期刊文献+
共找到8,843篇文章
< 1 2 250 >
每页显示 20 50 100
High Efficiency Landfill Gas Fired Power Plant Process with ORC
1
作者 Petri Kouvo 《Journal of Earth Science and Engineering》 2016年第5期254-263,共10页
Helsinki Environmental Services Authority HSY ,Ammaissuo waste management centre consists of two landfill sites. The old land filling area was established in 1987 and closed in 2007. The landfilling at the new landfil... Helsinki Environmental Services Authority HSY ,Ammaissuo waste management centre consists of two landfill sites. The old land filling area was established in 1987 and closed in 2007. The landfilling at the new landfill section started in November 2007. Until spring 2014 the main treatment method for source separated MSW (municipal solid'waste) collected from Helsinki Metropolitan area households was landfilling. Approximately 250,000 tonnes of MSW was landfilled annually. From April 2014 on all of the MWS has been utilized in heat and electricity production at new Waste to Energy plant owned and operated by energy company Vantaa Energy Ltd. The landscaping of the landfills is currently ongoing. The construction of the landfill gas collection system was started in 1994 and from 1996 on landfill gas from old landfill area was recovered and burned in torches to reduce the greenhouse gas effect caused by methane in landfill gas. In the end of year (2004) new landfill gas utilisation system was taken in use Gas was used as a fuel in HOB (heat only boiler) to generate district heating for nearby community as well as commercial and industrial sites. The capacity of the system was 7,000 Nm3/h that corresponded to app. 30 MW of heat. Since district heat was mainly needed only during the cold season of the year only about half of the landfill gas produced by the landfill was able to utilize and rest of the gas was still flared leading to relatively low utilization rate of the gas. The construction work of the new 15 MW + 1.2 MW electricity power plant started in spring 2009. The power plant consists of four gas engines and generators and organic rankine cycle process utilizing thermal oil for heat transfer from exhaust gas and steam turbine with hexamethyldisiloxane (silicone oil) as a medium agent. The ORC (Organic Rankine Cycle)-process was commissioned in August 2011 and the operational experiences have been very good. Based on current knowledge the HSY power plant is the biggest landfill gas fired power plant in Europe and probably even in the whole world. Also the combined engine and ORC-process is unique for landfill gas power plants. The third phase of the biogas utilization took place in summer 2015 when the anaerobic digestion biowaste treatment plant was introduced. At the moment the product gas from digestion plant is utilized at landfill gas power plant. In the future gas will be used as a fuel for new power plant process consisting two gas engines and ORC process. Commissioning of the new power plant will take place in October 2016. This paper presents detailed description of the landfill gas utilization system of HSY waste treatment centre and information on operational experiences of landfill gas fired power plant process. 展开更多
关键词 Landfill gas power production ORC-process waste management BIOWASTE anaerobic digestion.
下载PDF
Implementation Measures for Fire Work Safety in Gas Area of Metallurgical Enterprises
2
作者 Meiting Niu Kaiu Zhan 《Frontiers of Metallurgical Industry》 2024年第1期37-39,共3页
It is an important task to control the dangerous operation of gas fire and reduce the occurrence of gas fire and explosion accidents in ensuring gas operation safety in metallurgical enterprises.Combined with the requ... It is an important task to control the dangerous operation of gas fire and reduce the occurrence of gas fire and explosion accidents in ensuring gas operation safety in metallurgical enterprises.Combined with the require-ments of current laws,standards and practical experience,the key points in fire safety management and control are analyzed to solve the gas fire safety problems. 展开更多
关键词 gas fire operation SAFETY COUNTERMEASURES
下载PDF
Mutual regulation of microglia and astrocytes after Gas6 inhibits spinal cord injury
3
作者 Jiewen Chen Xiaolin Zeng +6 位作者 Le Wang Wenwu Zhang Gang Li Xing Cheng Peiqiang Su Yong Wan Xiang Li 《Neural Regeneration Research》 SCIE CAS 2025年第2期557-573,共17页
