A four-channel 400 GHz channel spacing InP-based arrayed waveguide grating with a flattened wavelength re- sponse by employing a multimode interference coupler at the input waveguide of the filter is prepared. The fab...A four-channel 400 GHz channel spacing InP-based arrayed waveguide grating with a flattened wavelength re- sponse by employing a multimode interference coupler at the input waveguide of the filter is prepared. The fabricated devices show a flattened spectral response with a broadened 3-dB bandwidth up to 3.5 nm, interchan- nel non-uniformity of 〈0. 7dB and excellent match to the simulation results.展开更多
A new miniature spectrometer with two entrance slits is proposed to expand the spectral band. The proposed spectrometer is designed such that the two entrance slits share the same concave grating and detector array. T...A new miniature spectrometer with two entrance slits is proposed to expand the spectral band. The proposed spectrometer is designed such that the two entrance slits share the same concave grating and detector array. The two slits are located at different positions such that the spectral range of the same light source incident on the detector array varies greatly between the two slits. Only one of the two slits is illuminated at a given time; as such, the two spectral ranges are sequentially measured. Theoretical calculation and experimentation are conducted to verify the proposed design.展开更多
基金Supported by the National Natural Science Foundation of China under Grant Nos 61274046,61201103,61335009 and61320106013the National Basic Research Program of China under Grant No 2013AA014202
文摘A four-channel 400 GHz channel spacing InP-based arrayed waveguide grating with a flattened wavelength re- sponse by employing a multimode interference coupler at the input waveguide of the filter is prepared. The fabricated devices show a flattened spectral response with a broadened 3-dB bandwidth up to 3.5 nm, interchan- nel non-uniformity of 〈0. 7dB and excellent match to the simulation results.
基金supported by the National Natural Science Foundation of China(No.61205167)the China Postdoctoral Science Foundation Funded Project(No.2015M571033)
文摘A new miniature spectrometer with two entrance slits is proposed to expand the spectral band. The proposed spectrometer is designed such that the two entrance slits share the same concave grating and detector array. The two slits are located at different positions such that the spectral range of the same light source incident on the detector array varies greatly between the two slits. Only one of the two slits is illuminated at a given time; as such, the two spectral ranges are sequentially measured. Theoretical calculation and experimentation are conducted to verify the proposed design.