Discharge coefficients of 3-in-1 hole of three inclination angles and three spacing between holes are presented which described the discharge behavior of a row of holes. The inlet and outlet of the 3-in-1 hole both ha...Discharge coefficients of 3-in-1 hole of three inclination angles and three spacing between holes are presented which described the discharge behavior of a row of holes. The inlet and outlet of the 3-in-1 hole both have a 15° lateral expansion. The flow conditions considered are mainstream turbulence intensities and density ratios of secondary flow to mainstream. The momentum flux ratios varied in the range from 1 to 4. The comparison is made of the discharge coefficients of three shaped holes to find an optimal hole with low flow loss. The results show that the discharge coefficients of 3-in- 1 hole are highest in three shaped holes and therefore this article is focused on the measurements of discharge coefficients of 3-in-1 hole for various geometries and aerodynamic parameters. The measured results of 3-in-1 hole indicate that turbulence intensities, density ratios and momentum flux ratios have weak influence on discharge coefficients for inclination angle of 20°. The high turbulence intensity yields the small discharge coefficients for inclination angle of 45° and 90°. The increased both momentum flux ratios and density ratios lead to the increased discharge coefficients for inclination angle of 45° and 90°. The increased inclination angle causes the rapidly increased discharge coefficients. There is a weak dependence of discharge coefficients on hole pitches.展开更多
This article presents the data about heat transfer coefficient ratios, film cooling effectiveness and heat loads for the injection through cylindrical holes, 3-in-1 holes and fanned holes in order to characterize the ...This article presents the data about heat transfer coefficient ratios, film cooling effectiveness and heat loads for the injection through cylindrical holes, 3-in-1 holes and fanned holes in order to characterize the film cooling performance downstream of a row of holes with 45° inclination and 3 hole spacing apart. The trip wire is placed upstream at a distance of 10 times diameter of the cooling hole from the hole center to keep mainstream fully turbulent. Both inlet and outlet of 3-in-1 holes have a 15° lateral expansion. The outlet of fanned holes has a lateral expansion. CO2 is applied for secondary injection to obtain a density ratio of 1.5. Momentum flux ratio varies from 1 to 4. The results indicate that the increased momentum flux ratio significantly increases heat transfer coefficient and slightly improve film cooling effectiveness for the injection through cylindrical holes. A weak dependence of heat transfer coefficient and film cooling effectiveness, respectively, on momentum flux ratio has been identified for the injection through 3-in-1 holes. The in- crease of the momentum flux ratio decreases heat transfer coefficient and significantly increases film cooling effectiveness for the injection through fanned holes. In terms of the film cooling performance, the fanned holes are the best while the cylindrical holes are the worst among the three hole shapes under study.展开更多
文摘Discharge coefficients of 3-in-1 hole of three inclination angles and three spacing between holes are presented which described the discharge behavior of a row of holes. The inlet and outlet of the 3-in-1 hole both have a 15° lateral expansion. The flow conditions considered are mainstream turbulence intensities and density ratios of secondary flow to mainstream. The momentum flux ratios varied in the range from 1 to 4. The comparison is made of the discharge coefficients of three shaped holes to find an optimal hole with low flow loss. The results show that the discharge coefficients of 3-in- 1 hole are highest in three shaped holes and therefore this article is focused on the measurements of discharge coefficients of 3-in-1 hole for various geometries and aerodynamic parameters. The measured results of 3-in-1 hole indicate that turbulence intensities, density ratios and momentum flux ratios have weak influence on discharge coefficients for inclination angle of 20°. The high turbulence intensity yields the small discharge coefficients for inclination angle of 45° and 90°. The increased both momentum flux ratios and density ratios lead to the increased discharge coefficients for inclination angle of 45° and 90°. The increased inclination angle causes the rapidly increased discharge coefficients. There is a weak dependence of discharge coefficients on hole pitches.
文摘This article presents the data about heat transfer coefficient ratios, film cooling effectiveness and heat loads for the injection through cylindrical holes, 3-in-1 holes and fanned holes in order to characterize the film cooling performance downstream of a row of holes with 45° inclination and 3 hole spacing apart. The trip wire is placed upstream at a distance of 10 times diameter of the cooling hole from the hole center to keep mainstream fully turbulent. Both inlet and outlet of 3-in-1 holes have a 15° lateral expansion. The outlet of fanned holes has a lateral expansion. CO2 is applied for secondary injection to obtain a density ratio of 1.5. Momentum flux ratio varies from 1 to 4. The results indicate that the increased momentum flux ratio significantly increases heat transfer coefficient and slightly improve film cooling effectiveness for the injection through cylindrical holes. A weak dependence of heat transfer coefficient and film cooling effectiveness, respectively, on momentum flux ratio has been identified for the injection through 3-in-1 holes. The in- crease of the momentum flux ratio decreases heat transfer coefficient and significantly increases film cooling effectiveness for the injection through fanned holes. In terms of the film cooling performance, the fanned holes are the best while the cylindrical holes are the worst among the three hole shapes under study.