期刊文献+
共找到120篇文章
< 1 2 6 >
每页显示 20 50 100
Comparison between Spectrophotometry and Gas Phase Molecular Absorption Spectrometry for Determination of Nitrite Nitrogen in Flue Gas
1
作者 Jun SUN Tianjun DU Hualin GONG 《Meteorological and Environmental Research》 CAS 2022年第6期60-62,共3页
Spectrophotometry and gas phase molecular absorption spectrometry for determination of nitrite nitrogen in flue gas were compared.KOH absorption solution was used to absorb nitrite nitrogen in flue gas,and the concent... Spectrophotometry and gas phase molecular absorption spectrometry for determination of nitrite nitrogen in flue gas were compared.KOH absorption solution was used to absorb nitrite nitrogen in flue gas,and the concentration of nitrite nitrogen in the absorption solution was determined by spectrophotometry and gas phase molecular absorption spectrometry to obtain the concentration of nitrite nitrogen in flue gas.The experiments show that both methods are accurate and reliable. 展开更多
关键词 SPECTROPHOTOMETRY gas phase molecular absorption spectrometry Flue gas Nitrite nitrogen COMPARISON
下载PDF
气相分子吸收光谱法测定水中氨氮的方法验证
2
作者 李荧荧 《中国标准化》 2024年第20期173-177,共5页
本文采用《水质氨氮的测定气相分子吸收光谱法》(HJ 195—2023)进行方法验证研究,验证内容主要包括标准曲线、方法检出限和测定下限、精密度、准确度等方面,分析以上测定结果表明,标准曲线相关系数r>0.999,检出限为0.01 mg/L,测定下... 本文采用《水质氨氮的测定气相分子吸收光谱法》(HJ 195—2023)进行方法验证研究,验证内容主要包括标准曲线、方法检出限和测定下限、精密度、准确度等方面,分析以上测定结果表明,标准曲线相关系数r>0.999,检出限为0.01 mg/L,测定下限为0.02 mg/L,有证标准物质测试结果均在合格范围内,加标回收率在97.0%~105.8%之间,所有性能指标验证结果均满足标准方法的各项要求,本实验室具备开展气相分子吸收光谱法测定水中氨氮的检测能力。 展开更多
关键词 氨氮 气相分子吸收光谱 方法验证
下载PDF
三种测定水中氨氮含量的方法比对研究
3
作者 李芳霞 刘洋 王赵芳 《广州化工》 CAS 2024年第17期86-88,共3页
用纳氏试剂分光光度法、气相分子吸收光谱法和连续流动注射法分别测定地下水、地表水和废水中氨氮含量,对检测结果进行F和t检验,结果表明三种方法测定水中氨氮含量无显著性差异,校准曲线线性、检出限等指标均符合相关要求。实际工作中,... 用纳氏试剂分光光度法、气相分子吸收光谱法和连续流动注射法分别测定地下水、地表水和废水中氨氮含量,对检测结果进行F和t检验,结果表明三种方法测定水中氨氮含量无显著性差异,校准曲线线性、检出限等指标均符合相关要求。实际工作中,在不加固定剂室温密封储存条件下,水样最好在24 h之内进行分析,样品量较少可选用纳氏试剂分光光度法测定,样品量较大可选用气相分子吸收光谱法或连续流动注射法,优先选用连续流动注射法。 展开更多
