期刊文献+
共找到604篇文章
< 1 2 31 >
每页显示 20 50 100
A Glassy Carbon Electrode Modified with Cellulose Nanofibrils from Ammophila arenaria for the Sensitive Detection of L-Trytophan
1
作者 Sondes Bourigua Feriel Boussema +4 位作者 Zayneb Jebali Houcine Barhoumi Hatem Majdoub Abderrazak Maaref Nicole Jaffrezic-Renault 《Journal of Sensor Technology》 2024年第3期35-50,共16页
L-tryptophan is an essential amino acid for human health. Nanofibrillated cellulose (NFC) from marram grass (Ammophila arenaria) extracted from plants harvested in the center of Tunisia was used for the first time for... L-tryptophan is an essential amino acid for human health. Nanofibrillated cellulose (NFC) from marram grass (Ammophila arenaria) extracted from plants harvested in the center of Tunisia was used for the first time for the modification of a glassy carbon electrode (GCE), for the sensitive detection of L-tryptophan (Trp). After spectroscopic and morphological characterization of the extracted NFC, the GC electrode modification was monitored through cyclic voltammetry. The NFC-modified electrode exhibited good analytical performance in detecting Trp with a wide linear range between 7.5 × 10−4 mM and 10−2 mM, a detection limit of 0.2 µM, and a high sensitivity of 140.0 µA∙mM−1. Additionally, the NFC/GCE showed a good reproducibility, good selectivity versus other amino acids, uric acid, ascorbic acid, and good applicability to the detection of Trp in urine samples. 展开更多
关键词 Nanofibrillated Cellulose CHITOSAN Chemically Modified glassy carbon electrode Electrochemical Detection L-TRYPTOPHAN
下载PDF
Voltammetric behavior of sedative drug midazolam at glassy carbon electrode in solubilized systems 被引量:5
2
作者 Rajeev Jain Rajeev Kumar Yadav 《Journal of Pharmaceutical Analysis》 SCIE CAS 2012年第2期123-129,共7页
Redox behavior of midazolam was studied at a glassy carbon electrode in various buffer systems,supporting electrolytes and pH using differential paise,square-wave and cyclic voltammetry.Based on its reduction behavior... Redox behavior of midazolam was studied at a glassy carbon electrode in various buffer systems,supporting electrolytes and pH using differential paise,square-wave and cyclic voltammetry.Based on its reduction behavior,a direct differential pulse voltammetric method has been developed and validated for the determination of midazolam in parenteral dosage.Three welldefined peaks were observed in 0.1% SLS,Britton-Robinson (BR) buffer of pH 2.5.The effect of surfaetants like sodium lauryl sulfate (SLS),cetyl trimethyl ammonium bromide (CTAB) and Tween 20 was studied.Among these surfactants SLS showed significant enhancement in reduction peak.The cathodic peak currents were directly proportional to the concentration of midazolam with correlation coetfficient of 0.99. 展开更多
关键词 MIDAZOLAM VOLTAMMETRY SURFACTANT glassy carbon electrode Parenteral dosage form
下载PDF
Electrooxidation of sulfanilamide and its voltammetric determination in pharmaceutical formulation,human urine and serum on glassy carbon electrode 被引量:2
3
作者 Bruno R.L.Ferraz Tiago Guimaraes +1 位作者 Demetrius Profeti Luciene P.R.Profeti 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2018年第1期55-59,共5页
For the first time, sulfanilamide(SFD) was determined in otologic solution, human urine and serum by electroanalytical techniques on glassy carbon electrode(GCE). The cyclic voltammetry(CV) experiments showed an irrev... For the first time, sulfanilamide(SFD) was determined in otologic solution, human urine and serum by electroanalytical techniques on glassy carbon electrode(GCE). The cyclic voltammetry(CV) experiments showed an irreversible oxidation peak at t 1.06 V in 0.1 mol/L BRBS(p H ? 2.0) at 50 m V/s. Different voltammetric scan rates(from 10 to 250 m V/s) suggested that the oxidation of SFD on the GCE was a diffusioncontrolled process. Square-wave voltammetry(SWV) method under optimized conditions showed a linear response to SFD from 5.0 to 74.7 μmol/L(R ? 0.999) with detection and quantification limits of 0.92 and3.10 μmol/L, respectively. The developed SWV method showed better results for detection limit and linear range than the chronoamperometry method. It has been successfully applied to determine SFD concentration in pharmaceutical formulation, human urine and serum samples with recovery close to 100%. 展开更多