Invasive inflammation and excessive scar formation are the main reasons for the difficulty in repairing nervous tissue after spinal cord injury.Microglia and astrocytes play key roles in the spinal cord injury micro-e... Invasive inflammation and excessive scar formation are the main reasons for the difficulty in repairing nervous tissue after spinal cord injury.Microglia and astrocytes play key roles in the spinal cord injury micro-environment and share a close interaction.However,the mechanisms involved remain unclear.In this study,we found that after spinal cord injury,resting microglia(M0)were polarized into pro-inflammatory phenotypes(MG1 and MG3),while resting astrocytes were polarized into reactive and scar-forming phenotypes.The expression of growth arrest-specific 6(Gas6)and its receptor Axl were significantly down-regulated in microglia and astrocytes after spinal cord injury.In vitro experiments showed that Gas6 had negative effects on the polarization of reactive astrocytes and pro-inflammatory microglia,and even inhibited the cross-regulation between them.We further demonstrated that Gas6 can inhibit the polarization of reactive astrocytes by suppressing the activation of the Yes-associated protein signaling pathway.This,in turn,inhibited the polarization of pro-inflammatory microglia by suppressing the activation of the nuclear factor-κB/p65 and Janus kinase/signal transducer and activator of transcription signaling pathways.In vivo experiments showed that Gas6 inhibited the polarization of pro-inflammatory microglia and reactive astrocytes in the injured spinal cord,thereby promoting tissue repair and motor function recovery.Overall,Gas6 may play a role in the treatment of spinal cord injury.It can inhibit the inflammatory pathway of microglia and polarization of astrocytes,attenuate the interaction between microglia and astrocytes in the inflammatory microenvironment,and thereby alleviate local inflammation and reduce scar formation in the spinal cord. 展开更多
关键词 ASTROCYTES AXL cell polarization gas6 Hippo signal inflammatory micro-environment intercellular interaction MICROGLIA single-cell sequencing spinal cord injury
下载PDF
RESEARCH ON THE DEVELOPMENT OF GAS-FIRED POWER GENERATION IN CHINA FOR YEAR 2001~2010
4
作者 吴敬儒 虞见思 +1 位作者 胡肄篯 郑君衡 《Electricity》 2002年第2期25-32,共8页
Through a great many qualitative and quantitative analyses, this paperstudies the development of gas power in China in the coming ten years based oninvestigations of more than one year. Some good advices are suggested... Through a great many qualitative and quantitative analyses, this paperstudies the development of gas power in China in the coming ten years based oninvestigations of more than one year. Some good advices are suggested toinvestors and decision-makers, such as the advantages and disadvantages ofpower generation using natural gas, development plans of local power grids, andproblems necessary to be noted and solved.[ 展开更多
关键词 natural gas power generation FORECAST RESEARCH
下载PDF
Model Selection of Gas Turbine for Large Scale Gas-Fired Combined Cycle Power Plant
5
作者 何语平 《Electricity》 2003年第4期36-39,共4页
This paper briefs the configuration and performance of large size gas turbines and their composed combined cycle power plants designed and produced by four large renown gas turbine manufacturing firms in the world, pr... This paper briefs the configuration and performance of large size gas turbines and their composed combined cycle power plants designed and produced by four large renown gas turbine manufacturing firms in the world, providing reference for the relevant sectors and enterprises in importing advanced gas turbines and technologies. 展开更多
关键词 natural gas combined cycle power plant unit model selection
下载PDF
A novel carbon trap sampling system for coal-fired flue gas mercury measurement
6
作者 汤红健 段钰锋 +3 位作者 朱纯 周强 佘敏 蔡亮 《Journal of Southeast University(English Edition)》 EI CAS 2015年第2期244-248,共5页
