期刊文献+
共找到119篇文章
< 1 2 6 >
每页显示 20 50 100
Comprehensive Evaluation of Distributed PV Grid-Connected Based on Combined Weighting Weights and TOPSIS-RSR Method
1
作者 Yue Yang Jiarui Zheng +2 位作者 Long Cheng Yongnan Zhu Hao Wu 《Energy Engineering》 EI 2024年第3期703-728,共26页
To effectively quantify the impact of distributed photovoltaic(PV)access on the distribution network,this paper proposes a comprehensive evaluation method of distributed PV grid connection combining subjective and obj... To effectively quantify the impact of distributed photovoltaic(PV)access on the distribution network,this paper proposes a comprehensive evaluation method of distributed PV grid connection combining subjective and objective combination of assignment and technique for order preference by similarity to an ideal solution(TOPSIS)—rank sum ratio(RSR)(TOPSIS-RSR)method.Based on the traditional distribution network evaluation system,a comprehensive evaluation system has been constructed.It fully considers the new development requirements of distributed PV access on the environmental friendliness and absorptive capacity of the distribution grid and comprehensively reflects the impact of distributed PV grid connection.The analytic hierarchy process(AHP)was used to determine the subjective weights of the primary indicators,and the Spearman consistency test was combined to determine the weights of the secondary indicators based on three objective assignment methods.The subjective and objective combination weights of each assessment indicator were calculated through the principle of minimum entropy.Calculate the distance between the indicators to be evaluated and the positive and negative ideal solutions,the relative closeness ranking,and qualitative binning by TOPSIS-RSR method to obtain the comprehensive evaluation results of different scenarios.By setting up different PV grid-connected scenarios and utilizing the IEEE33 node simulation algorithm,the correctness and effectiveness of the proposed subject-object combination assignment and integrated assessment method are verified. 展开更多
关键词 Distributed PV grid-connected comprehensive evaluation evaluation indicator system combined subjective and objective empowerment TOPSIS-RSR method
下载PDF
Dynamic phasor-based hybrid simulation for multi-inverter grid-connected system
2
作者 Peng Yang Qian Li +2 位作者 Junyu Zhao Juanjuan Lu Yunfei Xu 《Global Energy Interconnection》 EI CAS CSCD 2023年第2期197-204,共8页
To realize the efficient transient simulation of a grid-connected power generation system based on multiple inverters, this paper proposes a hybrid simulation method integrating the models of electromagnetic transient... To realize the efficient transient simulation of a grid-connected power generation system based on multiple inverters, this paper proposes a hybrid simulation method integrating the models of electromagnetic transient and dynamic phasors. Based on a demonstration of the concepts and properties of dynamic phasors, the models of single-phase and three-phase inverters described by dynamic phasors are established first. Considering the numerical compatibility problem between dynamic phasors and instantaneous values, an interface scheme between dynamic phasors and instantaneous values is designed, and the efficiency and precision differences of various transformation methods are compared in detail.Finally, by utilizing MATLAB/Simulink, a hybrid simulation platform of a multi-inverter grid-connected system is built, and the efficiency and accuracy of the hybrid simulation are validated via comparison with the full electromagnetic transient simulation. 展开更多
关键词 Multi-inverter grid-connected system Electromagnetic transient Dynamic phasor Hybrid simulation
下载PDF
Off-Grid Compressed Channel Estimation with Parallel Interference Cancellation for Millimeter Wave Massive MIMO
3
作者 Liu Jinru Tian Yongqing +1 位作者 Liu Danpu Zhang Zhilong 《China Communications》 SCIE CSCD 2024年第3期51-65,共15页