关键词 SQUARE-WAVE VOLTAMMETRY SULFANILAMIDE glassy carbon electrode Biological FLUIDS
下载PDF
Voltammetric sensor based on cobalt-poly(methionine)-modified glassy carbon electrode for determination of estriol hormone in pharmaceuticals and urine 被引量:1
4
作者 Eliziana S. Gomes Fernando R.F. Leite +2 位作者 Bruno R.L. Ferraz Henrique A.J.L. Mourao Andrea R. Malagutti 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2019年第5期347-357,共11页
A voltammetric sensor based on the electropolymerization of cobalt-poly(methionine)(Co-poly(Met)) on a glassy carbon electrode (GCE) was developed and applied for the determination of estriol by differential pulse vol... A voltammetric sensor based on the electropolymerization of cobalt-poly(methionine)(Co-poly(Met)) on a glassy carbon electrode (GCE) was developed and applied for the determination of estriol by differential pulse voltammetry (DPV) for the first time. The electrochemical properties of the Co-poly(Met)/GCE were analysed by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). Scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS) were used to characterize the polymers on the GCE surface. The deposition of the Co-poly(Met) film on the GCE surface enhanced the sensor electronic transfer. CV studies revealed that estriol exhibits an irreversible oxidation peak at t0.58 V for the Co-poly(Met)/GCE (vs. Ag/AgCl reference electrode) in 0.10 mol/L Britton-Robinson buffer solution (pH=7.0). Different voltammetric scan rates (10-200 mV/s) suggested that the estriol oxidation on the Co-poly(Met)/GCE surface is controlled by adsorption and diffusion processes. Based on the optimized DPV conditions, the linear responses for estriol quantification were from 0.596 μmol/L to 4.76 μmol/L (R2 =0.996) and from 5.66 μmol/L to 9.90 μmol/L (R2 =0.994) with a limit of detection (LOD) of 0.0340 μmol/L and a limit of quantification (LOQ) of 0.113 μmol/L. The DPV-Co-poly(Met)/GCE method provided good intra-day and inter-day repeatability with RSD values lower than 5%. Also, no interference of real sample matrices was observed on the estriol voltammetric response, making the DPV-Copoly( Met)/GCE highly selective for estriol. The accuracy test showed that the estriol recovery was in the ranges 96.7%-103% and 98.7%-102% for pharmaceutical tablets and human urine, respectively. The estriol quantification in pharmaceutical tablets performed by the Co-poly(Met)/GCE-assisted DPV method was comparable to the official analytical protocols. 展开更多
关键词 ESTRIOL ELECTROANALYSIS Differential pulse voltammetry Cobalt-poly(methionine) film-modified glassy carbon electrode
下载PDF
Cyclic Voltammetry Determination of Epinephrine with a Nano-gold Modified Glassy Carbon Electrode in the Presence of High Concentration Ascorbic Acid 被引量:1
5
作者 HongZHANG XueQinGUI 《Chinese Chemical Letters》 SCIE CAS CSCD 2002年第2期153-156,共4页
Nano-gold (NG) modified glassy carbon electrodes (GCEs) were used for determination of epinephrine (EP) in the presence of high concentration ascorbic acid (AA) by cyclic voltammetry (CV). This modified electrode can... Nano-gold (NG) modified glassy carbon electrodes (GCEs) were used for determination of epinephrine (EP) in the presence of high concentration ascorbic acid (AA) by cyclic voltammetry (CV). This modified electrode can not only catalytically oxidize EP and AA, but also separate the catalytic peak potentials of EP and AA by about 183.5 mV. In pH = 7.0 ogisogate byffer solution, the linear range of epinephrine was 5 106 ~ 1 ?10-4 mol/L. 展开更多
关键词 NANO-GOLD glassy carbon electrode EPINEPHRINE ascorbic acid cyclic voltammetry.
