This work addresses the tensile properties of glass fiber reinforced polymers (GFRP) and investigates the different ways of estimating them without the cost associated with experimentation. This attempt is achieved th...This work addresses the tensile properties of glass fiber reinforced polymers (GFRP) and investigates the different ways of estimating them without the cost associated with experimentation. This attempt is achieved through comparison between experimental results, derived in accordance with the ASTM standards, and results obtained using the mechanics of composite materials. The experimental results are also compared to results derived from work by other researchers in order to corroborate the findings regarding the correlation of tensile properties of the GFRP material and the fiber volume fraction.展开更多
This paper studied the preparation and mechanical properties of glass fiber reinforced polymer-matrix composite rings prepared by filament winding assisted by ultraviolet(UV)curing.A ray-tracing method was used to cal...This paper studied the preparation and mechanical properties of glass fiber reinforced polymer-matrix composite rings prepared by filament winding assisted by ultraviolet(UV)curing.A ray-tracing method was used to calculate the penetration ability of UV light in the resin casting,and then a typical composite ring with dual⁃curing characteristics was prepared by UV-assisted curing.The effects of winding speed and thermal initiator concentration on the distribution of fiber fraction and mechanical properties were studied.Microscopic morphology was used for the observation of the differences in fiber volume fraction.Mechanical properties tests and scanning electron micrographs were performed to investigate the failure and damage mechanisms of the composite ring samples.The ray tracing results indicate that the UV light can pass through a single yarn thickness and the energy transmitted is sufficient to cure the back side quickly.The experimental results show that the mechanical properties of the composite ring prepared in this paper are comparable to those of the heat-cured samples,which is sufficient to meet the requirements of the flywheel.展开更多
This paper presents the static and fatigue tests of hybrid(bonded/bolted)glass fiber reinforced polymer(GFRP)joints.Nine specimens of single-lap hybrid GFRP joints have been fabricated to study the static and fatigue ...This paper presents the static and fatigue tests of hybrid(bonded/bolted)glass fiber reinforced polymer(GFRP)joints.Nine specimens of single-lap hybrid GFRP joints have been fabricated to study the static and fatigue behaviors in the experimental campaign.The static tests of uniaxial tension loading are first conducted,from which the static ultimate bearing capacities of the joints are obtained.High-cycle fatigue tests are subsequently carried out so that the fatigue failure mode,fatigue life,and stiffness degradation of joints can be obtained.The measuring techniques including acoustic emission monitoring and three-dimensional digital image correlation have been employed in the tests to record the damage development process.The results revealed that the static strength and fatigue behavior of such thick hybrid GFRP joints were controlled by the bolted connections.The four stages of fatigue failure process are obtained from tests and acoustic emission signals analysis:cumulative damage of adhesive layer,damage of the adhesive layer,cumulative damage of GFRP plate,and damage of GFRP plate.The fatigue life and stiffness degradation can be improved by more bolts.The S-N(fatigue stress versus life)curves for the fatigue design of the single-lap hybrid GFRP joints under uniaxial tension loading are also proposed.展开更多
Combined with fiber Bragg grating(FBG)sensing technology,four glass fiber reinforced polymer(GFRP)anti-floating anchors and four steel anti-floating anchors were tested for on-site destructive failure to investigate t...Combined with fiber Bragg grating(FBG)sensing technology,four glass fiber reinforced polymer(GFRP)anti-floating anchors and four steel anti-floating anchors were tested for on-site destructive failure to investigate the anchoring performance and the bonding characteristics between GFRP anti-floating anchor and concrete floor.The test results show that bending GFRP anchor will be broken at the common boundary between vertical anchorage section and bending section during the pullout process,and the spring-back load provided by the rupture contributes to a decrease of bearing capacity and an inflection point on the load-slip curve.The loaddisplacement curve of the straight anchor GFRP anti-floating anchor is smoother and has better predictability than the same type of steel anchor.Additionally,different forms of GFRP anti-floating bolt have different bondslip constitutive relations.By introducing the sliding-slip correction factor of bending bolt,constitutive models describing the rising-section of sliding-slip relation of bending and straight-anchored GFRP anti-floating bolt are established respectively.The model can fit the test results rightly.展开更多
