期刊文献+
共找到3,204篇文章
< 1 2 161 >
每页显示 20 50 100
Investigating Load Regulation Characteristics of a Wind-PV-Coal Storage Multi-Power Generation System
1
作者 Zhongping Liu Enhui Sun +3 位作者 Jiahao Shi Lei Zhang Qi Wang Jiali Dong 《Energy Engineering》 EI 2024年第4期913-932,共20页
There is a growing need to explore the potential of coal-fired power plants(CFPPs)to enhance the utilization rate of wind power(wind)and photovoltaic power(PV)in the green energy field.This study developed a load regu... There is a growing need to explore the potential of coal-fired power plants(CFPPs)to enhance the utilization rate of wind power(wind)and photovoltaic power(PV)in the green energy field.This study developed a load regulation model for a multi-power generation system comprising wind,PV,and coal energy storage using realworld data.The power supply process was divided into eight fundamental load regulation scenarios,elucidating the influence of each scenario on load regulation.Within the framework of the multi-power generation system with the wind(50 MW)and PV(50 MW)alongside a CFPP(330 MW),a lithium-iron phosphate energy storage system(LIPBESS)was integrated to improve the system’s load regulation flexibility.The energy storage operation strategy was formulated based on the charging and discharging priority of the LIPBESS for each basic scenario and the charging and discharging load calculation method of LIPBESS auxiliary regulation.Through optimization using the particle swarm algorithm,the optimal capacity of LIPBESS was determined to be within the 5.24-4.88 MWh range.From an economic perspective,the LIPBESS operating with CFPP as the regulating power source was 49.1% lower in capacity compared to the renewable energy-based storage mode. 展开更多
关键词 Wind power coal-fired power PV multi-power generation system lithium-iron phosphate energy storage system
下载PDF
A Temporary Frequency Response Strategy Using a Voltage Source-Based PermanentMagnet Synchronous Generator and Energy Storage Systems
2
作者 Baogang Chen Fenglin Miao +2 位作者 Jing Yang Chen Qi Wenyan Ji 《Energy Engineering》 EI 2024年第2期541-555,共15页
Energy storage systems(ESS)and permanent magnet synchronous generators(PMSG)are speculated to be able to exhibit frequency regulation capabilities by adding differential and proportional control loops with different c... Energy storage systems(ESS)and permanent magnet synchronous generators(PMSG)are speculated to be able to exhibit frequency regulation capabilities by adding differential and proportional control loops with different control objectives.The available PMSG kinetic energy and charging/discharging capacities of the ESS were restricted.To improve the inertia response and frequency control capability,we propose a short-term frequency support strategy for the ESS and PMSG.To this end,the weights were embedded in the control loops to adjust the participation of the differential and proportional controls based on the system frequency excursion.The effectiveness of the proposed control strategy was verified using PSCAD/EMTDC.The simulations revealed that the proposed strategy could improve the maximum rate of change of the frequency nadir and maximum frequency excursion.Therefore,it provides a promising solution of ancillary services for frequency regulation of PMSG and ESS. 展开更多
关键词 Inertial control PMSG ESS wind power generation frequency support
下载PDF
Experimental Study on the Performance of ORC System Based on Ultra-Low Temperature Heat Sources
3
作者 Tianyu Zhou Liang Hao +2 位作者 Xin Xu Meng Si Lian Zhang 《Energy Engineering》 EI 2024年第1期145-168,共24页
This paper discussed the experimental results of the performance of an organic Rankine cycle(ORC)system with an ultra-low temperature heat source.The low boiling point working medium R134a was adopted in the system.Th... This paper discussed the experimental results of the performance of an organic Rankine cycle(ORC)system with an ultra-low temperature heat source.The low boiling point working medium R134a was adopted in the system.The simulated heat source temperature(SHST)in this work was set from 39.51°C to 48.60°C by the simulated heat source module.The influence of load percentage of simulated heat source(LPSHS)between 50%and 70%,the rotary valve opening(RVO)between 20%and 100%,the resistive load between 36Ωand 180Ωor the no-load of the generator,as well as the autumn and winter ambient temperature on the system performance were studied.The results showed that the stability of the system was promoted when the generator had a resistive load.The power generation(PG)and generator speed(GS)of the system in autumn were better than in winter,but the expander pressure ratio(EPR)was lower than in winter.Keep RVO unchanged,the SHST,the mass flow rate(MFR)of the working medium,GS,and the PG of the system increased with the increasing of LPSHS for different generator resistance load values.When the RVO was 60%,LPSHS was 70%,the SHST was 44.15°C and the resistive load was 72Ω,the highest PG reached 15.11 W.Finally,a simulation formula was obtained for LPSHS,resistance load,and PG,and its correlation coefficient was between 0.9818 and 0.9901.The formula can accurately predict the PG.The experimental results showed that the standard deviation between the experimental and simulated values was below 0.0792,and the relative error was within±5%. 展开更多
关键词 ORC load percentage of simulated heat source resistive load rotary valve opening power generation
下载PDF