下载PDF
Direct Electrochemistry and Electrocatalysis of Hemoglobin at PAMAM Dendrimer-MWNTs-Au Nanoparticles Composite Film Modified Glassy Carbon Electrode 被引量:1
6
作者 LIU Xing-mei ZHANG Xue-yu +4 位作者 ZHAO Yi-li LIU Wei-lu WANG Bao-jun ZHANG Yi-hua ZHANG Zhi-quan 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2010年第5期723-728,共6页
The direct electron transfer of hemoglobin at the PAMAM-MWNTs-AuNPs composite film modified glassy carbon electrode was studied. In a phosphate buffer solution(PBS, pH=7.0), the formal potential(E^0) of Hb was -0.... The direct electron transfer of hemoglobin at the PAMAM-MWNTs-AuNPs composite film modified glassy carbon electrode was studied. In a phosphate buffer solution(PBS, pH=7.0), the formal potential(E^0) of Hb was -0.105 V versus SCE, the electron transfer rate constant was 4.66 s-1. E^0' of Hb at the modified electrode was linearly varied in a pH range of 5.0-8.0 with a slope of-49.2 mV/pH. The Hb/PAMAM-MWNTs-AuNPs/GCE gave an excellent electrocatalytic response to the reduction of hydrogen peroxide. The catalytic current increased linearly with H2O2 concentration in a range of 1.0× 10^-6 to 2.2× 10^-3 mol/L. The detection limit was 2.0× 10^-7 mol/L at a signal to noise ratio of 3. The Michaelis-Menten constant(Km^app) was 2.95 mmol/L. 展开更多
关键词 Direct electrochemistry ELECTROCATALYSIS HEMOGLOBIN PAMAM dendrimer-MWNTs-Au nanoparticles composite glassy carbon electrode
下载PDF
Glassy carbon electrode modified with multi-walled carbon nanotubes sensor for the quantihication of antihistamine drug pheniramine in solubilized systems 被引量:1
7
作者 Rajeev Jain Sanjay Sharma 《Journal of Pharmaceutical Analysis》 SCIE CAS 2012年第1期56-61,共6页
A sensitive electroanalytical method for quantification of pheniramine in pharmaceutical formulation has been investigated on the basis of the enhanced electrochemical response at glassy carbon electrode modified with... A sensitive electroanalytical method for quantification of pheniramine in pharmaceutical formulation has been investigated on the basis of the enhanced electrochemical response at glassy carbon electrode modified with multi-walled carbon nanotubes in the presence of sodium lauryl sulfate.The experimental results suggest that the phcniramine in anionic surfactant solution exhibits electrocatalytic effect resulting in a marked enhancement of the peak current response.Peak current response is linearly dependent on the concentration of pheniramine in the range 200-1500 μg/mL with correlation coefficient 0.9987.The limit of detection is 58.31 μg/m L.The modified electrode shows good sensitivity and repeatability. 展开更多
关键词 PHENIRAMINE Sodium lauryl sulfate (SLS) glassy carbon electrode modified with multi-walled carbon nanotubes (GCE-MWCNTs) Solubilized systems Voltammetric quantification
下载PDF
Voltammetric Response of Epinephrine at Carbon Nanotube Modified Glassy Carbon Electrode and Activated Glassy Carbon Electrode
8
作者 WANG Juan TANG Ping +1 位作者 ZHAO Fa-qiong ZENG Bai-zhao 《Wuhan University Journal of Natural Sciences》 EI CAS 2005年第5期913-918,共6页
The electrochemical behavior of epinephrine at activated glassy carbon electrode and carbon nanotube-coated glassy carbon electrode was studied. Epinephrine could exhibit an anodic peak at about 0.2 V (vs. SCE) at b... The electrochemical behavior of epinephrine at activated glassy carbon electrode and carbon nanotube-coated glassy carbon electrode was studied. Epinephrine could exhibit an anodic peak at about 0.2 V (vs. SCE) at bare glassy carbon electrode, but it was very small. However, when the electrode was activated at certain potential (i.e. 1.9 