关键词 氨氮 测定方法 纳氏试剂分光光度法 连续流动注射法 气相分子吸收光谱法
下载PDF
气相色谱-负化学源质谱联用法测定水产品及食用油中氟乐灵的残留量 被引量:9
4
作者 王莉 夏广辉 +5 位作者 沈伟健 吴斌 张睿 陆慧媛 沈崇钰 赵增运 《色谱》 CAS CSCD 北大核心 2014年第3期314-317,共4页
建立了一种可用于水产品及食用油中氟乐灵残留量分析的分散型固相萃取-气相色谱-负化学离子源质谱方法。水产品及食用油经乙腈提取,4℃冷藏后,采用分散型固相萃取法净化,由气相色谱-负化学离子源质谱选择离子监测技术进行测定与确证... 建立了一种可用于水产品及食用油中氟乐灵残留量分析的分散型固相萃取-气相色谱-负化学离子源质谱方法。水产品及食用油经乙腈提取,4℃冷藏后,采用分散型固相萃取法净化,由气相色谱-负化学离子源质谱选择离子监测技术进行测定与确证,同位素内标法定量。在1~40μg / L 范围内氟乐灵农药的线性关系良好;方法定量限(LOQ)为0.02μg / kg;对鳗鱼、烤鳗、梭子蟹、小龙虾、猪油和橄榄油等6种复杂基质进行1.0、2.0和3.0μg / kg 等3个水平的添加回收试验,平均回收率均处于80%~100%之间,RSD≤10.3%;无干扰现象出现。该方法可作为水产品及食用油中氟乐灵残留检测的确证方法。 展开更多
关键词 分散型固相萃取 气相色谱-负化学离子源质谱联用 选择离子监测 氟乐灵 水产品 食用油 disperse solid phase extraction( DSPE) gas chromatography-negative chemical ionization mass spectrometry ( GC-MS NCI ) selected ion monitoring ( SIM )
下载PDF
超声辅助提取-气相分子吸收光谱法测定火腿中亚硝酸盐 被引量:2
5
作者 刘丰奎 汪雨 +4 位作者 钱春燕 李杰 姜雪成 邵鹏 祖文川 《分析科学学报》 CAS CSCD 北大核心 2022年第1期89-93,共5页
建立了超声辅助提取,气相分子吸收光谱法测定火腿中亚硝酸盐含量的高效、高灵敏分析方法。采用纯水提取火腿中的亚硝酸盐,对室温提取、水浴热提法和超声辅助提取法对火腿中亚硝酸盐的提取效率进行了比较。结果表明:超声辅助提取法对火... 建立了超声辅助提取,气相分子吸收光谱法测定火腿中亚硝酸盐含量的高效、高灵敏分析方法。采用纯水提取火腿中的亚硝酸盐,对室温提取、水浴热提法和超声辅助提取法对火腿中亚硝酸盐的提取效率进行了比较。结果表明:超声辅助提取法对火腿中亚硝酸盐的提取效率最佳。探究了超声提取时间及提取温度对火腿中亚硝酸盐提取的影响,结果表明:采用该法在60℃下,30 min内,可以实现对火腿中亚硝酸盐的充分和稳定性提取。在优化的实验条件下,本方法应用于火腿中亚硝酸盐含量的测定,方法检出限为44.0μg/kg(以NO_(2)-N计);对实际火腿样品中亚硝酸盐的5次重复测试的相对标准偏差为3.1%;回收率在87.7%-111.6%之间。该方法准确可靠,较之传统离子色谱法及分光光度法,本法兼具灵敏和快速的优势,可以在火腿中亚硝酸盐检测领域推广应用。 展开更多
关键词 气相分子吸收光谱法 超声辅助提取 亚硝酸盐 火腿
下载PDF
福建姜黄挥发油化学成分的HS-SPME-GC-MS分析 被引量:16
6
作者 强悦越 韦航 +4 位作者 方灵 吴妙鸿 谭索 曾绍校 傅建炜 《中国食品添加剂》 CAS 2020年第1期147-153,共7页