Exploration and Application Practice of Energy Conservation Theory and Method in Steel Manufacturing Process System
4
作者 Jiaxiang Hao Yuanyuan Wu 《Frontiers of Metallurgical Industry》 2024年第2期37-42,共6页
This article briefly discusses the theoretical basis and overall goals of energy conservation in the steel manufacturing process system.It is proposed that in the process of implementing system energy conservation,it ... This article briefly discusses the theoretical basis and overall goals of energy conservation in the steel manufacturing process system.It is proposed that in the process of implementing system energy conservation,it is necessary to fully recognize and utilize the characteristics and functional advantages of the steel manufacturing process,pay more attention to energy quality,firmly grasp the overall goal of system optimization,focus on the integrated optimization of gas,steam,and waste heat systems,and propose the idea of constructing a"steel chemi-cal gas electricity heating cooling multi generation system".Based on practice,the main principles,models,and effects of implementing systematic energy conservation in steel enterprises have been proposed. 展开更多
关键词 steel manufacturing process system energy-saving system optimization energy conservation and emis-sion reduction waste heat and energy generation POLYGENERATION
下载PDF
Phase control in an open A-type system with spontaneously generated coherence 被引量:4
5
作者 崔妮 樊锡君 +3 位作者 李爱云 刘呈普 龚尚庆 徐至展 《Chinese Physics B》 SCIE EI CAS CSCD 2007年第3期718-724,共7页
This paper investigates the control role of the relative phase between the probe and driving fields on the gain, dispersion and populations in an open A system with spontaneously generated coherence (SGC). It shows ... This paper investigates the control role of the relative phase between the probe and driving fields on the gain, dispersion and populations in an open A system with spontaneously generated coherence (SGC). It shows that by adjusting the value of the relative phase, a change from lasing with inversion to lasing without inversion can be realized; the values and frequency spectrum regions of the inversionless gain and dispersion can be obviously varied; high refractive index with zero absorption and electromagnetically induced transparency can be achieved. It is also found that when the driving field is resonant, the shapes of the dispersion and the gain curves versus the probe detuning are very similar if the relative phase of the dispersion lags π/2 than that of the gain, however for the off-resonant driving field the similarity will disappear; the gain, dispersion and populations are periodical functions of the relative phase, the modulation period is always 2π; the contribution of SGC to the inversionless gain and dispersion is much larger than that of the dynamically induced coherence. 展开更多
关键词 spontaneously generated coherence phase control electromagnetically induced transparency lasing without inversion
下载PDF
Effect of spontaneously generated coherence on inversionless lasing gain in an atomic system with Doppler broadening 被引量:3
6
作者 马慧 谭霞 +2 位作者 田淑芬 仝殿民 樊锡君 《Chinese Physics B》 SCIE EI CAS CSCD 2007年第8期2400-2406,共7页
We have studied the effect of the spontaneously generated coherence (SGC) on gain of lasing without inversion (LWI) in a closed three-level A-type atomic system with Doppler broadening. It is shown that, regardles... We have studied the effect of the spontaneously generated coherence (SGC) on gain of lasing without inversion (LWI) in a closed three-level A-type atomic system with Doppler broadening. It is shown that, regardless of the driving and probe fields being co- or counter-propagating, at a suitable value of the Doppler width, we can obtain a much larger LWI gain with SGC than that without SGC; and the region of the LWI gain spectrum with SGC is obviously larger than that without SGC. When the Doppler width takes a constant value, the gain does not monotonically decrease or increase with increasing strength of SGC, the largest LWI gain can be obtained by adjusting strength of SGC. Generally speaking, the co-propagating probe and driving fields is favourable to obtain a larger LWI gain. 展开更多
关键词 spontaneously generated coherence Doppler broadening lasing without inversion GAIN
下载PDF
A NEW APPROACH TO TRANSMISSION SYSTEM PROTECTION WITH FRULT GENERATED NOISE 被引量:1
7
作者 L.L.Lai City University UK 《电力系统及其自动化学报》 CSCD 1993年第1期1-9,共9页
The use of non-power frequency components for protection measurements in an area that has received relatively little attention. Although work on the use of switched stack tuners has been reported for fault detection, ... The use of non-power frequency components for protection measurements in an area that has received relatively little attention. Although work on the use of switched stack tuners has been reported for fault detection, the sensitivity of switched arrangements is limited by scnsitivity of directional detectors for switching purposes. This paper presents an alternative non-switching scheme which is relatively simple.A simplified typical 400kV system with the line trap, stack tuner, coupling capacitor and bus capacitance to earth is considered. Fault studies by using the EMTP have been carried out, frequency-dependent pararnctcrs are used for the line representation. Arcing faults have also bccn investigated and the results show a great promise of the scheme. 展开更多
关键词 FAULT generated noise TRANSMISSION system protection.