Millimeter wave(mmWave)massive multiple-input multiple-output(MIMO)plays an important role in the fifth-generation(5G)mobile communications and beyond wireless communication systems owing to its potential of high capa... Millimeter wave(mmWave)massive multiple-input multiple-output(MIMO)plays an important role in the fifth-generation(5G)mobile communications and beyond wireless communication systems owing to its potential of high capacity.However,channel estimation has become very challenging due to the use of massive MIMO antenna array.Fortunately,the mmWave channel has strong sparsity in the spatial angle domain,and the compressed sensing technology can be used to convert the original channel matrix into the sparse matrix of discrete angle grid.Thus the high-dimensional channel matrix estimation is transformed into a sparse recovery problem with greatly reduced computational complexity.However,the path angle in the actual scene appears randomly and is unlikely to be completely located on the quantization angle grid,thus leading to the problem of power leakage.Moreover,multiple paths with the random distribution of angles will bring about serious interpath interference and further deteriorate the performance of channel estimation.To address these off-grid issues,we propose a parallel interference cancellation assisted multi-grid matching pursuit(PIC-MGMP)algorithm in this paper.The proposed algorithm consists of three stages,including coarse estimation,refined estimation,and inter-path cyclic iterative inter-ference cancellation.More specifically,the angular resolution can be improved by locally refining the grid to reduce power leakage,while the inter-path interference is eliminated by parallel interference cancellation(PIC),and the two together improve the estimation accuracy.Simulation results show that compared with the traditional orthogonal matching pursuit(OMP)algorithm,the normalized mean square error(NMSE)of the proposed algorithm decreases by over 14dB in the case of 2 paths. 展开更多
关键词 channel estimation compressed sensing inter-path interference millimeter wave massive MIMO off-grid parallel interference cancellation
下载PDF
A novel dynamic equivalence method for grid-connected wind farm 被引量:2
4
作者 Jia-geng QIAO Zong-xiang LU Yong MIN 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2008年第4期558-563,共6页
Dynamic equivalence of the wind farm is a fundamental problem in the simulation of a power system connected with wind farms because it is unpractical to model every generator in a wind farm in detail. In this paper, a... Dynamic equivalence of the wind farm is a fundamental problem in the simulation of a power system connected with wind farms because it is unpractical to model every generator in a wind farm in detail. In this paper, an Equivalence Method based on the Output Characteristics (EMOC) is proposed, with which the wind farm composed of Squirrel-Cage Induction Generators (SCIGs) can be equivalent to one generator. By considering the diversity of wind generators and special operating characteristics of a wind farm, the equivalent generator based on EMOC responds accurately in various faults. No matter whether the wind farm is integrated in grid or just programmed, EMOC can be used to acquire an accurate equivalent generator. Simulation of the dynamic equivalence of an SCIG wind farm validated the method. 展开更多
关键词 grid-connected wind farm Dynamic equivalence Squirrel-Cage Induction Generator (SCIG) Genetic algorithm
下载PDF
Robust Dichotomy Solution-Based Model Predictive Control for the Grid-Connected Inverters with Disturbance Observer 被引量:5
5
作者 Huanyue Liao Xin Zhang Zhijun Ma 《CES Transactions on Electrical Machines and Systems》 CSCD 2021年第2期81-89,共9页
This paper proposes a robust dichotomy-based model predictive control(DS-MPC)with a fixed switching frequency for the grid-connected inverter(GCI).The proposed fast dichotomy algorithm can select and deduce the optima... This paper proposes a robust dichotomy-based model predictive control(DS-MPC)with a fixed switching frequency for the grid-connected inverter(GCI).The proposed fast dichotomy algorithm can select and deduce the optimal voltage vector dynamically through the space vector plane.Therefore,the proposed DS-MPC strategy could ensure dynamic performance and steady-state performance as well.Also,the current control robustness can be improved through DS-MPC with disturbance observer(DO)based on the extended Kalman filter(EKF).The novelty of this control is that the current control with fast dynamic response can be realized in the weak grid,even if the grid voltages are greatly distorted.Simulation and hardware experiments on the weak grid validate the effectiveness of the proposed DS-MPC with the EKF observer approach. 展开更多
关键词 Dichotomy solution-based model predictive control(DS-MPC) three-phase grid-connected inverter(GCI) weak grid voltage vector dichotomy
下载PDF
Grid-connected inverter for wind power generation system 被引量:1
