期刊文献+
共找到60,543篇文章
< 1 2 250 >
每页显示 20 50 100
A Distributed Photovoltaics Ordering Grid-Connected Method for Analyzing Voltage Impact in Radial Distribution Networks
1
作者 Cuiping Li Kunqi Gao +4 位作者 Can Chen Junhui Li Xiaoxiao Wang Yinchi Shao Xingxu Zhu 《Energy Engineering》 EI 2024年第10期2937-2959,共23页
In recent years,distributed photovoltaics(DPV)has ushered in a good development situation due to the advantages of pollution-free power generation,full utilization of the ground or roof of the installation site,and ba... In recent years,distributed photovoltaics(DPV)has ushered in a good development situation due to the advantages of pollution-free power generation,full utilization of the ground or roof of the installation site,and balancing a large number of loads nearby.However,under the background of a large-scale DPV grid-connected to the county distribution network,an effective analysis method is needed to analyze its impact on the voltage of the distribution network in the early development stage of DPV.Therefore,a DPV orderly grid-connected method based on photovoltaics grid-connected order degree(PGOD)is proposed.This method aims to orderly analyze the change of voltage in the distribution network when large-scale DPV will be connected.Firstly,based on the voltagemagnitude sensitivity(VMS)index of the photovoltaics permitted grid-connected node and the acceptance of grid-connected node(AoGCN)index of other nodes in the network,thePGODindex is constructed to determine the photovoltaics permitted grid-connected node of the current photovoltaics grid-connected state network.Secondly,a photovoltaics orderly grid-connected model with a continuous updating state is constructed to obtain an orderly DPV grid-connected order.The simulation results illustrate that the photovoltaics grid-connected order determined by this method based on PGOD can effectively analyze the voltage impact of large-scale photovoltaics grid-connected,and explore the internal factors and characteristics of the impact. 展开更多
关键词 Radial distribution network distributed photovoltaics photovoltaics grid-connected order degree electrical distance photovoltaics action area
下载PDF
Comprehensive Evaluation of Distributed PV Grid-Connected Based on Combined Weighting Weights and TOPSIS-RSR Method
2
作者 Yue Yang Jiarui Zheng +2 位作者 Long Cheng Yongnan Zhu Hao Wu 《Energy Engineering》 EI 2024年第3期703-728,共26页
To effectively quantify the impact of distributed photovoltaic(PV)access on the distribution network,this paper proposes a comprehensive evaluation method of distributed PV grid connection combining subjective and obj... To effectively quantify the impact of distributed photovoltaic(PV)access on the distribution network,this paper proposes a comprehensive evaluation method of distributed PV grid connection combining subjective and objective combination of assignment and technique for order preference by similarity to an ideal solution(TOPSIS)—rank sum ratio(RSR)(TOPSIS-RSR)method.Based on the traditional distribution network evaluation system,a comprehensive evaluation system has been constructed.It fully considers the new development requirements of distributed PV access on the environmental friendliness and absorptive capacity of the distribution grid and comprehensively reflects the impact of distributed PV grid connection.The analytic hierarchy process(AHP)was used to determine the subjective weights of the primary indicators,and the Spearman consistency test was combined to determine the weights of the secondary indicators based on three objective assignment methods.The subjective and objective combination weights of each assessment indicator were calculated through the principle of minimum entropy.Calculate the distance between the indicators to be evaluated and the positive and negative ideal solutions,the relative closeness ranking,and qualitative binning by TOPSIS-RSR method to obtain the comprehensive evaluation results of different scenarios.By setting up different PV grid-connected scenarios and utilizing the IEEE33 node simulation algorithm,the correctness and effectiveness of the proposed subject-object combination assignment and integrated assessment method are verified. 展开更多
关键词 Distributed PV grid-connected comprehensive evaluation evaluation indicator system combined subjective and objective empowerment TOPSIS-RSR method
下载PDF
Soft-switching Grid-connected PV Inverter With Interleaved Flyback Topology 被引量:15
