期刊文献+
共找到6篇文章
< 1 >
每页显示 20 50 100
Determination of sterols in tobacco leaves by gas chromatography-tandem mass spectrometry
1
作者 CHEN Qiansi LIU Pingping +7 位作者 ZHAI Niu ZHENG Qingxia XU Guoyun WANG Chen FAN Kai JIN Lifeng ZHANG Hui ZHOU Huina 《烟草科技》 EI CAS CSCD 北大核心 2018年第A01期25-32,共8页
The purpose of the study was to establish an analytical method to simultaneously determine multiple sterols in tobacco leaves rapidly and accurately.In this gas chromatography-triple quadruple tandem mass spectrometry... The purpose of the study was to establish an analytical method to simultaneously determine multiple sterols in tobacco leaves rapidly and accurately.In this gas chromatography-triple quadruple tandem mass spectrometry(GC-MS/MS)based method,various conditions for sterols extraction were assessed and the instrumental operation parameters were optimized with 5α-cholane as an internal standard.Using this method,eight plant sterols,namely lanosterol,campesterol,chenodeoxycholic acid,cholesterol,β-sitosterol,stigmasterol,dihydrotachysterol and ergosterol,were separated in less than 30 min.The linear correlation coefficients were over 0.998 9,the low detection limits were in the range of 0.010 3-0.141 4 μg/g.The recoveries were from 87.30% to 115.60%,with low standard deviations.In conclusion,this method demonstrates good repeatability,accuracy,and high sensitivity,and is best suited for rapid analysis of multiple sterols in tobacco leaves. 展开更多
关键词 TOBACCO STEROL gas chromatography-triple QUADRUPOLE tandem mass spectrometry
下载PDF
The Detection of THCA Using 2-Dimensional Gas Chromatography-Tandem Mass Spectrometry in Human Fingernail Clippings: Method Validation and Comparison with Head Hair
2
作者 Joseph Jones Mary Jones +1 位作者 Charles Plate Douglas Lewis 《American Journal of Analytical Chemistry》 2013年第10期1-8,共8页
Marijuana use as well as abuse is a significant public health and public safety concern in the United States and using hair to identify marijuana users and abusers has been gaining acceptance in a number of venues inc... Marijuana use as well as abuse is a significant public health and public safety concern in the United States and using hair to identify marijuana users and abusers has been gaining acceptance in a number of venues including workplace, court ordered, and substance abuse treatment monitoring. After the presentation of a fully validated 2-dimensional gas chromatography-tandem mass spectrometry method for the detection of 11-nor-9-carboxy-Δ9-tetrahydrocannabinol (THCA), the chief metabolite of the main psychoactive compound in marijuana, Δ9-tetrahydrocannabinol (THC), we evaluated the usefulness of fingernail clippings as an alternative specimen type to hair by the analysis of a set of 60 matched pairs of head hair and fingernail clippings. The limit of detection was 10 fg/mg, the limit of quantitation was 20 fg/mg, and the assay was linear from 20 fg/mg to 500 fg/mg. The intra- and inter-assay imprecision and bias studies at 4 different concentrations (50, 100, 500, and 1000 fg/mg) were acceptable where all % Target observations were within 16% of their expected concentrations and all %CV calculations were less than 13.5%. THCA was detectable in more fingernail specimens (53.3%) than hair specimens (46.7%) and the mean concentrations in nails were on average 4.9 times higher than in hair (1813 fg/mg and 364 fg/mg, respectively). The THCA concentrations in hair and nail were strongly associated (r = 0.974, P < 0.01, n = 60) and the association was significant. The study demonstrated that fingernail clippings are a suitable alternative specimen type to hair to monitor for marijuana use and abuse. 展开更多
关键词 11-Nor-9-Carboxy-Δ9-Tetrahydrocannabinol THCA Carboxy-THC HAIR Fingernail 2D-GC-MS/MS 2-Dimensional gas Chromatography tandem mass spectrometry
下载PDF
Determination of 8 Diuretics and Probenecid in Human Urine by Gas Chromatography-Mass Spectrometry: Confirmation Procedure 被引量:2
3
作者 Olga Zaporozhets Iuna Tsyrulneva Mykola Ischenko 《American Journal of Analytical Chemistry》 2012年第4期320-327,共8页
