A high-contrast grating(HCG) focusing reflector providing phase front control of reflected light and high reflectivity is proposed and fabricated.Basic design rules to engineer this category of structures are given ...A high-contrast grating(HCG) focusing reflector providing phase front control of reflected light and high reflectivity is proposed and fabricated.Basic design rules to engineer this category of structures are given in detail.A 1550 nm TM polarized incident light of 11.86 mm in focal length and 0.8320 in reflectivity is obtained in experiment.The wavelength dependence of the fabricated HCGs from 1530 nm to 1580 nm is also tested.The test results show that the focal length is in the range of 11.81-12 mm,which is close to the designed focal length of 15 mm.The reflectivity is almost above 0.56 within a bandwidth of 50 nm.At a distance of 11.86 mm,the light is focused to a round spot with the highest concentration,which is much smaller than the size of the incident beam.The FWHM of the reflected light beam decreases to 120 nm,and the intensity increases to 1.18.展开更多
The optical wavelet filter is designed. It can filter and choose frequency swiftly. It can realize demodulation of distributed fiber Bragg grating(FBG) measurement system. Its scanning resolution and scanning period...The optical wavelet filter is designed. It can filter and choose frequency swiftly. It can realize demodulation of distributed fiber Bragg grating(FBG) measurement system. Its scanning resolution and scanning period depend on wavelet function. Wavelet function is controlled by computer. Compared to conventional scan filter, optical wavelet filtering has some advantages such as simple structure, high scan frequency, high resolution and good linearity. At last, the error of optical wavelet filter scanning procedure is analyzed. Scanning step length refers to the shifting of optical wavelet window's central frequency. It affects system precision directly. If scanning step length is different, the measured signal is different. The methods of reducing step length guarantee scanning periodic time are presented.展开更多
For different external cavity lengths, lasing wavelength variation of fiber grating external cavity semiconductor laser (FGECSL) with ambient temperature has been investigated theoretically, and the theoretical result...For different external cavity lengths, lasing wavelength variation of fiber grating external cavity semiconductor laser (FGECSL) with ambient temperature has been investigated theoretically, and the theoretical results are in agreement with reported experimental observations.展开更多
基金Project supported by the National Natural Science Foundation of China(Grant Nos.61274044,61574019 and 61020106007)the National Basic Research Program of China(Grant No.2010CB327600)+4 种基金the Specialized Research Fund for the Doctoral Program of Higher Education of China(Grant No.20130005130001)the Natural Science Foundation of Beijing,China(Grant No.4132069)the Key International Science and Technology Cooperation Project of China(Grant No.2011RR000100)the 111 Project of China(Grant No.B07005)the Program for Changjiang Scholars and Innovative Research Team in Universities of China(Grant No.IRT0609)
文摘A high-contrast grating(HCG) focusing reflector providing phase front control of reflected light and high reflectivity is proposed and fabricated.Basic design rules to engineer this category of structures are given in detail.A 1550 nm TM polarized incident light of 11.86 mm in focal length and 0.8320 in reflectivity is obtained in experiment.The wavelength dependence of the fabricated HCGs from 1530 nm to 1580 nm is also tested.The test results show that the focal length is in the range of 11.81-12 mm,which is close to the designed focal length of 15 mm.The reflectivity is almost above 0.56 within a bandwidth of 50 nm.At a distance of 11.86 mm,the light is focused to a round spot with the highest concentration,which is much smaller than the size of the incident beam.The FWHM of the reflected light beam decreases to 120 nm,and the intensity increases to 1.18.
基金This project is supported by National Natural Science Foundation of China(No.60377002).
文摘The optical wavelet filter is designed. It can filter and choose frequency swiftly. It can realize demodulation of distributed fiber Bragg grating(FBG) measurement system. Its scanning resolution and scanning period depend on wavelet function. Wavelet function is controlled by computer. Compared to conventional scan filter, optical wavelet filtering has some advantages such as simple structure, high scan frequency, high resolution and good linearity. At last, the error of optical wavelet filter scanning procedure is analyzed. Scanning step length refers to the shifting of optical wavelet window's central frequency. It affects system precision directly. If scanning step length is different, the measured signal is different. The methods of reducing step length guarantee scanning periodic time are presented.
文摘For different external cavity lengths, lasing wavelength variation of fiber grating external cavity semiconductor laser (FGECSL) with ambient temperature has been investigated theoretically, and the theoretical results are in agreement with reported experimental observations.