V) or modified with carbon nanotube, the peak became more sensitive, resulting from the increase in electrode area in addition to the electrostatic attraction. Under the selected conditions, the anodic peak current was linear to epinephrine concentration in the range of 3.3×10^-7 - 1.1×10^-5 mol/L at activated glassy carbon electrode and in the range of 1.0×10^-5 - 5.0×10^-5 mol/L at carbon nanotube-coated electrode. The correlation coefficients were 0.998 and 0.997, respectively. The determination limit was 1.0×10^-7 mol/L. The two electrodes have been successfully applied for the determination of epinephrine in adrenaline hydrochloride injection with recovery of 95%-104%. 展开更多
关键词 EPINEPHRINE carbon nanotube glassy carbon electrode modified electrode
下载PDF
Voltammetric Response and Electrocatalysis of Glassy Carbon Electrode Modified with Monolayer Nickel Hydroxide
9
作者 Liu Shouqing Li Huiling +1 位作者 Jiang Mian Li Peibiao 《Wuhan University Journal of Natural Sciences》 CAS 1997年第1期90-94,共5页
The glassy carbon (GC) electrode modified with a monolayer nickel hydroxide (GC/Ni(OH) 2) was prepared by immersion of GC substrate in 1.0×10 -3 mol/L NiSO 4 solution, and then cyclic voltammetric scannin... The glassy carbon (GC) electrode modified with a monolayer nickel hydroxide (GC/Ni(OH) 2) was prepared by immersion of GC substrate in 1.0×10 -3 mol/L NiSO 4 solution, and then cyclic voltammetric scanning in 0.20 mol/L KOH. Similarly, GC/Co(OH) 2 electrode was prepared too. The experiments showed that the voltammetric behavior of GC/Ni(OH) 2 electrode in 0.20 mol/L KOH is more stable than that of GC/ Co(OH) 2. It was found that the GC/Ni(OH) 2 electrode acts as an effective electrocatalysis for the oxidation of hydrazine. 展开更多
关键词 glassy carbon modified electrode MONOLAYER nickel hydroxide cobalt hydroxide electroctalysis HYDRAZINE
下载PDF
Voltammetric quantitation of nitazoxanide by glassy carbon electrode
10
作者 Rajeev Jain Rajeev Kumar Yadav Jahangir Ahmad Rather 《Journal of Pharmaceutical Analysis》 SCIE CAS 2013年第6期452-455,共4页
The present study reports voltammetric reduction of nitazoxanide in Britton-Robinson (B-R) buffer by cyclic and square-wave voltammetry at glassy carbon electrode. A versatile fully validated voltammetric method for... The present study reports voltammetric reduction of nitazoxanide in Britton-Robinson (B-R) buffer by cyclic and square-wave voltammetry at glassy carbon electrode. A versatile fully validated voltammetric method for quantitative determination of nitazoxanide in pharmaceutical formulation has been proposed. A squrewave peak current was linear over the nitazoxanide concentration in the range of 20-140 ~tg/mL. The limit of detection (LOD) and limit of quantification (LOQ) was calculated to be 5.23 la~/mL and 17.45 la~/mL, respectively. 展开更多
关键词 NITAZOXANIDE Squarewave voltammetry glassy carbon electrode Pharmaceuticalformulation
下载PDF
Voltammetric Detection of Nanomolar Levels of Hypoxanthine in the Presence of Copper(Ⅱ) at Glassy Carbon Electrode
11
作者 Hu Shengshui Cui Dafu Marco Mascini 《Wuhan University Journal of Natural Sciences》 CAS 1999年第1期101-104,共4页
Nanomolar levels of the hypoxanthine in NaOH electrolyte cantaining copper(Ⅱ) can be determined by anodic stripping voltammetry at a glassy carbon electrode. In the present article hypoxanthine Cu + is shown to be ... Nanomolar levels of the hypoxanthine in NaOH electrolyte cantaining copper(Ⅱ) can be determined by anodic stripping voltammetry at a glassy carbon electrode. In the present article hypoxanthine Cu + is shown to be adsorbed on the electrode surface in the presence of an excess of copper(Ⅱ). After accumulation period, hypoxanthine Cu + was stripped from the electrode surface and the anodic current coming near to the oxidation of Cu(Ⅰ) to Cu(Ⅱ) was measured. A linear calibration curve in the range of 5 nmol/L 1.5 mmol/L hypoxanthine, with a detection limit of 0.5 nmol/L hypoxanthine were obtained. 展开更多