3
作者 古俊银 吴红飞 +1 位作者 陈国呈 邢岩 《中国电机工程学报》 EI CSCD 北大核心 2011年第36期I0005-I0005,共1页
提出一种应用于单个光伏组件的软开关交错反激并网逆变器拓扑及其软开关控制策略。针对反激变压器漏感问题,提出漏感能量吸收回馈电路,实现了漏感能量吸收再利用,并实现了开关管漏源电压的钳位,提高了变换效率同时降低了开关管关断... 提出一种应用于单个光伏组件的软开关交错反激并网逆变器拓扑及其软开关控制策略。针对反激变压器漏感问题,提出漏感能量吸收回馈电路,实现了漏感能量吸收再利用,并实现了开关管漏源电压的钳位,提高了变换效率同时降低了开关管关断电压尖峰;提出基于数字处理器的反激变换器变开关频率谐振软开关控制策略,实现了开关管的零电压开通,同时改善了逆变器的电磁兼容特性;提出的交错并联反激逆变器有助于减小变压器和滤波器的体积,提高功率密度。详细分析变换器的工作原理,分析变开关频率谐振软开关控制方式的原理和实现条件,最后进行实验验证。 展开更多
关键词 拓扑结构 反激式 逆变器 软交换网 光伏 交错 软交换技术 低成本
下载PDF
Grid-connected inverter for wind power generation system 被引量:1
4
作者 杨勇 阮毅 +2 位作者 沈欢庆 汤燕燕 杨影 《Journal of Shanghai University(English Edition)》 CAS 2009年第1期51-56,共6页
In wind power generation system the grid-connected inverter is an important section for energy conversion and transmission, of which the performance has a direct influence on the entire wind power generation system. T... In wind power generation system the grid-connected inverter is an important section for energy conversion and transmission, of which the performance has a direct influence on the entire wind power generation system. The mathematical model of the grid-connected inverter is deduced firstly. Then, the space vector pulse width modulation (SVPWM) is analyzed. The power factor can be controlled close to unity, leading or lagging, which is realized based on H-type current controller and grid voltage vector-oriented control. The control strategy is verified by the simulation and experimental results with a good sinusoidal current, a small harmonic component and a fast dynamic response. 展开更多
关键词 grid-connected inverter space vector pulse width modulation (SVPWM) grid voltage vector-oriented power factor
下载PDF
Robust Dichotomy Solution-Based Model Predictive Control for the Grid-Connected Inverters with Disturbance Observer 被引量:5
5
作者 Huanyue Liao Xin Zhang Zhijun Ma 《CES Transactions on Electrical Machines and Systems》 CSCD 2021年第2期81-89,共9页
This paper proposes a robust dichotomy-based model predictive control(DS-MPC)with a fixed switching frequency for the grid-connected inverter(GCI).The proposed fast dichotomy algorithm can select and deduce the optima... This paper proposes a robust dichotomy-based model predictive control(DS-MPC)with a fixed switching frequency for the grid-connected inverter(GCI).The proposed fast dichotomy algorithm can select and deduce the optimal voltage vector dynamically through the space vector plane.Therefore,the proposed DS-MPC strategy could ensure dynamic performance and steady-state performance as well.Also,the current control robustness can be improved through DS-MPC with disturbance observer(DO)based on the extended Kalman filter(EKF).The novelty of this control is that the current control with fast dynamic response can be realized in the weak grid,even if the grid voltages are greatly distorted.Simulation and hardware experiments on the weak grid validate the effectiveness of the proposed DS-MPC with the EKF observer approach. 展开更多
关键词 Dichotomy solution-based model predictive control(DS-MPC) three-phase grid-connected inverter(GCI) weak grid voltage vector dichotomy
下载PDF
A novel dynamic equivalence method for grid-connected wind farm 被引量:2
6
作者 Jia-geng QIAO Zong-xiang LU Yong MIN 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2008年第4期558-563,共6页
Dynamic equivalence of the wind farm is a fundamental problem in the simulation of a power system connected with wind farms because it is unpractical to model every generator in a wind farm in detail. In this paper, a... Dynamic equivalence of the wind farm is a fundamental problem in the simulation of a power system connected with wind farms because it is unpractical to model every generator in a wind farm in detail. In this paper, an Equivalence Method based on the Output Characteristics (EMOC) is proposed, with which the wind farm composed of Squirrel-Cage Induction Generators (SCIGs) can be equivalent to one generator. By considering the diversity of wind generators and special operating characteristics of a wind farm, the equivalent generator based on EMOC responds accurately in various faults. No matter whether the wind farm is integrated in grid or just programmed, EMOC can be used to acquire an accurate equivalent generator. Simulation of the dynamic equivalence of an SCIG wind farm validated the method. 展开更多
关键词 grid-connected wind farm Dynamic equivalence Squirrel-Cage Induction Generator (SCIG) Genetic algorithm
下载PDF