A novel carbon trap sampling system for gas-phase mercury measurement in flue gas is developed, including the high efficient sorbents made of modified biomass cokes and high precision sorbent traps for measuring parti... A novel carbon trap sampling system for gas-phase mercury measurement in flue gas is developed, including the high efficient sorbents made of modified biomass cokes and high precision sorbent traps for measuring particle-bound and total vapor-phase mercury in flue gas. A dedusting device is installed to collect fine fly ash for reducing the measurement errors. The thorough comparison test of mercury concentration in flue gas is conducted between the novel sampling system and the Ontario hydro method (OHM) in a 6 kW circulating fluidized bed combustor. Mercury mass balance rates of the OHM range from 95.47% to 104.72%. The mercury breakthrough rates for the second section of the sorbent trap are all below 2%. The relative deviations in the two test cases are in the range of 15. 96% to 17. 56% under different conditions. The verified data suggest that this novel carbon trap sampling system can meet the standards of quality assurance and quality control required by EPA Method 30B and can be applied to the coal-fired flue gas mercury sampling system. 展开更多
关键词 mercury sorbent trap coal-fired flue gas mercury sampling unit
下载PDF
Practice of Fighting Fire and Suppressing Explosion for a Super-Large and Highly Gassy Mine 被引量:20
7
作者 ZHOU Fu-bao WANG De-ming +2 位作者 ZHANG Yong-jiu ZHANG Yu-liang LI Xiang 《Journal of China University of Mining and Technology》 EI 2007年第4期459-463,共5页
The Baijigou Mine fire in Ningxia Province,which broke out on October 24,2003,affected more than 108 m3 of the mine and was probably the largest underground fire in China in recent years. In addition to its size,the f... The Baijigou Mine fire in Ningxia Province,which broke out on October 24,2003,affected more than 108 m3 of the mine and was probably the largest underground fire in China in recent years. In addition to its size,the fire was also characterized by excessive air leakage and the potential for violent methane explosions. A series of new measures were taken to fight the fire,including sealing intake tunnels with water,injecting three-phase foam through boreholes,and flushing with a large volume of nitrogen. The fire was successfully extinguished and production re-sumed soon afterwards; not one single methane explosion occurred during fire-fighting and afterwards. 展开更多
关键词 mine fire gas explosion fire-FIGHTING explosion-suppression three-phase foam
下载PDF
Application of a novel detection approach based on non-dispersive infrared theory to the in-situ analysis on indicator gases from underground coal fire 被引量:9
8
作者 TIAN Fu-chao LIANG Yun-tao +2 位作者 ZHU Hong-qing CHEN Ming-yi WANG Jin-cheng 《Journal of Central South University》 SCIE EI CAS CSCD 2022年第6期1840-1855,共16页
Coal mine fires,which can cause heavy casualties,environmental damages and a waste of coal resources,have become a worldwide problem.Aiming at overcoming the drawbacks,such as a low analysis efficiency,poor stability ... Coal mine fires,which can cause heavy casualties,environmental damages and a waste of coal resources,have become a worldwide problem.Aiming at overcoming the drawbacks,such as a low analysis efficiency,poor stability and large monitoring error,of the existing underground coal fire monitoring technology,a novel monitoring system based on non-dispersive infrared(NDIR)spectroscopy is developed.In this study,first,the measurement principle of NDIR sensor,the gas concentration calculation and its temperature compensation algorithms were expounded.Next,taking CO and CH_(4) as examples,the liner correlation coefficients of absorbance and the temperature correction factors of the two indicator gases were calculated,and then the errors of concentration measurement for CO,CO_(2),CH_(4) and C_(2)H_(4) were further analyzed.The results disclose that the designed NDIR sensors can satisfy the requirements of industrial standards for monitoring the indicator gases for coal fire hazards.For the established NDIR-based monitoring system,the NDIRbased spectrum analyzer and its auxiliary equipment boast intrinsically safe and explosion-proof performances and can achieve real-time and in-situ detection of indicator gases when installed close to the coal fire risk area underground.Furthermore,a field application of the NDIR-based monitoring system in a coal mine shows that the NDIR-based spectrum analyzer has a permissible difference from the chromatography in measuring the concentrations of various indicator gases.Besides,the advantages of high accuracy,quick analysis and excellent security of the NDIR-based monitoring system have promoted its application in many coal mines. 展开更多
关键词 indicator gas coal spontaneous combustion infrared spectrometry bundle tube monitoring intrinsically safe
下载PDF
Experimental study on mercury content in flue gas of coal-fired units based on laser-induced breakdown spectroscopy 被引量:3
9
