinese genotypes of Brassica napus L., namely, Gaoyou 605, Zhejiang 619, Zheshuang 758, and Zheshuang 72, were evaluated using three modified sample preparation protocols (P1, P2, and P3) for tocopherol extraction. These methods were distinguished as follows. Protocol one (P1) included the evaporation of solvent after extraction without silylation. Protocol two (P2) followed the direct supernatant collection after overnight extraction without drying and silylation. Protocol three (P3) included trimethylsilylation with N,O-bis(trimethylsilyl) trifluoroacetamide. Genotypic comparison of tocopherol and its isoforms revealed that Gaoyou 605 was dominant over the other genotypes with (140.5+ 10.5), (316.2+ 9.2), and (559.1+ 24.3) ~tg g-~ of seed meal ct-, 7-, and total (T-) tocopherol, respectively, and a 0.44+0.04 ^- to 7-tocopherol ratio. The comparison of the sample preparation protocols, on the other hand, suggests that P3 is the most suitable method for the tocopherol extraction from Brassica oilseeds and for the analysis of tocopherols using gas chromatography flame ionization detector (GC-FID). Trimethylsilylation is the key step differentiating P3 from P1 and P2. Variations detected in tocopherol contents among the Chinese rapeseed (B. napus) genotypes signify the need to quantify a wide range of rapeseed germplasm for seed tocopherol dynamics in short and crop improvement in long.展开更多
The infinite diluted activity coefficients of solvents in polyisopropyl methylacrylate was measured using inverse gas chromatography. The solvents used were benzene, toluene, ethyl benzene, methyl acetate, ethyl aceta...The infinite diluted activity coefficients of solvents in polyisopropyl methylacrylate was measured using inverse gas chromatography. The solvents used were benzene, toluene, ethyl benzene, methyl acetate, ethyl acetate, propyl acetate, butyl acetate, methanol, ethanol isopropyl alcohol, butyl alcohol, 1,2-dichloroethane, and chloroform. It was observed that the infinite diluted activity coefficient of alcohols are well above those of the other solvents investigated.展开更多
The present study describes guanidinium-based ionic liquids(GBILs) as stationary phases for capillary gas chromatography (CGC) and to the best of our knowledge,no related reports are available up to now.In this st...The present study describes guanidinium-based ionic liquids(GBILs) as stationary phases for capillary gas chromatography (CGC) and to the best of our knowledge,no related reports are available up to now.In this study,a hexaalkylguanidinium ionic liquid(DOTMG-NTf;) was synthesized and coated statically onto capillary columns.Selectivity of the stationary phase was evaluated by separating Grob test mixture,test mixture,alcohols mixture,and fatty acid methyl esters mixture,and thermal stability was investigated as well.The present study demonstrates that GBILs as CGC stationary phases exhibit satisfactory selectivity and thermal stability and have a great potential as new candidates for CGC stationary phases.展开更多
[ Objectives] This study was conducted to establish a QuEChERS-gas chromatography method for determination of eight kinds of organophosphorus pesticide residues in pepper. [Methods] The samples were extracted by aceto...[ Objectives] This study was conducted to establish a QuEChERS-gas chromatography method for determination of eight kinds of organophosphorus pesticide residues in pepper. [Methods] The samples were extracted by acetonitrile, and anhydrous magnesium sulfate was used for salting out. The extracts were then purified by dispersive solid phase extraction combining with GCB, C18 and PSA. Samples were analyzed by FPD detector. External standard was used as quantitive method. [ Results] The detection limits were in the range of 0. 001 -0. 008 mg/kg, the average recoveries ranged from 83.5% to 101.2% , and the relative standard deviation (RSD) of the eight organophosphorus pesticide residues were below 5%. [ Conclusions] The method is simple, quick, easy and effective for the determination of pepper.展开更多
A new ionic liquids grafted polysiloxane used as stationary phase for capillary gas chromatography (CGC) is described. The stationary phase of 1-vinyl-3-hexylimidazolium hexafluorophosphate anchored to polysiloxane ...A new ionic liquids grafted polysiloxane used as stationary phase for capillary gas chromatography (CGC) is described. The stationary phase of 1-vinyl-3-hexylimidazolium hexafluorophosphate anchored to polysiloxane (PMHS-[VHIm][PF6]) was synthe- sized, characterized and coated onto capillary columns by static coating. The results show that the present stationary phase exhibits a very good chromatographic resolution and selectivity for Grob test mixture and alcohols with baseline resolution and symmetry peaks. The present work suggests that novel stationary phase has a great potential for further development and application. 2009 Mei Ling Qi. Published by Elsevier B.V. on behalf of Chinese Chemical Society. All rights reserved.展开更多