采用水蒸气蒸馏法提取福建姜黄挥发油,应用顶空固相微萃取进样结合气相色谱-串联质谱联用技术(HS-SPME-GC-MS)分析姜黄挥发油的化学成分。结果表明:姜黄挥发油含有量为7.2%(mL/g),从姜黄挥发油中共分出62个色谱峰,初步鉴定出了其中的51... 采用水蒸气蒸馏法提取福建姜黄挥发油,应用顶空固相微萃取进样结合气相色谱-串联质谱联用技术(HS-SPME-GC-MS)分析姜黄挥发油的化学成分。结果表明:姜黄挥发油含有量为7.2%(mL/g),从姜黄挥发油中共分出62个色谱峰,初步鉴定出了其中的51种化学成分,占总挥发油总量的98.41%。在鉴定的化合物中,主要为单萜类化合物和倍半萜类化合物,其中新发现一种主要成分为β-柏木烯,相对含量占比高达26.58%,这可作为福建姜黄挥发油的特征成分和主要品质指标。本研究结果将为福建姜黄植物药材的品质评价提供科学依据。 展开更多
关键词 姜黄挥发油 顶空固相微萃取技术(Head space solid phase micro-extraction HS-SPME) 气相色谱-质谱联用技术(gas chromatography-mass spectrometry GC-MS) 化学成分
下载PDF
在线消解-气相分子吸收光谱法测定水质中总氮 被引量:4
7
作者 王文波 《分析仪器》 CAS 2018年第5期79-83,共5页
在线紫外灯加热消解和气相分子吸收光谱技术相结合,形成可实现水质中总氮包括有机氮和无机氮的全自动的检测系统。该系统可自动地执行采样、加热消解、数据测定、数据分析的全过程。通过试验测定,确定该系统的最佳测定条件。并且此系统... 在线紫外灯加热消解和气相分子吸收光谱技术相结合,形成可实现水质中总氮包括有机氮和无机氮的全自动的检测系统。该系统可自动地执行采样、加热消解、数据测定、数据分析的全过程。通过试验测定,确定该系统的最佳测定条件。并且此系统消耗试剂量少(25mL),测定范围宽(0.150~100mg/L),检出限低(0.032mg/L),测定快速(8min),精密度高(RSD<1.2%),实际水样的加标回收率均在97.1%~102.31%之内,可用于在线快速测定总氮。 展开更多
关键词 总氮 在线紫外消解 气相分子吸收光谱
下载PDF
氯化钾提取-气相分子吸收光谱法测定土壤中的氨氮 被引量:3
8
作者 吕保玉 潘艳 +1 位作者 蓝月存 白海强 《化学工程师》 CAS 2019年第9期28-30,共3页
为了探讨KCl提取-气相分子吸收光谱法测定土壤中NH4-N的可行性,测定了不同利用类型土壤中的NH4-N。通过测试检出限、样品均值、精密度、准确度等指标,得出该方法检出限0.065mg·kg-1、加标回收率在94.0%~101.5%、同一样品平行测定5... 为了探讨KCl提取-气相分子吸收光谱法测定土壤中NH4-N的可行性,测定了不同利用类型土壤中的NH4-N。通过测试检出限、样品均值、精密度、准确度等指标,得出该方法检出限0.065mg·kg-1、加标回收率在94.0%~101.5%、同一样品平行测定5次的相对标准差小于3%,证明了气相分子吸收光谱法在实际测试中完全满足土壤NH4-N测量的需求,并通过与行标苯酚显色法的对比试验,t检验显示两种方法在精密度、准确度等方面均无显著差异,测定结果有较好的一致性。 展开更多
关键词 气相分子吸收光谱法 氯化钾 土壤 氨氮
下载PDF
旋转混合-气相分子吸收光谱法测定土壤阳离子交换量 被引量:4
9
作者 刘雪妮 叶文容 +1 位作者 郝桂娟 唐霞 《广东化工》 CAS 2021年第6期124-126,共3页
为解决土壤阳离子交换量国标测定方法繁琐且自动化程度低的问题,进行了气相分子吸收光谱法应用于阳离子交换量测定的方法探究。前处理采用乙酸铵交换-乙醇洗涤法处理土壤,旋转混合仪转速80 r,时间4 min,各交换3次后用半自动蒸馏仪进行蒸... 为解决土壤阳离子交换量国标测定方法繁琐且自动化程度低的问题,进行了气相分子吸收光谱法应用于阳离子交换量测定的方法探究。前处理采用乙酸铵交换-乙醇洗涤法处理土壤,旋转混合仪转速80 r,时间4 min,各交换3次后用半自动蒸馏仪进行蒸馏,蒸馏出的氨经硼酸溶液吸收后,吸收液采用气相分子吸收光谱法测定氨氮的程序得出浓度,结果换算为阳离子交换量的值。用四种土壤标准物质验证方法,阳离子交换量检测结果均在标准物质证书参考值范围之内,其相对标准偏差(n=6)小于1.2%,与全自动凯氏定氮仪做结果比对,相对误差在-2.0~2.9之间。结果表明气相分子吸收光谱法可应用于土壤阳离子交换量的测定。 展开更多
关键词 旋转混合 乙酸铵 氨氮 蒸馏 气相分子吸收光谱法