作者 Kai RONG Zhenzhen WANG +4 位作者 Ruomu HU Renwei LIU Yoshihiro DEGUCH Junjie YAN Jiping LIU 《Plasma Science and Technology》 SCIE EI CAS CSCD 2020年第7期75-82,共8页
Accurate measurement of trace heavy metal mercury(Hg) in flue gas of coal-fired units is great significance for ecological and environmental protection.Mixed gas was used to simulate the actual flue gas of a power pla... Accurate measurement of trace heavy metal mercury(Hg) in flue gas of coal-fired units is great significance for ecological and environmental protection.Mixed gas was used to simulate the actual flue gas of a power plant in this study.A laser-induced breakdown spectroscopy(LIBS)system for Hg measurement in mixed gas was built to study the effect of mixed gas pressure,Hg concentration in mixed gas and delay time on Hg measurement.The experimental results show that the appropriate low mixed gas pressure can obtain high Hg signal intensity and signal to noise ratio.The Hg signal intensity and signal to noise ratio increased with the increase of Hg concentration in mixed gas.The Hg signal intensity and signal to noise ratio decreased with the increase in delay time.According to the above results,the optimized measurement conditions can be determined.Different Hg concentrations in mixed gas were quantitatively analyzed by the internal standard method and traditional calibration method respectively.The relative error of prediction of the test sample obtained by the internal standard method was within 11.11%.The relative error of prediction of the traditional calibration method was less than 14.54%.This proved that the internal standard method can improve the accuracy of quantitative analysis of Hg concentration in flue gas using LIBS. 展开更多
关键词 laser-induced breakdown spectroscopy flue gas trace heavy metal quantitative analysis
下载PDF
The Model of Thermal Response of Liquefied Petroleum Gas Tanks Partially Exposed to Jet Fire 被引量:2
10
作者 邢志祥 蒋军成 赵晓芳 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2004年第5期639-646,共8页
This paper describes a mathematical model developed to study the behavior of liquefied petroleum gas (LPG) tanks when subjected to jet fire. The model consists of a number of field and zone sub-models which are used t... This paper describes a mathematical model developed to study the behavior of liquefied petroleum gas (LPG) tanks when subjected to jet fire. The model consists of a number of field and zone sub-models which are used to simulate the various physical phenomena taking place during the tank engulfment period. The model can be used to predict the pressure and temperature of the LPG in the tank, the temperature of the wall of tank, and the time of tank explosion. The comparisons between the model predicted results and the test data show good agreement. The results show that the jet fire partially impinging on tank wall led to higher wall temperature and the time to failure was shorter than that in engulfing pool fire. And the exposure of the upper wall in the vapor zone to the fire is more dangerous than that of the LPG contacted wall. 展开更多
关键词 mass transfer heat transfer thermal response liquefied petroleum gas TANK jet fire simulation
下载PDF
GAS6-AS1调节miR-370-3p/SPATA2轴对卵巢癌细胞增殖、迁移、侵袭、凋亡和EMT的影响 被引量:1
11
作者 贾奕娟 王中显 +1 位作者 王冬花 龚世雄 《现代肿瘤医学》 CAS 2024年第3期424-431,共8页
目的:探讨长链非编码RNA GAS6反义RNA1(long non-coding RNA GAS6 antisense RNA1, lncRNA GAS6-AS1)调节miR-370-3p/精子发生相关蛋白2 (spermatogenesis-associated protein 2, SPATA2)轴对卵巢癌细胞增殖、迁移、侵袭、凋亡和上皮间... 目的:探讨长链非编码RNA GAS6反义RNA1(long non-coding RNA GAS6 antisense RNA1, lncRNA GAS6-AS1)调节miR-370-3p/精子发生相关蛋白2 (spermatogenesis-associated protein 2, SPATA2)轴对卵巢癌细胞增殖、迁移、侵袭、凋亡和上皮间质转化(epithelial mesenchymal transformation, EMT)的影响。方法:qRT-PCR、Western blot分别检测癌旁组织、卵巢癌组织、人正常卵巢上皮细胞IOSE80及卵巢癌细胞系HO-8910、SKOV3、A2780中GAS6-AS1、miR-370-3p及SPATA2蛋白表达。将SKOV3细胞分为:对照组(NC组)、 si-NC组、si-GAS6-AS1组、mimic NC组、miR-370-3p mimic组、si-GAS6-AS1+inhibitor NC组、si-GAS6-AS1+miR-370-3p inhibitor组,qRT-PCR检测细胞中GAS6-AS1、miR-370-3p表达;CCK-8法检测细胞增殖;流式细胞术检测细胞凋亡;划痕愈合实验检测细胞迁移;Transwell实验检测细胞侵袭;Western blot检测SPATA2、细胞周期素D1(CyclinD1)、Bcl-2相关X蛋白(Bcl-2-associated X,Bax)、E-钙黏蛋白(E-cadherin)、波形蛋白(Vimentin)、神经钙黏蛋白(N-cadherin)表达;双荧光素酶报告基因实验检测GAS6-AS1与miR-370-3p、 miR-370-3p与SPATA2的关系。结果:在卵巢癌组织和细胞中GAS6-AS1、SPATA2蛋白高表达,miR-370-3p低表达,且在SKOV3细胞中GAS6-AS1、SPATA2蛋白表达量最高,miR-370-3p表达水平最低,因此,选择SKOV3细胞为后续研究对象。与NC组、si-NC组比较,si-GAS6-AS1组GAS6-AS1、OD450值(24 h、48 h、72 h)、划痕愈合率、侵袭细胞数、SPATA2、CyclinD1、Vimentin、N-cadherin蛋白表达降低,miR-370-3p表达、细胞凋亡率、Bax、E-cadherin蛋白表达升高(P<0.05);与NC组、mimic NC组比较,miR-370-3p mimic组OD450值(24 h、48 h、72 h)、划痕愈合率、侵袭细胞数、SPATA2、CyclinD1、Vimentin、N-cadherin蛋白表达降低,miR-370-3p表达、细胞凋亡率、Bax、E-cadherin蛋白表达升高(P<0.05);miR-370-3p inhibitor减弱了沉默GAS6-AS1对SKOV3细胞增殖、迁移、侵袭及EMT的抑制及对细胞凋亡的促进作用。GAS6-AS1与miR-370-3p、miR-370-3p与SPATA2存在靶向调控关系。结论:沉默GAS6-AS1通过上调miR-370-3p来抑制SPATA2表达,从而抑制SKOV3细胞增殖、迁移、侵袭及EMT,并促进细胞凋亡。 展开更多