6
作者 杨勇 阮毅 +2 位作者 沈欢庆 汤燕燕 杨影 《Journal of Shanghai University(English Edition)》 CAS 2009年第1期51-56,共6页
In wind power generation system the grid-connected inverter is an important section for energy conversion and transmission, of which the performance has a direct influence on the entire wind power generation system. T... In wind power generation system the grid-connected inverter is an important section for energy conversion and transmission, of which the performance has a direct influence on the entire wind power generation system. The mathematical model of the grid-connected inverter is deduced firstly. Then, the space vector pulse width modulation (SVPWM) is analyzed. The power factor can be controlled close to unity, leading or lagging, which is realized based on H-type current controller and grid voltage vector-oriented control. The control strategy is verified by the simulation and experimental results with a good sinusoidal current, a small harmonic component and a fast dynamic response. 展开更多
关键词 grid-connected inverter space vector pulse width modulation (SVPWM) grid voltage vector-oriented power factor
下载PDF
High Efficiency PCS with Scan-Type MPPT Control for a Grid-Connected PV Power Generation System 被引量:2
7
作者 Kazutaka Itako 《Journal of Energy and Power Engineering》 2014年第1期137-143,共7页
For a standalone PV (photovoltaic) power generation system, the author previously proposed a new MPPT (maximum power point tracking) control method in which the I-V characteristics are scanned with a detection int... For a standalone PV (photovoltaic) power generation system, the author previously proposed a new MPPT (maximum power point tracking) control method in which the I-V characteristics are scanned with a detection interval control that operates at specified intervals and monitors the maximum power point. The author has obtained satisfactory results using this new MPPT control method. This paper investigates the application of the new MPPT control method for a PCS (power conditioning system) in a grid-connected type PV power generation system. The experimental results clearly demonstrate that the developed PCS offers outstanding effectiveness in tracking the maximum power point in partially shaded environments. 展开更多
关键词 PV generation system MPPT control grid-connecting inverter DC-DC converter PCS.
下载PDF
Topology for current-source grid-connected inverter with improved effciency and pulse width modulation control strategy
8
作者 吴春华 陈国呈 +3 位作者 崔开涌 陈卫民 肖鹏 张翼 《Journal of Shanghai University(English Edition)》 CAS 2008年第6期554-559,共6页
A novel topology of the current-source grid-connected inverter is proposed based on the immittance converter theory. A control strategy of sine-sine pulse width modulation (PWM) is studied. Compared with the traditi... A novel topology of the current-source grid-connected inverter is proposed based on the immittance converter theory. A control strategy of sine-sine pulse width modulation (PWM) is studied. Compared with the traditional current-source inverter, the power frequency inductors and power frequency transformer are replaced with high frequency inductors and a high frequency transformer. Thus, the proposed inverter has advantages of small volume, low cost, low total harmonic distortion (THD), low power losses, high power factor (PF) and simple control. Furthermore, grid voltage cannot influence output current of the grid-connected inverter and the current-source inverter with a high PF that approaches one has been realized. Finally, validity of the theory analysis and feasibility of the control scheme are shown by simulation and experimental results. 展开更多
关键词 grid-connected current-source INVERTER immittance converter
下载PDF
Coordination of multiple grid-connected inverters for harmonic compensation
9
作者 郭晓瑞 郭吉丰 王剑 《Journal of Central South University》 SCIE EI CAS 2014年第8期3126-3132,共7页