下载PDF
Preparation and adsorption behaviors of Cu(Ⅱ) ion-imprinted polymers
10
作者 钟世安 《Journal of Chongqing University》 CAS 2008年第1期23-27,共5页
Imprinted polymers were prepared for selective removal of Cu(Ⅱ) ions from metal solutions. Three ion-imprinted polymers were synthesized with methacrylic acid (MAA), acrylamide (AA) and N,N'-methylenebisacryla... Imprinted polymers were prepared for selective removal of Cu(Ⅱ) ions from metal solutions. Three ion-imprinted polymers were synthesized with methacrylic acid (MAA), acrylamide (AA) and N,N'-methylenebisacrylamide (MBAA) respectively as the functional monomers, ethleneglycoldimethacrylate (EGDMA) as the cross-linking agent, 2,2'- azobisisobutyronitrile (AIBN) as the initiator and Cu (Ⅱ) ion as the imprint ion. The template Cu (Ⅱ) ion was removed from the polymer by leaching with a liquid of a 1:1 volumetric ratio of HCl to ethylenediaminetetraacetic acid (EDTA). The capacity and selectivity of Cu(Ⅱ) ion adsorption were investigated with the three imprinted polymers and their non-imprinted counterparts. The polymers have a maximum adsorption capacity at pH 7.0. The isotherm of their batch adsorption of Cu(Ⅱ) ions shows a Langmuir adsorption pattern. Imprinted polymers all have a much higher capacity and higher selectivity of Cu(Ⅱ) adsorption than nonimprinted ones. MAA polymer benefits the most from imprinting. Imprinted MAA polymer has the highest selectivity when used to rebind Cu (Ⅱ) ion from an aqueous solution in the presence of other metal ions. Ion imprinting can be a promising technique of preparing selective adsorbents to separate and preconcentrate metal in a medium of multiple competitive metal ions through solid phase extraction (SPE). 展开更多