下载PDF
Influence of Doppler broadening and spontaneously generated coherence on propagation effect in a quasi lambda-type four-level system 被引量:1
8
作者 刘中波 梁颖 +1 位作者 贾克宁 樊锡君 《Chinese Physics B》 SCIE EI CAS CSCD 2012年第2期322-332,共11页
In this paper we study influences of Doppler broadening, spontaneously generated coherence, and other system parameters on propagation effect in a quasi lambda-type four-level atomic system. It is shown that when the ... In this paper we study influences of Doppler broadening, spontaneously generated coherence, and other system parameters on propagation effect in a quasi lambda-type four-level atomic system. It is shown that when the Doppler broadening is present, generally speaking, the values of gain and intensity of lasing without inversion (i.e. the probe field) in the co-propagating probe and driving fields case are much larger than those in the counter-propagating case; considerably larger gain and intensity of lasing without inversion than those without the Doppler broadening can be obtained by choosing appropriate values of the Doppler broadening width and spontaneously generated coherence strength. The gain and intensity of lasing without inversion increase with the increase of spontaneously generated coherence strength; when spontaneously generated coherence is present, much larger gain and intensity of lasing without inversion than those in the case without spontaneously generated coherence can be obtained. Choosing suitable values of the probe detuning, Rabi frequencies of the driving and pump fields at the entrance of the medium also can remarkably enhance the gain and intensity of lasing without inversion. 展开更多
关键词 four-level system propagation effect spontaneously generated coherence Doppler broadening lasing without inversion
下载PDF
Fiber Bragg Grating Sensor Array System Based on Digital Phase Generated Carrier Demodulation and Reference Compensation Method 被引量:2
9
作者 Jun He Fang Li Hao Xiao Yu-Liang Liu 《Journal of Electronic Science and Technology of China》 2008年第4期389-392,共4页
A novel fiber Bragg grating (FBG) sensor array system based on digital phase generated carrier (PGC) demodulation and reference compensation method is proposed and set up. Experimental results confirm that the dig... A novel fiber Bragg grating (FBG) sensor array system based on digital phase generated carrier (PGC) demodulation and reference compensation method is proposed and set up. Experimental results confirm that the digital PGC demodulation can be used for wavelength-division-multiplexed FBG sensor array and the reference compensation method can reduce the environmental interference by approximately 40 dB in the frequency range from 20 Hz to 2 kHz. The minimum detectable wavelength-shift of the sensor system is 1 × 10^-3 pm/Hz^1/2. 展开更多
关键词 Fiber Bragg grating (FBG) sensor phase generated carrier (PGC) reference compensation method wavelength division multiplexing.