Research on Control Strategy of Grid-connected Brushless Doubly-fed Wind Power System Based on Virtual Synchronous Generator Control 被引量:6
7
作者 Shuai Liang Shi Jin Long Shi 《CES Transactions on Electrical Machines and Systems》 CSCD 2022年第4期404-412,共9页
The brushless doubly-fed wind power system based on conventional power control strategies lacks ‘inertia’ and the ability to support grid,which leads to the decline of grid stability.Therefore,a control strategy of ... The brushless doubly-fed wind power system based on conventional power control strategies lacks ‘inertia’ and the ability to support grid,which leads to the decline of grid stability.Therefore,a control strategy of brushless doubly-fed reluctance generator(BDFRG) based on virtual synchronous generator(VSG) control is proposed to solve the problem in this paper.The output characteristics of BDFRG based on VSG are similar to a synchronous generator(SG),which can support the grid frequency and increase the system ‘inertia’.According to the mathematical model of BDFRG,the inner loop voltage source control of BDFRG is derived.In addition,the specific structure and parameter selection principle of outer loop VSG control are expounded.The voltage source control inner loop of BDFRG is combined with the VSG control outer loop to establish the overall architecture of BDFRG-VSG control strategy.Finally,the effectiveness and feasibility of the proposed strategy are verified in the simulation. 展开更多
关键词 Virtual synchronous generator Brushless doubly-fed relutance generator grid support ability Voltage source control
下载PDF
High Efficiency PCS with Scan-Type MPPT Control for a Grid-Connected PV Power Generation System 被引量:2
8
作者 Kazutaka Itako 《Journal of Energy and Power Engineering》 2014年第1期137-143,共7页
For a standalone PV (photovoltaic) power generation system, the author previously proposed a new MPPT (maximum power point tracking) control method in which the I-V characteristics are scanned with a detection int... For a standalone PV (photovoltaic) power generation system, the author previously proposed a new MPPT (maximum power point tracking) control method in which the I-V characteristics are scanned with a detection interval control that operates at specified intervals and monitors the maximum power point. The author has obtained satisfactory results using this new MPPT control method. This paper investigates the application of the new MPPT control method for a PCS (power conditioning system) in a grid-connected type PV power generation system. The experimental results clearly demonstrate that the developed PCS offers outstanding effectiveness in tracking the maximum power point in partially shaded environments. 展开更多
关键词 PV generation system MPPT control grid-connecting inverter DC-DC converter PCS.
下载PDF
Topology for current-source grid-connected inverter with improved effciency and pulse width modulation control strategy
9
作者 吴春华 陈国呈 +3 位作者 崔开涌 陈卫民 肖鹏 张翼 《Journal of Shanghai University(English Edition)》 CAS 2008年第6期554-559,共6页
A novel topology of the current-source grid-connected inverter is proposed based on the immittance converter theory. A control strategy of sine-sine pulse width modulation (PWM) is studied. Compared with the traditi... A novel topology of the current-source grid-connected inverter is proposed based on the immittance converter theory. A control strategy of sine-sine pulse width modulation (PWM) is studied. Compared with the traditional current-source inverter, the power frequency inductors and power frequency transformer are replaced with high frequency inductors and a high frequency transformer. Thus, the proposed inverter has advantages of small volume, low cost, low total harmonic distortion (THD), low power losses, high power factor (PF) and simple control. Furthermore, grid voltage cannot influence output current of the grid-connected inverter and the current-source inverter with a high PF that approaches one has been realized. Finally, validity of the theory analysis and feasibility of the control scheme are shown by simulation and experimental results. 展开更多
关键词 grid-connected current-source INVERTER immittance converter
下载PDF
Single Current Feedback Control Strategy for Grid-connected Inverters With LCL Filters 被引量:33
10
作者 CHEN Dong ZHANG Junming QIAN Zhaoming 《中国电机工程学报》 EI CSCD 北大核心 2013年第9期I0002-I0002,共1页