关键词 molecular recognition COMPLEXATION metal ion imprinted polymer PRECONCENTRATION solid phase extraction atomic absorption spectrometry copper ion selective adsorption
下载PDF
气相分子吸收光谱法测定水中硝酸盐氮 被引量:2
11
作者 陈莹 白昕 +4 位作者 王伟华 马倩 薛荔栋 陈烨 张霖琳 《中国无机分析化学》 CAS 北大核心 2023年第4期330-334,共5页
硝酸盐氮是水环境质量重点监测项目之一,建立节省人力、高效快捷、抗干扰能力强的测定水中硝酸盐氮的方法十分必要。从载气类型、载气流量、定量方式、加热温度、载流液配比等方面系统地优化气相分子吸收光谱法测定水中硝酸盐氮的仪器... 硝酸盐氮是水环境质量重点监测项目之一,建立节省人力、高效快捷、抗干扰能力强的测定水中硝酸盐氮的方法十分必要。从载气类型、载气流量、定量方式、加热温度、载流液配比等方面系统地优化气相分子吸收光谱法测定水中硝酸盐氮的仪器条件。在优化的仪器条件下,工作曲线相关系数为0.9995;检出限为0.006 mg/L,测定下限为0.024 mg/L;标准物质测定的相对误差在0~0.60%,实际样品测定的相对标准偏差在0.50%~5.5%;实际样品加标回收率在89.0%~102%。方法的检出限、精密度和正确度良好,适用于水质硝酸盐氮的测定。 展开更多
关键词 水质 硝酸盐氮 气相分子吸收光谱法
下载PDF
无特殊前处理条件下清洁水中低浓度氨氮测定方法的比对 被引量:5
12
作者 周敬峰 朱红霞 +3 位作者 王婷 姜丽 金淑聪 胡佳欣 《中国环境监测》 CAS CSCD 北大核心 2023年第5期218-225,共8页
清洁水中低浓度氨氮的准确定量一直备受关注,相关标准方法中建议清洁水可直接取样测定,故在实际监测过程中常出现方法间不可比的现象。选用氨氮测试的纳氏试剂分光光度法、气相分子吸收法和离子色谱法,比较各方法在未经前处理条件下的... 清洁水中低浓度氨氮的准确定量一直备受关注,相关标准方法中建议清洁水可直接取样测定,故在实际监测过程中常出现方法间不可比的现象。选用氨氮测试的纳氏试剂分光光度法、气相分子吸收法和离子色谱法,比较各方法在未经前处理条件下的检出限。使用氨氮含量较低的清洁水,分析其在pH、色度、浊度、硬度、氯离子、钠离子和硫化物等干扰存在下的测定结果,进而探讨在不同干扰条件下更适合清洁水中低浓度氨氮的测定方法。应用氨氮浓度较低的清洁地表水和地下水进行了方法间的比对,结果表明,对于清洁水,直接取样测定时需结合氨氮浓度水平和干扰情况选择适合的方法,必要时进行统一的前处理方能提高方法间的可比性。 展开更多
关键词 清洁水 低浓度氨氮 纳氏试剂分光光度法 气相分子吸收法 离子色谱法
下载PDF
气相分子吸收光谱法测定环境空气和废气中氨的含量 被引量:1
13
作者 张琤 黎文豪 +4 位作者 肖文 潘燕华 陆国永 高明 党志 《理化检验(化学分册)》 CAS CSCD 北大核心 2023年第4期461-466,共6页
提出了气相分子吸收光谱法测定环境空气和废气中氨含量的方法。采集环境空气样品时,使用25 mL吸收管,加入25 mL 0.01 mol·L^(-1)硫酸溶液作为吸收液,以流量1.5 L·min^(-1)采样0.5~1.0 h;采集废气样品时,使用50 mL吸收管,加入5... 提出了气相分子吸收光谱法测定环境空气和废气中氨含量的方法。采集环境空气样品时,使用25 mL吸收管,加入25 mL 0.01 mol·L^(-1)硫酸溶液作为吸收液,以流量1.5 L·min^(-1)采样0.5~1.0 h;采集废气样品时,使用50 mL吸收管,加入50 mL 0.01 mol·L^(-1)硫酸溶液作为吸收液,以流量0.5 L·min^(-1)采样0.5 h。设置气相分子吸收光谱仪检测波长为214.7 nm(氘灯光源)或213.9 nm(锌空心阴极灯光源),加热温度为80~90℃。通过干扰试验,证实了Mn^(2+)、苯胺、抗坏血酸、Mn^(7+)、ClO^(-)会对氨的测定产生干扰,可通过氧化法、还原法、蒸馏法、稀释法对上述干扰物质进行消除。以质量浓度不大于14.0 mg·L^(-1)的氨标准溶液系列作为绘制校准曲线的母液。结果表明,氨校准曲线线性范围在4.00 mg·L^(-1)以内,方法检出限为0.008 mg·m^(-3)(环境空气)和0.03 mg·m^(-3)(废气)。对实际环境空气和废气样品分别进行3个浓度水平的加标回收试验,回收率为97.9%~106%,氨测定值的相对标准偏差(n=6)不大于2.5%,并通过配对样本F检验法确定该方法与现行有效的纳氏试剂分光光度法无显著性差异。 展开更多