下载PDF
Phase control of light amplification in steady and transient processes in an inverted-Y atomic system with spontaneously generated coherence
10
作者 田思聪 佟存柱 +7 位作者 万仁刚 宁永强 秦丽 刘云 王立军 张航 王增斌 高锦岳 《Chinese Physics B》 SCIE EI CAS CSCD 2014年第4期279-287,共9页
We investigate the effects of spontaneously generated coherence (SGC) on both the steady and transient gain properties in a four-level inverted-Y-type atomic system in the presence of a weak probe, two strong cohere... We investigate the effects of spontaneously generated coherence (SGC) on both the steady and transient gain properties in a four-level inverted-Y-type atomic system in the presence of a weak probe, two strong coherent fields, and an incoherent pump. For the steady process, we find that the inversionless gain mainly origins from SGC. In particular, we can modulate the inversionless gain by changing the relative phase between the two fields. Moreover, the amplitude of the gain peak can be enhanced and the additional gain peak can appear by changing the detuning of the coupling field. As for the transient process, the transient gain properties can also be dramatically affected by the SGC. Compared to the case without SGC, the transient gain can be greatly enhanced with completely eliminated transient absorption by choosing the proper relative phase between the two fields. And the inverted-Y-type system with SGC can be simulated in both atomic and semiconductor quantum well systems avoiding the conditions of SGC. 展开更多
关键词 spontaneously generated coherence gain without inversion transient evolution relative phase
下载PDF
A semantic and emotion-based dual latent variable generation model for a dialogue system 被引量:1
11
作者 Ming Yan Xingrui Lou +2 位作者 Chien Aun Chan Yan Wang Wei Jiang 《CAAI Transactions on Intelligence Technology》 SCIE EI 2023年第2期319-330,共12页
With the development of intelligent agents pursuing humanisation,artificial intelligence must consider emotion,the most basic spiritual need in human interaction.Traditional emotional dialogue systems usually use an e... With the development of intelligent agents pursuing humanisation,artificial intelligence must consider emotion,the most basic spiritual need in human interaction.Traditional emotional dialogue systems usually use an external emotional dictionary to select appropriate emotional words to add to the response or concatenate emotional tags and semantic features in the decoding step to generate appropriate responses.However,selecting emotional words from a fixed emotional dictionary may result in loss of the diversity and consistency of the response.We propose a semantic and emotion-based dual latent variable generation model(Dual-LVG)for dialogue systems,which is able to generate appropriate emotional responses without an emotional dictionary.Different from previous work,the conditional variational autoencoder(CVAE)adopts the standard transformer structure.Then,Dual-LVG regularises the CVAE latent space by introducing a dual latent space of semantics and emotion.The content diversity and emotional accuracy of the generated responses are improved by learning emotion and semantic features respectively.Moreover,the average attention mechanism is adopted to better extract semantic features at the sequence level,and the semi-supervised attention mechanism is used in the decoding step to strengthen the fusion of emotional features of the model.Experimental results show that Dual-LVG can successfully achieve the effect of generating different content by controlling emotional factors. 展开更多
关键词 conditional variational autoencoder dual latent space emotional responses latent variable generation
下载PDF
Optimal Scheduling Method of Cogeneration System with Heat Storage Device Based on Memetic Algorithm 被引量:1
12
作者 Haibo Li YibaoWang +2 位作者 Xinfu Pang Wei Liu Xu Zhang 《Energy Engineering》 EI 2023年第2期317-343,共27页
Electric-heat coupling characteristics of a cogeneration system and the operating mode of fixing electricity with heat are the main reasons for wind abandonment during the heating season in the Three North area.To imp... Electric-heat coupling characteristics of a cogeneration system and the operating mode of fixing electricity with heat are the main reasons for wind abandonment during the heating season in the Three North area.To improve the wind-power absorption capacity and operating economy of the system,the structure of the system is improved by adding a heat storage device and an electric boiler.First,aiming at the minimum operating cost of the system,the optimal scheduling model of the cogeneration system,including a heat storage device and electric boiler,is constructed.Second,according to the characteristics of the problem,a cultural gene algorithm program is compiled to simulate the calculation example.Finally,through the system improvement,the comparison between the conditions before and after and the simulation solutions of similar algorithms prove the effectiveness of the proposed scheme.The simulation results show that adding the heat storage device and electric boiler to the scheduling optimization process not only improves the wind power consumption capacity of the cogeneration system but also reduces the operating cost of the system by significantly reducing the coal consumption of the unit and improving the economy of the system operation.The cultural gene algorithm framework has both the global evolution process of the population and the local search for the characteristics of the problem,which has a better optimization effect on the solution. 展开更多