One chloride-terminated ionic liquid(CTIL) and two hydroxyl-terminated ionic liquids(HTILs) were synthesized and used as stationary phases for capillary gas chromatography(CGC).Molecular interactions of these st...One chloride-terminated ionic liquid(CTIL) and two hydroxyl-terminated ionic liquids(HTILs) were synthesized and used as stationary phases for capillary gas chromatography(CGC).Molecular interactions of these stationary phases were evaluated by Abraham solvation parameter model,indicating that the CTIL exhibits remarkably strong H-bond basicity and the HTILs possess both H-bond basicity and acidity.The molecular interactions were further confirmed by separation of a complex mixture consisting of ketones,aldehydes,esters,alcohols and aromatic compounds.It was found that the obtained solvation parameters correlate well with the chromatographic performances of the analytes in terms of elution order and resolution.The well correlated relationship between the solvation parameters and the selectivity of the CTIL and HTILs stationary phases is quite helpful in predicting and understanding the retention behaviors of different types of analytes on these stationary phases.展开更多
Essential oil, with more than thirty kinds of compounds separated and identified by gas chromatography-mass spectrometry, was extracted from Shatian shaddock peel and Sweet shaddock peel by squeeze-steam distillation ...Essential oil, with more than thirty kinds of compounds separated and identified by gas chromatography-mass spectrometry, was extracted from Shatian shaddock peel and Sweet shaddock peel by squeeze-steam distillation and direct steam distillation method. Among their composition, the main components are terpene compounds, which account for 93.926% (mass fraction, the same below) and 85.843% of essential oils extracted from Shatian shaddock peel and Sweet shaddock peel, respectively. Although nootkatone is the major contributor of shaddock characteristic scent, and its contents are 1.069% and 1.749% of essential oils from Sweet shaddock peel and Shatian shaddock peel, respectively. The results show that squeeze-steam distillation gives higher yield and good quality of essential oil and the compositions of essential oils from two kinds of shaddock peels are different, but the main contributors of the shaddock scent are the same.展开更多
A new analytical procedure based on solid-phase extraction method coupled to GC-FID has been developed and validated for the determination of five phthalate esters (PAEs) (dimethyl-(DMP), diethyl-(DEP), di-n-bu...A new analytical procedure based on solid-phase extraction method coupled to GC-FID has been developed and validated for the determination of five phthalate esters (PAEs) (dimethyl-(DMP), diethyl-(DEP), di-n-butyl-(DBP), di-2-ethylhexyl- (DEHP), di-n-octyl-(DOP)) in fish samples. There was a good linear relationship in the range of 0.05-10μg with the detection limits of 0.09-0.16ng .The recoveries obtained for PAEs ranged from 88.6% to 96.4%with RSD of 4.2%-10.2%.The applicability of the developed method was demonstrated for real fish samples.展开更多
As a new technology of analyzing crude oils, comprehensive two-dimensional gas chromatography cou- pled with time-of-flight mass spectrometry (GCxGC- TOFMS) has received much research attention. Here we present a ca...As a new technology of analyzing crude oils, comprehensive two-dimensional gas chromatography cou- pled with time-of-flight mass spectrometry (GCxGC- TOFMS) has received much research attention. Here we present a case study in the Junggar Basin of NW China. Results show that the hydrocarbons, including saturates and aromatics, were all well-separated without large co- elution, which cannot be realized by conventional one-dimensional GC-MS. The GC×GC technique is especially effective for analyzing aromatics and low-to-middle- molecular-weight hydrocarbons, such as diamondoids. The geochemical characteristics of crude oils in the study area were investigated through geochemical parameters extracted by GC×GC-TOFMS, improving upon the understanding obtained by GC-MS. Thus, the work here represents a new successful application of GC×GC- TOFMS, showing its broad usefulness in petroleum geochemistry.展开更多