A fast and sensitive method for determination of 8 diuretics (acetazolamide, bendroflumethiazide, bumetanide, chlorthalidone, furosemide, hydrochlorothiazide, metolazone, triamterene) and masking agent (probenecid) in... A fast and sensitive method for determination of 8 diuretics (acetazolamide, bendroflumethiazide, bumetanide, chlorthalidone, furosemide, hydrochlorothiazide, metolazone, triamterene) and masking agent (probenecid) in human urine using gas-chromatography with mass spectrometric detection is described. The extraction of the substances as function of the nature of organic solvent, mixing time and pH of aqueous phase was studied. The tandem mass spectrometry was used to increase selectivity of diuretics determination due to elimination of background interferences. Fragmentation reactions were studied for each compound and their collision energies were optimized to obtain the best selectivity. The results of method’s validation demonstrate its suitability in routine analysis for confirmation purposes. 展开更多
关键词 DIURETICS URINE gas CHROMATOGRAPHY tandem mass spectrometry CONFIRMATION
下载PDF
liver and the defects of cholesterol and bile acids biosynthesis: rare disorders many diagnostic pitfalls 被引量:2
4
作者 Gaetano Corso Antonio Dello Russo Monica Gelzo 《World Journal of Gastroenterology》 SCIE CAS 2017年第29期5257-5265,共9页
In recent decades, biotechnology produced a growth of knowledge on the causes and mechanisms of metabolic diseases that have formed the basis for their study, diagnosis and treatment. Unfortunately, it is well known t... In recent decades, biotechnology produced a growth of knowledge on the causes and mechanisms of metabolic diseases that have formed the basis for their study, diagnosis and treatment. Unfortunately, it is well known that the clinical features of metabolic diseases can manifest themselves with very different characteristics and escape early detection. Also, it is well known that the prognosis of many metabolic diseases is excellent if diagnosed and treated early. In this editorial we briefly summarized two groups of inherited metabolic diseases, the defects of cholesterol biosynthesis and those of bile acids. Both groups show variable clinical manifestations but some clinical signs and symptoms are common in both the defects of cholesterol and bile acids. The differential diagnosis can be made analyzing sterol profiles in blood and/or bile acids in blood and urine by chromatographic techniques(GC-MS and LC-MS/MS). Several defects of both biosynthetic pathways are treatable so early diagnosis is crucial. Unfortunately their diagnosis is made too late, due either to the clinical heterogeneity of the syndromes(severe, mild and very mild) that to the scarcity of scientific dissemination of these rare diseases. Therefore, the delay in diagnosis leads the patient to the medical observation when the disease has produced irreversible damages to the body. Here, we highlighted simple clinical and laboratory descriptions that can potentially make you to suspect a defect in cholesterol biosynthesis and/or bile acids, as well, we suggest appropriate request of the laboratory tests that along with common clinical features can help to diagnose these defects. 展开更多
关键词 CHOLESTEROL Bile acids Liver metabolism gas chromatography coupled to mass spectrometry Liquid chromatography coupled to tandem mass spectrometry
下载PDF
A New Automated Method and Sample Data Flow for Analysis of Volatile Nitrosamines in Human Urine 被引量:1
5
作者 James A. Hodgson Tiffany H. Seyler +2 位作者 Ernest McGahee Stephen Arnstein Lanqing Wang 《American Journal of Analytical Chemistry》 2016年第2期165-178,共14页