关键词 Combined heat and power generation heat storage device memetic algorithm simulated annealing wind abandonment
下载PDF
The Measuring System for Estimation of Power of Wind Flow Generated by Train Movement and Its Experimental Testing
13
作者 Oleksandr Mokin Borys Mokin Vadym Bazalytskyy 《Energy and Power Engineering》 2014年第11期333-339,共7页
The measuring system for estimation of power of wind flow generated by the train movement has been created. The advantages of the proposed system are the cheapness and simple design. With its simplicity of design and ... The measuring system for estimation of power of wind flow generated by the train movement has been created. The advantages of the proposed system are the cheapness and simple design. With its simplicity of design and easy build-up of channels, designed measuring system can be used for a wide range of technical problems. This paper describes the design process, validation and conducting the first field test of this measuring system. 展开更多
关键词 POWER Generation WIND TURBINE WIND Flow Sensor Measurement
下载PDF
Investigation of Nonlinear PI Multi-loop Control Strategy for Aircraft HVDC Generator System with Wound Rotor Synchronous Machine 被引量:1
14
作者 Zhaoyang Qu Zhuoran Zhang +1 位作者 Jincai Li Heng Shi 《CES Transactions on Electrical Machines and Systems》 CSCD 2023年第1期92-99,共8页
In order to enhance the transient performance of aircraft high voltage DC(HVDC)generation system with wound rotor synchronous machine(WRSM)under a wide speed range,the nonlinear PI multi-loop control strategy is propo... In order to enhance the transient performance of aircraft high voltage DC(HVDC)generation system with wound rotor synchronous machine(WRSM)under a wide speed range,the nonlinear PI multi-loop control strategy is proposed in this paper.Traditional voltage control method is hard to achieve the dynamic performance requirements of the HVDC generation system under a wide speed range,so the nonlinear PI parameter adjustment,load current feedback and speed feedback are added to the voltage and excitation current double loop control.The transfer function of the HVDC generation system is derived,and the relationship between speed,load current and PI parameters is obtained.The PI parameters corresponding to the load at certain speed are used to shorten the adjusting time when the load suddenly changes.The dynamic responses in transient processes are analyzed by experiment.The results illustrate that the WRSM HVDC generator system with this method has better dynamic performance. 展开更多
关键词 Aircraft HVDC generation system More electric aircraft Transient performance Wound rotor synchronous machine
下载PDF
Dynamic and Power Generation Features of A Wind-Wave Hybrid System Consisting of A Spar-Type Wind Turbine and An Annular Wave Energy Converter in Irregular Waves
15
作者 ZHOU Bin-zhen ZHENG Zhi +3 位作者 HONG Miao-wen JIN Peng WANG Lei CHEN Fan-ting 《China Ocean Engineering》 SCIE EI CSCD 2023年第6期923-933,共11页
Combining wave energy converters(WECs)with floating offshore wind turbines proves a potential strategy to achieve better use of marine renewable energy.The full coupling investigation on the dynamic and power generati... Combining wave energy converters(WECs)with floating offshore wind turbines proves a potential strategy to achieve better use of marine renewable energy.The full coupling investigation on the dynamic and power generation features of the hybrid systems under operational sea states is necessary but limited by numerical simulation tools.Here an aero-hydro-servo-elastic coupling numerical tool is developed and applied to investigate the motion,mooring tension,and energy conversion performance of a hybrid system consisting of a spar-type floating wind turbine and an annular wave energy converter.Results show that the addition of the WEC has no significant negative effect on the dynamic performance of the platform and even enhances the rotational stability of the platform.For surge and pitch motion,the peak of the spectra is originated from the dominating wave component,whereas for the heave motion,the peak of the spectrum is the superposed effect of the dominating wave component and the resonance of the system.The addition of the annular WEC can slightly improve the wind power by making the rotor to be in a better position to face the incoming wind and provide considerable wave energy production,which can compensate for the downtime of the offshore wind. 展开更多