关键词 长链非编码RNA gas6反义RNA1 miR-370-3p 精子发生相关蛋白2 卵巢癌 上皮间质转化
下载PDF
Wet flue gas desulfurization performance of 330 MW coal-fired power unit based on computational fluid dynamics region identification of flow pattern and transfer process 被引量:1
12
作者 Jiangyuan Qu Nana Qi +2 位作者 Kai Zhang Lifeng Li PengchengWang 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2021年第1期13-26,共14页
Wet Flue Gas Desulfurization(WFGD)unit based upon spray scrubber has beenwidely employed to control SO_(2) emissions from flue gas in coal-fired power plant.To clarify the dependence of desulfurization performance on ... Wet Flue Gas Desulfurization(WFGD)unit based upon spray scrubber has beenwidely employed to control SO_(2) emissions from flue gas in coal-fired power plant.To clarify the dependence of desulfurization performance on inter-phase transfer behaviors with non-ideal contacting patterns of flue gas and slurry droplets,three regions in spray scrubber are distinguished in terms of gas-slurry flow structures using CFD method in the Eulerian-Lagrangian framework.A comprehensive model is established by involving the transfer process between two phases and chemical reactions in aqueous phase,which is validatedwith the measured data froma WFGD scrubber of 330 MW coal-fired power unit.Numerical results show that the overall uniformity degree of flue gas in whole scrubber is largely determined by the force-balanced droplets in the middle part of scrubber,which is dominated by counter-current mode.Both momentum transfer behavior and SO_(2) chemical absorption process present the synchronicity with the evolution of gas-slurry flow pattern,whilst the heat transfer together with H_(2)O evaporation has little effect on overall absorption process.Three regions are firstly defined as Gas Inlet Region(GIR),Dominant Absorption Region(DAR)and Slurry Dispersed Region(SDR)from the bottom to top of scrubber.SO_(2) is mainly scrubbed in DAR,which provides much more intensive interaction between two phases compared to GIR or SDR.A better understanding of the desulfurization process is obtained from the fundamental relationship between transport phenomena and chemical reactions based upon the complicated hydrodynamics of gas-slurry two-phase flow,which should be useful for designing and optimizing the scrubber in coal-fired power unit. 展开更多
关键词 Wet flue gas desulfurization gas-liquid flow Eulerian-Lagrangian model Flow pattern Transport processes ABSORPTION
下载PDF
Fault Tree Analysis of Fire and Explosion Accidents for Dual Fuel (Diesel/Natural Gas) Ship Engine Rooms 被引量:1
13
作者 Yifeng Guan Jie Zhao +1 位作者 Tengfei Shi Peipei Zhu 《Journal of Marine Science and Application》 CSCD 2016年第3期331-335,共5页
In recent years, China's increased interest in environmental protection has led to a promotion of energy-efficient dual fuel(diesel/natural gas) ships in Chinese inland rivers. A natural gas as ship fuel may pose ... In recent years, China's increased interest in environmental protection has led to a promotion of energy-efficient dual fuel(diesel/natural gas) ships in Chinese inland rivers. A natural gas as ship fuel may pose dangers of fire and explosion if a gas leak occurs. If explosions or fires occur in the engine rooms of a ship, heavy damage and losses will be incurred. In this paper, a fault tree model is presented that considers both fires and explosions in a dual fuel ship; in this model, dual fuel engine rooms are the top events. All the basic events along with the minimum cut sets are obtained through the analysis.The primary factors that affect accidents involving fires and explosions are determined by calculating the degree of structure importance of the basic events.According to these results, corresponding measures are proposed to ensure and improve the safety and reliability of Chinese inland dual fuel ships. 展开更多
关键词 dual fuel ship engine room fault tree fire and explosion safety measures gas leak
下载PDF
Application of Supercritical CO2 Gas Turbine for the Fossil Fired Thermal Plant 被引量:13
14
作者 Y.Muto S. Ishiyama +2 位作者 Y. Kato T. Ishizuka M. Aritomi 《Journal of Energy and Power Engineering》 2010年第9期7-15,共9页
