期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
THE THEORETICAL STUDY ON INTERSECTION POINT RULE FOR HOMOLOGUES IN GAS CHROMATOGRAPHY
1
作者 Fu An WANG Qing Lai TIAN Ying Chen GUO Ting Zhu CAO Department of Chemical Engineering,Zhengzhou Institute of Technology,Zhengzhou 450002 《Chinese Chemical Letters》 SCIE CAS CSCD 1993年第9期795-796,共2页
The intersection point rule for homologues in gas chromatography was discovered many years ago,now more and more application and development are occurring in recent years~[2-6], but there are few systemic theoretical ... The intersection point rule for homologues in gas chromatography was discovered many years ago,now more and more application and development are occurring in recent years~[2-6], but there are few systemic theoretical studies.In this paper,based on the basic equation of reten- tion values in gas chromatography,we prove the intersection point rule of homologues from mathematics,study the factors affecting intersection point position,give the physical meaning of intersection point,and explain the experimental rules in references. 展开更多
关键词 WANG THE THEORETICAL STUDY ON INTERSECTION point RULE FOR HOMOLOGUES IN gas CHROMATOGRAPHY gas
下载PDF
Determining short chain fatty acids in sewage sludge hydrolysate: A comparison of three analytical methods and investigation of sample storage effects
2
作者 Victor Ibrahim Tobias Hey Karin Jonsson 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2014年第4期926-933,共8页
In anaerobic digestion, the production of short-chain fatty acids (SCFAs) can be beneficial or harmful to the overall process, depending on the concentration of accumulated acids. Therefore, the accurate determinati... In anaerobic digestion, the production of short-chain fatty acids (SCFAs) can be beneficial or harmful to the overall process, depending on the concentration of accumulated acids. Therefore, the accurate determination of the SCFA concentration in both fresh and stored sludge hydrolysates is important. To select a suitable method for monitoring SCFAs during the anaerobic digestion of sewage sludge, the accuracy of three available analytical methods, including 5 pH point acid titration (TITRA5), gas chromatography (GC), and spectrophotometry, were compared in the present study. The results revealed that TITRA5 and GC displayed better agreement in the achieved measurements and higher precision and accuracy than the spectrophotometric assay, as supported by the application of different statistical models. TITRA5 excelled in titrating unfiltered hydrolysate while simultaneously measuring the alkalinity, whereas the GC method provided detailed information on the contribution of different fatty acids to the total acidity. In contrast, the spectrophotometric assay suffered from many forms of interference, depending on the sample's matrix. SCFA production followed the pattern of enzymatic reactions and fitted the Michaelis-Menten model. In addition to promoting TITRA5 as an accurate and robust analytical tool for routine SCFA analyses, this comparative study also demonstrated the possibility of storing hydrolysate samples at different temperatures and durations without altering the SCFA measurements. 展开更多
关键词 five pH point titration gas chromatography spectrophotometry short-chain fatty acids sludge hydrolysis sample storage
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部