关键词 wind energy wave energy hybrid system MOTION power generation
下载PDF
Study on characteristics of acoustic signals generated by different DC discharge modes
16
作者 熊紫兰 王渝淇 李孟琦 《Plasma Science and Technology》 SCIE EI CAS CSCD 2023年第5期85-92,共8页
Acoustic signals contain rich discharge information.In this study,the acoustic signal characteristics of transient glow,spark,and glow discharges generated through DC pin–pin discharge were investigated.The signals w... Acoustic signals contain rich discharge information.In this study,the acoustic signal characteristics of transient glow,spark,and glow discharges generated through DC pin–pin discharge were investigated.The signals were analyzed in the time,frequency,and time–frequency domains,and the correlation between the electric and the acoustic signal was studied statistically.The results show that glow discharge does not produce measurable sound signals.For the other modes,with a decrease in the discharge gap,the amplitude of the acoustic signal increases sharply with mode transformation,the short-time average energy becomes higher,and the frequency components are more abundant.Meanwhile,the current pulse and sound pressure pulse have a one-to-one relationship in the transient glow and spark regimes,and they are positively correlated in amplitude.A brief theoretical analysis of the mechanism of plasma sound and the trends of signals in different modes is presented.Essentially,the change in the discharge energy is closely related to the sound generation of the plasma. 展开更多
关键词 low-temperature plasma DC discharge discharging modes acoustic signal sound generation
下载PDF
Analysis and Power Quality Improvement in Hybrid Distributed Generation System with Utilization of Unified Power Quality Conditioner
17
作者 Noor Zanib Munira Batool +4 位作者 Saleem Riaz Farkhanda Afzal Sufian Munawar Ibtisam Daqqa Najma Saleem 《Computer Modeling in Engineering & Sciences》 SCIE EI 2023年第2期1105-1136,共32页
This paper presents a comprehensive study that includes the sizing and power flow by series and parallel inverters in a distributed generation system(DGs)that integrates the system of hybrid wind photovoltaic with a u... This paper presents a comprehensive study that includes the sizing and power flow by series and parallel inverters in a distributed generation system(DGs)that integrates the system of hybrid wind photovoltaic with a unified power quality conditioner(UPQC).In addition to supplying active power to the utility grid,the system of hybrid wind photovoltaic functions as a UPQC,compensating reactive power and suppressing the harmonic load currents.Additionally,the load is supplied with harmonic-free,balanced and regulated output voltages.Since PVWind-UPQC is established on a dual compensation scheme,the series inverter works like a sinusoidal current source,while the parallel inverter works like a sinusoidal voltage source.Consequently,a smooth alteration from interconnected operating modes to island operating modes and vice versa can be achieved without load voltage transients.Since PV-Wind-UPQC inverters handle the energy generated through the hybrid wind photovoltaic system and the energy demanded through the load,the converters should be sized cautiously.A detailed study of the flow of power via the PV-Wind-UPQC is imperative to gain a complete understanding of the system operation and the proper design of the converters.Thus,curves that allow the sizing of the power converters according to the power flow via the converters are presented and discussed.Simulation results are presented to assess both steady state and dynamic performances of the grid connected hybrid system of PV-Wind-UPQC.This investigation is verified by simulating and analyzing the results with Matlab/Simulink. 展开更多
关键词 PHOTOVOLTAIC wind turbine unified power quality conditioner power flow distributed generation system
下载PDF
Unmanned aerial vehicle based intelligent triage system in mass-casualty incidents using 5G and artificial intelligence
18
作者 Jiafa Lu Xin Wang +7 位作者 Linghao Chen Xuedong Sun Rui Li Wanjing Zhong Yajing Fu Le Yang Weixiang Liu Wei Han 《World Journal of Emergency Medicine》 SCIE CAS CSCD 2023年第4期273-279,共7页
BACKGROUND:Rapid on-site triage is critical after mass-casualty incidents(MCIs)and other mass injury events.Unmanned aerial vehicles(UAVs)have been used in MCIs to search and rescue wounded individuals,but they mainly... BACKGROUND:Rapid on-site triage is critical after mass-casualty incidents(MCIs)and other mass injury events.Unmanned aerial vehicles(UAVs)have been used in MCIs to search and rescue wounded individuals,but they mainly depend on the UAV operator’s experience.We used UAVs and artificial intelligence(AI)to provide a new technique for the triage of MCIs and more efficient solutions for emergency rescue.METHODS:This was a preliminary experimental study.We developed an intelligent triage system based on two AI algorithms,namely OpenPose and YOLO.Volunteers were recruited to simulate the MCI scene and triage,combined with UAV and Fifth Generation(5G)Mobile Communication Technology real-time transmission technique,to achieve triage in the simulated MCI scene.RESULTS:Seven postures were designed and recognized to achieve brief but meaningful triage in MCIs.Eight volunteers participated in the MCI simulation scenario.The results of simulation scenarios showed that the proposed method was feasible in tasks of triage for MCIs.CONCLUSION:The proposed technique may provide an alternative technique for the triage of MCIs and is an innovative method in emergency rescue. 展开更多