A supercritical CO2 gas turbine cycle can produce power at high efficiency and the gas turbine is compact compared with the steam turbine. Therefore, it is very advantageous power cycle for the medium temperature rang... A supercritical CO2 gas turbine cycle can produce power at high efficiency and the gas turbine is compact compared with the steam turbine. Therefore, it is very advantageous power cycle for the medium temperature range less than 650 ℃. The purpose of this paper is to show how it can be effectively applied not only to the nuclear power but also to the fossil fired power plant. A design of 300 MWe plant has been carried out, where thermal energy of flue gas leaving a CO2 heater is utilized effectively by means of economizer and a high cycle thermal efficiency of 43.4 % has been achieved. Since the temperature and the pressure difference of the CO2 heater are very high, the structural design becomes very difficult. It is revealed that this problem can be effectively solved by introducing a double expansion turbine cycle. The component designs of the CO2 heater, the economizer, supercritical CO2 turbines, compressors and the recuperators are given and it is shown that these components have good performances and compact sizes. 展开更多
关键词 Supercritical CO2 cycle gas turbine heat exchanger thermal power plant thermal efficiency PCHE CO2 heater
下载PDF
Geochemistry and origins of hydrogen-containing natural gases in deep Songliao Basin,China:Insights from continental scientific drilling 被引量:3
15
作者 Shuang-Biao Han Chao-Han Xiang +3 位作者 Xin Du Lin-Feng Xie Jie Huang Cheng-Shan Wang 《Petroleum Science》 SCIE EI CAS CSCD 2024年第2期741-751,共11页
The different reservoirs in deep Songliao Basin have non-homogeneous lithologies and include multiple layers with a high content of hydrogen gas.The gas composition and stable isotope characteristics vary significantl... The different reservoirs in deep Songliao Basin have non-homogeneous lithologies and include multiple layers with a high content of hydrogen gas.The gas composition and stable isotope characteristics vary significantly,but the origin analysis of different gas types has previously been weak.Based on the geochemical parameters of gas samples from different depths and the analysis of geological settings,this research covers the diverse origins of natural gas in different strata.The gas components are mainly methane with a small amount of C_(2+),and non-hydrocarbon gases,including nitrogen(N_(2)),hydrogen(H_(2)),carbon dioxide(CO_(2)),and helium(He).At greater depth,the carbon isotope of methane becomes heavier,and the hydrogen isotope points to a lacustrine sedimentary environment.With increasing depth,the origins of N_(2)and CO_(2)change gradually from a mixture of organic and inorganic to inorganic.The origins of hydrogen gas are complex and include organic sources,water radiolysis,water-rock(Fe^(2+)-containing minerals)reactions,and mantle-derived.The shales of Denglouku and Shahezi Formations,as source rocks,provide the premise for generation and occurrence of organic gas.Furthermore,the deep faults and fluid activities in Basement Formation control the generation and migration of mantle-derived gas.The discovery of a high content of H_(2)in study area not only reveals the organic and inorganic association of natural-gas generation,but also provides a scientific basis for the exploration of deep hydrogen-rich gas. 展开更多
关键词 gas compositions Stable isotopes gas origins Hydrogen gas Songliao Basin
下载PDF
Constraints on Characteristics and Distribution of Gas Hydrate and Free Gas Using Broad-Band Processing of Three-Dimensional Seismic Data 被引量:2
16
作者 WANG Xiujuan ZHOU Jilin +7 位作者 LI Sanzhong LI Lixia LI Jie LI Yuanping WANG Linfei SU Pibo JIN Jiapeng GONG Zhi 《Journal of Ocean University of China》 SCIE CAS CSCD 2024年第5期1233-1247,共15页