Volatile nitrosamines (VNAs) are a group of compounds classified as probable (group 2A) and possible (group 2B) carcinogens in humans. Along with certain foods and contaminated drinking water, VNAs are detected at hig... Volatile nitrosamines (VNAs) are a group of compounds classified as probable (group 2A) and possible (group 2B) carcinogens in humans. Along with certain foods and contaminated drinking water, VNAs are detected at high levels in tobacco products and in both mainstream and side-stream smoke. Our laboratory monitors six urinary VNAs—N-nitrosodimethylamine (NDMA), N-nitrosomethylethylamine (NMEA), N-nitrosodiethylamine (NDEA), N-nitrosopiperidine (NPIP), N-nitrosopyrrolidine (NPYR), and N-nitrosomorpholine (NMOR)—using isotope dilution GC-MS/ MS (QQQ) for large population studies such as the National Health and Nutrition Examination Survey (NHANES). In this paper, we report for the first time a new automated sample preparation method to more efficiently quantitate these VNAs. Automation is done using Hamilton STAR<sup>TM</sup> and Caliper Staccato<sup>TM</sup> workstations. This new automated method reduces sample preparation time from 4 hours to 2.5 hours while maintaining precision (inter-run CV < 10%) and accuracy (85% - 111%). More importantly this method increases sample throughput while maintaining a low limit of detection (<10 pg/mL) for all analytes. A streamlined sample data flow was created in parallel to the automated method, in which samples can be tracked from receiving to final LIMs output with minimal human intervention, further minimizing human error in the sample preparation process. This new automated method and the sample data flow are currently applied in bio-monitoring of VNAs in the US non-institutionalized population NHANES 2013-2014 cycle. 展开更多
关键词 Volatile Nitrosamines AUTOMATION Sample Data Flow gas Chromatography tandem mass spectrometry
下载PDF
Simultaneous measurement of 16 bisphenol A analogues in house dust and evaluation of two sampling techniques 被引量:2
6
作者 Xinghua Fan Guru Prasad Katuri +2 位作者 Amelia Anne Caza Pat E.Rasmussen Cariton Kubwabo 《Emerging Contaminants》 2021年第1期1-9,共9页
Bisphenol A(BPA)is a high production volume(HPV)chemical used to make polycarbonate(PC)plastics and epoxy resins.Due to its potential adverse health effects,BPA has been restricted or banned in some products and thus ... Bisphenol A(BPA)is a high production volume(HPV)chemical used to make polycarbonate(PC)plastics and epoxy resins.Due to its potential adverse health effects,BPA has been restricted or banned in some products and thus many alternatives to BPA have been introduced into the market.Most of these alternatives such as bisphenol S(BPS),bisphenol F(BPF),and bisphenol M(BPM),have similar chemical structures to BPA and termed as BPA analogues(BPAAs).In this study,a method was developed for the simultaneous determination of 16 BPAAs in indoor dust by gas chromatography coupled with tandem mass spectrometry(GC-MS/MS).The method was sensitive,with method detection limits(MDLs)ranging from 0.001 mg/g to 0.017 mg/g.The method demonstrated good recoveries(>80%)for the majority of the target compounds and was applied to the analysis of dust samples collected from 2007 to 2010 in 13 cities across Canada under the Canadian House Dust Study(CHDS).Samples were collected using two different techniques:household vacuum dust samples collected from household vacuum bags(HD);fresh vacuum dust(FD)samples collected by a trained technician from dry floor surfaces.In addition to BPA with 100%detection in 119 HD samples,BPS,BPF,and BPM were detected with high detection frequencies(>75%)with median(range)concentrations of 0.242(<0.017-35.1)mg/g,0.123(<0.007-2.67)mg/g,and 0.028(<0.005-0.908)mg/g,respectively,suggesting their wide use in various applications.Other BPAAs were not detected or detected with very low frequencies and at low levels.This study shows that BPAA concentrations in dust sampled from household vacuum bags compare well with concentrations observed in fresh dust collected from the same homes,suggesting that HD sampling could be a cost-effective alternative to FD sampling.The method was also applied to the analysis of a standard reference material e NIST SRM 2585(organic contaminants in house dust).So far there are no certified values for BPAAs in SRM 2585.In this study only three BPAAs were detected in SRM 2585,with mean values of 34.2(±2.3)mg/g for BPA,1.88(±0.22)mg/g for BPS,and 0.297(±0.052)mg/g for BPF. 展开更多
关键词 Bisphenol analogues Dust sampling gas chromatography tandem mass spectrometry Standard reference material
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部