This paper presents the results of a test program for flexure reinforcing characteristics of gless fiber-rein forced polymer(GFRP) sheets bonded to masonry beams. A total of eight specimens subjected to monotonic fo...This paper presents the results of a test program for flexure reinforcing characteristics of gless fiber-rein forced polymer(GFRP) sheets bonded to masonry beams. A total of eight specimens subjected to monotonic four-point bending were tested up to failure. These specimens were constructed with two different bond patterns. Six of these specimens were reinforced by using GFRP sheets prior to testing, and the remaining two were not reinforced. The test results indicate a significant increase in both load-bearing capacity and ductile performance of the reinforced walls over the unreinforced ones.展开更多
The mechanical behavior of concrete-filled glass fiber reinforced polymer(GFRP)-steel tube structures under combined seismic loading is investigated in this study. Four same-sized specimens with different GFRP layout ...The mechanical behavior of concrete-filled glass fiber reinforced polymer(GFRP)-steel tube structures under combined seismic loading is investigated in this study. Four same-sized specimens with different GFRP layout modes were tested by a quasi-static test system. Finite element analysis(FEA) was also undertaken and the results were presented. Results of the numerical simulation compared well with those from experimental tests. Parametric analysis was conducted by using the FE models to evaluate the effects of GFRP thickness, axial compression rate, and cross sectional steel ratio. The experimental and numerical results show that the technique of GFRP strengthening is effective in improving the seismic performance of traditional concrete-filled steel tubes, with variations related to different GFRP layout modes.展开更多
In order to research the shear behavior of glass fiber reinforced polymer (GFRP) reinforced concrete beam with circular cross section, based on the test results of 36 concrete beams subjected to four-point loading up ...In order to research the shear behavior of glass fiber reinforced polymer (GFRP) reinforced concrete beam with circular cross section, based on the test results of 36 concrete beams subjected to four-point loading up to failure, the shear capacity and mechanical properties of deformation were analyzed comparatively between GFRP reinforced concrete (GFRP-RC) beams and steel reinforced concrete (steel-RC) beams. Furthermore, influencing factors of shear capacity of GFRP-RC beam with circular cross section were also investigated. The test results indicate that the failure modes of GFRP-RC and steel-RC beams are the same, but the crack patterns are slightly different. And, the shear capacity of GFRP-RC beam firstly increases with the reduction of shear span ratio, and then decreases. In addition, it was found that the influencing coefficient of GFRP on concrete increases with shear span ratio reducing.展开更多
文摘This work addresses the tensile properties of glass fiber reinforced polymers (GFRP) and investigates the different ways of estimating them without the cost associated with experimentation. This attempt is achieved through comparison between experimental results, derived in accordance with the ASTM standards, and results obtained using the mechanics of composite materials. The experimental results are also compared to results derived from work by other researchers in order to corroborate the findings regarding the correlation of tensile properties of the GFRP material and the fiber volume fraction.
基金supported by the National Key Laboratory of Science and Technology on Helicopter Transmission(Nanjing University of Aeronautics and Astronautics)(No.HTL-A-20K01)the Pretension and Relaxation Mechanism of Thermoplastic Prepreg Tape Winding with Tension Used to Hi-Speed Permanent Magnet Machine Sleeve(No.51903249)the Priority Academic Program Development of Jiangsu Higher Education Institutions and the Fundamental Research Funds for the Central Universities。
文摘This paper studied the preparation and mechanical properties of glass fiber reinforced polymer-matrix composite rings prepared by filament winding assisted by ultraviolet(UV)curing.A ray-tracing method was used to calculate the penetration ability of UV light in the resin casting,and then a typical composite ring with dual⁃curing characteristics was prepared by UV-assisted curing.The effects of winding speed and thermal initiator concentration on the distribution of fiber fraction and mechanical properties were studied.Microscopic morphology was used for the observation of the differences in fiber volume fraction.Mechanical properties tests and scanning electron micrographs were performed to investigate the failure and damage mechanisms of the composite ring samples.The ray tracing results indicate that the UV light can pass through a single yarn thickness and the energy transmitted is sufficient to cure the back side quickly.The experimental results show that the mechanical properties of the composite ring prepared in this paper are comparable to those of the heat-cured samples,which is sufficient to meet the requirements of the flywheel.