For multiple grid-connected inverters with active filter function,it makes sense to regulate every unit to output maximum active power from photovoltaic arrays,as well as eliminate the harmonic due to the non-linear l... For multiple grid-connected inverters with active filter function,it makes sense to regulate every unit to output maximum active power from photovoltaic arrays,as well as eliminate the harmonic due to the non-linear loads connected to the electric networks.Naturally,a centralized control coordination strategy was proposed for the purpose of high facility utilization,good harmonic compensation ability and unwanted overcompensation condition.Based on a vector decoupling control scheme and generalized instantaneous reactive power theory,the solution was to allocate the harmonic eliminating task for every inverter according to the instantaneous power margin of each.The grid current always keeps sinusoidal in spite of non-linear load change and output active power change for any inverter.The simulation results validate the efficacy of the proposed coordination strategy. 展开更多
关键词 active filter HARMONICS grid-connected inverter decoupling control COORDINATION
下载PDF
Optimal Economical Sizing of Grid-Connected Hybrid Renewable Energy System 被引量:1
10
作者 Mohammad Masih Sediqi Masahiro Furukakoi +1 位作者 Mohammed E. Lotfy Atsushi Yona and Tomonobu Senjyu 《Journal of Energy and Power Engineering》 2017年第4期244-253,共10页
In this paper, an optimized model is proposed to find the best values for decision variables to optimize the grid connected hybrid renewable energy system which consists of photovoltaic panels, wind turbines and batte... In this paper, an optimized model is proposed to find the best values for decision variables to optimize the grid connected hybrid renewable energy system which consists of photovoltaic panels, wind turbines and battery bank for electrification to North-east region of Afghanistan to meet winter power shortages of the area. In the proposed model, there are three decision variables namely, the total area occupied by the set of PV panels, total swept area by the rotating turbines' blades, and the number of batteries. GA (genetic algorithm) is defined to find the optimal values of the decision variables. The objective of this research is to minimize the LCC (life cycle cost) of the hybrid renewable energy system, and ensuring at the same time systems reliability level which is measured in terms of LPSP (loss of power supply probability). 展开更多
关键词 grid-connected hybrid renewable energy system optimized model genetic algorithm.
下载PDF
Norton equivalent circuit for current control loop of grid-connected system
11
作者 汤赐 杨耕 谭惊涛 《Journal of Central South University》 SCIE EI CAS 2014年第5期1852-1861,共10页
Modeling method for the current control loop of a grid-connected PWM inverter with the LCL output filter was discussed.Firstly,the current control loop with the LCL inverter-side current as feedback was established.Th... Modeling method for the current control loop of a grid-connected PWM inverter with the LCL output filter was discussed.Firstly,the current control loop with the LCL inverter-side current as feedback was established.Then,parameters of PI controller were calculated on the basis of an equivalent controlled object.Finally,Norton equivalent circuit for the current control loop of grid-connected system was derived by integrating one control equation,which connected the PWM inverter output voltage and the LCL inverter-side current,with two circuit equations,separately using the LCL inverter-side current and the injected current as loop currents.With the induced Norton equivalent circuit,system-level resonant and unstable issues on real grid-connected system applied in weak distributed power systems can be easily analyzed.The validity of substituting Norton equivalent circuit for grid-connected system is verified by simulation and experiment. 展开更多
关键词 grid-connected system PWM inverter LCL output filter weak distributed power system
下载PDF
An Improved Repetitive Control Strategy for LCL Grid-Connected Inverter
12
作者 Ning He Chenlu Song +1 位作者 Feng Gao Cheng Qian 《Journal of Beijing Institute of Technology》 EI CAS 2022年第4期391-400,共10页
This paper proposes a cascade repetitive control strategy based on odd internal mode,and combines it with proportional-integral(PI)control to establish a compound repetitive control system for improving the quality of... This paper proposes a cascade repetitive control strategy based on odd internal mode,and combines it with proportional-integral(PI)control to establish a compound repetitive control system for improving the quality of grid connected current of LCL grid connected inverter.More specifically,the proposed method could effectively improve the control effect of grid-connected current of LCL inverter,restrain current harmonics and reduce the distortion rate of grid-connected current.Simulation experiment is conducted to verify the proposed repetitive control strategy,and the verification results show that,compared with traditional PI control,the proposed improved compound repetitive control strategy has a higher response speed,and the steady-state and dynamic performance have also been significantly improved. 展开更多