Gas hydrate drilling expeditions in the Pearl River Mouth Basin,South China Sea,have identified concentrated gas hydrates with variable thickness.Moreover,free gas and the coexistence of gas hydrate and free gas have ... Gas hydrate drilling expeditions in the Pearl River Mouth Basin,South China Sea,have identified concentrated gas hydrates with variable thickness.Moreover,free gas and the coexistence of gas hydrate and free gas have been confirmed by logging,coring,and production tests in the foraminifera-rich silty sediments with complex bottom-simulating reflectors(BSRs).The broad-band processing is conducted on conventional three-dimensional(3D)seismic data to improve the image and detection accuracy of gas hydratebearing layers and delineate the saturation and thickness of gas hydrate-and free gas-bearing sediments.Several geophysical attributes extracted along the base of the gas hydrate stability zone are used to demonstrate the variable distribution and the controlling factors for the differential enrichment of gas hydrate.The inverted gas hydrate saturation at the production zone is over 40% with a thickness of 90 m,showing the interbedded distribution with different boundaries between gas hydrate-and free gas-bearing layers.However,the gas hydrate saturation value at the adjacent canyon is 70%,with 30-m-thick patches and linear features.The lithological and fault controls on gas hydrate and free gas distributions are demonstrated by tracing each gas hydrate-bearing layer.Moreover,the BSR depths based on broad-band reprocessed 3D seismic data not only exhibit variations due to small-scale topographic changes caused by seafloor sedimentation and erosion but also show the upward shift of BSR and the blocky distribution of the coexistence of gas hydrate and free gas in the Pearl River Mouth Basin. 展开更多
关键词 gas hydrate free gas shift of BSR broad-band processing
下载PDF
基于GAS算法的卵砾石粒径自动识别应用研究
17
作者 蔡豫豪 高仕赵 +1 位作者 张丛林 董晓明 《泥沙研究》 CAS CSCD 北大核心 2024年第2期9-16,共8页
粒径和级配是表征床面组成的重要指标,基于GAS粒径自动识别技术可自动识别粗粒床面粒径并生成级配曲线,能够大幅提高现场采样和分析的效率。为了验证GAS的分割效果,采用GAS提供的默认参数进行分割,同时应用ImageJ软件手动分割进行验证... 粒径和级配是表征床面组成的重要指标,基于GAS粒径自动识别技术可自动识别粗粒床面粒径并生成级配曲线,能够大幅提高现场采样和分析的效率。为了验证GAS的分割效果,采用GAS提供的默认参数进行分割,同时应用ImageJ软件手动分割进行验证。结果表明:GAS级配曲线的相对误差为5.7%,相关系数为0.992。另外,采用单参数和多参数敏感性分析法来标准化参数调整方案,gre、can1和can2对GAS提取的级配曲线和特征粒径有显著影响,其中gre起主导作用,而can1和can2控制着砾石边界的检测完整性。 展开更多
关键词 粗粒床面 级配曲线 gas算法 数字筛分 图像处理
下载PDF
Deep-large faults controlling on the distribution of the venting gas hydrate system in the middle of the Qiongdongnan Basin, South China Sea 被引量:2
18
作者 Jin-feng Ren Hai-jun Qiu +6 位作者 Zeng-gui Kuang Ting-wei Li Yu-lin He Meng-jie Xu Xiao-xue Wang Hong-fei Lai Jin Liang 《China Geology》 CAS CSCD 2024年第1期36-50,共15页
Many locations with concentrated hydrates at vents have confirmed the presence of abundant thermogenic gas in the middle of the Qiongdongnan Basin(QDNB).However,the impact of deep structures on gasbearing fluids migra... Many locations with concentrated hydrates at vents have confirmed the presence of abundant thermogenic gas in the middle of the Qiongdongnan Basin(QDNB).However,the impact of deep structures on gasbearing fluids migration and gas hydrates distribution in tectonically inactive regions is still unclear.In this study,the authors apply high-resolution 3D seismic and logging while drilling(LWD)data from the middle of the QDNB to investigate the influence of deep-large faults on gas chimneys and preferred gasescape pipes.The findings reveal the following:(1)Two significant deep-large faults,F1 and F2,developed on the edge of the Songnan Low Uplift,control the dominant migration of thermogenic hydrocarbons and determine the initial locations of gas chimneys.(2)The formation of gas chimneys is likely related to fault activation and reactivation.Gas chimney 1 is primarily arises from convergent fluid migration resulting from the intersection of the two faults,while the gas chimney 2 benefits from a steeper fault plane and shorter migration distance of fault F2.(3)Most gas-escape pipes are situated near the apex of the two faults.Their reactivations facilitate free gas flow into the GHSZ and contribute to the formation of fracture‐filling hydrates. 展开更多
关键词 Venting gas hydrates Deep-large faults gas chimney gas-escape pipes High-resolution 3D seismic Logging while drilling Qiongdongnan Basin South China Sea
下载PDF
Inter-layer interference for multi-layered tight gas reservoir in the absence and presence of movable water 被引量:2
19
作者 Tao Zhang Bin-Rui Wang +5 位作者 Yu-Long Zhao Lie-Hui Zhang Xiang-Yang Qiao Lei Zhang Jing-Jing Guo Hung Vo Thanh 《Petroleum Science》 SCIE EI CAS CSCD 2024年第3期1751-1764,共14页
