we preset the design and rabrication of a novel auai-iunction hign contrast gratings that can De usea as a polarizationselective beam splitter with transverse magnetic polarization,which performs two independent funct...we preset the design and rabrication of a novel auai-iunction hign contrast gratings that can De usea as a polarizationselective beam splitter with transverse magnetic polarization,which performs two independent functions,i.e.,reflection focusing and power equalization at a wavelength of 1550 nm.This dual-function grating profile is optimized by the rigorous coupled-wave analysis and the finite-element method.Simple analytical expressions of phase and modal guideline for the beam splitter design are given.The beam splitter based on the grating structure is experimentally studied at a distance of 160 μm from the reflection plane,the results are consistent with the theoretical results basically.展开更多
AIM: To determine age norms in the first three years of life for grating visual acuity and contrast sensitivity obtained with Lea grating test and Hiding Heidi low contrast face test. METHODS: Lea grating test was u...AIM: To determine age norms in the first three years of life for grating visual acuity and contrast sensitivity obtained with Lea grating test and Hiding Heidi low contrast face test. METHODS: Lea grating test was used to estimate binocular grating acuity and Hiding Heidi low contrast face test was used to estimate contrast sensitivity in 600 healthy infants and children. Age ranged from 3 to 36 mo subdivided into 12 groups subjected for full ophthalmologic and pediatric examinations.RESULTS: The grating acuity developed along the first three years of life. It ranged from 1.88±0.32 c/d at 3mo to 30.95±0.77 c/d at 36 mo. The most rapid development was during the first 12 mo and the slowest development was from 30 to 36 mo. The contrast sensitivity showed rapid development in the first two years of life. Its mean value ranged from 4.23±1.17 at 3mo to 78.26±8.21 at 24 mo. It was constant at the highest score(80) thereafter.CONCLUSION: Age norms for grating acuity along with contrast sensitivity offer a more comprehensive measure of spatial vision and should be incorporated in clinical practice for better visual assessment in preverbal and nonverbal children.展开更多
A novel wavefront sensing method based on phase contrast theory and coherent optical processing is proposed. The wavefront gradient field in the object plane is modulated into intensity distribution in a gang of patte...A novel wavefront sensing method based on phase contrast theory and coherent optical processing is proposed. The wavefront gradient field in the object plane is modulated into intensity distribution in a gang of patterns, making highdensity detection available. By applying the method, we have also designed a wavefront sensor. It consists of a classical coherent optical processing system, a CCD detector array, two pieces of orthogonal composite sinusoidal gratings, and a mechanical structure that can perform real-time linear positioning. The simulation results prove and demonstrate the validity of the method and the sensor in high-precision measurement of the wavefront gradient field.展开更多
基金Project supported by the Open Fund of the State Key Laboratory of Information Photonics and Optical CommunicationBeijing University of Posts and Telecommunications,China(Grant No.IPOC2019A009)the National Natural Science Foundation of China(Grant Nos.61501214 and 61501213)。
文摘we preset the design and rabrication of a novel auai-iunction hign contrast gratings that can De usea as a polarizationselective beam splitter with transverse magnetic polarization,which performs two independent functions,i.e.,reflection focusing and power equalization at a wavelength of 1550 nm.This dual-function grating profile is optimized by the rigorous coupled-wave analysis and the finite-element method.Simple analytical expressions of phase and modal guideline for the beam splitter design are given.The beam splitter based on the grating structure is experimentally studied at a distance of 160 μm from the reflection plane,the results are consistent with the theoretical results basically.
文摘AIM: To determine age norms in the first three years of life for grating visual acuity and contrast sensitivity obtained with Lea grating test and Hiding Heidi low contrast face test. METHODS: Lea grating test was used to estimate binocular grating acuity and Hiding Heidi low contrast face test was used to estimate contrast sensitivity in 600 healthy infants and children. Age ranged from 3 to 36 mo subdivided into 12 groups subjected for full ophthalmologic and pediatric examinations.RESULTS: The grating acuity developed along the first three years of life. It ranged from 1.88±0.32 c/d at 3mo to 30.95±0.77 c/d at 36 mo. The most rapid development was during the first 12 mo and the slowest development was from 30 to 36 mo. The contrast sensitivity showed rapid development in the first two years of life. Its mean value ranged from 4.23±1.17 at 3mo to 78.26±8.21 at 24 mo. It was constant at the highest score(80) thereafter.CONCLUSION: Age norms for grating acuity along with contrast sensitivity offer a more comprehensive measure of spatial vision and should be incorporated in clinical practice for better visual assessment in preverbal and nonverbal children.
文摘A novel wavefront sensing method based on phase contrast theory and coherent optical processing is proposed. The wavefront gradient field in the object plane is modulated into intensity distribution in a gang of patterns, making highdensity detection available. By applying the method, we have also designed a wavefront sensor. It consists of a classical coherent optical processing system, a CCD detector array, two pieces of orthogonal composite sinusoidal gratings, and a mechanical structure that can perform real-time linear positioning. The simulation results prove and demonstrate the validity of the method and the sensor in high-precision measurement of the wavefront gradient field.