关键词 grid-connected inverter LCL filter harmonic suppression repetitive control
下载PDF
A Modified-Simplified MPPT Technique for Three-Phase Single-State Grid-Connected PV Systems
13
作者 Anuchit Aurairat Boonyang Plangklang 《Computers, Materials & Continua》 SCIE EI 2022年第8期2375-2395,共21页
Nowadays,the single state inverter for the grid-connected photovoltaic(PV)systems is becoming more and more popular as they can reduce circuit complexity resulting in less power losses of the inverter.This paper focus... Nowadays,the single state inverter for the grid-connected photovoltaic(PV)systems is becoming more and more popular as they can reduce circuit complexity resulting in less power losses of the inverter.This paper focuses on the use of model predictive control(MPC)to control a 3-phase and 2-level single-state grid-connected inverter in order to regulate the PV maximum power point(MPP).The algorithm of MPC scheme was done to measure the simultaneous current signal including predicting the next sampling current flow.The reference current(Id∗)was used to control the distribution of electrical power from the solar cell to the grid.To be able to control the maximum power point tracking(MPPT)when the sunlight suddenly changes,so that a developing MPPT based on estimation current perturbation and observation(ECP&O-MPPT)technique was used to control the reference current.This concept was experimented by using MATLAB/Simulink software package.The proposed technique was tested and compared with the old technique.The simulation results showed that the developed MPPT technique can track the MPP faster when the light changes rapidly under 1,000W/m2,25℃ standard climatic conditions.The MPPT time was 0.015 s.The total harmonic distortion(THD)was 2.17%and the power factor was 1. 展开更多
关键词 Single-state grid-connected model predictive control maximum power point estimation perturbation and observation
下载PDF
Dual-loop Control Strategy for Grid-connected Inverter with LCL Filter
14
作者 Qiubo Peng Hongbin Pan +1 位作者 Yong Liu Lidan Xiang 《Energy and Power Engineering》 2013年第4期97-101,共5页
As to the concrete topology of three-phase LCL type grid-connected inverter with damping resistance, mathematical model was deduced in detail, using method of equivalent transformation to the structure diagram, dampin... As to the concrete topology of three-phase LCL type grid-connected inverter with damping resistance, mathematical model was deduced in detail, using method of equivalent transformation to the structure diagram, damping resistance was virtualized, mathematical model under the DQ frame that can realize decoupling control was established, a dual-loop control strategy for grid-connected inverter with LCL filter was proposed, the system stability was analyzed and the design method of controller was given. The proposed method overcame the flaws of loss increase, efficiency reduce and cost increase which were caused by damping resistance in LCL type grid-connected inverter, the system efficiency and power supply quality of the output were improved. Feasibility and effectiveness of the new method were validated by simulation and experimental results. 展开更多
关键词 Virtual DAMPING LCL Filter THREE-PHASE grid-connected Inverter DECOUPLING Control
下载PDF
Bi-Level Energy Management Model of Grid-Connected Microgrid Community
15
作者 Haibin Cao Houqi Dong +3 位作者 Yongjie Ren Yuqing Wang Na Li Ming Zeng 《Energy Engineering》 EI 2022年第3期965-984,共20页
As the proportion of renewable energy power generation continues to increase,the number of grid-connected microgrids is gradually increasing,and geographically adjacent microgrids can be interconnected to form a Micro... As the proportion of renewable energy power generation continues to increase,the number of grid-connected microgrids is gradually increasing,and geographically adjacent microgrids can be interconnected to form a Micro-Grid Community(MGC).In order to reduce the operation and maintenance costs of a single micro grid and reduce the adverse effects caused by unnecessary energy interaction between the micro grid and the main grid while improving the overall economic benefits of the micro grid community,this paper proposes a bi-level