A guanidinium ionic liquid,N,N,N',N'-tetrahexyl-N",N"-dimethylguanidinium bis(trifluoromethane)sulfonylimide(THDMGNTf2), was synthesized and used as stationary phase for capillary gas chromatography.In compari...A guanidinium ionic liquid,N,N,N',N'-tetrahexyl-N",N"-dimethylguanidinium bis(trifluoromethane)sulfonylimide(THDMGNTf2), was synthesized and used as stationary phase for capillary gas chromatography.In comparison with imidazolium ionic liquid stationary phase,the present new stationary phase exhibits quite different selectivity and behaves more like a low polar stationary phase.The guanidinium ionic liquid of THDMG-NTf2 exhibited better separation of Grab test mixture than imidazolium ionic liquid of 1-octyl-3-butylimidazolium bis(trifluoromethane)sulfonylimide(OBIM-NTf2).Solvation parameter model was also used to evaluate the selectivity of THDMG-NTf2.Additionally,essential oil of Magnolia biondii Pamp was analyzed to further evaluate the selectivity of THDMG-NTf2 for a sample of complicated components.Satisfactory separation of the essential oil was achieved on a THDMG-NTf2 column(10 m) while using a commercial column(30 m) as reference.The present study shows that the guanidinium ionic liquid possesses novel chromatographic selectivity and has great potential for wide applications.展开更多
文摘A method for the assay of R ( ) and S (+) mexiletine in rat liver microsomal incubates was developed. The method involved extraction of mexiletine from the microsomal incubates, and formation of mexiletine diastereomeric derivatives with a chiral reagent S ( ) N trifluoroacetyl prolyl chloride. Separation and quantitation of the diastereomeric mexiletine derivatives were carried out by a capillary gas chromatographic system with flame ionization detection. The assay was linear from 5 to 500 μg/ml for each enantiomer. The average recoveries of analytical method were 93 31±5 59% and 93 10±5 11% for R ( ) and S (+) mexiletine, respectively. The limits of detection and quantitation for the method were 1 0 μg/ml and 5 0 μg/ml for the R ( ) and S (+) mexiletine isomers, respectively. The reproducibility in the assay was better than 16.5% (RSD). The method has been applied to the metabolism study of R ( ) and S (+) mexiletine in rat liver microsomal incubates.
文摘A new compound of mono 6 (1' benzo aza 15 crown 5) 2,3,6 permethyl β cyclodextrin (BA 15C5 PM CD) was synthesized. The structure was determined to be coincide with our anticipation by spectroscopy. As a stationary phase for capillary gas chromatography, excellent separation for enantiomers and positional isomers was achieved.
文摘Background: Impurities are not expected in the final pharmaceutical products. All impurities should be regulated in both drug substances and drug products in accordance with pharmacopeias and ICH guidelines. Three different types of impurities are generally available in the pharmaceutical’s product specification: organic impurities, inorganic impurities, and residual solvents. Residual solvents are organic volatile chemicals used or generated during the manufacturing of drug substances or drug products. Purpose: The aim of this study is to develop a cost-effective gas chromatographic method for the identification and quantification of some commonly used solvents—methanol, acetone, isopropyl alcohol (IPA), methylene chloride, ethyl acetate, tetrahydrofuran (THF), benzene, toluene, and pyridine—in pharmaceutical product manufacturing. This method will be able to identify and quantify the multiple solvents within a single gas chromatographic procedure. Method: A gas chromatography (GC) equipped with a headspace sampler and a flame ionization detector, and a column DB 624, 30-meter-long × 0.32-millimeter internal diameter, 1,8 μm-thick, Brand-Agilent was used to develop this method. The initial GC oven temperature was 40°C and held for 5 minutes. It was then increase to 80˚C at a rate of 2˚C per minute, followed by a further increase to 225˚C at a rate of 30˚C per minute, with a final hold at 225˚C for 10 minutes. Nitrogen was used as a carrier gas at a flow rate of 1.20 mL per minute. Dimethyl sulfoxide (DMSO) was selected as sample solvent. Results: The developed method is precise and specific. The percent RSD for the areas of six replicate injections of this gas chromatographic method was within 10.0 and the recovery result found within 80.0% to 120.0%.
文摘The combination of pyrolysis high resolution gas chromatography and pat- tern recognition techniques is a powerful tool for the classification of traditional Chinese drug.A study has been completed on 55 Beimu samples of five different geographic origins: Eastern China.Central China.South-western China,North-western China and North-eastern China.Principal component analysis and SIMCA are applied to effectively classifying the samples according to the origin of the plants.The chemical information contained in the high resolution gas chromatographic data is sufficient to characterize the geographic origin of sam- pies.
