An edge Lyman-alpha-based beam emission spectroscopy(LyBES)diagnostic,using a heating NBI(neutral beam injection)system,is currently under development on the HL-2A tokamak.The 20-channel edge LyBES,which is intended t...An edge Lyman-alpha-based beam emission spectroscopy(LyBES)diagnostic,using a heating NBI(neutral beam injection)system,is currently under development on the HL-2A tokamak.The 20-channel edge LyBES,which is intended to measure the density fluctuation in plasma edge(from R=1960 mm to R=2026 mm)with an improved spatial resolution of 3.3 mm,is a complement to the existing conventional beam emission spectroscopy(BES)diagnostic.In this article,we introduce the progress of LyBES diagnostic,including the collection optics,the monochromator,and the detector system.The reflectance of the collection mirrors is measured to be~82%at 122 nm,and the aberration geometrical radius of the collection optics is tested to be~150μm in the aimed area.The linear dispersion of the LyBES monochromator is designed to be~0.09 nm mm^(-1).The bandwidth of the detector system with the 5×10^(7)V A^(-1)preamplifier gain is measured to be~280 kHz,and the peak-to-peak noise of the detector system is tested to be~16 mV.The finalized design,components development and testing of the LyBES diagnostic have been completed at present,and an overall performance of the LyBES diagnostic is to be confirmed in the next HL-2A campaign.展开更多
The reconstruction of the tracks of charged particles with high precision is crucial for HEP experiments to achieve their physics goals.The BESⅢdrift chamber,which is used as the tracking detector of the BESⅢexperim...The reconstruction of the tracks of charged particles with high precision is crucial for HEP experiments to achieve their physics goals.The BESⅢdrift chamber,which is used as the tracking detector of the BESⅢexperiment,has suffered from aging effects resulting in degraded tracking performance after operation for approximately 15 years.To preserve and enhance the tracking performance of BESⅢ,one of the proposals is to add one layer of a thin cylindrical CMOS pixel sensor based on state-of-the-art stitching technology between the beam pipe and the drift chamber.The improvement in the tracking performance of BESⅢwith such an additional pixel detector compared to that with only the existing drift chamber was studied using the modern common tracking software Acts,which provides a set of detector-agnostic and highly performant tracking algorithms that have demonstrated promising performance for a few high-energy physics and nuclear physics experiments.展开更多
新一代北京谱议(BESIII)数据获取系统(DAQ)是北京正负电子对撞机(BEPC)上的大型高能物理探测器的关键组成部分,分布式环境下软件的进程通信是设计和实现的关键技术之一。介绍了数据获取系统中所使用的一种分布式进程通信(IPC,Inter Proc...新一代北京谱议(BESIII)数据获取系统(DAQ)是北京正负电子对撞机(BEPC)上的大型高能物理探测器的关键组成部分,分布式环境下软件的进程通信是设计和实现的关键技术之一。介绍了数据获取系统中所使用的一种分布式进程通信(IPC,Inter Process Communication)框架,该框架基于CORBA系统进行开发。着重描述了该框架在数据获取系统在线软件中的设计、实现及应用。展开更多
基金supported by Sichuan Science and Technology Program(No.2022JDJQ0038)the National Key R&D Program of China(Nos.2022YFE03100002 and 2018YFE0303102)National Natural Science Foundation of China(Nos.12205087 and 12075241)。
文摘An edge Lyman-alpha-based beam emission spectroscopy(LyBES)diagnostic,using a heating NBI(neutral beam injection)system,is currently under development on the HL-2A tokamak.The 20-channel edge LyBES,which is intended to measure the density fluctuation in plasma edge(from R=1960 mm to R=2026 mm)with an improved spatial resolution of 3.3 mm,is a complement to the existing conventional beam emission spectroscopy(BES)diagnostic.In this article,we introduce the progress of LyBES diagnostic,including the collection optics,the monochromator,and the detector system.The reflectance of the collection mirrors is measured to be~82%at 122 nm,and the aberration geometrical radius of the collection optics is tested to be~150μm in the aimed area.The linear dispersion of the LyBES monochromator is designed to be~0.09 nm mm^(-1).The bandwidth of the detector system with the 5×10^(7)V A^(-1)preamplifier gain is measured to be~280 kHz,and the peak-to-peak noise of the detector system is tested to be~16 mV.The finalized design,components development and testing of the LyBES diagnostic have been completed at present,and an overall performance of the LyBES diagnostic is to be confirmed in the next HL-2A campaign.
基金supported by the National Natural Science Foundation of China(Nos.U2032203,12275296,12275297,12075142,12175256,12035009)National Key R&D Program of China(No.2020YFA0406302)。
文摘The reconstruction of the tracks of charged particles with high precision is crucial for HEP experiments to achieve their physics goals.The BESⅢdrift chamber,which is used as the tracking detector of the BESⅢexperiment,has suffered from aging effects resulting in degraded tracking performance after operation for approximately 15 years.To preserve and enhance the tracking performance of BESⅢ,one of the proposals is to add one layer of a thin cylindrical CMOS pixel sensor based on state-of-the-art stitching technology between the beam pipe and the drift chamber.The improvement in the tracking performance of BESⅢwith such an additional pixel detector compared to that with only the existing drift chamber was studied using the modern common tracking software Acts,which provides a set of detector-agnostic and highly performant tracking algorithms that have demonstrated promising performance for a few high-energy physics and nuclear physics experiments.
文摘新一代北京谱议(BESIII)数据获取系统(DAQ)是北京正负电子对撞机(BEPC)上的大型高能物理探测器的关键组成部分,分布式环境下软件的进程通信是设计和实现的关键技术之一。介绍了数据获取系统中所使用的一种分布式进程通信(IPC,Inter Process Communication)框架,该框架基于CORBA系统进行开发。着重描述了该框架在数据获取系统在线软件中的设计、实现及应用。