关键词 气相分子吸收光谱法 环境空气 废气
下载PDF
气相分子吸收光谱法测定工业废气中氨含量 被引量:1
14
作者 谢璇 徐强 +1 位作者 郑琳琳 李海滨 《化学工程师》 CAS 2023年第4期18-20,共3页
本文建立了气相分子吸收光谱法检测工业废气中NH3含量的方法。实验结果表明,在线性范围内,线性相关系数良好,精密度、准确度均可以满足环境监测分析的要求。该方法灵敏度高、重复性好,不需要进行样品前处理,不需要使用剧毒的化学试剂。... 本文建立了气相分子吸收光谱法检测工业废气中NH3含量的方法。实验结果表明,在线性范围内,线性相关系数良好,精密度、准确度均可以满足环境监测分析的要求。该方法灵敏度高、重复性好,不需要进行样品前处理,不需要使用剧毒的化学试剂。与传统的国家标准方法比较,该方法测定结果没有显著性差异,能够准确检测工业废气中NH3的含量,是一种值得推广应用的分析方法。 展开更多
关键词 气相分子吸收光谱法 工业废气 方法对比
下载PDF
气相分子吸收法快速测定工业废水中硫化物
15
作者 王昭 赵彬 姚帮本 《化学分析计量》 CAS 2023年第10期39-43,共5页
建立气相分子吸收法快速测定工业废水中硫化物的方法。水样经乙酸锌溶液固定后转化成硫化锌沉淀,硫化锌沉淀与盐酸反应转化成硫化氢,用载气将硫化氢气体载入气相分子吸收光谱仪的吸光管中,于202.6nm波长处测定吸光度,吸光度与硫化物质... 建立气相分子吸收法快速测定工业废水中硫化物的方法。水样经乙酸锌溶液固定后转化成硫化锌沉淀,硫化锌沉淀与盐酸反应转化成硫化氢,用载气将硫化氢气体载入气相分子吸收光谱仪的吸光管中,于202.6nm波长处测定吸光度,吸光度与硫化物质量浓度之间的关系符合朗伯-比尔定律。硫化物质量浓度在0.02~10.0mg/L范围内与吸光度线性关系良好,相关系数为0.9996,方法检出限为0.005mg/L。采用所建方法分别对水质硫化物标准样品、硫化物标准溶液和加标工业废水平行测定6次,测定值的相对标准偏差为1.3%~7.9%。对水质硫化物标准样品和硫化物标准溶液进行测定,测定值与标准值基本一致,相对误差为-5.0%~2.3%。含硫和不含硫工业废水实际样品的加标回收率分别为85.6%和80.1%。该方法快速、灵敏、准确,可用于工业废水中硫化物的检测。 展开更多
关键词 硫化物 气相分子吸收光谱法 工业废水
下载PDF
自动气相分子吸收光谱法测定水体中高锰酸盐指数
16
作者 柯鹏振 刘雄 +3 位作者 吴雅琴 夏丽星 朱娟 康得军 《当代化工研究》 2023年第2期68-71,共4页
采用亚硝酸盐作为还原剂,以间接测定亚硝酸盐含量的方式,建立了以气相分子吸收光谱法来快速定量测定水中高锰酸盐指数的方法。试验结果表明,标准曲线相关系数大于0.9995,该方法的检出限为0.066mg/L,检出范围为0.4~5.00mg/L,相对标准偏差... 采用亚硝酸盐作为还原剂,以间接测定亚硝酸盐含量的方式,建立了以气相分子吸收光谱法来快速定量测定水中高锰酸盐指数的方法。试验结果表明,标准曲线相关系数大于0.9995,该方法的检出限为0.066mg/L,检出范围为0.4~5.00mg/L,相对标准偏差为1.56%~1.67%。此外,本文还研究了气相分子吸收光谱法与国际法采用酸式或碱式消解不同水样的试验,进一步证明该法具有准确度高、精密度高和测定速度快的特点,适合分析大批量水样、样品消解和数据分析,可实现全自动化,提高工作效率。 展开更多
关键词 气相分子吸收光谱法 高锰酸盐指数 亚硝酸盐 自动
下载PDF
气相分子吸收光谱法测定水中高锰酸盐指数 被引量:1
17
作者 冯亚君 常淼 +1 位作者 周健楠 沈秀娥 《干旱环境监测》 2023年第1期5-9,共5页