文摘A method for the determination of dichlofluanid residue by Capillary Collumns Gas Chromatography was established in this study.Samples were extracted with acetone and subjected to through liquid-liquid extraction with N-hexane,and then they were cleanup with column that filled with florisil,subsequently separated by Capillary Column Gas Chromatography,and the electron capture detector (ECD) was used for detection.The detection limit of this method was 0.005 mg/kg (S/N=3),and this method was rapid,sensitive and accurate,and was applied in the determination of dichlofluanid residue in soybean.
文摘A new capillary gas chromatography stationary phase, monokis (2,6 di O benzyl 3 O propyl (3’)) hexakis(2,6 di O benzyl 3 O methyl) β CD bonded polysiloxane, was synthesized. It exhibited separation abilities to disubstituted benzene isomers and some chiral solutes. It was also found that the polarity of CD derivatives can be lowered both by chemically bonding it to polysiloxane and by diluting it in polysiloxane. The separation abilities of the polysiloxane anchored CDs (SP CD) are higher than that of the unbonded CDs (S CD) and the diluted S CD at lower column temperature. Hydrosilylation reaction is one of the best methods to lower the operating temperature of CDs.
基金The National Basic Research Program of China(973Program)(No.2012CB933302)the National Instrumental Research Program(No.2014YQ06077303)+1 种基金the National Natural Science Foundation of China(No.81172720,21307086)Suzhou Science and Technology Department Foundation(No.ZXG201441)
文摘A new method for simultaneous determination of four phthalate esters ( PAEs) in commercial fat-containing foods was developed by the combination of a packed nanofibers column based on solid-phase extraction with gas chromatography-flame ionization detector ( GC-FID ). Conditions for obtaining optimum extraction efficiency such as extraction solvents, morphologies of adsorbent, ion strength and pH were investigated and optimized in detail. Under the optimized conditions, the limits of detection (LODs) found for dibutyl phthalate (DBP) , butyl benzyl phthalate (BBP), diethyl hexyl phthalate (DEHP) and di-n-octyl phthalate (DNOP) were 50, 25, 50 and 25 ng/g, respectively. Good linearity of four PAEs was achieved in the range of 50 to 4 000 ng/g. The proposed method was applied for analyzing different kinds of fat-containing samples. PAEs in commercial fat-containing samples can be highly extracted by a packed solid-phase extraction column of 5 mg polystyrene ( PS) nanofibers. The satisfactory average recoveries were obtained in the range of 96. 7% to 102. 3% , and the relative standard deviations (RSDs) below 5% were achieved. The proposed method reduces the organic solvent consumption, the complex and tedious procedures for sample pretreatment, and achieves high sensitivity and reproducibility for the investigated PAEs.
文摘The composition and sequence distribution of monomeric units in polyester polyether multiblock copolymer were studied by pyrolysis? gas chromatography (PGC) and pyrolysis gas chromatography/mass spectrometry (PGC/MS). PGC was applied to study the F t curve of the multiblock copolymer and PGC/MS was used to separate and identify the pyrolyzates. DTA experiment was used to study the decomposition temperature. The results show that the beginning point of elastomer’s decomposition was about 300?℃ and the decomposition temperature of most of the sample was 550?℃. Many pyrolyzates were produced because of the breaking of weak bonds in the sample. The possible microstructure was verified and the pyrolysis pathway of the copolymer was investigated.
文摘Applications of pyrolysis-gas chromatography and pyrolysis capillary gas chromatography in explosive and propellant analysis are reviewed, including the identification of explosives and propel- lants, the investigation of the thermal decomposition of nitrocellulose (NC), cyclotetramethylene tetranitramine (HMX)and cyclotrimethylene trinitramine (RDX), and the study of the wear- reducing mechanism of polyurethane additive in propellant gain.
文摘The cross-linking of crown ether-SE-54 in fused-silica capillary columns were initiated by dicumyl peroxide(DCUP),azo-bis-isobutyronitrile (AIBN)and ozone(O_3).Parameters of evaluation such as polarity,selectivity, phase transition temperature and thermal stability were studied and compared with those of poly(crown ether)stationary phase.
