The enhancement of convective heat transfer in a glass tube heat exchanger was researched.A simple and efficient method using spiral wire turbulence promotors in the glass tube isrecommended.A series of experiments we...The enhancement of convective heat transfer in a glass tube heat exchanger was researched.A simple and efficient method using spiral wire turbulence promotors in the glass tube isrecommended.A series of experiments were conducted,and thetlon have been obtained.Performance evaluations Nr the enhanced heattrans比r In this heatexchanger are su门niii ed up and discussed Based on the vlewp01nt Of止berinodynaffi1CS,止he avaHableenergy lossof the heat transfer swtern Inside the tube Is analwed to determine and evaluate the over-all趴ct oQthe enhanced heat transfer,The mechanism ofenhanced heat transfer]n the glass tubeand the Influence of turbutlvlty In the fough tube are also analysed and discussed.展开更多
Solar water heaters which provide a cost-effective and environmental friendly approach to hot water generation are in widespread application. Evacuated tube solar water heaters perform better than flat plate solar wat...Solar water heaters which provide a cost-effective and environmental friendly approach to hot water generation are in widespread application. Evacuated tube solar water heaters perform better than flat plate solar water heaters as a result of their greater surface area exposed for sunlight absorption. Water-in-glass evacuated tube solar water heaters are widely used as compared to heat-pipe solar water heaters due to their short payback periods. In this study, the performance of water-in-glass evacuated tube solar water heater is investigated through experiments under the climatic conditions in Kenya. The results revealed a daily efficiency range of 0.58 - 0.65 and a daily final outlet temperature greater than 55<span style="white-space:normal;">°</span>C given an initial temperature of 25°C.展开更多
A simulation of the stress analysis for a vacuum glass bulb of 35 inch (V) 120° Color Picture Tube(CPT) has been developed. It is shown that extra large deflection angle Color Picture Tube is viable. Increase ...A simulation of the stress analysis for a vacuum glass bulb of 35 inch (V) 120° Color Picture Tube(CPT) has been developed. It is shown that extra large deflection angle Color Picture Tube is viable. Increase in the deflection angle will shorten the de展开更多
System performance of solar water heaters depends upon collector and storage tank designs, solar radiation intensity and ambient temperature, amongst others. Evacuated glass tube collectors with U-tubes inside are les...System performance of solar water heaters depends upon collector and storage tank designs, solar radiation intensity and ambient temperature, amongst others. Evacuated glass tube collectors with U-tubes inside are less prone to leakages than the all-glass or the heat pipe types. U-tube solar water heaters suspended on walls and balconies could help overcome present day roof space restriction and increasing apartment-style housing. As such, their performance would depend upon its orientation when mounted in a vertical position. This paper reports the results of outdoor tests conducted on natural convection U-tube solar water heaters oriented towards different directions. Long and short term test procedures were employed to allow us to compare their performances as if they were tested simultaneously side-by-side.展开更多
The assembled form of thick-wall glass fiber reinforced plastics (GFRP) tube and 0Cr18Ni9 austenitic stainless steel pipes was designed as the radius thermal-insulating and load-supporting structure in cryogenic vesse...The assembled form of thick-wall glass fiber reinforced plastics (GFRP) tube and 0Cr18Ni9 austenitic stainless steel pipes was designed as the radius thermal-insulating and load-supporting structure in cryogenic vessels. In order to study the thermal leakage and gap changes on the support structure, as well as radius temperature and stress distribution on GFRP tube, an experimental investigation has been taken. The results indicate that the support structure is proved to fit well as thermal-insulating and load-supporting part in cryo-genic vessels, furthermore has high security during cryogenic applications.展开更多
An open-cell porous bulk metallic glass (BMG) with a diameter of at least 6 mm was fabricated by using an U-turn quartz tube and infiltration casting around soluble NaCI placeholders. The pore formation and glassy s...An open-cell porous bulk metallic glass (BMG) with a diameter of at least 6 mm was fabricated by using an U-turn quartz tube and infiltration casting around soluble NaCI placeholders. The pore formation and glassy structure were examined by optical microscopy (OM), scanning electron microscopy (SEM) and X-ray diffraction (XRD). The results show that the pores or cells are connected to each other and the specimen is composed of a mostly glassy phase. This paper provides a suitable method for fabrication of porous BMG and BMG with larger size in diameter.展开更多
文摘The enhancement of convective heat transfer in a glass tube heat exchanger was researched.A simple and efficient method using spiral wire turbulence promotors in the glass tube isrecommended.A series of experiments were conducted,and thetlon have been obtained.Performance evaluations Nr the enhanced heattrans比r In this heatexchanger are su门niii ed up and discussed Based on the vlewp01nt Of止berinodynaffi1CS,止he avaHableenergy lossof the heat transfer swtern Inside the tube Is analwed to determine and evaluate the over-all趴ct oQthe enhanced heat transfer,The mechanism ofenhanced heat transfer]n the glass tubeand the Influence of turbutlvlty In the fough tube are also analysed and discussed.
文摘Solar water heaters which provide a cost-effective and environmental friendly approach to hot water generation are in widespread application. Evacuated tube solar water heaters perform better than flat plate solar water heaters as a result of their greater surface area exposed for sunlight absorption. Water-in-glass evacuated tube solar water heaters are widely used as compared to heat-pipe solar water heaters due to their short payback periods. In this study, the performance of water-in-glass evacuated tube solar water heater is investigated through experiments under the climatic conditions in Kenya. The results revealed a daily efficiency range of 0.58 - 0.65 and a daily final outlet temperature greater than 55<span style="white-space:normal;">°</span>C given an initial temperature of 25°C.
文摘A simulation of the stress analysis for a vacuum glass bulb of 35 inch (V) 120° Color Picture Tube(CPT) has been developed. It is shown that extra large deflection angle Color Picture Tube is viable. Increase in the deflection angle will shorten the de
文摘System performance of solar water heaters depends upon collector and storage tank designs, solar radiation intensity and ambient temperature, amongst others. Evacuated glass tube collectors with U-tubes inside are less prone to leakages than the all-glass or the heat pipe types. U-tube solar water heaters suspended on walls and balconies could help overcome present day roof space restriction and increasing apartment-style housing. As such, their performance would depend upon its orientation when mounted in a vertical position. This paper reports the results of outdoor tests conducted on natural convection U-tube solar water heaters oriented towards different directions. Long and short term test procedures were employed to allow us to compare their performances as if they were tested simultaneously side-by-side.
文摘The assembled form of thick-wall glass fiber reinforced plastics (GFRP) tube and 0Cr18Ni9 austenitic stainless steel pipes was designed as the radius thermal-insulating and load-supporting structure in cryogenic vessels. In order to study the thermal leakage and gap changes on the support structure, as well as radius temperature and stress distribution on GFRP tube, an experimental investigation has been taken. The results indicate that the support structure is proved to fit well as thermal-insulating and load-supporting part in cryo-genic vessels, furthermore has high security during cryogenic applications.
文摘An open-cell porous bulk metallic glass (BMG) with a diameter of at least 6 mm was fabricated by using an U-turn quartz tube and infiltration casting around soluble NaCI placeholders. The pore formation and glassy structure were examined by optical microscopy (OM), scanning electron microscopy (SEM) and X-ray diffraction (XRD). The results show that the pores or cells are connected to each other and the specimen is composed of a mostly glassy phase. This paper provides a suitable method for fabrication of porous BMG and BMG with larger size in diameter.