LCL滤波器广泛应用于并网逆变器系统中,其对高次谐波具有良好的衰减作用;但LCL滤波器为低阻尼三阶系统,容易发生谐振。传统的有源阻尼方法,通过对电容电流进行采样并反馈,能够抑制系统振荡,但增加了传感器数量。提出一种单电流反馈控制... LCL滤波器广泛应用于并网逆变器系统中,其对高次谐波具有良好的衰减作用;但LCL滤波器为低阻尼三阶系统,容易发生谐振。传统的有源阻尼方法,通过对电容电流进行采样并反馈,能够抑制系统振荡,但增加了传感器数量。提出一种单电流反馈控制策略,其采用入网电流两次微分的反馈方法,增加了系统阻尼,从而有效地抑制LCL滤波器的谐振尖峰,保证系统的稳定性;同时其对系统参数不敏感,并且不增加额外的传感器,是一种低成本高可靠性的控制策略。文中推导该控制策略下的系统传递函数,并分析系统的稳定性。最后,通过仿真和实验,验证提出的控制策略的可行性与有效性。 展开更多
关键词 并网逆变器 电流反馈 滤波器 控制策略 单路 三阶系统 主动阻尼 波衰减
下载PDF
Coordination of multiple grid-connected inverters for harmonic compensation
11
作者 郭晓瑞 郭吉丰 王剑 《Journal of Central South University》 SCIE EI CAS 2014年第8期3126-3132,共7页
For multiple grid-connected inverters with active filter function,it makes sense to regulate every unit to output maximum active power from photovoltaic arrays,as well as eliminate the harmonic due to the non-linear l... For multiple grid-connected inverters with active filter function,it makes sense to regulate every unit to output maximum active power from photovoltaic arrays,as well as eliminate the harmonic due to the non-linear loads connected to the electric networks.Naturally,a centralized control coordination strategy was proposed for the purpose of high facility utilization,good harmonic compensation ability and unwanted overcompensation condition.Based on a vector decoupling control scheme and generalized instantaneous reactive power theory,the solution was to allocate the harmonic eliminating task for every inverter according to the instantaneous power margin of each.The grid current always keeps sinusoidal in spite of non-linear load change and output active power change for any inverter.The simulation results validate the efficacy of the proposed coordination strategy. 展开更多
关键词 active filter HARMONICS grid-connected inverter decoupling control COORDINATION
下载PDF
Dual-loop Control Strategy for Grid-connected Inverter with LCL Filter
12
作者 Qiubo Peng Hongbin Pan +1 位作者 Yong Liu Lidan Xiang 《Energy and Power Engineering》 2013年第4期97-101,共5页
As to the concrete topology of three-phase LCL type grid-connected inverter with damping resistance, mathematical model was deduced in detail, using method of equivalent transformation to the structure diagram, dampin... As to the concrete topology of three-phase LCL type grid-connected inverter with damping resistance, mathematical model was deduced in detail, using method of equivalent transformation to the structure diagram, damping resistance was virtualized, mathematical model under the DQ frame that can realize decoupling control was established, a dual-loop control strategy for grid-connected inverter with LCL filter was proposed, the system stability was analyzed and the design method of controller was given. The proposed method overcame the flaws of loss increase, efficiency reduce and cost increase which were caused by damping resistance in LCL type grid-connected inverter, the system efficiency and power supply quality of the output were improved. Feasibility and effectiveness of the new method were validated by simulation and experimental results. 展开更多
关键词 Virtual DAMPING LCL Filter THREE-PHASE grid-connected Inverter DECOUPLING Control
下载PDF
Optimal Economical Sizing of Grid-Connected Hybrid Renewable Energy System 被引量:1
13
作者 Mohammad Masih Sediqi Masahiro Furukakoi +1 位作者 Mohammed E. Lotfy Atsushi Yona and Tomonobu Senjyu 《Journal of Energy and Power Engineering》 2017年第4期244-253,共10页
In this paper, an optimized model is proposed to find the best values for decision variables to optimize the grid connected hybrid renewable energy system which consists of photovoltaic panels, wind turbines and batte... In this paper, an optimized model is proposed to find the best values for decision variables to optimize the grid connected hybrid renewable energy system which consists of photovoltaic panels, wind turbines and battery bank for electrification to North-east region of Afghanistan to meet winter power shortages of the area. In the proposed model, there are three decision variables namely, the total area occupied by the set of PV panels, total swept area by the rotating turbines' blades, and the number of batteries. GA (genetic algorithm) is defined to find the optimal values of the decision variables. The objective of this research is to minimize the LCC (life cycle cost) of the hybrid renewable energy system, and ensuring at the same time systems reliability level which is measured in terms of LPSP (loss of power supply probability). 展开更多
关键词 grid-connected hybrid renewable energy system optimized model genetic algorithm.