energy management model with the optimization goal of maximizing the social welfare of the micro grid community and minimizing the total electricity cost of a single micro grid.The lower-level model optimizes the output of each equipment unit in the system and the exchange power between the system and the external grid with the goal of minimizing the operating cost of each microgrid.The upper-level model optimizes the goal ofmaximizing the socialwelfare of themicrogrid.Taking amicrogrid community with four microgrids as an example,the simulation analysis shows that the proposed optimization model is beneficial to reduce the operating cost of a single microgrid,improve the overall revenue of the microgrid community,and reduce the power interaction pressure on the main grid. 展开更多
关键词 Renewable energy grid-connected micro-grid community bi-level energy management model
下载PDF
Forecast of Power Generation for Grid-Connected Photo-voltaic System Based on Grey Theory and Verification Model
16
作者 Ying-zi Li Jin-cang Niu Li Li 《Energy and Power Engineering》 2013年第4期177-181,共5页
Being photovoltaic power generation affected by radiation strength, wind speed, clouds cover and environment temperature, the generating in each moment is fluctuating. The operational characteristics of grid-connected... Being photovoltaic power generation affected by radiation strength, wind speed, clouds cover and environment temperature, the generating in each moment is fluctuating. The operational characteristics of grid-connected PV systems are coincided with gray theory application conditions. A gray theory model has been applied in short-term forecast of grid-connected photovoltaic system. The verification model of the probability of small error will help to check the accuracy of the gray forecast results. The calculated result shows that the ?model accuracy has been greatly enhanced. 展开更多
关键词 FORECAST of Power Generation grid-connected Photovoltaic SYSTEM Data DISCRETIZATION GREEDY Algorithm Continuous Attributes ROUGH Sets
下载PDF
Quasi-Z Source Inverter Control of PV Grid-Connected Based on Fuzzy PCI
17
作者 Tao Hou Chen-Yang Zhang Hong-Xia Niu 《Journal of Electronic Science and Technology》 CAS CSCD 2021年第3期274-286,共13页
The photovoltaic grid-connected inverter is an important interface between the photovoltaic power generation system and power grid.Its high-quality operation is directly related to the output power quality of the powe... The photovoltaic grid-connected inverter is an important interface between the photovoltaic power generation system and power grid.Its high-quality operation is directly related to the output power quality of the power grid.In order to further optimize the control effect of the quasi-Z source grid-connected photovoltaic inverter,a fuzzy proportional complex integral control(PCI)method is proposed for the current internal loop control.This method can eliminate the steady-state error,and has the characteristic of zero steady-state error adjustment for the AC disturbance signal of a specific frequency.The inductance-capacitance-inductance(LCL)filter is adopted in the grid-connected circuit,and the feedback capacitive current is taken as the control variable of the inner loop to form the active damping control method,which can not only effectively suppress the resonance of the LCL circuit,but also significantly inhibit the high-order harmonics in the grid-connected current.Finally,a system simulation model is built in MATLAB/Simulink to verify the superiority and effectiveness of the proposed method. 展开更多
关键词 Frequency of harmonic distortion fuzzy proportional complex integral inductance-capacitance-inductance(LCL)filtering circuit photovoltaic grid-connection quasi-Z source inverter
下载PDF
FCS-MPC Strategy for PV Grid-Connected Inverter Based on MLD Model
18
作者 Xiaojuan Lu Qingbo Zhang 《Energy Engineering》 EI 2021年第6期1729-1740,共12页