关键词 HYPOXANTHINE COPPER glassy carbon electrode stripping voltammetry
下载PDF
A Functionalized Multi-walled Carbon Nanotube and Gold Nanoparticle Composite-modified Glassy Carbon Electrode for the Detection of Enterovirus 71
12
作者 CHENG Jing KOU Jing +4 位作者 FAN Zhao Yu HAN Yi Qun MEI Yong GUO Zhen Zhong ZHAN Jian Bo 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2019年第7期541-545,共5页
Hand, foot, and mouth disease (HFMD) is a common infectious disease in children, occurring primarily in preschool children[1_3] with infants under three years old being gen erally susceptible. The disease is caused by... Hand, foot, and mouth disease (HFMD) is a common infectious disease in children, occurring primarily in preschool children[1_3] with infants under three years old being gen erally susceptible. The disease is caused by various enteroviruses, among which EV71 and Coxsackievirus A group 16 (Cox A16) are the most comm on ⑷.According to in formation released by the Chinese Center for Disease Control and Prevention on June 8, 2016, EV71 infection- related HFMD has been prevalent among infants and young children in China since 2007, with a high incidenee and many deaths. 展开更多
关键词 glassy carbon electrode DETECTION of ENTEROVIRUS
下载PDF
The Electrochemical Behavior and the Determination of Bavistin on Glassy Carbon Electrode
13
作者 Yuan Zhe PIAO Gui Fen WANG(Department of Chemistry, Yanbian University, Yani 133002) 《Chinese Chemical Letters》 SCIE CAS CSCD 1998年第8期747-748,共2页
In this paper, the electrochendcal behavior of bavistin (MBC) on glassy carbon electrode is reported. In a base solution of pH=9.0 NH3-NH4Cl, a sensitive anodic peak was found by cyclic voltammetry. Differential pulse... In this paper, the electrochendcal behavior of bavistin (MBC) on glassy carbon electrode is reported. In a base solution of pH=9.0 NH3-NH4Cl, a sensitive anodic peak was found by cyclic voltammetry. Differential pulse stripping voltanunetry was applied for determing MBC in grains. The detection limit is 4×10-8mo/L.The recovery is from 91.3% to 95.7%. The method has advantages of simplicity and high sensitivity. 展开更多
关键词 bavistin glassy carbon electrode cyclic voltammetry differential pulse stripping voltammetry PESTICIDE
下载PDF
Electrochemical behavior of paclitaxel and its determination at glassy carbon electrode
14
作者 Jayant I.Gowda Sharanappa T.Nandibewoor 《Asian Journal of Pharmaceutical Sciences》 SCIE CAS 2014年第1期42-49,共8页
The electrochemical behavior of paclitaxel drug was studied at a glassy carbon electrode in phosphate buffer solutions using cyclic and differential-pulse voltammetric techniques.The oxidation process was shown to be ... The electrochemical behavior of paclitaxel drug was studied at a glassy carbon electrode in phosphate buffer solutions using cyclic and differential-pulse voltammetric techniques.The oxidation process was shown to be irreversible over the pH range(3.0e10.4)and was diffusion controlled.Effects of anodic peak potential(E_(p)),anodic peak current(Ipa),scan rate,pH,heterogeneous rate constant(k^(0)),etc have been discussed.A possible electrooxidation mechanism was proposed.An analytical method was developed for the determination of paclitaxel in phosphate buffer solution at pH¼7.0 as a supporting electrolyte.The anodic peak current varied linearly with paclitaxel concentration in the range 1.0×10^-(6)M to 1.0×10^-(5)M with a limit of detection(LOD)of 1.23×10^(-8)M and limit of quantification(LOQ)of 4.10×10^(-8)M.The proposed method was successfully applied to the determination of paclitaxel in pure and real samples. 展开更多