基金the National Natural Science Foundation of China(No.51978400)。
文摘This paper presents the static and fatigue tests of hybrid(bonded/bolted)glass fiber reinforced polymer(GFRP)joints.Nine specimens of single-lap hybrid GFRP joints have been fabricated to study the static and fatigue behaviors in the experimental campaign.The static tests of uniaxial tension loading are first conducted,from which the static ultimate bearing capacities of the joints are obtained.High-cycle fatigue tests are subsequently carried out so that the fatigue failure mode,fatigue life,and stiffness degradation of joints can be obtained.The measuring techniques including acoustic emission monitoring and three-dimensional digital image correlation have been employed in the tests to record the damage development process.The results revealed that the static strength and fatigue behavior of such thick hybrid GFRP joints were controlled by the bolted connections.The four stages of fatigue failure process are obtained from tests and acoustic emission signals analysis:cumulative damage of adhesive layer,damage of the adhesive layer,cumulative damage of GFRP plate,and damage of GFRP plate.The fatigue life and stiffness degradation can be improved by more bolts.The S-N(fatigue stress versus life)curves for the fatigue design of the single-lap hybrid GFRP joints under uniaxial tension loading are also proposed.
基金the National Natural Science Foundation of China(Nos.51708316 and 51778312)the China Postdoctoral Science Foundation(No.2018M632641)+1 种基金the Shandong Provincial Key Research and Development Program(Nos.2017GSF16107 and 2018GSF117008)the Shandong Provincial Natural Science Foundation(Nos.ZR2016EEQ08 and ZR2017PEE006)。
文摘Combined with fiber Bragg grating(FBG)sensing technology,four glass fiber reinforced polymer(GFRP)anti-floating anchors and four steel anti-floating anchors were tested for on-site destructive failure to investigate the anchoring performance and the bonding characteristics between GFRP anti-floating anchor and concrete floor.The test results show that bending GFRP anchor will be broken at the common boundary between vertical anchorage section and bending section during the pullout process,and the spring-back load provided by the rupture contributes to a decrease of bearing capacity and an inflection point on the load-slip curve.The loaddisplacement curve of the straight anchor GFRP anti-floating anchor is smoother and has better predictability than the same type of steel anchor.Additionally,different forms of GFRP anti-floating bolt have different bondslip constitutive relations.By introducing the sliding-slip correction factor of bending bolt,constitutive models describing the rising-section of sliding-slip relation of bending and straight-anchored GFRP anti-floating bolt are established respectively.The model can fit the test results rightly.
基金Funded by Natural Science Foundation of Liaoning Province (No. 20022005).
文摘This paper presents the results of a test program for flexure reinforcing characteristics of gless fiber-rein forced polymer(GFRP) sheets bonded to masonry beams. A total of eight specimens subjected to monotonic four-point bending were tested up to failure. These specimens were constructed with two different bond patterns. Six of these specimens were reinforced by using GFRP sheets prior to testing, and the remaining two were not reinforced. The test results indicate a significant increase in both load-bearing capacity and ductile performance of the reinforced walls over the unreinforced ones.
基金Project supported by the National Natural Science Foundation of China(No.51178068)the Fundamental Research Funds for the Central Universities of China(No.3132013315)
文摘The mechanical behavior of concrete-filled glass fiber reinforced polymer(GFRP)-steel tube structures under combined seismic loading is investigated in this study. Four same-sized specimens with different GFRP layout modes were tested by a quasi-static test system. Finite element analysis(FEA) was also undertaken and the results were presented. Results of the numerical simulation compared well with those from experimental tests. Parametric analysis was conducted by using the FE models to evaluate the effects of GFRP thickness, axial compression rate, and cross sectional steel ratio. The experimental and numerical results show that the technique of GFRP strengthening is effective in improving the seismic performance of traditional concrete-filled steel tubes, with variations related to different GFRP layout modes.
基金the National Natural Science Foundation of China (No.51078318)the Program for New Century Excellent Talents in University (No.10-0667)the Fundamental Research Funds for the Central Universities (No.SWJTU09CX006)
文摘In order to research the shear behavior of glass fiber reinforced polymer (GFRP) reinforced concrete beam with circular cross section, based on the test results of 36 concrete beams subjected to four-point loading up to failure, the shear capacity and mechanical properties of deformation were analyzed comparatively between GFRP reinforced concrete (GFRP-RC) beams and steel reinforced concrete (steel-RC) beams. Furthermore, influencing factors of shear capacity of GFRP-RC beam with circular cross section were also investigated. The test results indicate that the failure modes of GFRP-RC and steel-RC beams are the same, but the crack patterns are slightly different. And, the shear capacity of GFRP-RC beam firstly increases with the reduction of shear span ratio, and then decreases. In addition, it was found that the influencing coefficient of GFRP on concrete increases with shear span ratio reducing.