下载PDF
Forecast of Power Generation for Grid-Connected Photo-voltaic System Based on Grey Theory and Verification Model
14
作者 Ying-zi Li Jin-cang Niu Li Li 《Energy and Power Engineering》 2013年第4期177-181,共5页
Being photovoltaic power generation affected by radiation strength, wind speed, clouds cover and environment temperature, the generating in each moment is fluctuating. The operational characteristics of grid-connected... Being photovoltaic power generation affected by radiation strength, wind speed, clouds cover and environment temperature, the generating in each moment is fluctuating. The operational characteristics of grid-connected PV systems are coincided with gray theory application conditions. A gray theory model has been applied in short-term forecast of grid-connected photovoltaic system. The verification model of the probability of small error will help to check the accuracy of the gray forecast results. The calculated result shows that the ?model accuracy has been greatly enhanced. 展开更多
关键词 FORECAST of Power Generation grid-connected Photovoltaic SYSTEM Data DISCRETIZATION GREEDY Algorithm Continuous Attributes ROUGH Sets
下载PDF
Norton equivalent circuit for current control loop of grid-connected system
15
作者 汤赐 杨耕 谭惊涛 《Journal of Central South University》 SCIE EI CAS 2014年第5期1852-1861,共10页
Modeling method for the current control loop of a grid-connected PWM inverter with the LCL output filter was discussed.Firstly,the current control loop with the LCL inverter-side current as feedback was established.Th... Modeling method for the current control loop of a grid-connected PWM inverter with the LCL output filter was discussed.Firstly,the current control loop with the LCL inverter-side current as feedback was established.Then,parameters of PI controller were calculated on the basis of an equivalent controlled object.Finally,Norton equivalent circuit for the current control loop of grid-connected system was derived by integrating one control equation,which connected the PWM inverter output voltage and the LCL inverter-side current,with two circuit equations,separately using the LCL inverter-side current and the injected current as loop currents.With the induced Norton equivalent circuit,system-level resonant and unstable issues on real grid-connected system applied in weak distributed power systems can be easily analyzed.The validity of substituting Norton equivalent circuit for grid-connected system is verified by simulation and experiment. 展开更多
关键词 grid-connected system PWM inverter LCL output filter weak distributed power system
下载PDF
An Improved Repetitive Control Strategy for LCL Grid-Connected Inverter
16
作者 Ning He Chenlu Song +1 位作者 Feng Gao Cheng Qian 《Journal of Beijing Institute of Technology》 EI CAS 2022年第4期391-400,共10页
This paper proposes a cascade repetitive control strategy based on odd internal mode,and combines it with proportional-integral(PI)control to establish a compound repetitive control system for improving the quality of... This paper proposes a cascade repetitive control strategy based on odd internal mode,and combines it with proportional-integral(PI)control to establish a compound repetitive control system for improving the quality of grid connected current of LCL grid connected inverter.More specifically,the proposed method could effectively improve the control effect of grid-connected current of LCL inverter,restrain current harmonics and reduce the distortion rate of grid-connected current.Simulation experiment is conducted to verify the proposed repetitive control strategy,and the verification results show that,compared with traditional PI control,the proposed improved compound repetitive control strategy has a higher response speed,and the steady-state and dynamic performance have also been significantly improved. 展开更多
关键词 grid-connected inverter LCL filter harmonic suppression repetitive control
下载PDF
Dynamic phasor-based hybrid simulation for multi-inverter grid-connected system
17
作者 Peng Yang Qian Li +2 位作者 Junyu Zhao Juanjuan Lu Yunfei Xu 《Global Energy Interconnection》 EI CAS CSCD 2023年第2期197-204,共8页