关键词 PACLITAXEL glassy carbon electrode VOLTAMMETRY Injection analysis URINE
下载PDF
Electrochemical Behavior of Chalcone at a Glassy Carbon Electrode and Its Analytical Applications
15
作者 Keerti M. Naik Sharanappa T. Nandibewoor 《American Journal of Analytical Chemistry》 2012年第9期656-663,共8页
A simple and rapid method was developed using cyclic, differential pulse and square wave voltammetric techniques for the determination of trace-level chalcone at a glassy carbon electrode. Chalcone could produce two a... A simple and rapid method was developed using cyclic, differential pulse and square wave voltammetric techniques for the determination of trace-level chalcone at a glassy carbon electrode. Chalcone could produce two anodic peaks at about 0.514 V and 1.478 V and a cathodic peak at about -0.689 V. The differential pulse voltammerty presents a good linear response as compared to square wave voltammetry in the range of 0.2 - 10 μM with a detection limit of 0.18 μM. The proposed method was used successfully for its quantitative determination in spiked human plasma and urine as real samples. 展开更多
关键词 CHALCONE VOLTAMMETRY glassy carbon electrode ELECTROCHEMICAL Determination Oxidation
下载PDF
DIRECT ELECTROCHEMICAL BEHAVIOUR OF CYTOCHROME C AT A BARE GLASSY CARBON ELECTRODE
16
作者 Shao Jun DONC Qi Jin CHI 《Chinese Chemical Letters》 SCIE CAS CSCD 1992年第10期857-860,共4页
A reversible electron transfer between horse heart cytochrome c and a bare glassy carbon electrode was found and the dependence of direct electrochemical behaviotw on the electrode surface state was discussed.
关键词 GCE DIRECT ELECTROCHEMICAL BEHAVIOUR OF CYTOCHROME C AT A BARE glassy carbon electrode AT 七气
下载PDF
Electro Analytical Determination of Di Hydroxybenzene Isomers Using Glassy Carbon Electrode
17
作者 Mahmoud Khodari Ahmed Abd El-Rady Ekram Rabee Nada Nabil 《Journal of Chemistry and Chemical Engineering》 2014年第7期654-661,共8页
In this study, the electrochemical oxidation of CT (catechol), HQ (hydroquinone) and RS (resorcinol) was investigated using cyclic and linear sweep voltammetries at GCE (glassy carbon electrode). The GCE showe... In this study, the electrochemical oxidation of CT (catechol), HQ (hydroquinone) and RS (resorcinol) was investigated using cyclic and linear sweep voltammetries at GCE (glassy carbon electrode). The GCE showed an excellent electro activity and reversibility towards the oxidation of these isomers at different conditions. HQ and CT showed one defined oxidation peak and one defined reduction peak while RS showed one defined oxidation peak. These isomers were determined also in their binary and tertiary mixtures. The calibration curves for CT, HQ and RS were obtained in the ranges of 5 × 10-6 to 1 × 10-3 mol.dm-3, 5 × 10-6 to 5 × 10-4mol.dm-3 and 1 × 10-5 to 1× 10-3 mol.dm-3, respectively. The detection limits were 9 ×10-7, 3 × 10-7, 6 × 10-6 mol.dm3 for CT, HQ and RS, respectively. At the optimal experimental conditions, these isomers were determined in different water samples. Also, the removal of catechol from aqueous solution by adsorption on activated charcoal and alumina was studied. After 24 h, 88.7% and 65.9% of catechol was removed using charcoal and alumina, respectively. 展开更多
关键词 Di hydroxybenzene isomers glassy carbon electrode electroanalytical chemistry removal ofcatechol adsorption.