Due to the dissimilarity among different producing layers,the influences of inter-layer interference on the production performance of a multi-layer gas reservoir are possible.However,systematic studies of inter-layer ... Due to the dissimilarity among different producing layers,the influences of inter-layer interference on the production performance of a multi-layer gas reservoir are possible.However,systematic studies of inter-layer interference for tight gas reservoirs are really limited,especially for those reservoirs in the presence of water.In this work,five types of possible inter-layer interferences,including both absence and presence of water,are identified for commingled production of tight gas reservoirs.Subsequently,a series of reservoir-scale and pore-scale numerical simulations are conducted to quantify the degree of influence of each type of interference.Consistent field evidence from the Yan'an tight gas reservoir(Ordos Basin,China)is found to support the simulation results.Additionally,suggestions are proposed to mitigate the potential inter-layer interferences.The results indicate that,in the absence of water,commingled production is favorable in two situations:when there is a difference in physical properties and when there is a difference in the pressure system of each layer.For reservoirs with a multi-pressure system,the backflow phenomenon,which significantly influences the production performance,only occurs under extreme conditions(such as very low production rates or well shut-in periods).When water is introduced into the multi-layer system,inter-layer interference becomes nearly inevitable.Perforating both the gas-rich layer and water-rich layer for commingled production is not desirable,as it can trigger water invasion from the water-rich layer into the gas-rich layer.The gas-rich layer might also be interfered with by water from the neighboring unperforated water-rich layer,where the water might break the barrier(eg weak joint surface,cement in fractures)between the two layers and migrate into the gas-rich layer.Additionally,the gas-rich layer could possibly be interfered with by water that accumulates at the bottom of the wellbore due to gravitational differentiation during shut-in operations. 展开更多
关键词 Tight gas Comingled production INTERFERENCE Two-phase flow Water blocking
下载PDF
Geochemical characteristics and exploration significance of ultra-deep Sinian oil and gas from Well Tashen 5,Tarim Basin,NW China 被引量:3
20
作者 Zicheng Cao Anlai Ma +4 位作者 Qinqi Xu Quanyong Pan Kai Shang Fan Feng Yongli Liu 《Energy Geoscience》 EI 2024年第1期24-36,共13页
The Well Tashen 5(TS5),drilled and completed at a vertical depth of 9017 m in the Tabei Uplift of the Tarim Basin,NW China,is the deepest well in Asia.It has been producing both oil and gas from the Sinian at a depth ... The Well Tashen 5(TS5),drilled and completed at a vertical depth of 9017 m in the Tabei Uplift of the Tarim Basin,NW China,is the deepest well in Asia.It has been producing both oil and gas from the Sinian at a depth of 8780e8840 m,also the deepest in Asia in terms of oil discovery.In this paper,the geochemical characteristics of Sinian oil and gas from the well were investigated and compared with those of Cambrian oil and gas discovered in the same basin.The oil samples,with Pr/Ph ratio of 0.78 and a whole oil carbon isotopic value of31.6‰,have geochemical characteristics similar to those of Ordovician oils from the No.1 fault in the North Shuntuoguole area(also named Shunbei area)and the Middle Cambrian oil from wells Zhongshen 1(ZS1)and Zhongshen 5(ZS5)of Tazhong Uplift.The maturity of light hydrocarbons,diamondoids and aromatic fractions all suggest an approximate maturity of 1.5%e1.7%Ro for the samples.The(4-+3-)methyldiamantane concentration of the samples is 113.5 mg/g,indicating intense cracking with a cracking degree of about 80%,which is consistent with the high bottom hole temperature(179℃).The Sinian gas samples are dry with a dryness coefficient of 0.97.The gas is a mixture of kerogen-cracking gas and oil-cracking gas and has Ro values ranging between 1.5%and 1.7%,and methane carbon isotopic values of41.6‰.Based on the equivalent vitrinite reflectance(R_(eqv)=1.51%e1.61%)and the thermal evolution of source rocks from the Cambrian Yu'ertusi Formation of the same well,it is proposed that the Sinian oil and gas be mainly sourced from the Cambrian Yu'ertusi Formation during the Himalayan period but probably also be joined by hydrocarbon of higher maturity that migrated from other source rocks in deeper formations.The discovery of Sinian oil and gas from Well TS5 suggests that the ancient ultra-deep strata in the northern Tarim Basin have the potential for finding volatile oil or condensate reservoirs. 展开更多
关键词 Ultra-deep Sinian oil and gas Oil-cracking Well Tashen 5 Tarim Basin
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部