To realize the efficient transient simulation of a grid-connected power generation system based on multiple inverters, this paper proposes a hybrid simulation method integrating the models of electromagnetic transient... To realize the efficient transient simulation of a grid-connected power generation system based on multiple inverters, this paper proposes a hybrid simulation method integrating the models of electromagnetic transient and dynamic phasors. Based on a demonstration of the concepts and properties of dynamic phasors, the models of single-phase and three-phase inverters described by dynamic phasors are established first. Considering the numerical compatibility problem between dynamic phasors and instantaneous values, an interface scheme between dynamic phasors and instantaneous values is designed, and the efficiency and precision differences of various transformation methods are compared in detail.Finally, by utilizing MATLAB/Simulink, a hybrid simulation platform of a multi-inverter grid-connected system is built, and the efficiency and accuracy of the hybrid simulation are validated via comparison with the full electromagnetic transient simulation. 展开更多
关键词 Multi-inverter grid-connected system Electromagnetic transient Dynamic phasor Hybrid simulation
下载PDF
A Control Strategy for Grid-connected Inverters With LCL Filters 被引量:37
18
作者 HU Xuefeng WEI Zheng +2 位作者 CHEN Yihan GONG Chunying ZHANG Jiayan 《中国电机工程学报》 EI CSCD 北大核心 2012年第27期I0018-I0018,194,共1页
把LCL滤波器作为电压源型并网逆变器与电网的接口已受到广泛关注。与单电感L滤波器相比,利用电感值较小的LCL滤波器对入网电流的高次谐波具有显著的衰减效果,特别是在低开关频率的大功率并网逆变系统应用中更具明显优势,但是仅采用... 把LCL滤波器作为电压源型并网逆变器与电网的接口已受到广泛关注。与单电感L滤波器相比,利用电感值较小的LCL滤波器对入网电流的高次谐波具有显著的衰减效果,特别是在低开关频率的大功率并网逆变系统应用中更具明显优势,但是仅采用直接入网电流控制时,LCL滤波器接口的并网逆变器系统存在稳定性问题。该文采用电网侧电感电流和逆变侧电感电流双闭环控制策略对并网电流进行直接控制,电网侧电感电流作为外环更容易抑制并网电流的谐波因素,且可以直接控制入网电流的单位功率因数,采用逆变器侧电感电流作为内环可以增加系统阻尼,从而可抑制系统振荡,增加系统稳定性。对该方案进行系统建模,并深入分析了滤波器参数、控制器参数及系统稳定性之间的精确量化关系。仿真和实验结果表明,该控制策略既可有效抑制入网电流谐振和实现进网电流的高功率因数运行,同时又具有良好的稳态和动态性能。 展开更多
关键词 并网逆变器 控制策略 滤波器 供电网络 电流反馈 开关频率 三阶系统 谐波失真
下载PDF
Research on the Three-phase Photovoltaic Grid-connected Control Strategy
19
作者 Yukai Liu Zhijian Hu +2 位作者 Ziyong Zhang Jianglei Suo Kaibin Liang 《Energy and Power Engineering》 2013年第4期31-35,共5页
This paper mainly studies scheduling type photovoltaic generation system, and establishes a three-phase photovoltaic grid-connected model in Matlab/Simulink, which uses the MPPT control that can make full use of the s... This paper mainly studies scheduling type photovoltaic generation system, and establishes a three-phase photovoltaic grid-connected model in Matlab/Simulink, which uses the MPPT control that can make full use of the solar energy. At the same time, energy storage device is added. The inverter of the energy storage device adopts V/f control. In the running state of the islanding because of a certain power failure, it can maintain a constant voltage and frequency. The simulation shows that as the output of the photovoltaic power increases, harmonic rate decreases under the same conditions, and the energy storage device can increase the stability of photovoltaic grid and reduce harmonic contents. So it’s very necessary to add energy storage device in the photovoltaic system. 展开更多
关键词 PHOTOVOLTAIC grid Energy Storage Device PQ CONTROL V/F CONTROL HARMONIC Rate
下载PDF
A Modified-Simplified MPPT Technique for Three-Phase Single-State Grid-Connected PV Systems
20
作者 Anuchit Aurairat Boonyang Plangklang 《Computers, Materials & Continua》 SCIE EI 2022年第8期2375-2395,共21页
Nowadays,the single state inverter for the grid-connected photovoltaic(PV)systems is becoming more and more popular as they can reduce circuit complexity resulting in less power losses of the inverter.This paper focus... Nowadays,the single state inverter for the grid-connected photovoltaic(PV)systems is becoming more and more popular as they can reduce circuit complexity resulting in less power losses of the inverter.This paper focuses on the use of model predictive control(MPC)to control a 3-phase and 2-level single-state grid-connected inverter in order to regulate the PV maximum power point(MPP).The algorithm of MPC scheme was done to measure the simultaneous current signal including predicting the next sampling current flow.The reference current(Id∗)was used to control the distribution of electrical power from the solar cell to the grid.To be able to control the maximum power point tracking(MPPT)when the sunlight suddenly changes,so that a developing MPPT based on estimation current perturbation and observation(ECP&O-MPPT)technique was used to control the reference current.This concept was experimented by using MATLAB/Simulink software package.The proposed technique was tested and compared with the old technique.The simulation results showed that the developed MPPT technique can track the MPP faster when the light changes rapidly under 1,000W/m2,25℃ standard climatic conditions.The MPPT time was 0.015 s.The total harmonic distortion(THD)was 2.17%and the power factor was 1. 展开更多
关键词 Single-state grid-connected model predictive control maximum power point estimation perturbation and observation
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部