下载PDF
Use of Graphene and Cucurbit[7]uril Electrodes for the Determination of Amantadine in Biological Fluids 被引量:2
18
作者 C. S. H. Domínguez P. Hernández 《American Journal of Analytical Chemistry》 2015年第7期623-630,共8页
A differential pulse voltammetry (DPV) method for amantadine (AT) determination is developed. To this end, all the chemical and instrumental variables affecting the determination of amantadine are optimized. These stu... A differential pulse voltammetry (DPV) method for amantadine (AT) determination is developed. To this end, all the chemical and instrumental variables affecting the determination of amantadine are optimized. These studies have used three types of glassy-carbon electrode, first electrode which has not undergone surface modification or coating, to then modify the working electrode surface with two kinds of suspensions: graphene and graphene-cucurbit[7]uril (CB[7]). From studies of the mechanisms governing the electrochemical response of amantadine, it was concluded that it is an electrochemically system with a diffusive reduction phenomenon. Under optimal conditions and with the appropriate electrode modification, we proceed to study the relation between the peak intensity with the analyte concentration. Thus, we find that when the electrode surface is covered with graphene-CB[7], two linear sections are obtained, the first one in the concentration range of between 0.05 μg·mL﹣1 and 0.75 μg·mL﹣1;and the second one between 1.00 μg·mL﹣1 and 6.00 μg·mL﹣1, with Er (%) = 87 and R.S.D. = 0.94% (n = 10 at 0.5 μg·mL﹣1 level). The minimum detectable amount was 15 ng·mL﹣1 while a concentration of 44 ng·mL﹣1 was calculated as determination limit. The optimized method was applied to the determination of amantadine in biological fluids. 展开更多
关键词 glassy-carbon electrode AMANTADINE Differential Pulse VOLTAMMETRY Human URINE
下载PDF
Anodic Stripping Voltammetric Determination of Lead(II) Using Glassy Carbon Electrode Modified with Novel Calix[4]arene 被引量:1
19
作者 吕鉴泉 何锡文 +2 位作者 曾宪顺 张海丽 张正之 《Chinese Journal of Chemistry》 SCIE CAS CSCD 2003年第6期687-692,594,共6页
A new glassy carbon electrode modified with novel caHx[4]arene derivative was prepared and then applied to the selective recognition of lead ion in aqueous media by cyclic and square wave voltammtry. A new anodic stri... A new glassy carbon electrode modified with novel caHx[4]arene derivative was prepared and then applied to the selective recognition of lead ion in aqueous media by cyclic and square wave voltammtry. A new anodic stripping peak at - 0.92 V (vs. Ag/Ag+) in square wave voltammogram can be obtained by scanning the potential from - 1.5 to - 0.6 V, of which the peak current is proportional to the concentration of Pb2+. The modified electrode in 0.1 moVL HNO3 solution showed a linear voltammetric response in the range of 2.0 x 10(-8)-1.0 x 10(-6) mol/L and a detection limit of 6.1 x 10(-9) mol/L. In the modified glassy carbon electrode no significant interference occurred from alkali, alkaline and transition metal ions except Hg2+, Ag+ and Cu2+ ions, which can be eliminated by the addition of KSCN. The proposed method was successfully applied to determine lead in aqueous samples. 展开更多
关键词 arene derivative glassy carbon electrode square wave voltarnmetry lead ion
原文传递
Electrocatalytic oxidation of hydrazine with alizarin red S as a homogenous mediator on the glassy carbon electrode
20
作者 Mohammad Mazloum-Ardakani Roya Mazidi +2 位作者 Mohammad Hossein Mashhadizadeh Parvanah Rahimi Mohammad Ali Karimi 《Science China Chemistry》 SCIE EI CAS 2010年第5期1194-1200,共7页
Electro-catalytic oxidation and detection of hydrazine on a glassy carbon electrode,at pH 6.0,was studied by using alizarin red S as a homogeneous mediator.The overall number of electrons involved in the catalytic oxi... Electro-catalytic oxidation and detection of hydrazine on a glassy carbon electrode,at pH 6.0,was studied by using alizarin red S as a homogeneous mediator.The overall number of electrons involved in the catalytic oxidation of hydrazine and that involved in the rate-determining step were four and one,respectively.The interfering effect of some cations,anions and organic compounds were examined.Peak current for this process varied linearly with the square root of the scan rate.The kinetic parameters,such as the electron transfer coefficient(α) and catalytic rate constant(k) ,were determined using cyclic voltammetry,linear sweep voltammetry and chronoamperometry.The electro-catalytic response was optimized with regards to the pH,scan rate,hydrazine concentration and other variables. 展开更多
关键词 ALIZARIN red S HYDRAZINE glassy carbon electrode electro-catalytic oxidation VOLTAMMETRY
原文传递
上一页 1 2 31 下一页 到第
使用帮助 返回顶部