基金supported by the National Natural Science Foundation of China (30971700 and 31171463)Natural Science Foundation of Zhejiang Province (Z3100130)
文摘The variation among Chinese genotypes of Brassica napus L. for seed tocopherols content and their analysis using gas chromatography has not been comprehensively reported till to date. In the present study, the tocopherol contents of four Chinese genotypes of Brassica napus L., namely, Gaoyou 605, Zhejiang 619, Zheshuang 758, and Zheshuang 72, were evaluated using three modified sample preparation protocols (P1, P2, and P3) for tocopherol extraction. These methods were distinguished as follows. Protocol one (P1) included the evaporation of solvent after extraction without silylation. Protocol two (P2) followed the direct supernatant collection after overnight extraction without drying and silylation. Protocol three (P3) included trimethylsilylation with N,O-bis(trimethylsilyl) trifluoroacetamide. Genotypic comparison of tocopherol and its isoforms revealed that Gaoyou 605 was dominant over the other genotypes with (140.5+ 10.5), (316.2+ 9.2), and (559.1+ 24.3) ~tg g-~ of seed meal ct-, 7-, and total (T-) tocopherol, respectively, and a 0.44+0.04 ^- to 7-tocopherol ratio. The comparison of the sample preparation protocols, on the other hand, suggests that P3 is the most suitable method for the tocopherol extraction from Brassica oilseeds and for the analysis of tocopherols using gas chromatography flame ionization detector (GC-FID). Trimethylsilylation is the key step differentiating P3 from P1 and P2. Variations detected in tocopherol contents among the Chinese rapeseed (B. napus) genotypes signify the need to quantify a wide range of rapeseed germplasm for seed tocopherol dynamics in short and crop improvement in long.
基金Supported by the National Natural Science Foundation of China(No.29736170,No.29976011)
文摘The infinite diluted activity coefficients of solvents in polyisopropyl methylacrylate was measured using inverse gas chromatography. The solvents used were benzene, toluene, ethyl benzene, methyl acetate, ethyl acetate, propyl acetate, butyl acetate, methanol, ethanol isopropyl alcohol, butyl alcohol, 1,2-dichloroethane, and chloroform. It was observed that the infinite diluted activity coefficient of alcohols are well above those of the other solvents investigated.
基金the National Nature Science Foundation of China(No.20675007)
文摘The present study describes guanidinium-based ionic liquids(GBILs) as stationary phases for capillary gas chromatography (CGC) and to the best of our knowledge,no related reports are available up to now.In this study,a hexaalkylguanidinium ionic liquid(DOTMG-NTf;) was synthesized and coated statically onto capillary columns.Selectivity of the stationary phase was evaluated by separating Grob test mixture,test mixture,alcohols mixture,and fatty acid methyl esters mixture,and thermal stability was investigated as well.The present study demonstrates that GBILs as CGC stationary phases exhibit satisfactory selectivity and thermal stability and have a great potential as new candidates for CGC stationary phases.
基金Supported by Post-doctoral Scientific Fund of China(No.2017M611382)Autonomy Program of Economy,Trade and Information Commission of Shenzhen Municipality(No.20170427160059840)
文摘[ Objectives] This study was conducted to establish a QuEChERS-gas chromatography method for determination of eight kinds of organophosphorus pesticide residues in pepper. [Methods] The samples were extracted by acetonitrile, and anhydrous magnesium sulfate was used for salting out. The extracts were then purified by dispersive solid phase extraction combining with GCB, C18 and PSA. Samples were analyzed by FPD detector. External standard was used as quantitive method. [ Results] The detection limits were in the range of 0. 001 -0. 008 mg/kg, the average recoveries ranged from 83.5% to 101.2% , and the relative standard deviation (RSD) of the eight organophosphorus pesticide residues were below 5%. [ Conclusions] The method is simple, quick, easy and effective for the determination of pepper.
基金the National Natural Science Foundation of China for the funding(No.20675007)
文摘A new ionic liquids grafted polysiloxane used as stationary phase for capillary gas chromatography (CGC) is described. The stationary phase of 1-vinyl-3-hexylimidazolium hexafluorophosphate anchored to polysiloxane (PMHS-[VHIm][PF6]) was synthe- sized, characterized and coated onto capillary columns by static coating. The results show that the present stationary phase exhibits a very good chromatographic resolution and selectivity for Grob test mixture and alcohols with baseline resolution and symmetry peaks. The present work suggests that novel stationary phase has a great potential for further development and application. 2009 Mei Ling Qi. Published by Elsevier B.V. on behalf of Chinese Chemical Society. All rights reserved.
基金the National Nature Science Foundation of China(No.20675007).