本文建立了气相分子吸收光谱法测定水中高锰酸盐指数的方法,采用绘制标准曲线来测定未知水样的高锰酸盐指数。研究表明,0~5.00 mg/L高锰酸盐指数标准曲线线性相关系数为0.995以上,测定检出限(MDL)为0.22 mg/L;分析环境标准样品,其相对... 本文建立了气相分子吸收光谱法测定水中高锰酸盐指数的方法,采用绘制标准曲线来测定未知水样的高锰酸盐指数。研究表明,0~5.00 mg/L高锰酸盐指数标准曲线线性相关系数为0.995以上,测定检出限(MDL)为0.22 mg/L;分析环境标准样品,其相对标准偏差均小于8%;用该方法测定不同浓度的标准样品和实际水样,并与国标方法(GB 11892-89)测定的结果进行F检验和t检验,结果显示2种分析方法的精密度与准确度无显著性差异。该方法在批量分析环境样品中具有一定优势。 展开更多
关键词 气相分子吸收光谱法 高锰酸盐指数 方法比对
下载PDF
气相分子吸收光谱法测定水中氨氮质量浓度不确定度评定
18
作者 吴巍 赖晓晨 +2 位作者 刘玲 李宝忠 单广波 《当代化工》 CAS 2023年第8期1947-1949,2004,共4页
建立了影响水质氨氮的数学模型,对气相分子吸收光谱法测定水质氨氮的不确定度进行了评定。结果表明:仪器性能产生的不确定度影响最大,其次是配制标准使用液引入的不确定度。对1.0029 mg·L^(-1)的水样进行测定,其合成标准不确定度为... 建立了影响水质氨氮的数学模型,对气相分子吸收光谱法测定水质氨氮的不确定度进行了评定。结果表明:仪器性能产生的不确定度影响最大,其次是配制标准使用液引入的不确定度。对1.0029 mg·L^(-1)的水样进行测定,其合成标准不确定度为0.025 mg·L^(-1),扩展不确定度为0.05 mg·L^(-1)。 展开更多
关键词 气相分子吸收光谱法 氨氮 不确定度评定
下载PDF
气相分子吸收光谱法测定地下水中氨氮
19
作者 王夏 李丹丹 陶雪梅 《环境与发展》 2023年第1期70-74,共5页
地下水样品有时含有大量泥沙,水样浑浊,且钙镁含量较高,用纳氏试剂分光光度法测定时有较大干扰。本文用气相分子吸收光谱法测定地下水中氨氮,探讨了pH、浊度、钙镁含量、亚硝酸盐浓度等对测定结果的影响。结果表明,pH值对气相分子吸收... 地下水样品有时含有大量泥沙,水样浑浊,且钙镁含量较高,用纳氏试剂分光光度法测定时有较大干扰。本文用气相分子吸收光谱法测定地下水中氨氮,探讨了pH、浊度、钙镁含量、亚硝酸盐浓度等对测定结果的影响。结果表明,pH值对气相分子吸收法测定氨氮没有影响;当样品浊度在400NUT以下时,气相分子吸收法测定氨氮无需前处理可直接进样,加标回收率104%~114%;地下水中钙、镁离子浓度在100mg/L以下,样品可以直接测定,加标回收率105%~127%;气相分子吸收法可以在线消除亚硝酸盐的干扰,地下水中亚硝酸盐含量低于2mg/L时,测量相对误差在10%以内。气相分子吸收法测定氨氮具有检出限低、精密度、准确度高等优点,相较常规方法更适用于地下水中氨氮的测定。 展开更多
关键词 气相分子吸收光谱法 地下水 氨氮
下载PDF
气相分子吸收光谱法测定大气降水中的铵离子
20
作者 毛艳 邹晓焰 +3 位作者 郎锋祥 邹武 肖莹洁 徐鹏 《化工管理》 2023年第1期64-67,共4页
文章建立了气相分子吸收光谱法测定大气降水中铵离子的方法。该方法在0.10~2.00 mg/L浓度范围内,工作曲线线性良好;方法检出限为0.009 mg/L;相对标准偏差(RSD)为1.13%~3.33%;加标回收率为94.0%~104.0%;一个批次样品(18个)的分析流程仅需... 文章建立了气相分子吸收光谱法测定大气降水中铵离子的方法。该方法在0.10~2.00 mg/L浓度范围内,工作曲线线性良好;方法检出限为0.009 mg/L;相对标准偏差(RSD)为1.13%~3.33%;加标回收率为94.0%~104.0%;一个批次样品(18个)的分析流程仅需1 h。较之现行标准方法在灵敏度、精密度、准确度和分析效率等指标方面均有改善,能够满足大气降水中铵离子的批量精准分析需求。 展开更多
关键词 大气降水 铵离子 气相分子吸收光谱法 成分分析
下载PDF
上一页 1 2 6 下一页 到第