关键词 Mass-casualty incidents Emergency medical service Unmanned aerial vehicle Fifth Generation Mobile Communication Technology Artificial intelligence
下载PDF
SMINER:Detecting Unrestricted and Misimplemented Behaviors of Software Systems Based on Unit Test Cases
19
作者 Kyungmin Sim Jeong Hyun Yi Haehyun Cho 《Computers, Materials & Continua》 SCIE EI 2023年第5期3257-3274,共18页
Despite the advances in automated vulnerability detection approaches,security vulnerabilities caused by design flaws in software systems are continuously appearing in real-world systems.Such security design flaws can ... Despite the advances in automated vulnerability detection approaches,security vulnerabilities caused by design flaws in software systems are continuously appearing in real-world systems.Such security design flaws can bring unrestricted and misimplemented behaviors of a system and can lead to fatal vulnerabilities such as remote code execution or sensitive data leakage.Therefore,it is an essential task to discover unrestricted and misimplemented behaviors of a system.However,it is a daunting task for security experts to discover such vulnerabilities in advance because it is timeconsuming and error-prone to analyze the whole code in detail.Also,most of the existing vulnerability detection approaches still focus on detecting memory corruption bugs because these bugs are the dominant root cause of software vulnerabilities.This paper proposes SMINER,a novel approach that discovers vulnerabilities caused by unrestricted and misimplemented behaviors.SMINER first collects unit test cases for the target system from the official repository.Next,preprocess the collected code fragments.SMINER uses pre-processed data to show the security policies that can occur on the target system and creates a test case for security policy testing.To demonstrate the effectiveness of SMINER,this paper evaluates SMINER against Robot Operating System(ROS),a real-world system used for intelligent robots in Amazon and controlling satellites in National Aeronautics and Space Administration(NASA).From the evaluation,we discovered two real-world vulnerabilities in ROS. 展开更多
关键词 Security vulnerability test case generation security policy test robot operating system vulnerability assessment
下载PDF
Availability Capacity Evaluation and Reliability Assessment of Integrated Systems Using Metaheuristic Algorithm
20
作者 A.Durgadevi N.Shanmugavadivoo 《Computer Systems Science & Engineering》 SCIE EI 2023年第3期1951-1971,共21页
Contemporarily,the development of distributed generations(DGs)technologies is fetching more,and their deployment in power systems is becom-ing broad and diverse.Consequently,several glitches are found in the recent st... Contemporarily,the development of distributed generations(DGs)technologies is fetching more,and their deployment in power systems is becom-ing broad and diverse.Consequently,several glitches are found in the recent studies due to the inappropriate/inadequate penetrations.This work aims to improve the reliable operation of the power system employing reliability indices using a metaheuristic-based algorithm before and after DGs penetration with feeder system.The assessment procedure is carried out using MATLAB software and Mod-ified Salp Swarm Algorithm(MSSA)that helps assess the Reliability indices of the proposed integrated IEEE RTS79 system for seven different configurations.This algorithm modifies two control parameters of the actual SSA algorithm and offers a perfect balance between the exploration and exploitation.Further,the effectiveness of the proposed schemes is assessed using various reliability indices.Also,the available capacity of the extended system is computed for the best configuration of the considered system.The results confirm the level of reli-able operation of the extended DGs along with the standard RTS system.Speci-fically,the overall reliability of the system displays superior performance when the tie lines 1 and 2 of the DG connected with buses 9 and 10,respectively.The reliability indices of this case namely SAIFI,SAIDI,CAIDI,ASAI,AUSI,EUE,and AEUE shows enhancement about 12.5%,4.32%,7.28%,1.09%,4.53%,12.00%,and 0.19%,respectively.Also,a probability of available capacity at the low voltage bus side is accomplished a good scale about 212.07 times/year. 展开更多
关键词 Meta-heuristic algorithm modified salp swarm algorithm reliability indices distributed generations(DGs)
下载PDF
上一页 1 2 161 下一页 到第
使用帮助 返回顶部