文摘One chloride-terminated ionic liquid(CTIL) and two hydroxyl-terminated ionic liquids(HTILs) were synthesized and used as stationary phases for capillary gas chromatography(CGC).Molecular interactions of these stationary phases were evaluated by Abraham solvation parameter model,indicating that the CTIL exhibits remarkably strong H-bond basicity and the HTILs possess both H-bond basicity and acidity.The molecular interactions were further confirmed by separation of a complex mixture consisting of ketones,aldehydes,esters,alcohols and aromatic compounds.It was found that the obtained solvation parameters correlate well with the chromatographic performances of the analytes in terms of elution order and resolution.The well correlated relationship between the solvation parameters and the selectivity of the CTIL and HTILs stationary phases is quite helpful in predicting and understanding the retention behaviors of different types of analytes on these stationary phases.
文摘Essential oil, with more than thirty kinds of compounds separated and identified by gas chromatography-mass spectrometry, was extracted from Shatian shaddock peel and Sweet shaddock peel by squeeze-steam distillation and direct steam distillation method. Among their composition, the main components are terpene compounds, which account for 93.926% (mass fraction, the same below) and 85.843% of essential oils extracted from Shatian shaddock peel and Sweet shaddock peel, respectively. Although nootkatone is the major contributor of shaddock characteristic scent, and its contents are 1.069% and 1.749% of essential oils from Sweet shaddock peel and Shatian shaddock peel, respectively. The results show that squeeze-steam distillation gives higher yield and good quality of essential oil and the compositions of essential oils from two kinds of shaddock peels are different, but the main contributors of the shaddock scent are the same.
文摘A new analytical procedure based on solid-phase extraction method coupled to GC-FID has been developed and validated for the determination of five phthalate esters (PAEs) (dimethyl-(DMP), diethyl-(DEP), di-n-butyl-(DBP), di-2-ethylhexyl- (DEHP), di-n-octyl-(DOP)) in fish samples. There was a good linear relationship in the range of 0.05-10μg with the detection limits of 0.09-0.16ng .The recoveries obtained for PAEs ranged from 88.6% to 96.4%with RSD of 4.2%-10.2%.The applicability of the developed method was demonstrated for real fish samples.
基金funded by the Major State Basic Research Development Program of China(973 project,Grant No.2012CB214803)National Science and Technology Major Project of China(Grant No. 2016ZX05003-005)National Natural Science Foundation of China(Grant Nos.41322017 and 41472100)
文摘As a new technology of analyzing crude oils, comprehensive two-dimensional gas chromatography cou- pled with time-of-flight mass spectrometry (GCxGC- TOFMS) has received much research attention. Here we present a case study in the Junggar Basin of NW China. Results show that the hydrocarbons, including saturates and aromatics, were all well-separated without large co- elution, which cannot be realized by conventional one-dimensional GC-MS. The GC×GC technique is especially effective for analyzing aromatics and low-to-middle- molecular-weight hydrocarbons, such as diamondoids. The geochemical characteristics of crude oils in the study area were investigated through geochemical parameters extracted by GC×GC-TOFMS, improving upon the understanding obtained by GC-MS. Thus, the work here represents a new successful application of GC×GC- TOFMS, showing its broad usefulness in petroleum geochemistry.
基金the National Nature Science Foundation of China(No.20675007)
文摘A guanidinium ionic liquid,N,N,N',N'-tetrahexyl-N",N"-dimethylguanidinium bis(trifluoromethane)sulfonylimide(THDMGNTf2), was synthesized and used as stationary phase for capillary gas chromatography.In comparison with imidazolium ionic liquid stationary phase,the present new stationary phase exhibits quite different selectivity and behaves more like a low polar stationary phase.The guanidinium ionic liquid of THDMG-NTf2 exhibited better separation of Grab test mixture than imidazolium ionic liquid of 1-octyl-3-butylimidazolium bis(trifluoromethane)sulfonylimide(OBIM-NTf2).Solvation parameter model was also used to evaluate the selectivity of THDMG-NTf2.Additionally,essential oil of Magnolia biondii Pamp was analyzed to further evaluate the selectivity of THDMG-NTf2 for a sample of complicated components.Satisfactory separation of the essential oil was achieved on a THDMG-NTf2 column(10 m) while using a commercial column(30 m) as reference.The present study shows that the guanidinium ionic liquid possesses novel chromatographic selectivity and has great potential for wide applications.