In the process of grid-connected photovoltaic power generation,there are high requirements for the quality of the power that the inverter breaks into the grid.In this work,to improve the power quality of the grid-conn... In the process of grid-connected photovoltaic power generation,there are high requirements for the quality of the power that the inverter breaks into the grid.In this work,to improve the power quality of the grid-connected inverter into the grid,and the output of the system can meet the grid-connected requirements more quickly and accurately,we exhibit an approach toward establishing a mixed logical dynamical(MLD)model where logic variables were introduced to switch dynamics of the single-phase photovoltaic inverters.Besides,based on the model,our recent efforts in studying the finite control set model predictive control(FCS-MPC)and devising the output current full state observer are exciting for several advantages,including effectively avoiding the problem of the mixed-integer quadratic programming(MIQP),lowering the THD value of the output current of the inverter circuit,improving the quality of the power that the inverter breaks into the grid,and realizing the current output and the grid voltage same frequency and phase to meet grid connection requirements.Finally,the effectiveness of the mentioned methods is verified by MATLAB/Simulink simulation. 展开更多
关键词 Photovoltaic grid-connected inverter hybrid logic dynamic model finite control set model predictive control full state observer
下载PDF
Evaluation of the Performances of the First Grid-Connected Photovoltaic System in Sénégal
19
作者 P. W. Tavares H. D. Ndiath +3 位作者 M. Kane B. Mbow A. T. Niang I. Youm 《International Journal of Clean Coal and Energy》 2020年第1期1-14,共14页
This document presents the evaluation and the monitoring of the performances of the first grid-connected photovoltaic system installed in the Center of Studies and Researches on the Renewable Energies (CERER) inaugura... This document presents the evaluation and the monitoring of the performances of the first grid-connected photovoltaic system installed in the Center of Studies and Researches on the Renewable Energies (CERER) inaugurated on December 4th, 2012 by the governmental authorities of Senegal and Tenerife. This mini power plant of 3.15 kWc is a perfect example of the political will of the government which is to reduce the production cost of the electricity, with the diversification of the sources of production, and the greater use of the other sources such as the natural gas, the coal, the renewable energies. The evaluation of the performances of the installation is realized by using the indicators of efficiency and performance as the photovoltaic surface yield, the ratio of photovoltaic performance, the photovoltaic specific yield, and the losses of captures. The obtained results show that a big part of the energy shone during the period of observation was not able to be used further to circumstances such as the losses of conductivity, the heat losses or for example the defects on components. The analysis also shows that a large part of the produced energy is not injected because of the dilapidation of the network, the defects of landing but especially one disjunction sees frequently at the level of the point of injection. 展开更多
关键词 Analysis of the PERFORMANCES The PHOTOVOLTAIC SOLAR Energy grid-connected PV System Senegal
下载PDF
Influence of Control Modes of Grid-Connected Solar Photovoltaic Generation on Grid Power Flow
20
作者 Zakaria Al-Omari 《Engineering(科研)》 2014年第13期914-922,共9页
Integration of Solar Photovoltaic (PV) generation into an existing distribution system has many impacts on the system, with the power flow being one of the major issues. This impact is not generic for any network, but... Integration of Solar Photovoltaic (PV) generation into an existing distribution system has many impacts on the system, with the power flow being one of the major issues. This impact is not generic for any network, but it may manifest itself either positively or negatively, depending on the grid configuration, interface control modes, operation mode, and load profile. Grid-connected PV systems have three control options of the local voltage controller of the interface DC-AC converter. These control modes are Power Factor control, voltage control, and Droop Voltage control. This paper aims at evaluating and comparing the impacts of those control modes on the grid power flow. A set of evaluation criteria and indices is defined and mathematically formulated. Based on the requirements of the used program (Power Factory Dig Silent V14.1.3), a computation plan (algorithm) has been proposed. The algorithm has been applied to a typical weak network and a wide range of simulations has been carried out. Simulation results have been thoroughly discussed and important findings have been concluded. 展开更多
关键词 grid-connected PV Control MODES POWER Flow POWER FACTORY DIG SILENT Software
下载PDF
上一页 1 2 6 下一页 到第
使用帮助 返回顶部